    EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 1 GENERAL ST A TEMENT IMPORT ANT : The information cont ained in this manual is critical to the correct operation and main- tenance of the EMI cassette and should be read by all persons responsible for the installation, start up and maintenance of the unit. SAFETY : The equipment has been designe ...

  • EMI WLCA - page 2

    EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 2 displayed on the fascia mounted receiver . The microproces- sor also limits the number of compressor starts per hour to reduce wear on the compressor . The infrared transmitter is used to switch the unit on/off, change temperature settings, fan speed, operating mode and to toggle the motorized ...

  • EMI WLCA - page 3

    EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 3 1. Position the thermostat approximately 5 ft. above floor level. 2. Do not position thermostat where it can be directly affected by the unit’s discharge air stream. 3. Avoid external walls and draft s from windows and doors. 4. Avoid positioning near shelves and curtains as these restrict ai ...

  • EMI WLCA - page 4

    EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 4 SECTION THROUGH F ASCIA FASCIA BLANKING PIECE 3. Condensate pipework should slope downwards in the direction of water flow with a minimum gradient of (1” per 10’). There must not be any uphill gradients other than in the first 18” of pipework from the Cassette. 4. When multiple Cassettes ...

  • EMI WLCA - page 5

    EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 5 E LE CT R ICAL S P E CIF ICATIO N S SM A L L M E DIU M L A R GE P OW E R SU P P LY 230V / 1P H /60H Z 230V /1P H /60H Z 230V / 1P H /60H Z F U LL LO A D A M P S A 0.4 0.6 0.9 MI N. CIRCUIT A MP A CITY ( MCA ) A 0 . 5 0 . 7 5 1 . 1 3 REC. FU S E A 1 51 51 5 SM A L L M E DIU M L A R GE P OW E R S ...

  • EMI WLCA - page 6

    EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 6 STA RT U P SH E E T E XA M PLE E N VIR OM ASTE R IN TE R N A TION AL LL C 5780 SU C C ESS D RIVE R O M E , N Y 1 34 4 0 T EL: 1 -800-22 8-9364 F A X: 1 -800-23 2-9364 H T T P :/ / WWW.E N VIR OM A S T E R .C O M CO M M ENT: IN ITIA L TE ST PR ESSU R E FIN A L TES T PRESSURE T E S T DU RA TI O N ...

  • EMI WLCA - page 7

    EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 7 CAH/ W TECHNICAL DAT A R E F R I G E R A T I O N 09- 12 15 18- 24 30-3 6 42- 48 NUM BE R O F CIRCUI T S 1 1 1 1 1 R E FR IGE R A N T T Y PE R 2 2 R 2 2 R 2 2 R 2 2 R 2 2 CABI NE T DIM ENS I ONS 0 9 - 1 2 1 5 1 8 - 2 4 3 0 - 3 6 4 2 - 4 8 H EI GHT 10 -3 /4" 9 -1/2" 9 -1/2" 11 -1 / ...

  • EMI WLCA - page 8

    EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 8 SMALL CABINET • CAH 9,000 - 12,000 • CAHW 9,000 ONL Y • CAF 8,000 - 12,000 • CAF4 8,000 ONL Y EMI CASSETTE DIMENSIONS ...

  • EMI WLCA - page 9

    EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 9 MEDIUM CABINET • CAH 15,000 - 24,000 • CAHW 12,000 - 24,000 • CAF 18,000 - 20,000 • CAF4 12,000 - 20,000 CAS S ETT E DIM ENS IO NS ( I NCHE S ) S I Z E ABCD E F G H J K LM N M EDIUM 11 37 37 1¾ 32¾ 32¾ 2¾ ½ Ø 5 3¼ 9½ ¾ 33 ¼ LARG E 13 49¼ 37 1¾ 32¾ 45 2¾ ½ Ø 6 13¼ 9½ ¾ ...

  • EMI WLCA - page 10

    EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 1 0 The red indicator will be lit when the in-built time clock func- tion is activated. T o disable the time clock, all start/stop times must be set to 12am via the transmitter (see program- ming instructions in this installation manual). The red indi- cator is also used to diagnose operational a ...

  • EMI WLCA - page 11

    EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 1 1 DISPLA Y INDICA T ORS TRANSMIT INDICA TOR Flashes when system settings are transmitted. MODE INDICA TOR Highlights Mode of Operation. F AN MODE INDICA TO R Highlights Fan Speed. CLOCK/TIMER DISPLA Y Shows current day , time, or weekly program Stop/Start times. SETPOINT DISPLA Y Indicated temp ...

