Manual FieldServer FS-8700-17

28 pages 0.63 mb
Download

Go to site of 28

Summary
  • FieldServer FS-8700-17 - page 1

    A Sierra Monitor Company APPLICABILITY & EFF ECTIVITY Effective for all system s manufac tured after Januar y 1, 1999 Instruction Manual Part Num ber FS-8700-01 2/18/2004 Rev: 1.2 Driver Manual (Supplement to the FieldServer Instruction Manual) FS-8700-17 Optomux ...

  • FieldServer FS-8700-17 - page 2

    FS-8700-17 Optomux Driver Manual FieldServer Technologies 1991 Tarob Court, Milpitas, California 95035 (408 ) 262-2299 fax: (408) 2 62-9042 Visit our website: www.fieldserver.com E-mail: support@fieldserver.com Page Index TABLE OF CONTENTS 1 Optomux Driver Description ................................................................................. ...

  • FieldServer FS-8700-17 - page 3

    FS-8700-17 Optomux Driver Manual FieldServer Technologies 1991 Tarob Court, Milpitas, California 95035 (408 ) 262-2299 fax: (408) 2 62-9042 Visit our website: www.fieldserver.com E-mail: support@fieldserver.com Page 1 1 Optomux Driver Description The Optomux Driver allows the FieldServer to transfer data to and from devices over either RS-232 or RS ...

  • FieldServer FS-8700-17 - page 4

    FS-8700-17 Optomux Driver Manual FieldServer Technologies 1991 Tarob Court, Milpitas, California 95035 (408 ) 262-2299 fax: (408) 2 62-9042 Visit our website: www.fieldserver.com E-mail: support@fieldserver.com Page 2 2 Driver Scope of Supply 2.1 Supplied by FieldServer Technologies for this driver Driver Manual. 2.2 Provided by user Optomux System ...

  • FieldServer FS-8700-17 - page 5

    FS-8700-17 Optomux Driver Manual FieldServer Technologies 1991 Tarob Court, Milpitas, California 95035 (408 ) 262-2299 fax: (408) 2 62-9042 Visit our website: www.fieldserver.com E-mail: support@fieldserver.com Page 3 3 Hardware Connections The FieldServer is connected to the OPTO22 device as shown below. Configure the OPTO22 device according to ma ...

  • FieldServer FS-8700-17 - page 6

    FS-8700-17 Optomux Driver Manual FieldServer Technologies 1991 Tarob Court, Milpitas, California 95035 (408 ) 262-2299 fax: (408) 2 62-9042 Visit our website: www.fieldserver.com E-mail: support@fieldserver.com Page 4 4 Configuring the FieldServer as a Optomux Driver Client For a detailed discussion on FieldServer configuration, please refer to the ...

  • FieldServer FS-8700-17 - page 7

    FS-8700-17 Optomux Driver Manual FieldServer Technologies 1991 Tarob Court, Milpitas, California 95035 (408 ) 262-2299 fax: (408) 2 62-9042 Visit our website: www.fieldserver.com E-mail: support@fieldserver.com Page 5 4.2 Client Side Connections Section Title Connectio ns Column Title Function Legal Values Port Specify which port the device is conn ...

  • FieldServer FS-8700-17 - page 8

    FS-8700-17 Optomux Driver Manual FieldServer Technologies 1991 Tarob Court, Milpitas, California 95035 (408 ) 262-2299 fax: (408) 2 62-9042 Visit our website: www.fieldserver.com E-mail: support@fieldserver.com Page 6 4.4 Client Side Map Descriptors 4.4.1 FieldServer Related Map Descriptor Parameters Column Title Function Legal Values Map_Descripto ...

  • FieldServer FS-8700-17 - page 9

    FS-8700-17 Optomux Driver Manual FieldServer Technologies 1991 Tarob Court, Milpitas, California 95035 (408 ) 262-2299 fax: (408) 2 62-9042 Visit our website: www.fieldserver.com E-mail: support@fieldserver.com Page 7 Da_Byte_Name* Name s a data array that the driver will use to store poll/query response status data. One data element is used per ma ...

  • FieldServer FS-8700-17 - page 10

    FS-8700-17 Optomux Driver Manual FieldServer Technologies 1991 Tarob Court, Milpitas, California 95035 (408 ) 262-2299 fax: (408) 2 62-9042 Visit our website: www.fieldserver.com E-mail: support@fieldserver.com Page 8 Opto22_trigger* An optional parameter. If used then set the value of this parameter to yes or no and the da_byte_name parameter must ...

  • FieldServer FS-8700-17 - page 11

    FS-8700-17 Optomux Driver Manual FieldServer Technologies 1991 Tarob Court, Milpitas, California 95035 (408 ) 262-2299 fax: (408) 2 62-9042 Visit our website: www.fieldserver.com E-mail: support@fieldserver.com Page 9 the functions provided in table 6.1. The parameter must be sp elled an d spaced exactly as provided in the table. Leading and traili ...

