    CG-1309 REV C FEB 2006 OPERATION & MAINTE NANCE MANUAL UP/DN CONVERTER L-BAND LT-3600 SERIES 1915 Harrison Road Longview, Texas 75604 EXPORT CONTROL WARNING - Do not disclose this document or its contents to non-U.S. Persons, o r transmit this docum ent or its con tents outside th e United States without the written permission of Vertex Communi ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 2

    Integrated L-Band Up/Dn Conve rter LT3600 CG-130 9 Page 2 WARRANTY VertexRSI warrants its products for a peri od of two (2) years from the date of shipment to be free from defects caused by faulty materials or poor workmanship. The terms and conditions of this warranty are as follows • The purchaser must notify VertexRSI pr omptly upon discovery ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 3

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 3 TABLE OF CONTENTS Section 1 General Information ................................................................................................ 6 1.0 Introduction ............................................................................................................... ............... ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 4

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 4 Section 4 Serial Command Set .............................................................................................. 20 4.0 General .................................................................................................................................... 20 4.1 LT-3600 Seria ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 5

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 5 APPENDICES A Technical Manual Revision History ....................................................................................... 26 B CCA Software Revision History ............................................................................................. 26 C Display Panel Softwa re ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 6

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 6 SECTION 1 General Information 1.0 INTRODUCTION This manual contains installation, operation, and maintenance information for th e Integrated L-Band Up/Dn Converter manufactured by VertexRSI, Longview, Tx. Information is organized according to section. Within each section the pages, figures a ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 7

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 7 1.4 SPECIFICATIONS The specifications for the Integrated L-Band Up/Dn Converter are listed in Table 1-1, along with the mechanical dimensions. 1.5 FRONT PANEL All the operating controls and indicators for the Integrated L-Band Up/Dn Converter are located on the front panel. The front panel i ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 8

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 8 1.8 Part Number Configuration The Part Number Selection Chart shows configurati on options that are set at the factory prior to shipment. The voltage output to J4 and J10 may be changed as required by the customer, however this requires removal of the cove r and resetting internal jum per co ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 9

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 9 Table 1-1 Integrated L-Band Specifications UPCONVERTER Input Frequency Range 50 to 90 MHz Input Impedance 50 Ohms Input Level Range -20 to -40 dBm Output Frequency Range 950 to 1525 MHz 950 to 1950 MHz (Optional) Output Impedance 50 Ohms Output Return Loss 18dB Conversion Gain 10 to 30 dB (0 ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 10

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 10 Table 1-1 Integrated L-Band Specifications OPTIONAL INTERNA L REFERENCE Reference Frequency 10.000 MHz Stability (0 to +50 °C) + 2 x 10 -8 Aging per Day + 1 x 10 -9 Output Level (rear panel) + 12 dBm + 2 dB Phase Noise @ 10 Hz -115 dBc/Hz 1 00 Hz -135 dBc/Hz 1 kHz -145 dBc/Hz 1 0 kHz < ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 11

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 11 Table 1-1 Integrated L-Band Specifications INTERFACE AND CONNECT ORS Voltage (auto-ranging) 115/230 VAC + 15% Internal Electronics (Power) 25 watts StarSwitch Interface Connectors (Options) DB-15 (Female) Remote Serial Interface: Standard: RS-422/RS-485 (J7) DB-9 (Male) External SSPB Monito ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 12

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 12 SECTION 2 Installation 2.0 INTRODUCTION This section defines th e installation require- ments by which the Integrated L-Band Up/Dn Converter will meet the published specifications. 2.1 UNPACKING AND INSPE CTION Remove the unit from its shipping container and inspect for any damage sustained ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 13

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 13 2.4.6 External 10 MHz Input (J2) This connector is a BNC female. The male mate (not supplied) should be compatible with the 50-ohm coax used to connect to the system. 2.4.7 SSPB Interface (J6) This connector is a 9-pi n female miniature type “D” connector with standard #4-40 female scre ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 14

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 14 SECTION 3 Operation 3.0 INTRODUCTION The Up/Down Converter can be controlled from the front panel or remotely via a serial bus located on the rear panel of the converter. Various menus are available for EDIT and DISPLAY purposes. See Figure 3-2 for a listing of the menus. Section 4 gives a ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 15

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 15 Figure 3-2 Menu Listing RefOsc: OK Ofst:127 Slope Factor: 0 dB Unit Address: xx xx = 422 Mode Brd SN 1234 20/12/04 S/W:v7.70 Temp: 32 C Front Panel SW v 5.20 FP Alarm Tone: On UC 1200.000 +25.0 dB DC 1300.000 +35.0 dB UC: Ovr State: On DC: Low State: Muted UC Lvl: +1 dBm DC Lvl: -25 dBm SSP ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 16

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 16 Figure 3-3 Satellite Memory UC 0950.000 +10.0 dB DC 1525.000 +30.0 dB HIT ANY KEY (0-9) Example (KEY 0) EDIT ENT ENTER KEY RECALLS MEMORY TO ACTIVE UC0 1200.000 +20.0 dB DC0 1200.000 +30.0 dB ESCAPES TO ADJACENT MENU WITHOUT RECALL CONFIRM AND STORE CHANGE TO EACH FIELD AND LEAVE EDIT MODE ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 17

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 17 3.1 StarSwitch Operation The LT3600 UP/DOWN Converter may be used in conjunction with the StarSwitch to provide redundancy switch over operations if configured as StarSwitch Ready. The following modes of operation may be selected. 3.1.1 Auto Mode Upon reaching the StarSwitch Menu the inform ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 18