  • EMI WLCA - page 12

    EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 1 2 SETTING UP THE BUIL T -IN TIME CLOCK HOW TO SET THE PRESENT TIME 1. Press CLK/Timer: “Clock Set” highlights. NOTE: Display will stop flashing after 15 seconds. 2. Select Hour with either (+) or (-). figure will flash. 3. Press (+) or (-) to change hour . 4. Press CLK/Timer to confirm and ...

  • EMI WLCA - page 13

    EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 1 3 IMPORT ANT : As of 12/01/04 EMI air handlers will be manu- factured with a low Volt transformer installed. At the same time, EMI outdoor condensers will be manufactures with- out a low Volt transformer . When connecting an EMI evapo- rator to a non-EMI condenser , check to ensure that there i ...

  • EMI WLCA - page 14

    EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 1 4 TRANSMITTER F AILURE (MICRO UNITS ONL Y). Try new batteries first, if receiver bleeps on transmitting signal, trans- mitter is OK. If no response press On/Off button on unit fascia. If the unit responds to the On/Off button transmitter is faulty . MICROPROCESSOR F AILURE (MICRO UNITS ONL Y). ...

  • EMI WLCA - page 15

    EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 1 5 HIGH CONDENSA TE LEVEL TRIP . Drain the condensate tray and investigate. See section “Condensate high Level/” erating pressures. Check filter condition. (See maintenance instructions for more information). SENSOR F AILURE (MICRO UNITS ONL Y). If any of the sensors are faulty the microproc ...

  • EMI WLCA - page 16

    EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 1 6 NO HEA TING (E lectric Heat) POSSIBLE CAUSES/REMEDIES INCORRECT MODE SETTING (MICRO UNITS ONL Y) – Check that the transmitter Mode is set to Heat or Auto Mode. SET POINT TOO LOW – Check the set point on the trans- mitter or wall mounted thermostat and adjust if necessary . OVERHEA T CUT O ...

  • EMI WLCA - page 17

    EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 1 7 MAINTENANCE EVERY 3 MONTHS: Check the air filter condition and clean if necessary (see below). EVERY 6 MONTHS: Same as 3 months plus clean conden- sate tray with biocide suitable for polystyrene and clean fas- cia. EVERY 12 MONTHS: Same as 6 months plus check all electrical connections for se ...

  • EMI WLCA - page 18

    EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 1 8 TERMINAL BLOCK INSTRUCTION FOR THE CONNECTION OF HIGH/LOW VOL T AGE WIRES When connecting line and/or low voltage wires to the CAH terminal block(s) a 3/32-screw driver (thermostat type) is required. 1. Insert the screwdriver into the square hole until you “hit bottom.” This will open the ...

  • EMI WLCA - page 19

    EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 1 9 1. Cassette Chassis 2. Evaporator Assembly 3. Electric Heater Element Assembly 4. Condensate Tray 5. Condensate Tray Supports (2) 6. Condensate Pump 7. High Level Switch 8. Condensate Pump Assembly 9. Fan/Motor Assembly 10. Coil/Return Air Sensors 1 1. Grille 12. Label 13. Air Deflector V ane ...

  • EMI WLCA - page 20

    EMI@ENVIROMASTER.COM ENVIROMASTER INTERNA TIONAL LLC 2 0 1 8 5 7 10 18 19 20 14 3 2 9 4 6 16 13 12 15 11 17 1. Cassette Chassis 2. Evaporator Coil 3. Condensate Tray 4. Condensate Tray Support 5. Condensate Pump 6. High Level Switch 7. Fan & Motor Assembly 8. Fan Inlet Ring 9. Grille 10. Infrared Receiver 1 1. V ane 12. V ane Motor Assembly 13. ...

Manufacturer EMI Category Air Conditioner

Documents that we receive from a manufacturer of a EMI WLCA can be divided into several groups. They are, among others:
- EMI technical drawings
- WLCA manuals
- EMI product data sheets
- information booklets
- or energy labels EMI WLCA
All of them are important, but the most important information from the point of view of use of the device are in the user manual EMI WLCA.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals EMI WLCA, service manual, brief instructions and user manuals EMI WLCA. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product EMI WLCA.

Similar manuals

A complete manual for the device EMI WLCA, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use EMI WLCA by users. Manuals are usually written by a technical writer, but in a language understandable to all users of EMI WLCA.

A complete EMI manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual EMI WLCA - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the EMI WLCA, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the EMI WLCA, that we can find in the current document
3. Tips how to use the basic functions of the device EMI WLCA - which should help us in our first steps of using EMI WLCA
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with EMI WLCA
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of EMI WLCA in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning EMI WLCA?

Use the form below

If you did not solve your problem by using a manual EMI WLCA, ask a question using the form below. If a user had a similar problem with EMI WLCA it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)