    OPERATING AND MAINTENANCE MANUAL FOR MARINE ELECTRIC WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL “ MSE ” ...

  • Hubbell Electric Heater Company MSE - page 2

    2 HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203) 378-2659 FAX: (203) 378-3593 INTERNET: http://www.hubbellheaters.com/ -- IMPORTANT -- Always reference the f ull model num ber and serial number when calling the factory. WARNING / CAUTION 1. Tank is to be complete ly fille d with water and a ll air is to be vente d bef ...

  • Hubbell Electric Heater Company MSE - page 3

    3 TABLE OF CONTENTS SECTION TITLE PAG E # I GENERAL DESCRI P TI ON AND CONSTRUCTION 5 II INSTAL LATI ON 10 III S C H E D U LE D M A IN TE NANC E AND OPERATION 14 I V TROUBL ES HOOTI NG 16 V SER VI CING AND REP LACEMENT OF PARTS 18 VI MI SCELL ANEOUS C HARTS AND FORMULAS 26 VI I ABS TYPE APPROVAL PROGRAM 28 ...

  • Hubbell Electric Heater Company MSE - page 4

    4 ...

  • Hubbell Electric Heater Company MSE - page 5

    5 SECTION I - GENERAL DESCRIPTION AND CONST RUCTION GENERAL DESCRIPTION This book describes a packaged electric water heater, approved by ABS Americas (A Division of the American Bureau of Shipping) and the USCG (United States Coast Guard), which is a stationary , self contained unit and is designed and constructed specifically for marine applicati ...

  • Hubbell Electric Heater Company MSE - page 6

    6 CONTROL THERMOS TAT The water heater is supplied with either a surface mounted or immersion thermostatic switch that is installed and wired at the factory . See drawing for specific details. The surface mounted thermostat can be adjusted through a range of 110° - 170° F . The immersion thermostat can be adjusted through a range of 100° - 190° ...

  • Hubbell Electric Heater Company MSE - page 7

    7 MAGNETIC CONTACTOR The magnetic contactor(s) is a heavy -duty resistive load ty pe rated for 100,000 cy cles. T he co nt act o r su ppl i es p ow er t o t he hea ti ng e le men t( s) and is si z ed b as ed on t he resistive load (non-inductive) rating of the circuit. The contactor supplies power on ly whe n t he t he rm os ta ti c s wit ch is en ...

  • Hubbell Electric Heater Company MSE - page 8

    8 Fused Low Voltage Transformer A fused low voltage transformer may be supplied. This option is used to step down higher voltages to 120-volt for the control circuit. Dial Temperature an d Pressure Gauge A combination temperature (70° - 250° F) and pressure (0 – 200 psi) gauge with 2½-inch dial may be supplied for in-line installation (shipped ...

  • Hubbell Electric Heater Company MSE - page 9

    9 On/Off Switch A built-in non-fused On/Off disconnect switch may be supplied with the control panel to disconnect power to the control panel control and power circuit wiring. Individually Fused Ele me nts To prevent the possibility of damage to circ uits and elements in case of electrical ove rloads, f uses ma y be supplied for each circuit. Two t ...

  • Hubbell Electric Heater Company MSE - page 10

    10 SECTION II – INSTALLATION WARNING / CAUTION DO NOT TURN ON THE ELECTRI C POWER SUPPL Y to this equipment until heate r is completely filled with water and all air ha s been released. I f the heater is NOT filled with water when the power is turned on, the heating elements will burn out. For protection against excessive pressures and temperatur ...

  • Hubbell Electric Heater Company MSE - page 11

    11 Mounting Dimensions Tank Diameter “A” Overall Diameter “B” Bolt Circle “C” Bulkhead Mounting Dimension “D” Gallon Capacity 16 20 12 None 10 16 20 12 None 20 16 20 12 None 30 16 20 12 12 40 18 3/4 22 3/4 16 12 50 22 26 16 12 65 22 26 16 12 80 24 28 18 12 100 24 28 18 12 120 ...

  • Hubbell Electric Heater Company MSE - page 12

    12 PIP ING INSTALLATION NOTE: The most effect ive means for preventing deteriorat ion from accelerated corrosi on due to galva nic and stray current is the installation of dielectric fittings/unions. The installation of these fittings is the responsibility of the installing contractor. 1. Connect the cold water inlet and hot water outlet to the app ...

