Manual Pelco C841M-A

16 pages 0.38 mb
Download

Go to site of 16

Summary
  • Pelco C841M-A - page 1

    INST ALLA TION/OPERA TION V A6200 Series Sequential Switcher C841M-A (7/02) ...

  • Pelco C841M-A - page 2

    2 C841M-A (7/02) LIST OF ILLUSTRA TIONS Figure Page 1 Jumper Settings - V A6200 Series ............................................................................................... ..................................................................... 4 2 Fixed Cameras with T erminated Inputs ....................................................... ...

  • Pelco C841M-A - page 3

    C841M-A (7/02) 3 IMPORT ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following W ARNINGS should be observed. 1. Installation and servicing should be done only by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA T ype 3, 3R, 3S, 4, 4X ,6 or 6P enclosure ...

  • Pelco C841M-A - page 4

    4 C841M-A (7/02) INST ALLA TION 1. Remove the cover from the switcher . 2. Set the jumpers as required for your application. Refer to Figure 1 and T able A. 3. Replace the cover . 4. Place the unit on a flat surface or install it in an equipment rack using the appropriate rack-mount kit. 5. Make all equipment connections to the switcher . Refer to ...

  • Pelco C841M-A - page 5

    C841M-A (7/02) 5 Table A. Jumper Settings - VA6200 Series Jumper Position Function JP1 - JP20 A Camera input terminated (75 ohms) B Camera input looping (high impedance) JP23, JP24, JP25, JP26, JP28, JP31 A Camera titles on Monitor 1 B Camera titles on Monitor 2 JP29 or JP32 A P AL video standard B NTSC video standard JP30 or JP33 A Standard charac ...

  • Pelco C841M-A - page 6

    6 C841M-A (7/02) Figure 2. Fixed Cameras with Terminated Inputs Figure 3. Fixed Cameras with Looping Outputs ...

  • Pelco C841M-A - page 7

    C841M-A (7/02) 7 Figure 4. Movable Cameras with Terminated Inputs and Coaxitron Control Figure 5. Movable Cameras with Looping Outputs and Coaxitron Control ...

  • Pelco C841M-A - page 8

    8 C841M-A (7/02) Figure 6. Connector Assembly ...

  • Pelco C841M-A - page 9

    C841M-A (7/02) 9 OPERA TION T o operate the VA6200 Series Switcher: 1. Plug in the power cord. 2. Select the monitor by pushing the MON 1 or MON 2 button. 3. Press a camera button to view video from the corresponding camera. SEQUENCING T o run a sequence: 1. Select a monitor by pushing the MON 1 or MON 2 button. 2. Press the SEQ button. The camera ...

  • Pelco C841M-A - page 10

    10 C841M-A (7/02) DWELL TIME The time between switching from one camera to another is known as the dwell time. The dwell time can be set differently for each camera or it can be set the same (global) for all cameras on a monitor . T o check the dwell time: 1. Select a camera by pressing the button for that camera. 2. Press the camera button again. ...

  • Pelco C841M-A - page 11

    C841M-A (7/02) 11 ALARMS The alarm inputs must be enabled or disabled if you connected alarms on the switcher to them. T o enable or disable alarms: 1. Press the MON 1 button. 2. Press the recessed ALARM switch. The switch toggles the alarm inputs on and off. When the ON LED is lit, the alarm inputs are enabled. When the ON LED is out, the alarm in ...

  • Pelco C841M-A - page 12

    12 C841M-A (7/02) TROUBLESHOOTING PROBLEM SOLUTION No power Check the fuse . Video output quality poor Check jumper settings (Refer to Figure 1, T able A). (Examples: Squiggly video, poor contrast, picture not centered) Locked system or sequencing not working as desired Reset the switcher . There are two types of reset operations: 1. Restart operat ...

  • Pelco C841M-A - page 13

    C841M-A (7/02) 13 SPECIFICA TIONS VIDEO Inputs: T erminating (75 ohms) or looping (high impedance) NTSC and PAL compatible Outputs Monitor 1: 75 ohms Monitor 2: 75 ohms; half duplex (Coaxitron ® compatible). Requires field jumper change Gain: Unity Dwell: Camera dwell independently adjustable from 1 to 60 seconds nominal Frequency Response: 10 MHz ...

  • Pelco C841M-A - page 14

    14 C841M-A (7/02) GENERAL Construction Chassis: Steel, zinc plated Cover: Steel, textured black enamel Panel: Aluminum, with LEXAN ® overlay Dimensions V A6204 Series: 1.75 (H) x 5.50 (W) x 9.25 (D) inches (4.44 x 13.97 x 23.49 cm) V A6208 Series: 1.75 (H) x 8.75 (W) x 11.75 (D) inches (4.44 x 22.23 x 29.84 cm) V A6212 Series: 1.75 (H) x 14.25 (W) ...

  • Pelco C841M-A - page 15

    C841M-A (7/02) 15 REVISION HISTORY Manual # Date Comments C841M 12/99 Original version. C841M-A 7/02 Updated manual to new format. Removed reference to alarm breakout panel. PRODUCT WARRANTY AND RETURN INFORMA TION Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy , and Spectra are registered trademarks of Pelco. © Copyright 2002, Pelco. En ...

  • Pelco C841M-A - page 16

    World Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.com ISO 9001 Orangeburg, New York Las Vegas, Nevada Eindhoven, The Netherlands Wokingham, United Kingdom Montreal, Canada ...

Manufacturer Pelco Category Switch

Documents that we receive from a manufacturer of a Pelco C841M-A can be divided into several groups. They are, among others:
- Pelco technical drawings
- C841M-A manuals
- Pelco product data sheets
- information booklets
- or energy labels Pelco C841M-A
All of them are important, but the most important information from the point of view of use of the device are in the user manual Pelco C841M-A.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Pelco C841M-A, service manual, brief instructions and user manuals Pelco C841M-A. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Pelco C841M-A.

Similar manuals

A complete manual for the device Pelco C841M-A, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Pelco C841M-A by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Pelco C841M-A.

A complete Pelco manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Pelco C841M-A - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Pelco C841M-A, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Pelco C841M-A, that we can find in the current document
3. Tips how to use the basic functions of the device Pelco C841M-A - which should help us in our first steps of using Pelco C841M-A
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Pelco C841M-A
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Pelco C841M-A in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Pelco C841M-A?

Use the form below

If you did not solve your problem by using a manual Pelco C841M-A, ask a question using the form below. If a user had a similar problem with Pelco C841M-A it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)