  • Graco Inc. D 5 E - page 1

    Air–Operated Diaphragm Pumps For fluid transfer applications. For professional use only . Only models marked with (*) are approved for use in European explosive atmosphere locations. 100 psi (0.7 MPa, 7 bar) Maximum Fluid Working Pressure 100 psi (0.7 MPa, 7 bar) Maximum Air Input Pressure ACET AL, POL YPROPYLENE, AND PVDF Husky t 515 Model No. D ...

  • Graco Inc. D 5 E - page 2

    2 308981 T able of Contents Safety W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maintenance 1 1 . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Graco Inc. D 5 E - page 3

    3 308981 W ARNING TOXIC FLUID HAZARD Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.  Know the specific hazards of the fluid you are using.  Do not lift a pump under pressure. If dropped, the fluid section may rupture. Always follow the Pressure Relief Procedure o ...

  • Graco Inc. D 5 E - page 4

    4 308981 Installation General Information  The T ypical Installations in Fig. 2 are only guides for selecting and installing system components. Contact your Graco distributor for assistance in planning a system to suit your needs.  Always use Genuine Graco Parts and Accessories.  Use a compatible, liquid thread sealant on all male threads. ...

  • Graco Inc. D 5 E - page 5

    5 308981 Installation Air Line W ARNING A bleed-type master air valve (B) is required in your system to relieve air trapped between this valve and the pump. See Fig. 2. T rapped air can cause the pump to cycle unexpectedly , which could result in serious injury , including splashing in the eyes or on the skin, injury from moving parts, or contamina ...

  • Graco Inc. D 5 E - page 6

    6 308981 Installation Fluid Pressure Relief V alve CAUTION Some systems may require installation of a pressure relief valve at the pump outlet to prevent overpres- surization and rupture of the pump or hose. See Fig. 1. Thermal expansion of fluid in the outlet line can cause overpressurization. This can occur when using long fluid lines exposed to ...

  • Graco Inc. D 5 E - page 7

    7 308981 Installation KEY A Pump C Electrically conductive air supply line D Air line quick disconnect H Fluid drain valve (required) K Electrically conductive fluid supply hose L Fluid suction line Y Ground wire (required; see page 8 for installation instructions) 9074A Fig. 2 H J ABOVE-GROUND TRANSFER INST ALLA TION A C D K L M N Y E 9075A H 55-G ...

  • Graco Inc. D 5 E - page 8

    8 308981 Installation Grounding W ARNING FIRE AND EXPLOSION HAZARD This pump must be grounded. Before operating the pump, ground the system as explained below . Also read the sec- tion Fire and Explosion Hazard on page 3. The acetal Husky 515 pump contains stainless steel fibers, which makes the wetted parts conduc- tive. Attaching the ground wire ...

  • Graco Inc. D 5 E - page 9

    9 308981 Installation Changing the Orientation of the Fluid Inlet and Outlet Ports (Husky 515) Y ou can change the orientation of the fluid inlet and outlet ports by repositioning the manifolds. For Husky 515, see Fig. 4. For Husky 716, see Fig. 5. 1. Relieve the pressure. See Pres- sure Relief Procedure on page 10. 2. Remove the four manifold nuts ...

  • Graco Inc. D 5 E - page 10

    10 308981 Operation Pressure Relief Procedure W ARNING PRESSURIZED EQUIPMENT HAZARD The equipment stays pressurized until pressure is manually relieved. T o reduce the risk of serious injury from pressurized fluid, accidental spray , or splashing fluid, follow this procedure whenever you  Are instructed to relieve pressure  Stop pumping  C ...

  • Graco Inc. D 5 E - page 11

    11 308981 Maintenance Lubrication The air valve is lubricated at the factory to operate without additional lubrication. If you want to provide additional lubrication, remove the hose from the pump air inlet and add two drops of machine oil to the air inlet every 500 hours of operation or every month. CAUTION Do not over-lubricate the pump. Oil is e ...