  • Hubbell Electric Heater Company MSE - page 13

    13 ELECTRICAL IN STALLATION 1. Enter electric enclosure with properly siz ed feeder leads. Be sure to properly ground the water heater. 2. I nstall these power leads into the box lugs on the terminal block or magnetic contactor. 3. Torque screws per torque chart included in Section VI . 4. All other elect rical connections are m ade at the factory; ...

  • Hubbell Electric Heater Company MSE - page 14

    14 SECTION III - SCHEDULED MAINTE NANCE AND OPERATION WARNING / CAUTION Before performing any maintenance procedure, make certain power supply is OFF and cannot accidentally be turned on. MAINTENANCE AND OPERATION The water heater is automatic in its operation. I t will maintain a full tank of water at the temperature setting of the thermostat. The ...

  • Hubbell Electric Heater Company MSE - page 15

    15 ANNUAL INSPECTION 1. Flush tank as follows a. Shut off power supply . b. Close valve on hot water outlet piping. c. Open valve on drain piping. d. Cold water inlet line pressure will be strong enough to flush sediment from the bottom of the tank out through the drain. L et water run for 3-4 minutes. e. Close drain valve. f. Open hot water valve. ...

  • Hubbell Electric Heater Company MSE - page 16

    16 SECTION IV – TROUBLESHOOTING Symptom Probable Cause Corrective Action / Remedy Circuit breaker tripped at source. Reset circ uit breaker. On/Off switch in ‘OF F’ position, if installed. Turn switch to ‘ON’ position. Circuit breaker at control cabinet trippe d, if installed. Reset circ uit breaker. Blown fuse in element fuse block, if i ...

  • Hubbell Electric Heater Company MSE - page 17

    17 Faulty thermostat. Chec k thermostat adjustment. Monitor thermostat as described in S e ct i o n III, Q u a rt e r l y In s p e c t i on. Replace if necessary. Blown fuse in element fuse block, if installed. Replace fuse. Heating element not worki ng on all phases Check to see th at heating element is working on all phases, by checking the resis ...

  • Hubbell Electric Heater Company MSE - page 18

    18 SECTION V - SERVICING & REPLACEMENT OF PARTS WARNING / CAUTION Before servicing or replacing any part make sure to turn the power supply switch to the OF F position. SURFACE TEMPERATURE HIGH LIMIT CUT -OFF 1. Disconnect power from unit. 2. Remove access cover. 3. Disconnect the four (4) 14 gauge wires. Control Wires 4. Remove the two (2) mou ...

  • Hubbell Electric Heater Company MSE - page 19

    19 IMMERSION TEMPERATURE HIGH L IMIT CUT-OFF 1. Disconnect power from unit. 2. Remove access cover. 3. Remove high limit c over screw and cover. Cover Cover Screw Reset Switch 4. Disconnect the two (2) 14 gauge wires. Wires Capillary Tube 5. Remove capilla ry tube a nd bulb from thermowell 6. Remove two (2) mounting screws. Mounting Screws 7. Remov ...

  • Hubbell Electric Heater Company MSE - page 20

    20 HEATING ELEM ENT 1. Disconnect power from unit. 2. Shut off incoming water supply . 3. Attach hose to drain connection. 4. Lift manual release lever on relief valve to let air into sy stem or break union on outgoing water line. 5. Drain water from tank. 6. Disconnect the wires from the heating elem ent terminal s. 7. Remove the 3/8-16 nuts. Tank ...

  • Hubbell Electric Heater Company MSE - page 21

    21 ...

  • Hubbell Electric Heater Company MSE - page 22

    22 SURFACE MOUNTED THE RMOSTAT 1. Disconnect power from unit. 2. Remove access cover and locate t hermostat. 3. Disconnect the two (2) 14 gauge wires. Control Wires 4. Remove two (2) mounting screws. Mounting Screws 5. Replace thermost at using the reverse procedure. ...

  • Hubbell Electric Heater Company MSE - page 23

    23 IMMERSION THE RMOSTAT 1. Disconnect power from unit. 2. Remove access cover and locate t hermostat. 3. Remove high limit c over screw and cover. Cover Cover Screw 4. Disconnect the two (2) 14 gauge wires. Wires Capillary Tube 5. Remove capilla ry tube a nd bulb from thermowell. 6. Remove two (2) mounting screws. Mounting Screws 7. Replace thermo ...

