Manual Hunter Fan 42710-01

58 pages 3.29 mb
Download

Go to site of 58

Summary
  • Hunter Fan 42710-01 - page 1

    Form# 42710-01 20091204 ©2009 Hunter Fan Co. Set & $a v e Set & $a v e Set & $a v e Installation and Operation Manual Model 44360 Programmable Thermostat English ...

  • Hunter Fan 42710-01 - page 2

    2 ...

  • Hunter Fan 42710-01 - page 3

    3 T able of Contents Important Information .............................................................................. 5 T ools ........................................................................................................ 6 Uninstalling the Existing Unit ................................................................... 7 Installing ...

  • Hunter Fan 42710-01 - page 4

    4 Congratulations! Thank you for choosing a Hunter programmable thermostat. Y our new Hunter thermostat will provide years of reliable service and year-round energy savings. Please read this manual before beginning installation and save this booklet for complete operation instructions. The Hunter T echnical Support Group is available from 7 am to 7 ...

  • Hunter Fan 42710-01 - page 5

    5 This thermostat is designed to work on the following heating and cooling systems: Gas – Standing Pilot Gas – Electronic Ignition Gas – Fired Boilers Gas – Millivolt Systems Oil – Fired Boilers Oil – Fired Furnace Electric Furnace Electric Air Conditioning Single-Stage Heat Pumps This thermostat is not designed for multi-stage heat pum ...

  • Hunter Fan 42710-01 - page 6

    6 This thermostat includes two #8 slotted screws and two wall anchors for mounting. T o install your new thermostat, you will need the following supplies: Flat-head screwdriver ............................................................................................. Small Phillips-head screwdriver ............................................... ...

  • Hunter Fan 42710-01 - page 7

    7 NOTICE! Do not disconnect the wires from the existing thermostat before reading these instructions. The wires must be labeled prior to removal to ensure proper reconnection. Y RC G W w Y RC G W ...

  • Hunter Fan 42710-01 - page 8

    8 Y RC G W Y RC G W ...

  • Hunter Fan 42710-01 - page 9

    9 1. T urn the system power OFF from the existing thermostat. T urn the power to the HV AC system OFF at the main power panel or at the furnace. (Failure to turn off the power to the existing thermostat before removal could damage your system.) 2. Remove the existing thermostat cover to access the wires from the wall. (Some thermostats may have mul ...

  • Hunter Fan 42710-01 - page 10

    10 G RC RH Y W if your existing thermostat is marked... label the wire with this sticker: G / F G G W / H / B W/B W/B Y / C* / M / O Y/0 Y/0 RC / VC RC RC RH / R / VR / 4 RH RH 24 V olt 24 V olt cool air conditioning compressor heating fan Y1 Y1 Y1 heat pump compressor WIRE LABELS ...

  • Hunter Fan 42710-01 - page 11

    1 1 4. Using the provided stickers, label each wire according to the Wire Labels chart. (If the terminals are not labeled, contact a qualied HV AC technician.) Note : Wire colors do not always comply with standards, so wire color should be ignored. Refer to the existing terminal designation for proper identication. *If wires marked Y & C ...

  • Hunter Fan 42710-01 - page 12

    12 W/B RC G Y/0 Y1 ...

  • Hunter Fan 42710-01 - page 13

    13 INST ALLING THE THERMOST A T INST ALLING THE W ALL PLA TE 1. Remove the wall plate from the new thermostat by pressing the release tab on the bottom of the thermostat. 2. Position the new wall plate on the wall and pull the labeled wires through the opening. 3. If the existing holes do not match those on the Hunter wall plate, or if there are no ...

  • Hunter Fan 42710-01 - page 14

    14 W RC Y G ...

  • Hunter Fan 42710-01 - page 15

    15 4. Remove the wall plate and drill two 3/16” holes where marked. 5. T ap the plastic anchors into the holes until they are ush with the wall. (Do not use plastic anchors if you encounter a stud in the wall.) 6. Reposition the wall plate on the wall, pulling the wires through the opening. Insert the mounting screws through the wall plate and ...

