Manual John Mills KM39767

16 pages 2.46 mb
Download

Go to site of 16

Summary
  • John Mills KM39767 - page 1

    The company has a policy of continuous research and development and reserves the right to a mend without no tice the sp ecifica tion and de sign of all produ cts illus trated in th is catalo gue. John G uest Speedfit r eser ve the righ t to change th e colour an d shape of pr oduct s. Photog raphs ar e for illu stration purposes o nly . Subject to ...

  • John Mills KM39767 - page 2

    THE PU SH- FIT SO LUT ION F OR PLUM BIN G AND HE A TI NG SYS TEM S JG Speedfit is a push-fit system suitable for the plumbing of normal domestic hot and cold water services and central heating applications, including pressurised and combi systems. Speedfit Fittings have been designed for use with both Speedfit and copper pipe. Extensive tests have ...

  • John Mills KM39767 - page 3

    • Installation time reduced by up to 40% • Pipe flexibility permits the cabling of pipe through less accessible areas • No risk of fire or flames from a blowtorch • Easier to work in confined places • A permanent leak-proof connection • Corrosion free • No scale build up • Lower thermal diffusivity maintains safer surface temperatur ...

  • John Mills KM39767 - page 4

    HOW SPEEDFIT WORKS Grips before it seals Main ʻOʼ Ring Seal Stainless steel teeth grip the pipe Pipe insert gives secondary seal Speedfit Fittings have a unique grip then seal construction made up of a collet with stainless steel teeth to grip the pipe and an ‘O’ ring to provide a permanent leak proof seal. Use of the Superseal Pipe Insert en ...

  • John Mills KM39767 - page 5

    Use a collet cover or collet clip to provide added security against pipe disconnection, e.g. the fitting coming into contact with rigid surfaces and behind dry-lining walls. Collet covers for use with standard Speedfit fittings, are available in white or in red or blue to allow colour coding of pipes. Stops are located at the following distances fr ...

  • John Mills KM39767 - page 6

    PLUM BIN G FITTING S P ART N O . S IZE MM P ART N O .S IZE MM Suitable for central heating systems. P ART N O .S IZE MM PEM0410W 10 PEM0415W 15 PEM0422W 22 PEM0428W 28 Suitable for central heating systems. PEM201510W 15 x 10 PEM202215W 22 x 15 Suitable for central heating systems. P ART N O .S IZE MM JG601B 20 x 15 JG603B 25 x 15 JG602B 25 x 22 Col ...

  • John Mills KM39767 - page 7

    FLX43P 15 x 1/2" FLX34P 10 x 1/2" FLX35P 15 x 3/8" FLX15P 15 x 1/2" FLX16P 15 x 3/4" FLX22P 22 x 3/4" FLX18P 15 x 1/2" FLX20P 15 x 3/4" FLX19P 22 x 3/4" FLX23 Full Bore 22 x 3/4" FLX40 15 x 1/2" FLX42 15 x 3/4" FLX41 22 x 3/4" Not suitable for central heating systems. Hot and Cold wat ...

  • John Mills KM39767 - page 8

    V AL VE S P ART N O .S IZE MM 15 ESOT 15 P ART N O .S IZE 15 APT 15mm x 3/4" BSP Not suitable for central heating systems. Hot and Cold water only , 65°C maximum. For torque figures on plastic threads please see T echnical Checklist. Not suitable for central heating systems. Hot and Cold water only , 65°C maximum. P ART N O .S IZE MM 15STV 1 ...

  • John Mills KM39767 - page 9

    W ater -replenishing ring mains are typically used in hotels and hospitals. They are maintained at a constant high temperature to supply hot water to distribution pipes to wards or hotel rooms which may be some way from the heat source. These systems are very different from more conventional domestic hot water and central heating systems. Speedfit ...

  • John Mills KM39767 - page 10

    The Speedfit range includes a Double Check V alve (Part No 15DCV) to enable installers to comply with W ater Regulation Schedule 2.15, thus preventing contamination of water arising from back siphonage, backflow or cross connection. Washer Hole dia. 15mm pipe 29mm 22mm pipe 36mm 28mm pipe 46mm Cold water tank The minimum distance to make a solder c ...

  • John Mills KM39767 - page 11

    There are two types of pipe clip in the Speedfit range. Firstly , a nail clip is used for fixing to timber when running concealed pipe work i.e. underfloor or in a roof space . This clip takes less time to fit and is compact which allows pipework to be fixed close together when space is at a premium. Pipe clips should not be fitt ed any closer than ...

  • John Mills KM39767 - page 12

    When used in locations vulnerable to rodent attack, all plastic pipes and fittings should be adequately protected within sealed ducts. Speedfit pr oducts along with other materials such as electrical cables may be damaged if rodents are present. If vermin infestation is suspected then a r odent exterminator should take appropriate action . No taste ...

  • John Mills KM39767 - page 13

    SPEEDFIT SYSTEM COMPONENTS Speedfit Underfloor Heating Products have been designed and are manufactured to Eur opean and UK Standards, including ISO 9001 and DIN4726. Speedfit Manifolds are manufactured from high quality DZR brass to the highest UK and European standards. A unique feature is that connections to the heating pipes are Speedfit Push F ...

  • John Mills KM39767 - page 14

    The control unit has integral ball valves to allow for isolation from the primary heating system, an adjustable blending valve and a 6 metre head circulation pump. An anti-vibration mounting bracket ensures silent operation. Speedfit push in connections make for a fast connection to pipework. Speedfit recommend connection to the main central heatin ...

  • John Mills KM39767 - page 15

    UNDE RGR OUND FITTING S Speedfit underground fittings for metric size polyethylene cold water service pipe have been designed f or connection of: 1. Blue MDPE pipes to BS 6572 - used for underground service pipes for potable water . 2. Black MDPE pipes to BS6730 - used for conveyance of potable water above ground or for industrial services above or ...

  • John Mills KM39767 - page 16

    Fittings and pipe should be kept clean and undamaged before use. • Sizes. 10mm to 28mm diameter . • Pipes. Speedfit fittings can be used with: Copper pipe to BS EN 1057 Speedfit Barrier Pipe to BS7291. Speedfit fittings cannot be used on stainless steel pipe. • Standards. Speedfit products are designed and manufactured under a fully integrate ...

Manufacturer John Mills Category Plumbing Product

Documents that we receive from a manufacturer of a John Mills KM39767 can be divided into several groups. They are, among others:
- John Mills technical drawings
- KM39767 manuals
- John Mills product data sheets
- information booklets
- or energy labels John Mills KM39767
All of them are important, but the most important information from the point of view of use of the device are in the user manual John Mills KM39767.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals John Mills KM39767, service manual, brief instructions and user manuals John Mills KM39767. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product John Mills KM39767.

A complete manual for the device John Mills KM39767, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use John Mills KM39767 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of John Mills KM39767.

A complete John Mills manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual John Mills KM39767 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the John Mills KM39767, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the John Mills KM39767, that we can find in the current document
3. Tips how to use the basic functions of the device John Mills KM39767 - which should help us in our first steps of using John Mills KM39767
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with John Mills KM39767
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of John Mills KM39767 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning John Mills KM39767?

Use the form below

If you did not solve your problem by using a manual John Mills KM39767, ask a question using the form below. If a user had a similar problem with John Mills KM39767 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)