  • Hubbell Electric Heater Company MSE - page 24

    24 MAGNETIC CONTACTOR 1. Disconnect power from unit. 2. Disconnect line and load wires to contactor. 3. Disconnect two (2) 14 gaug e control circuit wires. Control Wires Line Wires Load Wires 4. Loosen two (2) holding screws and remove contactor. Mounting Screws (Bottom screw not shown) 5. Replace with new contactor usi ng reverse procedure. ...

  • Hubbell Electric Heater Company MSE - page 25

    25 RELIEF VALVE 1. Disconnect power from unit. 2. Shut off incoming water supply . 3. Lift test lever on relief valve to relieve pressure in tank. 4. Disconnect overflow piping. 5. Unscrew relief valve, remove assemb ly and repl ace with new one. 6. Connect overflow piping. 7. Turn on incoming water supply and check for leaks. 8. Turn safety switch ...

  • Hubbell Electric Heater Company MSE - page 26

    26 SECTION VI – MISCELL ANEOUS CHARTS AND FORMULAS ELEMENT CHA RT Resistance (Ohms) Element Part # I mmersion L ength Hairpin 1 Φ 3 Φ DELTA 3 Φ WYE 2-38683N 13" 57.6 19.2 57.6 38.6 3-38683N 13" 43.2 14.4 43.2 28.9 4-38683N 13" 34.4 11.5 34.4 23.0 5-38683N 13" 27.9 9.3 27.9 18.7 6-38683N 13" 21.6 7.2 21.6 14.5 7-38683N ...

  • Hubbell Electric Heater Company MSE - page 27

    27 TORQUE VALUE S BOLT SIZE 18-8 S/S IN. - LB S . BRASS IN. - LB S . SI LI CON BRONZE IN. - LB S . ALUMI NUM 2024-T4 IN. - LB S . 316 S/S IN. - LB S . MONEL IN. - LB S . 4-40 5.2 4.3 4.8 2.9 5.5 5.3 4-48 6.6 5.4 6.1 3.6 6.9 6.7 5-40 7.7 6.3 7.1 4.2 8.1 7.8 5-44 9.4 7.7 8.7 5.1 9.8 9.6 6-32 9.6 7.9 8.9 5.3 10.1 9.8 6-40 12.1 9.9 11.2 6.6 12.7 12.3 8 ...

  • Hubbell Electric Heater Company MSE - page 28

    28 SECTION VII – ABS TYPE APPROVAL P ROGRAM ...

  • Hubbell Electric Heater Company MSE - page 29

    29 ...

  • Hubbell Electric Heater Company MSE - page 30

    30 ...

  • Hubbell Electric Heater Company MSE - page 31

    31 ...

  • Hubbell Electric Heater Company MSE - page 32

    32 ...

Manufacturer Hubbell Electric Heater Company Category Water Heater

Documents that we receive from a manufacturer of a Hubbell Electric Heater Company MSE can be divided into several groups. They are, among others:
- Hubbell Electric Heater Company technical drawings
- MSE manuals
- Hubbell Electric Heater Company product data sheets
- information booklets
- or energy labels Hubbell Electric Heater Company MSE
All of them are important, but the most important information from the point of view of use of the device are in the user manual Hubbell Electric Heater Company MSE.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Hubbell Electric Heater Company MSE, service manual, brief instructions and user manuals Hubbell Electric Heater Company MSE. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Hubbell Electric Heater Company MSE.

A complete manual for the device Hubbell Electric Heater Company MSE, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Hubbell Electric Heater Company MSE by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Hubbell Electric Heater Company MSE.

A complete Hubbell Electric Heater Company manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Hubbell Electric Heater Company MSE - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Hubbell Electric Heater Company MSE, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Hubbell Electric Heater Company MSE, that we can find in the current document
3. Tips how to use the basic functions of the device Hubbell Electric Heater Company MSE - which should help us in our first steps of using Hubbell Electric Heater Company MSE
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Hubbell Electric Heater Company MSE
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Hubbell Electric Heater Company MSE in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Hubbell Electric Heater Company MSE?

Use the form below

If you did not solve your problem by using a manual Hubbell Electric Heater Company MSE, ask a question using the form below. If a user had a similar problem with Hubbell Electric Heater Company MSE it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)