  • Hunter Fan 42710-01 - page 16

    16 G RC RH Y/0 W/B RC G Y1 Y/0 W/B Y1 T erminal Shield ...

  • Hunter Fan 42710-01 - page 17

    17 INST ALLING THE THERMOST A T , CONT . CONNECTING THE WIRES 1. Loosen, but do not remove, the terminal screws. Note: A jumper wire has been provided, connecting the RC and RH terminals for systems that do not provide both an RH and RC wire. If you have both an RH and RC wire, remove this jumper . If you do not have both an RH and RC wire, leave t ...

  • Hunter Fan 42710-01 - page 18

    18 DISABLE ENABLE RECOVERY HG HE W/B Y/O RH RC G SYSTEM TYPE STD HP Y1 FAN OPTION AM HEAT 4 T Thermostat Cov er System Switch F an Switch ...

  • Hunter Fan 42710-01 - page 19

    19 A TT ACHING THE THERMOST A T Lift the thermostat cover and set the SYSTEM switch to OFF and the F AN switch to AUTO . 1. Fan option - Locate the HE/HG switch on the back of the thermostat. Set the switch to HG (default) for gas furnace and oil burners. Set the switch to HE for electric furnaces. (The switch has no effect when the system is set t ...

  • Hunter Fan 42710-01 - page 20

    20 1 2 front cov er T ab ...

  • Hunter Fan 42710-01 - page 21

    21 4. Place the top of the thermostat over the two tabs on the wall plate. Press the thermostat onto the wall plate and press to snap the bottom tab into place. Note: Do not force the thermostat onto the wall plate, as the terminal pins may be damaged. If the thermostat does not snap into place properly , the unit may not work. 5. Lift the front co ...

  • Hunter Fan 42710-01 - page 22

    22 reset ...

  • Hunter Fan 42710-01 - page 23

    23 The default setting of the thermostat is Fahrenheit (F o ). (NOTICE: CHANGING THIS SETTING WILL RESET THE THERMOST A T T O F ACTOR Y DEF AUL T PROGRAMS.) T o change to Celsius (C o ): 1. Press and hold the U p button. 2. Use a paperclip to press the R ESET button. 3. Continue to press the U p button, but release the Reset button when the LCD tur ...

  • Hunter Fan 42710-01 - page 24

    24 day/time AM PM program ...

  • Hunter Fan 42710-01 - page 25

    25 The default for this thermostat setting is in a 12 hour format. Y ou can change the format to 24 hour format by pressing D A Y /T iME and then p ROGRAM . The AM/PM indicator will be off when the thermostat is in 24 hour mode. Setting day and time: 1. Press D A Y /T iME . (AM/PM and current hour will ash) Press U p or D OwN to adjust the setti ...

  • Hunter Fan 42710-01 - page 26

    26 AM HEAT 4 T ...

  • Hunter Fan 42710-01 - page 27

    27 This thermostat gives you the ability to program up to 4 custom temperature settings per day or utilize pre-programmed settings. For manual operation / override instructions, see pages 28-35. T o utilize the pre-programmed settings, see pages 36-37. T o create custom programs, see pages 38-41. METHODS OF OPERA TION ...

  • Hunter Fan 42710-01 - page 28

    28 AM HEA T 2 TH ...

  • Hunter Fan 42710-01 - page 29

    29 1. MANUAL OPERA TION / OVERRIDE Many people prefer to operate their thermostats manually , adjusting settings as needed. Y ou can either temporarily override the settings for the current program, or permanently override all settings and adjust temperatures manually . If you want to only override the current program: 1. Press and hold U p or D Ow ...

  • Hunter Fan 42710-01 - page 30

    30 hold /return system off heat cool HOLD ...

  • Hunter Fan 42710-01 - page 31

    31 2. PERMANENT OVERRIDE If you want to permanently override all settings and adjust the thermostat manually: 1. Press H OlD /R ETURN until the Hold icon appears. 2. Press and hold U p or D OwN for one second to enter Manual Override mode. (Release the button when the display ashes.) 3. Press the U p or D OwN buttons to adjust the temperature se ...

  • Hunter Fan 42710-01 - page 32

    32 h o m e t o d a y HOME T ODA Y ...