  • Graco Inc. D 5 E - page 12

    12 308981 T roubleshooting Read Pressure Relief Procedure on page 10, and relieve the pressure before you check or service the equipment. Check all possible problems and causes before disassembling the pump. PROBLEM CAUSE SOLUTION Pump will not cycle, or cycles once and stops. Air valve is stuck or dirty . Use filtered air . Pump cycles at stall or ...

  • Graco Inc. D 5 E - page 13

    13 308981 Service Air V alve (Husky 515 and Husky 716 Pumps) NOTE: Air V alve Repair Kit 241657 is available. Parts included in the kit are marked with a dagger (  ) in Fig. 6 and in the Parts Drawings and Lists. A tube of general purpose grease 1 1 1920 is supplied in the kit. Service the air valve as follows. See Fig. 6. 1. Relieve the pressur ...

  • Graco Inc. D 5 E - page 14

    14 308981 Service Ball or Duckbill Check V alves NOTE: Fluid Section Repair Kit D05XXX is available. See page 22 to order the correct kit for your pump. Parts included in the kit are marked with a double dagger (  ) in Fig. 7 and Fig. 8 and in the Parts Draw- ings and Lists. General purpose grease 1 1 1920 and Adhesive 1 13500 are supplied in th ...

  • Graco Inc. D 5 E - page 15

    15 308981 Service Fig. 7 103  202 139  202  201  301  139  201  301  202   201  139 109 109 1 T orque to 80 t o 90 in- lb ( 9 to 10 N -m). See T orque Sequence , page 29. 1 1  202  201  139 9067A 102 Husky 515 139  139  139  201  202  Fig. 8  139  201 101  202  139  139  201 ...

  • Graco Inc. D 5 E - page 16

    16 308981 Service Diaphragms (Husky 515) NOTE: Fluid Section Repair Kit D05XXX is available. See page 22 to order the correct kit for your pump. Parts included in the kit are marked with a double dagger (  ) in Fig. 9 and in the Parts Drawings and Lists. General purpose grease 1 1 1920 and Adhesive 1 13500 are supplied in the kit. Service the di ...

  • Graco Inc. D 5 E - page 17

    17 308981 6. Put grease on the diaphragm shaft (15), and carefully (do not damage the shaft u-cups) run the diaphragm shaft (15) through the center housing (1 1) bore. 7. Repeat step 5 for the other end of the diaphragm shaft (15), and torque the fluid-side diaphragm plates (105) to 80 to 90 in-lb (9 to 10 N-m) at 100 rpm maximum. Overmolded Diaphr ...

  • Graco Inc. D 5 E - page 18

    18 308981 Service Diaphragms (Husky 515) Fig. 9 6  12  416 109 105 401  102 109 101 15 11 11 4 106 103  Included in Fluid Section Repair Kit D05XXX 1 2 T orque to 35 t o 45 in-lb (4.0 to 5.1 N-m). Apply grease. The words “AIR SIDE” on diaphragms (and on backup diaphragms required on PTFE models) must face toward diaphragm shaft (15) ...

  • Graco Inc. D 5 E - page 19

    19 308981 Service Diaphragms (Husky 716) NOTE: Fluid Section Repair Kit D05XXX is available. See page 22 to order the correct kit for your pump. Parts included in the kit are marked with a double dagger (  ) in Fig. 10 and in the Parts Drawings and Lists. General purpose grease 1 1 1920 and Adhesive 1 13500 are supplied in the kit. Service the d ...

  • Graco Inc. D 5 E - page 20

    20 308981 6. Put grease on the diaphragm shaft (15), and carefully (do not damage the shaft u-cups) run the diaphragm shaft (15) through the center housing (1 1) bore. 7. Repeat step 5 for the other end of the diaphragm shaft (15), and torque the diaphragm shaft screws (140) to 80 to 90 in-lb (9 to 10 N-m) at 100 rpm maximum. Overmolded Diaphragms: ...

  • Graco Inc. D 5 E - page 21

    21 308981 Service Diaphragms (Husky 716) Fig. 10 11  Included in Fluid Section Repair Kit D05XXX 1 2 T orque to 35 t o 45 in-lb (4.0 to 5.1 N-m). Apply grease. The words “AIR SIDE” on diaphragms (and on backup diaphragms used on PTFE models) must face toward diaphragm shaft (15). 3 4 Install with lips facing out of center housing (1 1) . Fla ...