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 18 3.1.4 Backup Converter Operation The Backup Converter must be programmed to store all of the Converter Fre quencies and Gains in the system, in its Satellite Memory Locations, correspondi ng to the Converter Num ber (1 to 8) labeled on the StarSwitch Interface cables. Figure 3-7 show s the ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 19

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 19 3.2 Front Panel Alarm Settings Menu Page Acti ve Modes Mask (Default) Comment 1) Starswitch Auto ON STBY Auto Must select "Auto" Mode when Starswitch is not present. Forces summary alarm to OFF (see Stars witch operation). Forces summary alarm to ON (see Sta rswitch operation). 2) ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 20

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 20 SECTION 4 Serial Command Set 4.0 GENERAL The standard Up/Dn Converter is controlled via a rear panel seri al link (RS-422/485)(Reconfigurable to RS-232). With the front panel control, a user can operate the L-Band Up/Dn Converter from its front panel as well as from the serial link. This se ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 21

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 21 4.3 COMMANDS 4.3.1 Set UP/Converter Frequency {aaC1xxxxx} Where xxxx(x) = First 4 numeric data characters Range: 0950 to 1525 (MHz) for Std. Band units Range: 0950 to 1950 (MHz) for Extended Band units Where (xxxx)x = Fifth character is fractional MHz as follows 0 = 0.0 MHz 1 = +0.125 MHz 2 ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 22

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 22 4.3.7 DOWN/Converter (LNB) Spectrum Control {aaC7x} Where x = 0 for Non-Inverting spectrum and x = 1 for Inverting spectrum 4.3.8 UP/Converter Spectrum Control {aaC7TXz} Where z = 0 for Non-Inverting spectrum and z = 1 for Inverting spectrum 4.3.9 SSPB Band Control {aaC8x} Where x = 0 for S ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 23

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 23 4.4 STATUS REQUESTS 4.4.1 Command Status {aaS1} Returns: {aaS1bbbbccccddddeeeefffUL} Where bbbb = Up/Converter Frequency (as above) cccc = Down/Converter Frequency (as above) dddd = Up/Converter Gain eeee = Down/Converter Gain fff = Ref. Osc. Offset U = 0 for Non-Inverting Up/Converter, 1 f ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 24

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 24 4.4.4 L-Band Status {aaS3} Returns: {S3bbCddTReeN} Where: bb = 2 Chars., LNB current Detection Range: 00 to 99 ( 0 - 990 mA) C = 1 Character, SSPB Band Control Range: 0 = low band, 1 = high band dd = 2 Characters, SSPB Gain Range: –8 to –0 or ++ (dB) ++ = Full On T = 1 Character, Up/Con ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 25

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 25 4.4.9 Query Card Type {aaZ} Returns: {aaZxx} Where: xx = L-Band Card Type (1 – 8) 10 = 70 MHz IF, Std. Band Unit (SBU) 20 = 140 MHz IF, SBU 11 = 70 MHz IF, Ext Band Unit (EBU) 21 = 140 MHz IF, EBU 50 = 70 MHz IF, SBU with Inv. Up/Converter Spectrum 60 = 140 MHz IF, SBU with Inv. Up/Conver ...

  • General Dynamics UP/DN CONVERTER L-BAND - page 26

    Integrated L-Band Up/Dn Conve rter LT 3600 CG-1309 Page 26 Appendix A Manual Revision Hist ory C – Add Starsw menu M. Neely 2-03-05 D. Snyder 2-03-05 6323 B – Add Satellite Menu Info M. Neel y 10-14-05 D. Snyder 10-5-05 6129 A – Gain signs M. Neely 8-15-05 D. Snyder 8-15-05 6020 - Original Release M. Neely 11-5-04 D. Snyder 11-5-04 5442 Rev. ...

Manufacturer General Dynamics Category Network Hardware

Documents that we receive from a manufacturer of a General Dynamics UP/DN CONVERTER L-BAND can be divided into several groups. They are, among others:
- General Dynamics technical drawings
- UP/DN CONVERTER L-BAND manuals
- General Dynamics product data sheets
- information booklets
- or energy labels General Dynamics UP/DN CONVERTER L-BAND
All of them are important, but the most important information from the point of view of use of the device are in the user manual General Dynamics UP/DN CONVERTER L-BAND.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals General Dynamics UP/DN CONVERTER L-BAND, service manual, brief instructions and user manuals General Dynamics UP/DN CONVERTER L-BAND. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product General Dynamics UP/DN CONVERTER L-BAND.

Similar manuals

A complete manual for the device General Dynamics UP/DN CONVERTER L-BAND, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use General Dynamics UP/DN CONVERTER L-BAND by users. Manuals are usually written by a technical writer, but in a language understandable to all users of General Dynamics UP/DN CONVERTER L-BAND.

A complete General Dynamics manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual General Dynamics UP/DN CONVERTER L-BAND - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the General Dynamics UP/DN CONVERTER L-BAND, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the General Dynamics UP/DN CONVERTER L-BAND, that we can find in the current document
3. Tips how to use the basic functions of the device General Dynamics UP/DN CONVERTER L-BAND - which should help us in our first steps of using General Dynamics UP/DN CONVERTER L-BAND
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with General Dynamics UP/DN CONVERTER L-BAND
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of General Dynamics UP/DN CONVERTER L-BAND in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning General Dynamics UP/DN CONVERTER L-BAND?

Use the form below

If you did not solve your problem by using a manual General Dynamics UP/DN CONVERTER L-BAND, ask a question using the form below. If a user had a similar problem with General Dynamics UP/DN CONVERTER L-BAND it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)