  • Hunter Fan 42710-01 - page 33

    33 3. HOME T ODA Y OVERRIDE Overrides the programmed settings during a time you would not normally be home. Pressing Home T oday during the rst or second programs of the day will override the programs until the fourth program begins. The thermostat will then go back into Normal mode. Pressing Home T oday during the third program of the day will ...

  • Hunter Fan 42710-01 - page 34

    34 Set T emp ...

  • Hunter Fan 42710-01 - page 35

    35 METHODS OF OPERA TION 4. V ACA TION OVERRIDE Overrides the programmed settings for a set amount of days. The rst number in V acation Override mode indicates the number of days you wish to hold the temperature for , and the temperature beside it indicates the temperate you want to be held during those days.The rst day you set the V acation ...

  • Hunter Fan 42710-01 - page 36

    36 10 pm 8 am 6 am Program 1 Heat : 68 o F (20 o C) Cool : 78 o F (26 o C) Program 2 Heat : 60 o F (16 o C) Cool : 85 o F (29 o C) Program 3 Heat : 68 o F (20 o C) Cool : 78 o F (26 o C) Program 4 Heat : 60 o F (16 o C) Cool : 82 o F (28 o C) 4 pm DEF AUL T PROGRAMS CHAR T ...

  • Hunter Fan 42710-01 - page 37

    37 5. DEF AUL T PROGRAMS By using the pre-programmed settings, this thermostat can save you money by optimizing energy usage in heating and cooling. Refer to the Default Programs Chart for detailed information about the pre-programmed settings. ...

  • Hunter Fan 42710-01 - page 38

    38 AM PM program hold /return system off heat cool ...

  • Hunter Fan 42710-01 - page 39

    39 6. CREA TING CUSTOM PROGRAMS • Program times can be set in 10 minute increments. • Program temperature can be set in increments of 1 o F (1 o C). • After 15 seconds of inactivity during programming, the thermostat will return to Normal Display mode. • When setting each program time, note the AM/PM indicator . • Press H OlD /R ETURN at ...

  • Hunter Fan 42710-01 - page 40

    40 AM PM HEA T COOL 2 1 3 4 M T W TH F SA SU program hold /return system off heat cool ...

  • Hunter Fan 42710-01 - page 41

    41 3. Press U p or D OwN to change the hour . Press p ROGRAM to save the hour and adjust the minute setting. 4. Press U p or D OwN to change the minute. Press p ROGRAM to save the minute setting and adjust the temperature. 5. Press U p or D OwN to change the temperature. Press p ROGRAM again to move to the next program number . (There are 4 program ...

  • Hunter Fan 42710-01 - page 42

    42 filter FIL TER ...

  • Hunter Fan 42710-01 - page 43

    43 ICONS AND FEA TURES 1. INDIGLO ® night-light - will backlight the display for easy viewing in the dark. Press any button to illuminate the light. (If no button is pressed after 5 seconds, the backlight will turn off.) Note: If the thermostat shows a Low Battery W arning, the backlight will not operate. Follow the instructions on pages 42-43 to ...

  • Hunter Fan 42710-01 - page 44

    44 e n e r g y Usage T oday Min Hr ...

  • Hunter Fan 42710-01 - page 45

    45 ICONS AND FEA TURES, CONT . 3. Energy – calculates energy usage. Press to display the total opera tion ti me for heat an d air c onditio ning fo r today , yest erday , last week, or T otal. Monitoring energy usage allows you to optimize energy savings. Press E NERGY to cycle through T oday , Y esterday , This W eek, and T otal (up to 999 hours ...

  • Hunter Fan 42710-01 - page 46

    46 HEA T COOL system off heat cool reset ...

  • Hunter Fan 42710-01 - page 47

    47 5. Span setting mode – allows you to adjust the system ON/OFF cycle rate. The default setting is 2 (the system cycles ON or OFF when the temperature is within 1 o F (0.5 o C) above and below the set temperature.) The span setting can be adjusted if your system is cycling too fast or too slowly . Press and hold both the U p and D OwN buttons un ...

