  • Cleveland KDL-SH - page 1

    Operators Manual Installation, Operation & Service Floor Model Direct Steam Kettles MODELS : KDL, KDL-T , KDL-SH, KDL-TSH, KDP , KDP-T SE95007 Rev . 6 1333 East 179th St., Cle v eland, Ohio , U .S .A. 44110 Phone: (216) 481-4900 F ax: (216) 481-3782 Visit our web site at www .clev elandrange .com Clev elan d ™ Enodis ...

  • Cleveland KDL-SH - page 2

    Shut off pow er at main fuse disconnect prior to ser vicing. Ensure kettle is at room temperature and pressure gauge is showing z ero or less prior to removing any fittings . Inspect unit daily f or proper operation. 0 Do not fill kettle abo v e recommended le v el marked on outside of k ettle. Surf aces ma y be e xtremely hot! Use protectiv e equi ...

  • Cleveland KDL-SH - page 3

    GENERAL Installation of the unit must be accomplished by qualified installation personnel working to all applicable local and national codes. Improper installation of pr oduct could cause injury or damage. This unit is built to comply with applicable standards for manufacturers. Included among those appr oval agencies are: UL, NSF , ASME/Ntl.Bd., C ...

  • Cleveland KDL-SH - page 4

    STEAM All steam plumbing to and from the kettle and steam boiler should be thoroughly cleaned and inspected for dirt and debris before final connection to the kettle are made. Check the rating plate for the maximum steam pressur e that your kettle is rated for . If the steam supply pressur e exceeds the rated pressur e, a pressur e reducing valve i ...

  • Cleveland KDL-SH - page 5

    STEAM REQUIREMENTS FOR KETTLES Kettle Cap. Kettle 25 psi Steam 265°F 40 psi Steam 287°F 80 psi Steam 302°F U .S. Gal. Dia. Lbs./Hr . Hp./Hr . Lbs./Hr . Hp./Hr . Lbs./Hr . Hp./Hr . 40 26" 100 3 120 4 150 4.5 60 29.5" 150 4.5 190 5.5 230 7.0 80 33" 210 6.0 260 7.5 300 9.0 100 36" 260 7.5 320 9.5 390 11.0 125 40" 320 9.5 40 ...

  • Cleveland KDL-SH - page 6

    OPERA TING INSTRUCTIONS CLEVELAND STEAM COOKING EQUIPMENT IS INTENDED FOR COMMERCIAL USE ONL Y BY PR OFESSIONALL Y TRAINED PERSONNEL. General Parts Drawing ITEM # DESCRIPTION 1. Steam Inlet V alve Opens and closes the steam supply to the kettle. 2. Hand Wheel Used for tilting the kettle up or down. Some units have an optional Power Tilt Control Swi ...

  • Cleveland KDL-SH - page 7

    OPERA TION 1. Ensure that ther e is an adequate steam supply to the kettle. 2. For optimum perfor mance on free-standing floor model tilting kettles, open drain cock to drain condensate from the kettle’ s jacket, then close drain cock before applying steam to a cold kettle. 3. If the kettle is equipped with a tangent draw-off valve, ensure that i ...

  • Cleveland KDL-SH - page 8

    CARE AND CLEANING Cooking equipment must be cleaned regularly to maintain its fast, efficient cooking performance and to ensure its continued safe, r eliable operation. The best time to clean is shortly after each use (allow unit to cool to a safe temperature). W ARNINGS ➩ Do not use detergents or cleansers that are chloride based or contain quat ...

  • Cleveland KDL-SH - page 9

    ST AINLESS STEEL EQUIPMENT CARE AND CLEANING (Suppied courtesy of Nafem. For more information visit their web site at www .nafem.org) Contrary to popular belief, stainless steels ARE susceptible to rusting. Corrosion on metals is everywhere. It is r ecognized quickly on iron and steel as unsightly yellow/orange rust. Such metals are called “activ ...

  • Cleveland KDL-SH - page 10

    F AUCET ASSEMBL Y ITEM P ART DESCRIPTION QTY . NO . NO . 3/4" Spouts 1. KE50825-2 KDL-60/80/100-T , KDP-60/80-T . . . . . . . . .1 KE50825-3 KDL-25/40-T , KDP-25/30/40-T . . . . . . . . . .1 KE50825-7 KDL-40/60/80-TSH, . . . . . . . . . . . . . . . . . .1 KE50825-5 ALL ST A TIONAR Y KETTLES . . . . . . . . . . .1 2. F A95022 Retaining Ring . . ...

