Manual Vanguard Heating SBVBP(A)

32 pages 0.71 mb
Download

Go to site of 32

Summary
  • Vanguard Heating SBVBP(A) - page 1

    CAST IRON STOVE B-VENT FREEST ANDING FIREPLACE HEA TER ® OWNER’S OPERA TION AND INST ALLA TION MANUAL ® SBVBN(A), SBVBP(A) REMOTE READY Save this manual for future reference. FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch • Do not use any phone in your building. • Im ...

  • Vanguard Heating SBVBP(A) - page 2

    2 ® B -VENT FREEST ANDING FIREPLACE 105500 SAFETY INFORMA TION 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used. 2. For propane/LP fireplace, do not place propane/LP supply tank(s) inside any structure. Locate propane/LP s ...

  • Vanguard Heating SBVBP(A) - page 3

    3 105500 OWNER’S MANUAL P I L O T L O H I OFF ON ON OFF AUTO PRODUCT IDENTIFICA TION Install and use fireplace with care. Follow all local codes. In the absence to local codes, use the current National Fuel Gas Code ANS Z223.1 , also known as NFPA 54* (USA) or the current CAN/CGA-B149[.1 or .2] Installation Codes (Canada) . *Available from: Ameri ...

  • Vanguard Heating SBVBP(A) - page 4

    4 ® B -VENT FREEST ANDING FIREPLACE 105500 LOCATION AND SPACE REQUIREMENTS Determine the safest and most efficient loca- tion for your Vanguard B-vent freestanding fireplace. Make sure that rafters and wall studs are not in the way of the venting system. Choose a location where the heat output is not affected by drafts, air conditioning ducts, win ...

  • Vanguard Heating SBVBP(A) - page 5

    5 105500 OWNER’S MANUAL Pallet Wood Bolted to Bottom of Stove Body STOVE BODY ASSEMBLY 1. Lift of f corrugated box enclosing sto ve body crating. 2. Remove all screws fastening the wood frame enclosure. Spread wood frame open and lift away from plastic-bagged stove body . The bottom pieces of pallet wood will remain bolted to the sto ve body . 3. ...

  • Vanguard Heating SBVBP(A) - page 6

    6 ® B -VENT FREEST ANDING FIREPLACE 105500 FREEST ANDING FIREPLACE ASSEMBL Y Continued Figure 12 - Attaching Stove Door Step Bolt Door Hinge Threaded Hole Stove Door Stove Bottom Bolt Shoulder Adjusting Nut Bolt Stop Catch Bolt Door Claw Door Figure 13 - Catch Bolt and Door Claw Orientation 10. Attach stove door by inserting step bolt through door ...

  • Vanguard Heating SBVBP(A) - page 7

    7 105500 OWNER’S MANUAL WARNING: Never touch the blower wheel while in operation. 7. Peel off the bac king paper and stick the supplied wiring diagram decal on the inside of rear cover on right side oppo- site control. WARNING: Failure to position the parts in accordance with sup- plied diagrams or failure to use only parts specifically approved ...

  • Vanguard Heating SBVBP(A) - page 8

    8 ® B -VENT FREEST ANDING FIREPLACE 105500 INSTALLATION PRECAUTIONS Consult local building codes before begin- ning the installation. Only a qualified ser- vice person should install venting system. The installer must follow these safety rules: • W ear gloves and safety glasses for protection • Use e xtreme caution when using ladders or when o ...

  • Vanguard Heating SBVBP(A) - page 9

    9 105500 OWNER’S MANUAL Figure 18 - Typical B-Vent Installation WARNING: Installation should only be made by qualified per- sons who are familiar with the safety procedures required for the installation of the product, who are equipped with the proper tools and testing instruments, and who have achieved proper certification of licensing. Instal- ...

  • Vanguard Heating SBVBP(A) - page 10

    10 ® B -VENT FREEST ANDING FIREPLACE 105500 VENTING INST ALLA TION Continued CHECKING VENT CAPACITY Complete all gas piping, electrical, and vent connections. After adjusting the fireplace and lighting the main burners, allow a couple of minutes for warm-up. Hold a lighted match just under the rim of the draft hood relief opening. Proper venting w ...

  • Vanguard Heating SBVBP(A) - page 11

    11 105500 OWNER’S MANUAL VENTING INST ALLA TION Continued HIGH ALTITUDE INSTALLATION Your Vanguard B-vent freestanding fireplace heater has been AGA tested and approved for elevations from 0-2000 feet and CGA certi- fied for elevations from 0-4500 feet. When installing this fireplace at an eleva- tion above 2000 feet (in the USA), you may need to ...