  • Graco Inc. D 5 E - page 22

    22 308981 Husky 515 and Husky 716 Pump Matrix Y our Model No. is marked on the pump’s serial plate. T o determine a pump Model No. from the following matrix, select the six digits that describe the pump, working from left to right. The first digit is always D , designating Husky diaphragm pumps. The remaining five digits define the air motor type ...

  • Graco Inc. D 5 E - page 23

    23 308981 Additional Husky 515 and Husky 716 Pumps Model 241564, 515 pump Same as the D5121 1 pump, but with an open downward port. Model 241565, 515 pump Same as the D5291 1 pump, but with an open downward port. Model 248171, 515 pump Same as the D51277 pump, except with split inlets/outlets. Model 248172, 515 pump Same as the D51255 pump, except ...

  • Graco Inc. D 5 E - page 24

    24 308981 Husky 515 and Husky 716 Common Parts See the Pump Matrix on page 22 for an explanation of the Matrix Column and the Digit . Air Motor Parts List (Matrix Column 2) Digit Ref. No. Part N o. Description Qty 5 1  1 14866 P ACKING, o-ring 2 2  108808 P ACKING, u-cup 2 3 1 12933 MUFFLER 1 4  162942 P ACKING, o-ring 2 6 195025 PLA TE, d ...

  • Graco Inc. D 5 E - page 25

     202 6  12  9 11  1 4 13 3 14  4 8  7  2  10 15  416 106 grounding screw (acetal pump only) 139  202  201  301  139  201  301  202   201  139  139  202  201 11 5 101 109 105 401  11 4 106 11 3 101 11 6  Included in Air V alve Repair Kit 241657  Included in Fluid Section Repa ...

  • Graco Inc. D 5 E - page 26

    26 308981 Husky 515 Fluid Section Parts List See the Pump Matrix on page 22 for an explanation of the Matrix Column and the Digit . See page 24 for Air Motor Parts List (Matrix Column 2) Husky 515 Fluid Section Parts List (Matrix Column 3) Ref Acetal Pumps Digit: 1 (NPT) Digit: A (BSPT) Polypropylene Pumps Digit: 2 (NPT) Digit: B (BSPT) PVDF Pumps ...

  • Graco Inc. D 5 E - page 27

    139  11 4 13 10  416  139  201 134 4 15  1 109 101 102 102  202  139  301 108 11 2 11 2  401  402 103 11 7 105 105 106 106 107 6 133  11 5 Grounding Detail 121 122 123  9 8  7  2   Included in Air V alve Repair Kit 241657  Included in Fluid Section Repair Kit D05XXX * These parts are unique to the ...

  • Graco Inc. D 5 E - page 28

    28 308981 Husky 716 Fluid Section Parts List See the Pump Matrix on page 22 for an explanation of the Matrix Column and the Digit . See page 24 for Air Motor Parts List (Matrix Column 2) Husky 716 Fluid Section Parts List (Matrix Column 3) Ref Aluminum Pumps Digit: 3 (NPT) Digit: C (BSPT) Stainless Steel (sst) Pumps Digit: 4 (NPT) Digit: D (BSPT) R ...

  • Graco Inc. D 5 E - page 29

    29 308981 T orque Sequence Always follow torque sequence when instructed to torque fasteners. Husky 515 1. Left/Right Fluid Covers T orque bolts to 80–90 in–lb (9–10 N  m) 1 1 1 1 5 7 2 3 8 8 6 4 SIDE VIEW 2. Inlet Manifold T orque bolts to 80–90 in–lb (9–10 N  m) 11 9 10 12 BO TTOM VIEW 3. Outlet Manifold T orque bolts to 80–90 ...

  • Graco Inc. D 5 E - page 30

    30 308981 Husky 515 T echnical Data Maximum fluid working pressure 100 psi (0.7 MPa, 7 bar) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air pressure operating range 30 to 100 psi (0.2 to 0.7 MPa, 2.1 to 7 bar ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operating T emperature Range* Minimum ...