  • Cleveland KDL-SH - page 11

    STEAM CONTROL ASSEMBLIES ITEM NO . P ART NO . DESCRIPTION QTY . 1. KE51892 Retaining ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. KE51888 W asher . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 3. F A11501 V alve knob s ...

  • Cleveland KDL-SH - page 12

    CONTROL CONSOLE COMPONENTS - HAND TIL T ITEM NO . P ART NO . DESCRIPTION QTY . 1. F A11134 Screw , #1-24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 2. F A11501 Screw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 3. SE ...

  • Cleveland KDL-SH - page 13

    CONTROL CONSOLE COMPONENTS - HAND TIL T ...

  • Cleveland KDL-SH - page 14

    ITEM NO . P ART NO . DESCRIPTION QTY . 1. KE55057-10 Gear Box Lid (25-60 gallon) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE55057-3 Gear Box Lid (80 gallon & up) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. F A11134 Screw , 10-24 x 3/8" SS . . . . . . . . . . . . . ...

  • Cleveland KDL-SH - page 15

    CONTROL CONSOLE COMPONENTS - POWER TIL T ITEM NO . P ART NO . DESCRIPTION QTY . 8. SE00028 Steam Inlet Knob Assembly (Item no. 7 included) . . . . . . . . . . . . . . . . . . . . . . .1 9. KE50441 Tilt Shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 10. F A95008 Locknut, 3/4-16 ...

  • Cleveland KDL-SH - page 16

    HINGE ASSEMBL Y 1 5 3 2 13 12 6 4 7 11 8 10 9 9 ITEM NO . P ART NO . DESCRIPTION QTY . Hinge Assembly 1. - 11 KE50597-1 25 - 40 Gallon, 20 Gallon Full Jacketed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE50597-2 60 - 80 Gallon, 30 - 40 Gallon Full Jacketed . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE50597-3 100 - 1 ...

  • Cleveland KDL-SH - page 17

    1 2 3 4 5 6 7 T ANGENT DRA W-OFF V AL VE ITEM NO. P ART NO. DESCRIPTION QTY . 1. - 7. KE50973 2” DRAW-OFF ASSEMBL Y . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE50972-B 3” DRA W-OFF ASSEMBL Y . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 1. F A95049 WING NUT , TD-2 . . ...

  • Cleveland KDL-SH - page 18

    PRESSURE RELIEF V AL VE TESTING PROCEDURE The pressur e relief valve must be checked at least twice a year as part of the normal maintenance per formed. 1. With the kettle empty , fully open the steam valve and allow the kettle to preheat. 2. Stand to the side of the pressur e relief valve discharge tube and pull valve open for a maximum of one sec ...

  • Cleveland KDL-SH - page 19

    TROUBLESHOOTING GUIDE This section contains information intended for use by Authorized Service Personnel only . PROBLEM A / Kettle heats too slowly or does not come to a boil. Probable Cause Remedy 1. Inadequate steam flow . Check for correct steam using chart below . If kettle is connected to a steamer and powered by a generator the units should b ...

Manufacturer Cleveland Category Hot Beverage Maker

Documents that we receive from a manufacturer of a Cleveland KDL-SH can be divided into several groups. They are, among others:
- Cleveland technical drawings
- KDL-SH manuals
- Cleveland product data sheets
- information booklets
- or energy labels Cleveland KDL-SH
All of them are important, but the most important information from the point of view of use of the device are in the user manual Cleveland KDL-SH.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Cleveland KDL-SH, service manual, brief instructions and user manuals Cleveland KDL-SH. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Cleveland KDL-SH.

A complete manual for the device Cleveland KDL-SH, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Cleveland KDL-SH by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Cleveland KDL-SH.

A complete Cleveland manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Cleveland KDL-SH - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Cleveland KDL-SH, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Cleveland KDL-SH, that we can find in the current document
3. Tips how to use the basic functions of the device Cleveland KDL-SH - which should help us in our first steps of using Cleveland KDL-SH
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Cleveland KDL-SH
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Cleveland KDL-SH in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Cleveland KDL-SH?

Use the form below

If you did not solve your problem by using a manual Cleveland KDL-SH, ask a question using the form below. If a user had a similar problem with Cleveland KDL-SH it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)