  • Vanguard Heating SBVBP(A) - page 12

    12 ® B -VENT FREEST ANDING FIREPLACE 105500 CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to fireplace. If pipe is too small, undue loss of pressure will occur. Installation must include a ...

  • Vanguard Heating SBVBP(A) - page 13

    13 105500 OWNER’S MANUAL Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect fireplace and its individual manual shutoff v alve from gas supply piping system. Pressures in excess of 1/2 psig (3.5 kPa) will damage fireplace gas regulator . 2. Cap of f open end of gas pipe where manual shutof f val ...

  • Vanguard Heating SBVBP(A) - page 14

    14 ® B -VENT FREEST ANDING FIREPLACE 105500 FIREPLACE INST ALLA TION Continued Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close manual shutof f valve (see Figure 28). 2. Pressurize supply piping system by ei- ther opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas mete ...

  • Vanguard Heating SBVBP(A) - page 15

    15 105500 OWNER’S MANUAL FIREPLACE INST ALLA TION Continued INSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1 WARNING: Installation must be done by a qualified installer familiar with low voltage wiring procedures. WARNING: Do not connect this thermostat to any electrical source! Electrical shock and/or fire hazard will occur. 1. Open lower doo ...

  • Vanguard Heating SBVBP(A) - page 16

    16 ® B -VENT FREEST ANDING FIREPLACE 105500 REMOVING/REPLACING GLASS DOOR CAUTION: Do not operate this fireplace with a broken glass door panel or without the glass door panel securely in place. For re- placement part information see Replacement Parts , page 25. 1. Remove 2 bolts from bottom of stove and one from the top of stove to remove front p ...

  • Vanguard Heating SBVBP(A) - page 17

    17 105500 OWNER’S MANUAL Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with freestanding fireplace. 1. Remov e glass door . See Removing/Re- placing Glass Door , page 16. 2. Place log #1 (b ...

  • Vanguard Heating SBVBP(A) - page 18

    18 ® B -VENT FREEST ANDING FIREPLACE 105500 TO TURN OFF GAS TO APPLIANCE 1. Open lower louver panel. 2 a . Set selector switch in the “OFF” position. 2b . If Using Optional Hand-Held Re- mote: Set selector switch in the OFF position to pre vent draining battery . 3. T urn off all electrical po wer to the appliance if service is to be perf orme ...

  • Vanguard Heating SBVBP(A) - page 19

    19 105500 OWNER’S MANUAL 1. After lighting, let pilot flame bur n f or about one minute. T urn contr ol knob on the control v alve to ON position. T urn flame adjustment knob any- where between HI and LO. Slide the selector switch to the REMO TE posi- tion. Note: The b urners may light if hand-held remote ON b utton was on when selector switch wa ...

  • Vanguard Heating SBVBP(A) - page 20

    20 ® B -VENT FREEST ANDING FIREPLACE 105500 INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. PILOT ASSEMBLY The pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling. Call a qualified service person to readjust the pilot if necessary. The height of the ...

  • Vanguard Heating SBVBP(A) - page 21

    21 105500 OWNER’S MANUAL CLEANING AND MAINTENANCE WARNING: Turn off fireplace and let cool before cleaning. CAUTION: You must keep con- trol areas, burners, and circulat- ing air passageways of fireplace clean. Inspect these areas of fire- place before each use. Have fire- place inspected yearly by a quali- fied service person. Fireplace may need ...

  • Vanguard Heating SBVBP(A) - page 22

    22 ® B -VENT FREEST ANDING FIREPLACE 105500 TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean pilot. This can damage pilot unit. POSS ...

  • Vanguard Heating SBVBP(A) - page 23

    23 105500 OWNER’S MANUAL OBSERVED PROBLEM Burner does not light after pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial operation Heater produces a whistling noise when burner is lit Glass soots Fireplace produces a clicking/ticking noise just after burners are lit or shut off Remote does ...

  • Vanguard Heating SBVBP(A) - page 24

    24 ® B -VENT FREEST ANDING FIREPLACE 105500 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’ s phone. Follow the gas supplier ’ s instructions ...

  • Vanguard Heating SBVBP(A) - page 25

    25 105500 OWNER’S MANUAL SER VICE HINTS When Gas Pressure is Too Low: • pilot will not stay lit • burners will have delayed ignition • fireplace will not produce specified heat • propane/LP gas supply might be low (propane/LP units only) When Gas Quality is Bad: • pilot will not stay lit • burners will produce flames and soot • fire ...