  • FieldServer FS-8700-17 - page 12

    FS-8700-17 Optomux Driver Manual FieldServer Technologies 1991 Tarob Court, Milpitas, California 95035 (408 ) 262-2299 fax: (408) 2 62-9042 Visit our website: www.fieldserver.com E-mail: support@fieldserver.com Page 10 4.4.4 Map Descriptor Example 1 – Read on/off Status In this example the on/off status of all module positions of the Optomux devi ...

  • FieldServer FS-8700-17 - page 13

    FS-8700-17 Optomux Driver Manual FieldServer Technologies 1991 Tarob Court, Milpitas, California 95035 (408 ) 262-2299 fax: (408) 2 62-9042 Visit our website: www.fieldserver.com E-mail: support@fieldserver.com Page 11 4.4.5 Map Descriptor Example 2 – Read On/Off Status (Data stored differently) This example reads the sa m e data as the previous ...

  • FieldServer FS-8700-17 - page 14

    FS-8700-17 Optomux Driver Manual FieldServer Technologies 1991 Tarob Court, Milpitas, California 95035 (408 ) 262-2299 fax: (408) 2 62-9042 Visit our website: www.fieldserver.com E-mail: support@fieldserver.com Page 12 4.4.6 Map Descriptor Example 3 – Command Response/Completion Status We use example 1 to show how it can b e m odified to get the ...

  • FieldServer FS-8700-17 - page 15

    FS-8700-17 Optomux Driver Manual FieldServer Technologies 1991 Tarob Court, Milpitas, California 95035 (408 ) 262-2299 fax: (408) 2 62-9042 Visit our website: www.fieldserver.com E-mail: support@fieldserver.com Page 13 4.4.7 Map Descriptor Example 4 – Triggered Action This example shows the elem ents necessary to generate a trigger ed poll. Even ...

  • FieldServer FS-8700-17 - page 16

    FS-8700-17 Optomux Driver Manual FieldServer Technologies 1991 Tarob Court, Milpitas, California 95035 (408 ) 262-2299 fax: (408) 2 62-9042 Visit our website: www.fieldserver.com E-mail: support@fieldserver.com Page 14 4.4.8 Map Descriptor Example 5 – Using Address and Length to tell the FieldServer which module positions to access. This example ...

  • FieldServer FS-8700-17 - page 17

    FS-8700-17 Optomux Driver Manual FieldServer Technologies 1991 Tarob Court, Milpitas, California 95035 (408 ) 262-2299 fax: (408) 2 62-9042 Visit our website: www.fieldserver.com E-mail: support@fieldserver.com Page 15 4.4.9 Map Descriptor Example 6 – Using a Mask to Address specific module positions There may be occasions whe n it is not su itab ...

  • FieldServer FS-8700-17 - page 18

    FS-8700-17 Optomux Driver Manual FieldServer Technologies 1991 Tarob Court, Milpitas, California 95035 (408 ) 262-2299 fax: (408) 2 62-9042 Visit our website: www.fieldserver.com E-mail: support@fieldserver.com Page 16 4.4.10 Map Descriptor Example 7 – Specifying Module Positions Dynamically Previous examples addressed module positions statically ...

  • FieldServer FS-8700-17 - page 19

    FieldServer Technologies 199 1 Tarob Co urt, Milpitas, Calif ornia 95035 (408 ) 262-2299 fax : (408) 26 2-9042 Visit our website: www. f ieldserver.com E-mail: support@fieldser ver.com Page 17 5 Configuring the FieldServer as a Optomux Server The FieldServer does not support the emulation of a n Optomux server at present. ...

  • FieldServer FS-8700-17 - page 20

    FS-8700-17 Optomux Driver Manual FieldServer Technologies 199 1 Tarob Co urt, Milpitas, Calif ornia 95035 (408 ) 262-2299 fax : (408) 26 2-9042 Visit our website: www. f ieldserver.com E-mail: support@fieldser ver.com Page 18 6 Driver Notes 6.1 Data_Array_Name, DA_Bit_Name, DA_Byte_Name These parameters are used to specify data array names. Despite ...

  • FieldServer FS-8700-17 - page 21

    FS-8700-17 Optomux Driver Manual FieldServer Technologies 199 1 Tarob Co urt, Milpitas, Calif ornia 95035 (408 ) 262-2299 fax : (408) 26 2-9042 Visit our website: www. f ieldserver.com E-mail: support@fieldser ver.com Page 19 255 the Optomux literature should be read for additional information as these are codes returned by the Optomux device. 128 ...

