Manual Universal Security Instruments MP117

10 pages 0.08 mb
Download

Go to site of 10

Summary
  • Universal Security Instruments MP117 - page 1

    SMOKE & FIRE ALARM WITH SILENCE FEA TURE AND ALARM ORIGINA TION FEA TURE T able of Contents: Page # Smoke Alarm Limitations and Functions ................................. 2 Recommended Location of Alarms ......................................... 3 Avoid These Locat ions ........................................................... 4 Early W arni ...

  • Universal Security Instruments MP117 - page 2

    SMOKE ALARM LIMIT A TIONS AND FUNCTIONS  There are three basic smoke alarm types: IoPhic , Ionization and Photoelectric . IoPhic is an ionization alarm containing a patent-pending Universal Smoke Sensing T echnology . IoPhic  alarms are very effective at detecting fast flaming fires and also respond very quickly to slow smoldering fires - up ...

  • Universal Security Instruments MP117 - page 3

    RECOMMENDED LOCA TION OF ALARMS • Locate the first smoke alarm in the immediate area of the bedrooms. T ry to protect the escape route as the bedrooms are usually farthest from an exit. If more than one sleeping area exists, locate additional smoke alarms in each sleeping area. If a hall is more than 40 feet (12 meters) long, install a smoke alar ...

  • Universal Security Instruments MP117 - page 4

    THIS SMOKE ALARM WILL NOT WORK WITHOUT 120 V AC POWER AND A GOOD BA TTERY PROPERL Y INST ALLED. THE SMOKE ALARM SHOULD BE TESTED WHEN INST ALLED AND THEN TESTED WEEKL Y AFTER THA T . INST ALLA TION INSTRUCTIONS: CAUTION!! READ CAREFULL Y . Installation of this alarm must conform to the electrical codes in your area; Article 760 of the National Elec ...

  • Universal Security Instruments MP117 - page 5

    DO NOT T AMPER WITH WIRES WHEN POWER IS ON! For alarms that are used as single smoke alarms, do not connect the yellow wire to anything. Insulate this wire (tape it) in place to make certain the yellow wire cannot contact any metal parts. IInterconnected alarms can provide earlier warning of fire than stand-alone alarms, especially if a fire starts ...

  • Universal Security Instruments MP117 - page 6

    OPERA TION, TESTING & MAINTENANCE OPERA TION: The smoke alarm is operating once the AC power is connected and turned on (the battery must also be installed). When products of combustion are sensed, the alarm sounds a loud alarm which continues until the air is cleared. This alarm incorporates the NFP A recognized horn signal for evacuation. Dur ...

  • Universal Security Instruments MP117 - page 7

    Page 7 If you choose to use an aerosol smoke product to test the smoke alarm, be certain to use one that has been Listed to Underwriters Laboratories, Inc. Safety S tandards and use it only as directed. Use of non-UL Listed products or improper use of UL Listed products may af fect the smoke alarm's sensitivity. NUISANCE ALARM SILENCE FEATURE: ...

  • Universal Security Instruments MP117 - page 8

    DEVELOP AND PRACTICE A PLAN OF ESCAPE BASICS OF ESCAPE PLAN o Make a floor plan indicating all doors and windows and at least two escape routes from each room. Second story windows may need a rope or chain ladder . o Have a family meeting and discuss your escape plan, showing everyone what to do in case of fire. o Determine a place outside your hom ...

  • Universal Security Instruments MP117 - page 9

    -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver . -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. CAUTION (AS REQUIRED BY THE CALIFORNIA ST A TE FIRE MARSHAL) ...

  • Universal Security Instruments MP117 - page 10

    * 288-3448-00 ©2010, UNIVERSAL SECURITY INSTRUMENTS, INC. Printed in China Visit Us on the W eb! w w w .UsiElectric.com 1 1407 Cronhill Drive, Suite A Owings Mills, Maryland 21 1 17 USA TEN YEAR LIMITED W ARRANTY MODELS MP1 17, MP1 18 MODELS MP1 17L, MP1 18L USI ELECTRIC, INC./UNIVERSAL SECURITY INSTRUMENTS, INC. ("USI") warrants your US ...

Manufacturer Universal Security Instruments Category Smoke Alarm

Documents that we receive from a manufacturer of a Universal Security Instruments MP117 can be divided into several groups. They are, among others:
- Universal Security Instruments technical drawings
- MP117 manuals
- Universal Security Instruments product data sheets
- information booklets
- or energy labels Universal Security Instruments MP117
All of them are important, but the most important information from the point of view of use of the device are in the user manual Universal Security Instruments MP117.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Universal Security Instruments MP117, service manual, brief instructions and user manuals Universal Security Instruments MP117. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Universal Security Instruments MP117.

A complete manual for the device Universal Security Instruments MP117, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Universal Security Instruments MP117 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Universal Security Instruments MP117.

A complete Universal Security Instruments manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Universal Security Instruments MP117 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Universal Security Instruments MP117, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Universal Security Instruments MP117, that we can find in the current document
3. Tips how to use the basic functions of the device Universal Security Instruments MP117 - which should help us in our first steps of using Universal Security Instruments MP117
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Universal Security Instruments MP117
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Universal Security Instruments MP117 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Universal Security Instruments MP117?

Use the form below

If you did not solve your problem by using a manual Universal Security Instruments MP117, ask a question using the form below. If a user had a similar problem with Universal Security Instruments MP117 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)