  • Vanguard Heating SBVBP(A) - page 26

    26 ® B -VENT FREEST ANDING FIREPLACE 105500 SPECIFICA TIONS SBVBN(A) SBVBP(A) 17,000-24,000 Btu/h 16,000-22,000 Btu/h Gas Type Natural Propane/LP Ignition Piezo Piezo Manifold Pressure 3.5" w.c. 10.0" w.c. Minimum Inlet Supply Pressure 4.5" w.c. 11.0" w.c. Thermal Efficiency 70% 70% Dimension, Inches/mm (HxWxD) Fireplace* 27&qu ...

  • Vanguard Heating SBVBP(A) - page 27

    27 105500 OWNER’S MANUAL ACCESSORIES Purchase these fireplace accessories from your local dealer. If they can not supply these accessories, call DESA International’s Sales Department at 1-800-432-2382. for information. You can also write to the ad- dress listed on the back page of this manual. WALL MOUNTED THERMOSTAT CONTROL KIT GWMT1 (Not Show ...

  • Vanguard Heating SBVBP(A) - page 28

    28 ® B -VENT FREEST ANDING FIREPLACE 105500 ILLUSTRA TED PA R T S BREAKDOWN SBVBN(A) SBVBP(A) L O H I P I L O T O FF O N 24 17 18 19 21 23 -1 23-4 23-2 23-3 26 27 4 22 9 4 1 10 11 8 2 4 4 7 28 13 14 15 16 20 20 25 5 29 3 12 6 ...

  • Vanguard Heating SBVBP(A) - page 29

    29 105500 OWNER’S MANUAL KEY NO. PART NUMBER DESCRIPTION QTY. 1 105479-01BR Firebox Assembly 1 2 M11084-26 Screw, Hex 2 3 105484-01CK Rear Cover 1 4 M11084-39 Screw, Hex 12 5 103587-02CK Switch Plate 1 6 099998-01 On/Off Switch 1 7 103284-04 Wire Harness 1 8 103284-06 Wire Harness 1 9 105812-01BR Baffle 1 10 105494-01 Spillswitch 1 11 M11084-43 S ...

  • Vanguard Heating SBVBP(A) - page 30

    30 ® B -VENT FREEST ANDING FIREPLACE 105500 ILLUSTRA TED PA R T S BREAKDOWN AMITY ™ SCIVF(*) SERIES PSCIVF(*) SERIES (* Indicates Color Suffix Designation) 1 2 5 8 7-4 6 5 5 7-1 7-2 5 4 7-3 3 AMITY ™ STOVE CHASSIS ...

  • Vanguard Heating SBVBP(A) - page 31

    31 105500 OWNER’S MANUAL P ARTS LIST AMITY ™ SCIVF(*) SERIES PSCIVF(*) SERIES (* Indicates Color Suffix Designation) This list contains replaceable parts used in your stove. When ordering parts, follow the instructions listed under Replacement Parts on page 25 of this manual. * Included In Hardware Kit KEY PART NO. NO. DESCRIPTION QTY. 1 104171 ...

  • Vanguard Heating SBVBP(A) - page 32

    LIMITED WARRANTY B-VENT FREESTANDING FIREPLACE AND AMITY ™ STOVE CHASSIS DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To ...

Manufacturer Vanguard Heating Category Indoor Fireplace

Documents that we receive from a manufacturer of a Vanguard Heating SBVBP(A) can be divided into several groups. They are, among others:
- Vanguard Heating technical drawings
- SBVBP(A) manuals
- Vanguard Heating product data sheets
- information booklets
- or energy labels Vanguard Heating SBVBP(A)
All of them are important, but the most important information from the point of view of use of the device are in the user manual Vanguard Heating SBVBP(A).

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Vanguard Heating SBVBP(A), service manual, brief instructions and user manuals Vanguard Heating SBVBP(A). Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Vanguard Heating SBVBP(A).

A complete manual for the device Vanguard Heating SBVBP(A), how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Vanguard Heating SBVBP(A) by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Vanguard Heating SBVBP(A).

A complete Vanguard Heating manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Vanguard Heating SBVBP(A) - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Vanguard Heating SBVBP(A), FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Vanguard Heating SBVBP(A), that we can find in the current document
3. Tips how to use the basic functions of the device Vanguard Heating SBVBP(A) - which should help us in our first steps of using Vanguard Heating SBVBP(A)
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Vanguard Heating SBVBP(A)
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Vanguard Heating SBVBP(A) in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Vanguard Heating SBVBP(A)?

Use the form below

If you did not solve your problem by using a manual Vanguard Heating SBVBP(A), ask a question using the form below. If a user had a similar problem with Vanguard Heating SBVBP(A) it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)