  • FieldServer FS-8700-17 - page 22

    FS-8700-17 Optomux Driver Manual FieldServer Technologies 199 1 Tarob Co urt, Milpitas, Calif ornia 95035 (408 ) 262-2299 fax : (408) 26 2-9042 Visit our website: www. f ieldserver.com E-mail: support@fieldser ver.com Page 20 Read/ Write/ Both COMMAND NAME OPTO22_FORMAT OPTION MASTER LENGTH CONSIDERED (See Notes) NOTES w POWER UP CLEAR 4 w RESET 4 ...

  • FieldServer FS-8700-17 - page 23

    FS-8700-17 Optomux Driver Manual FieldServer Technologies 199 1 Tarob Co urt, Milpitas, Calif ornia 95035 (408 ) 262-2299 fax : (408) 26 2-9042 Visit our website: www. f ieldserver.com E-mail: support@fieldser ver.com Page 21 Read/ Write/ Both COMMAND NAME OPTO22_FORMAT OPTION MASTER LENGTH CONSIDERED (See Notes) NOTES Specified) module positions g ...

  • FieldServer FS-8700-17 - page 24

    FS-8700-17 Optomux Driver Manual FieldServer Technologies 199 1 Tarob Co urt, Milpitas, Calif ornia 95035 (408 ) 262-2299 fax : (408) 26 2-9042 Visit our website: www. f ieldserver.com E-mail: support@fieldser ver.com Page 22 Read/ Write/ Both COMMAND NAME OPTO22_FORMAT OPTION MASTER LENGTH CONSIDERED (See Notes) NOTES affected. The Modifier (byte ...

  • FieldServer FS-8700-17 - page 25

    FS-8700-17 Optomux Driver Manual FieldServer Technologies 199 1 Tarob Co urt, Milpitas, Calif ornia 95035 (408 ) 262-2299 fax : (408) 26 2-9042 Visit our website: www. f ieldserver.com E-mail: support@fieldser ver.com Page 23 Read/ Write/ Both COMMAND NAME OPTO22_FORMAT OPTION MASTER LENGTH CONSIDERED (See Notes) NOTES r READ AND AVERAGE INPUT 4 On ...

  • FieldServer FS-8700-17 - page 26

    FS-8700-17 Optomux Driver Manual FieldServer Technologies 199 1 Tarob Co urt, Milpitas, Calif ornia 95035 (408 ) 262-2299 fax : (408) 26 2-9042 Visit our website: www. f ieldserver.com E-mail: support@fieldser ver.com Page 24 Read/ Write/ Both COMMAND NAME OPTO22_FORMAT OPTION MASTER LENGTH CONSIDERED (See Notes) NOTES affected by command. b READ A ...

  • FieldServer FS-8700-17 - page 27

    FS-8700-17 Optomux Driver Manual FieldServer Technologies 199 1 Tarob Co urt, Milpitas, Calif ornia 95035 (408 ) 262-2299 fax : (408) 26 2-9042 Visit our website: www. f ieldserver.com E-mail: support@fieldser ver.com Page 25 6.5 Driver Stats In addition to the standard FieldServer communication statistics de scribe d in the FieldServer User’s Ma ...

  • FieldServer FS-8700-17 - page 28

    FS-8700-17 Optomux Driver Manual FieldServer Technologies 199 1 Tarob Co urt, Milpitas, Calif ornia 95035 (408 ) 262-2299 fax : (408) 26 2-9042 Visit our website: www. f ieldserver.com E-mail: support@fieldser ver.com Page 26 7 Revision History Date Resp Format Driver Ver. Doc. Rev. Comment 2/18/04 JD MF 0 1 Releasi ng ...

Manufacturer FieldServer Category Computer Drive

Documents that we receive from a manufacturer of a FieldServer FS-8700-17 can be divided into several groups. They are, among others:
- FieldServer technical drawings
- FS-8700-17 manuals
- FieldServer product data sheets
- information booklets
- or energy labels FieldServer FS-8700-17
All of them are important, but the most important information from the point of view of use of the device are in the user manual FieldServer FS-8700-17.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals FieldServer FS-8700-17, service manual, brief instructions and user manuals FieldServer FS-8700-17. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product FieldServer FS-8700-17.

A complete manual for the device FieldServer FS-8700-17, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use FieldServer FS-8700-17 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of FieldServer FS-8700-17.

A complete FieldServer manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual FieldServer FS-8700-17 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the FieldServer FS-8700-17, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the FieldServer FS-8700-17, that we can find in the current document
3. Tips how to use the basic functions of the device FieldServer FS-8700-17 - which should help us in our first steps of using FieldServer FS-8700-17
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with FieldServer FS-8700-17
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of FieldServer FS-8700-17 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning FieldServer FS-8700-17?

Use the form below

If you did not solve your problem by using a manual FieldServer FS-8700-17, ask a question using the form below. If a user had a similar problem with FieldServer FS-8700-17 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)