Manual Vulcan-Hart EF3 ML-52099

16 pages 6.12 mb
Download

Go to site of 16

Summary
  • Vulcan-Hart EF3 ML-52099 - page 1

    – 1 – SER VICE MANUAL VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791 FORM 31208 (Apr. 2002) www.vulcanhart.com EF SERIES ST AND ARD AND FIL TER-READ Y GAS FR YERS MODELS EF 3 ML-52099 EF 4 ML-114943 EF 5 ML-114944 NOTICE THIS MANUAL IS PREPARED FOR THE USE OF TRAINED VULCAN SERVICE TECHNICIANS AND SHOULD NOT B ...

  • Vulcan-Hart EF3 ML-52099 - page 2

    – 2 – © VULCAN-HART COMPANY, 2002 T ABLE OF CONTENTS GENERAL .............................................................................................................................................................. 3 Introduction .............................................................................................................. ...

  • Vulcan-Hart EF3 ML-52099 - page 3

    – 3 – NOTE: If pilot does not remain lit, repeat steps 2 through 5, but allow a longer period of time before releasing the combination valve knob. Adjust pilot flame, if necessary, as outlined under Pilot Adjustment in Service Procedures and Adjustments. 6. Turn combination valve knob to ON. SPECIFICATIONS Gas Data TOOLS Standard • Hand tools ...

  • Vulcan-Hart EF3 ML-52099 - page 4

    – 4 – COVERS AND PANELS WARNING: SHUT OFF THE GAS BEFORE SERVICING. Door and Front Panel 1. Open door and remove screws from front panel. 2. Hold door. Lift up and remove front panel. 3. Lift door off bottom hinge. 4. Reverse procedure to install. Heat Shield 1. Remove screws holding heat shield in place. 2. Remove heat shield. BURNERS WARNING: ...

  • Vulcan-Hart EF3 ML-52099 - page 5

    – 5 – 3. Push burner up while pulling the bottom of the burner forward to clear the burner nozzle. 4. Reverse the procedure to install. THERMOSTAT WARNING: SHUT OFF THE GAS BEFORE SERVICING. 1. Drain shortening from fry tank. 2. Remove heat shield as outlined under Covers and Panels. 3. Remove left burner as outlined under Burners. 4. Remove th ...

  • Vulcan-Hart EF3 ML-52099 - page 6

    – 6 – 7. Loosen the packing nut and holding nut. 8. Remove the thermostat bulb from the clamp. 9. Pull the thermostat bulb through the underside of the fry tank and remove the thermostat assembly. 1 0. Reverse the procedure to install. When installing the new thermostat assembly, do not kink the thermostat capillary. Wrap threads of packing nut ...

  • Vulcan-Hart EF3 ML-52099 - page 7

    – 7 – 6. Loosen the packing nut and the holding nut. 7. Remove the high limit bulb from the clamp. 8. Pull the high limit bulb through the underside of the fry tank and remove the high limit assembly. 9. Reverse the procedure to install. When installing the new high limit assembly, do not kink the high limit capillary. Wrap threads of packing n ...

  • Vulcan-Hart EF3 ML-52099 - page 8

    – 8 – 6. Remove thermopile from pilot bracket. 7. Reverse procedure to install. PILOT ORIFICE WARNING: SHUT OFF THE GAS BEFORE SERVICING. WARNING: ALL GAS JOINTS DISTURBED DURING SERVICING MUST BE CHECKED FOR LEAKS. CHECK WITH SOAP AND WATER SOLUTION (BUBBLES). DO NOT USE AN OPEN FLAME. 1. Remove pilot assembly from fryer as outlined under ther ...

  • Vulcan-Hart EF3 ML-52099 - page 9

    – 9 – 5. Remove screws holding fry tank. 6. Remove burners as outlined under Burners. 7. Remove the manifold bracket from the tank assembly. 8. Remove thermostat and high limit as outlined under Thermostat and High Limit. 9. Remove screws holding pilot assembly to bracket and remove pilot assembly. 10. Lift the fry tank up and out of cabinet. C ...

  • Vulcan-Hart EF3 ML-52099 - page 10

    – 10 – SER VICE PR OCEDURES AND ADJUSTMENTS MILLIVOLT CONTROLS TEST 1. Verify proper gas (natural or propane) is present. 2 . Check for correct wiring and secure connections. 3. Verify the pilot flame is adjusted properly as outlined in Pilot Adjustment. 4. If the pilot is not lit, light pilot as outlined under Lighting Pilot. Allow the pilot t ...