  • Graco Inc. D 5 E - page 31

    31 308981 Husky 515 Dimensions 1.38 in. (35.1 mm) FRONT VIEW SIDE VIEW 1/4 npt(f) Air Inlet 6.25 in. (158.8 mm) 7.75 in. (196.9 mm) PUMP MOUNTING HOLE P A TTERN 4.30 in. (109.2 mm) 3/4 npt(f) or bspt(f) Fluid Outlet * Four 0.30 in. (7.6 mm) Diameter Slots 5.01 in. (127 mm) 4.70 in. (1 19 mm) 10.63 in. (270.0 mm) 9.94 in. (252.5 mm) 8.56 in. (217.4 ...

  • Graco Inc. D 5 E - page 32

    32 308981 Husky 716 T echnical Data Maximum fluid working pressure 100 psi (0.7 MPa, 7 bar) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air pressure operating range 30 to 100 psi (0.2 to 0.7 MPa, 2.1 to 7 bar ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operating T emperature Range* Minimum ...

  • Graco Inc. D 5 E - page 33

    33 308981 Husky 716 Dimensions 1.38 in. (35.1 mm) FRONT VIEW SIDE VIEW 1/4 npt(f) Air Inlet 6.04 in. (153.4 mm) 7.37 in. (187.2 mm) PUMP MOUNTING HOLE P A TTERN Four 0.28 in. (7.1 mm) Diameter Slots 4.44 in. (1 12.8 mm) 4.25 in. (108.0 mm) 10.43 in. (264.9 mm) 9.18 in. (233.2 mm) 7.80 in. (198.1 mm) 6.62 in. (168.1 mm) 2.76 in. (62.5 mm) 4.29 in. ( ...

  • Graco Inc. D 5 E - page 34

    34 308981 Husky 515 and 716 Performance Charts 0 20 40 60 80 100 0246 8 1 0 1 2 1 4 1 6 (7.6) (15.2) (22.7) (30.3) (37.9) (45.4) (53.0) (60.6) Fluid Outlet Pressure T est Conditions: Pump tested in water with inlet submerged. T o find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow (gpm/lpm) and operating air pressure (psi/MPa/bar): 1. ...

  • Graco Inc. D 5 E - page 35

    35 308981 Husky 515 and 716 Performance Charts 0 5 10 15 20 25 30 0246 8 1 0 1 2 1 4 1 6 (7.6) (15.2) (22.7) (30.3) (37.9) (45.4) (53.0) (60.6) Air Consumption T est Conditions: Pump tested in water with inlet submerged. FLUID FLOW––gpm (lpm) A B C T o find Pump Air Consumption (scfm or m  /min) at a specific fluid flow (gpm/lpm) and air pre ...

  • Graco Inc. D 5 E - page 36

    36 308981 Graco W arranties Graco Standard Husky Pump W arranty Graco w arrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco w ill, for a pe ...

Manufacturer Graco Inc. Category Paint Sprayer

Documents that we receive from a manufacturer of a Graco Inc. D 5 E can be divided into several groups. They are, among others:
- Graco Inc. technical drawings
- D 5 E manuals
- Graco Inc. product data sheets
- information booklets
- or energy labels Graco Inc. D 5 E
All of them are important, but the most important information from the point of view of use of the device are in the user manual Graco Inc. D 5 E.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Graco Inc. D 5 E, service manual, brief instructions and user manuals Graco Inc. D 5 E. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Graco Inc. D 5 E.

A complete manual for the device Graco Inc. D 5 E, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Graco Inc. D 5 E by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Graco Inc. D 5 E.

A complete Graco Inc. manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Graco Inc. D 5 E - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Graco Inc. D 5 E, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Graco Inc. D 5 E, that we can find in the current document
3. Tips how to use the basic functions of the device Graco Inc. D 5 E - which should help us in our first steps of using Graco Inc. D 5 E
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Graco Inc. D 5 E
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Graco Inc. D 5 E in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Graco Inc. D 5 E?

Use the form below

If you did not solve your problem by using a manual Graco Inc. D 5 E, ask a question using the form below. If a user had a similar problem with Graco Inc. D 5 E it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)