  • Hunter Fan 42710-01 - page 48

    48 ST A GE 1 PM COOL 4 M ST A GE 2 ...

  • Hunter Fan 42710-01 - page 49

    49 6. Low battery warning – indicates two stages of battery power shortage. When the batteries are detected as weak, the icon will ash until new AA alkaline batteries are installed (Stage 1). If the batteries become too weak for normal operation, the thermostat enters the second battery power shortage mode (Stage 2). When insufcient battery ...

  • Hunter Fan 42710-01 - page 50

    50 hold /return ...

  • Hunter Fan 42710-01 - page 51

    51 7. Auto recovery – allows heating and cooling systems to gradually recover from an energy-saving setpoint temperature to a comfort setpoint temperature. Auto recovery calculates the time needed to adjust the temperature to the next program setting. When the thermostat is in Auto Recovery mode, the display will ash alternating messages of RE ...

  • Hunter Fan 42710-01 - page 52

    52 ...

  • Hunter Fan 42710-01 - page 53

    53 8. Error mode – indicates an unexpected battery problem. The screen will ash an ERR message and shut your system off until the batteries are replaced with new AA alkaline batteries. Y ou must Reset and reprogram the thermostat after replacing the batteries if the thermostat has entered Error mode. 9. Auto cut off – automatically turns the ...

  • Hunter Fan 42710-01 - page 54

    54 1. T emperature Range 2. Compressor Protection After the system stops running in cooling mode, there will be a 3.5 minute delay before it can be restarted to prevent compressor damage due to rapid cycling. 3. Resetting the unit T o restore the thermostat to the original factory settings, press the reset button with a paperclip. (This will erase ...

  • Hunter Fan 42710-01 - page 55

    55 1. My display will not come on. 1 a. Check batteries and battery connections. 1 b. Reset the thermostat. ............................................................................................. 2. The auto fan feature will not operate properly . 2 a. Remove the thermostat from the wall plate and set the HG/HE switch to the correct position. ...

  • Hunter Fan 42710-01 - page 56

    56 5. My heating or cooling will not turn on or off. 5 a. Check the Heat/Cool function switch to ensure it is set to the desired position. 5 b. W ait. There may be as much as a 4-minute delay before the system turns on or off to protect the compressor . 5 c. Check the circuit breakers and switches to ensure there is power to the system. 5 d. Replac ...

  • Hunter Fan 42710-01 - page 57

    57 7. My system continues to operate when the thermostat is in the off position. 7 a. Replace unit. 7 b. Check your system for proper wiring. ............................................................................................. 8. The LCD screen permanently reads HI, LO, or ERR. 8 a. Replace unit. ........................................... ...

  • Hunter Fan 42710-01 - page 58

    58 Is there help on the web? Y es. Visit http://www .hunterfan.com for more information. ............................................................................................. Can’t I just call someone? Sure. The Hunter T echnical Support Group is available from 7 am to 7 pm CST M-F and 8 am to 5 pm Saturday . They may be reached toll-free ...

Manufacturer Hunter Fan Category Thermostat

Documents that we receive from a manufacturer of a Hunter Fan 42710-01 can be divided into several groups. They are, among others:
- Hunter Fan technical drawings
- 42710-01 manuals
- Hunter Fan product data sheets
- information booklets
- or energy labels Hunter Fan 42710-01
All of them are important, but the most important information from the point of view of use of the device are in the user manual Hunter Fan 42710-01.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Hunter Fan 42710-01, service manual, brief instructions and user manuals Hunter Fan 42710-01. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Hunter Fan 42710-01.

Similar manuals

A complete manual for the device Hunter Fan 42710-01, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Hunter Fan 42710-01 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Hunter Fan 42710-01.

A complete Hunter Fan manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Hunter Fan 42710-01 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Hunter Fan 42710-01, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Hunter Fan 42710-01, that we can find in the current document
3. Tips how to use the basic functions of the device Hunter Fan 42710-01 - which should help us in our first steps of using Hunter Fan 42710-01
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Hunter Fan 42710-01
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Hunter Fan 42710-01 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Hunter Fan 42710-01?

Use the form below

If you did not solve your problem by using a manual Hunter Fan 42710-01, ask a question using the form below. If a user had a similar problem with Hunter Fan 42710-01 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)