  • Vulcan-Hart EF3 ML-52099 - page 11

    – 11 – 5. Allow temperature to stabilize at new setting and compare temperature tester to dial setting. Recalibrate if the temperature does not fall within the range of 330 ° F to 370 ° F. 6. If the temperature does not fall within the limits at both settings, replace the thermostat. PILOT ADJUSTMENT 1. Light pilot as outlined under Lighting ...

  • Vulcan-Hart EF3 ML-52099 - page 12

    – 12 – 2. Remove the plug from the submanifold and install pressure gauge at this point. 3. Turn on the gas and light the pilot as outlined under Lighting Pilot in General. 4. Turn the combination valve to ON. 5. Set the thermostat so the burners will come on. 6. Read the pressure gauge. The manifold pressure reading should match the pressure r ...

  • Vulcan-Hart EF3 ML-52099 - page 13

    – 13 – 3. Total Shutdown. A . When the high limit trips, 0.0 millivolts will read across both coils of the combination valve, causing both valves to close. B . Pilot relight cannot be accomplished until oil cools sufficiently to allow high limit to close. C . If any wire in the system is cut or broken, the system will shut down. SYSTEM CONDITIO ...

  • Vulcan-Hart EF3 ML-52099 - page 14

    – 14 – M V R E D W H T THERMOST A T LIMIT 2 3 4 1 PL-56159 SCHEMATIC COMPONENT FUNCTION Thermostat - Millivolt type with capillary bulb, single-throw break on temperature rise. Temperature range of 200 ° F to 400 ° F. Thermopile - Millivolt control with 24" capillary. Rated to generate 500 millivolts. Combination Valve - Regulates gas fl ...

  • Vulcan-Hart EF3 ML-52099 - page 15

    – 15 – TR OUBLESHOO TING SYMPTOM 1 . The temperature of the shortening drops, or excessive recovery time is required. POSSIBLE CAUSE A . Insufficient gas supply to unit. B . Ventilating system pulling heat out of heat exchanger and flue box. C . Overloading fryer capacity. A . Malfunctioning thermopile or loose/dirty connection in thermopile. B ...

  • Vulcan-Hart EF3 ML-52099 - page 16

    – 16 – FORM 31208 (Apr. 2002) PRINTED IN U.S.A. SYMPTOM 4. Leaking tank. TR OUBLESHOO TING POSSIBLE CAUSE A. Foam-over by depleted shortening permits oil to drip from the tank surface, giving the appearance of leaking. B . Careless draining procedures. Gas valve should be in the PILOT or OFF position before draining oil. Burners heating an empt ...

Manufacturer Vulcan-Hart Category Fryer

Documents that we receive from a manufacturer of a Vulcan-Hart EF3 ML-52099 can be divided into several groups. They are, among others:
- Vulcan-Hart technical drawings
- EF3 ML-52099 manuals
- Vulcan-Hart product data sheets
- information booklets
- or energy labels Vulcan-Hart EF3 ML-52099
All of them are important, but the most important information from the point of view of use of the device are in the user manual Vulcan-Hart EF3 ML-52099.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Vulcan-Hart EF3 ML-52099, service manual, brief instructions and user manuals Vulcan-Hart EF3 ML-52099. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Vulcan-Hart EF3 ML-52099.

A complete manual for the device Vulcan-Hart EF3 ML-52099, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Vulcan-Hart EF3 ML-52099 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Vulcan-Hart EF3 ML-52099.

A complete Vulcan-Hart manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Vulcan-Hart EF3 ML-52099 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Vulcan-Hart EF3 ML-52099, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Vulcan-Hart EF3 ML-52099, that we can find in the current document
3. Tips how to use the basic functions of the device Vulcan-Hart EF3 ML-52099 - which should help us in our first steps of using Vulcan-Hart EF3 ML-52099
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Vulcan-Hart EF3 ML-52099
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Vulcan-Hart EF3 ML-52099 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Vulcan-Hart EF3 ML-52099?

Use the form below

If you did not solve your problem by using a manual Vulcan-Hart EF3 ML-52099, ask a question using the form below. If a user had a similar problem with Vulcan-Hart EF3 ML-52099 it is likely that he will want to share the way to solve it.

Copy the text from the picture