Extron electronic SCP/AAP A - page 1
User ’ s Manual Extron Electronics, USA 1230 South Lewis Street Anaheim, CA 92805 USA 714.491.1500 Fax 714.491.1517 Extron Electronics, Europe Beeldschermweg 6C 3821 AH Amersfoort The Netherlands +31.33.453.4040 Fax +31.33.453.4050 Extron Electronics, Asia 135 Joo Seng R oad, #04-01 PM Industrial Building Singapore 368363 +65.6383.4400 Fax +65.63 ...
-
Extron electronic SCP/AAP A - page 2
Precautions This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product's enclosure that may present a risk of electric shock. Caution Read In ...
-
Extron electronic SCP/AAP A - page 3
i SCP/AAP A, SCP 200, SCP 250 • Table of Contents Chapter 1 • Introduction .......................................................... 1-1 About the SCP/AAP A, SCP 200, and SCP 250 .......... 1-2 Features ...................................................................................... 1-2 SCP 200 and SCP 250 feature ....................... ...
-
Extron electronic SCP/AAP A - page 4
ii SCP/AAP A, SCP 200, SCP 250 • Table of Contents T able of Contents, cont’d SCP/AAP A, SCP 200, SCP 250 1 Chapter One Intr oduction About the SCP/AAP A, SCP 200, and SCP 250 Features 68-511-01 Rev. B Printed in the USA 02 02 All trademarks mentioned in this manual are the pr operties of their r espective owners. ...
-
Extron electronic SCP/AAP A - page 5
SCP/AAP A, SCP 200, SCP 250 • Introduction Introduction, cont’d SCP/AAP A, SCP 200, SCP 250 2 Chapter T wo Installation and Operation Installation Overview Preparing the Site, Installing the Electrical Box Rear Panel Connectors and Switches Cabling Front Panel Features and Operation Testing/Troubleshooting Mounting the SCP to the Electrical Box ...
-
Extron electronic SCP/AAP A - page 6
SCP/AAP A, SCP 200, SCP 250 • Installation and Operation SCP/AAP A, SCP 200, SCP 250 • Installation and Operation Installation and Operation, cont’d Flush with W all Surface Screws or Nails W all Stud W all Box 2-3 Installation and Operation Installation Overview T o install and set up an SCP contr ol pad, follow these steps: 1 T urn the equi ...
-
Extron electronic SCP/AAP A - page 7
SCP/AAP A, SCP 200, SCP 250 • Installation and Operation SCP/AAP A, SCP 200, SCP 250 • Installation and Operation Installation and Operation, cont’d 2-5 Rear Panel Connectors and Switches 2-4 SCP 200 SW13 J1 J2 11 8 7 6 5 4 3 2 1 1 2 3 SCP 250 SW13 J2 J1 1 1 8 7 6 5 4 3 2 1 1 2 3 SCP/AAP A SW1 1 J3 J2 1 1 2 3 4 5 6 7 8 1 2 3 1 & 2 Communi ...
-
Extron electronic SCP/AAP A - page 8
SCP/AAP A, SCP 200, SCP 250 • Installation and Operation SCP/AAP A, SCP 200, SCP 250 • Installation and Operation Installation and Operation, cont’d Cabling For each SCP to be connected to a system switcher , set the r ea r panel DIP switches, then follow these steps: 1. If it hasn’t already been done when the wall box was installed, cut a ...
-
Extron electronic SCP/AAP A - page 9
SCP/AAP A, SCP 200, SCP 250 • Installation and Operation SCP/AAP A, SCP 200, SCP 250 • Installation and Operation Installation and Operation, cont’d 2-9 2-8 Signal, power , ground Signal, power , ground Signal, power , gr ound P ower , gr ound SYSTEM 7SC COMPUTER S-VIDEO LR VIDEO AUDIO S-VIDEO LR VIDEO INPUT 7 CONTROL IR DISPLAY VOLUME RX LEA ...
-
Extron electronic SCP/AAP A - page 10
SCP/AAP A, SCP 200, SCP 250 • Installation and Operation SCP/AAP A, SCP 200, SCP 250 • Installation and Operation Installation and Operation, cont’d Front Panel Featur es and Operation SCP 200 IR DISPLA Y POWER DISPLA Y MUTE MODE ROOM/ RELA Y 1 ROOM/ RELA Y 2 1 234567 2 5 6 4 6 SCP 250 IR DISPLA Y AUDIO VOLUME POWER MUTE MODE MAX/ MIN ROOM 1 ...
-
Extron electronic SCP/AAP A - page 11
SCP/AAP A, SCP 200, SCP 250 • Installation and Operation SCP/AAP A, SCP 200, SCP 250 • Installation and Operation Installation and Operation, cont’d T esting/T roubleshooting Befor e installing the control pad into the wall or furniture, test the system to make sure that the connections ar e correct and the SCP is working corr ectly . 1. Conn ...
-
Extron electronic SCP/AAP A - page 12
SCP/AAP A, SCP 200, SCP 250 • Installation and Operation Installation and Operation, cont’d SCP/AAP A, SCP 200, SCP 250 A Appendix A Specifications, Part Numbers, and Accessories Specifications Included Parts Accessories Cables 2-14 ...
-
Extron electronic SCP/AAP A - page 13
SCP/AAP A, SCP 200, SCP 250 • Specifications, Part Numbers SCP/AAP A, SCP 200, SCP 250 • Specifications, Part Numbers Specifications, Accessories, Part Numbers, cont’d A-3 Specifications A-2 Control/remote — control pads IR controller module ................... IR 701 (optional) General Power ............................................. 12 ...
-
Extron electronic SCP/AAP A - page 14
SCP/AAP A, SCP 200, SCP 250 • Specifications, Part Numbers Specifications, Accessories, Part Numbers, cont’d SCP/AAP A, SCP 200, SCP 250 B Appendix B Dimensions, T emplates, and Labels Panel Dimensions Templates Labeling Buttons on the SCPs Included Parts These items ar e included in each order for an SCP control pad: Included parts (SCP/AAP A) ...
-
Extron electronic SCP/AAP A - page 15
SCP/AAP A, SCP 200, SCP 250 • Dimensions, Templates, Labels SCP/AAP A, SCP 200, SCP 250 • Dimensions, Templates, Labels Dimensions, T emplates, and Labels, cont’d SCP 200 dimensions SCP 200 .100 THK. 'b' 'b' 'a' 'a' 'b' 'b' 'a' 'a' IR .500 0.06" RADIUS AROUND ...
-
Extron electronic SCP/AAP A - page 16
SCP/AAP A, SCP 200, SCP 250 • Dimensions, Templates, Labels SCP/AAP A, SCP 200, SCP 250 • Dimensions, Templates, Labels Dimensions, T emplates, and Labels, cont’d MILLED POCKET 0 .060 " DEEP WITH R 0.031 FILLET ON TOP EDGE. BORE ø 0.313 x 0.070 DEEP , FLA T BOTT OM, FR OM F AR SIDE (2 PLA CES) R .062 (4 PLA CES) .240 .371 .185 .166 .331 ...
-
Extron electronic SCP/AAP A - page 17
SCP/AAP A, SCP 200, SCP 250 • Dimensions, Templates, Labels SCP/AAP A, SCP 200, SCP 250 • Dimensions, Templates, Labels Dimensions, T emplates, and Labels, cont’d SCP 200 template This full-size template is a guide for cutting a hole for the 2-gang size electrical box for the SCP 200 or for the SCP 200 itself (if it will be installed directly ...
-
Extron electronic SCP/AAP A - page 18
SCP/AAP A, SCP 200, SCP 250 • Dimensions, Templates, Labels SCP/AAP A, SCP 200, SCP 250 • Dimensions, Templates, Labels Dimensions, T emplates, and Labels, cont’d B-9 Labeling Buttons on the SCPs The SCP 200 and SCP 250 have translucent panels (“windows”) behind which customized labels can be inserted. T o remove a panel, 1. Insert the he ...
-
Extron electronic SCP/AAP A - page 19
SCP/AAP A, SCP 200, SCP 250 • Dimensions, Templates, Labels SCP/AAP A, SCP 200, SCP 250 • Dimensions, Templates, Labels Dimensions, T emplates, and Labels, cont’d Label templates Below and on the following pages are full-sized templates for the labels. Feel free to photocopy them, write button information in each area of the blank templates a ...
-
Extron electronic SCP/AAP A - page 20
SCP/AAP A, SCP 200, SCP 250 • Dimensions, Templates, Labels SCP/AAP A, SCP 200, SCP 250 • Dimensions, Templates, Labels Dimensions, T emplates, and Labels, cont’d SCP 250 labels ROOM 1 For use with a System 7SC s witcher For use with a System 5 cr Plus switcher ROOM 2 4 123 7 56 ROOM 15 234 n/a n/a n/a B-13 This page is left intentionally bla ...
-
Extron electronic SCP/AAP A - page 21
SCP/AAP A, SCP 200, SCP 250 • Dimensions, Templates, Labels Dimensions, T emplates, and Labels, cont’d This page is left intentionally blank. B-14 ...
Do you have a question concerning Extron electronic SCP/AAP A?
Use the form below
If you did not solve your problem by using a manual Extron electronic SCP/AAP A, ask a question using the form below. If a user had a similar problem with Extron electronic SCP/AAP A it is likely that he will want to share the way to solve it.