    Friendly NET ® FM2017 SNMP/W eb Managed Sw itch w ith Fiber Option User ’ s Manual ...

  • Asante Technologies FM2017 - page 2

    2 ...

  • Asante Technologies FM2017 - page 3

    3 Table Of Contents Chapter 1. Introduction 5 Features 5 Ethernet Switching T echnology 6 Management M ethods 6 Chapter 2. Hardware Installation 7 Package Contents 7 Front Panel 7 Rear Panel 8 Mounting Configurations 8 Powering on the Switch 8 Optional FX100 M odules 8 Chapter 3. Network Application 1 1 Small W orkgroup 1 1 Segment Bridge 1 1 VLAN ...

  • Asante Technologies FM2017 - page 4

    4 ...

  • Asante Technologies FM2017 - page 5

    5 Chapter 1. I ntroduction Thank you for purchasing an Asanté Friendly NET FM 2017 SNMP/W eb managed switch. This sw itch is designed to build high-performance switched netw o rks. It uses store-and-forward technology , providing low latency for high-speed netw orking, and is targeted at workgroup, department or backbone computing environments at ...

  • Asante Technologies FM2017 - page 6

    6 Ethernet Sw itching T echnology Ethernet switching technology has dramatically boosted the total bandwidth of a netw ork, eliminating congestion problems inherent with Carrier Sense M ultiple Access with Collision Detection (CSM A/CD) protocol, and has greatly reduced unnecessary transmissions. This revolutioniz ed networking in the follow ing wa ...

  • Asante Technologies FM2017 - page 7

    7 Chapter 2. Hardw are Installation This chapter describes the front and rear panels of the FM 2017, and explains how to install, mount and apply pow er to the switch. Package Contents The sw itch is shipped with the follow ing items: • Switch • AC power cord • Four (4) Rubber feet • Rack mount Kit • RS-232 cable • User’s Manual (this ...

  • Asante Technologies FM2017 - page 8

    8 Rear Panel The rear panel contains the Netw ork Management module and the 3-pronged power plug. T he switch uses AC in the range of 100-240V AC, 50-60Hz. The Netw ork Management module holds the Flash memory , and has two LEDs:  CPU Fail : The CPU Fail LED is lit when the sw itch’s self test and initialization are in progress, after powering ...

  • Asante Technologies FM2017 - page 9

    9 • FX100-M MC • FX100-SM C15 • FX100-SM C30 • FX100-SM C60 The FX 100 modules are designed to extend the allow able distance between the switch and other netw ork devices. The max imum distance that can be achieved with fiber cabling is 2 kilometers (multi-mode fiber) and up to 15, 30 or 60 kilometers (single-mode fiber). Front Panels The ...

  • Asante Technologies FM2017 - page 10

    10 ...

  • Asante Technologies FM2017 - page 11

    11 Chapter 3. Netw ork A pplication This section provides a few samples of network topology in w hich the switch can be used. In general, the switch is designed to be used as a segment switch. T hat is, with its large address table (8000 M AC address) and high performance, it is ideal for interconnecting networking segments. Y ou can use the switch ...

  • Asante Technologies FM2017 - page 12

    12 ...

  • Asante Technologies FM2017 - page 13

    13 Chapter 4. Netw ork Configurati on This chapter ex plains how to configure console management via a direct connection to the console port of the switch. Console management involves the administration of the sw itch via a direct connection to the RS-232 console port. This port is a female DB-9 connector . From the main menu of the console program ...

  • Asante Technologies FM2017 - page 14

    14 ---<<Current configuration>>---------------------------[1.0(beta 2)]---- - [MAC=00:00:94:D1:1C:22] [IP=192.168.0.1] [mask=255.255.255.0] [broadcast=255.255.255.255] [gateway=0.0.0.0] ------------------------------------------------------------------------ - 1. boot-method = [flash] 2. ip-address = [192.168.0.1] 3. subnet mask = [255. ...

  • Asante Technologies FM2017 - page 15

    15 E. Http server = [on] F. Telnet/Http username = [root] G. Telnet/Http password = [enabled] H. reboot I. logout J. ping K. help L. loaddefault M. securedip = [0.0.0.0],[0.0.0.0],[0.0.0.0] >>>> Press H to reboot the sw itch after making your change. Press Enter tw ice, and the new IP address w ill now be displayed. By the similar metho ...

  • Asante Technologies FM2017 - page 16

    16 ...

  • Asante Technologies FM2017 - page 17

    17 Chapter 5. Web-Based Management This section introduces the configuration and functions of the w eb-based management of switch. The FM 2017 provides an embedded HT ML w ebsite residing in the CPU module. It offers management features and allows users to manage the sw itch from anyw here on the network through a standard w eb browser . Sy stem Lo ...

  • Asante Technologies FM2017 - page 18

    18 Inside the System page, the follow ing information about the switch is listed: Network Setting • IP address : 192.168.0.1 • Subnet Mask : 255.255.255.0 • Broadcast : 255.255.255.255 • Default gateway : 0.0.0.0 The configuration above is only a reference setting. If you w ant to reset or change the numbers, you can click Agent Config to c ...

  • Asante Technologies FM2017 - page 19

    19 The data is automatically updated at regular interv als. Port Config Screen Y ou can use the Port Config page to disable/enable each port. By default, all the ports are Enabled . T o disable or enable a port: 1. Select the drop-down menu in the Status column. 2. Choose the status you w ant for each Ethernet and Fiber port. 3. Remember to click A ...

  • Asante Technologies FM2017 - page 20

    20 T o set these parameters for a port: 1. Select the drop-down menu in Speed/Duplex column. 2. Select one of the following choices: Auto/flow control enabled, Auto/flow control disabled, 100Base- Tx /Full Duplex , 100Base-Tx /Half Duplex , 10Base-T/Full Duplex or 10Base-T/Half Duplex . 3. Click Apply . VLA N Screen A VLAN (Virtual LAN ) is a group ...

  • Asante Technologies FM2017 - page 21

    21 A gent Con fig Screen In the Agent Config page, the switch’ s current configurations are displayed. Y ou can refer to the following Agent Config page for your ow n setting. Boot Method There are three modes of Boot M ethod: • FLASH : Boot y our system by flash settings. Flash memory resides in a chip and holds its content without pow er . So ...

  • Asante Technologies FM2017 - page 22

    22 Default A gent Configuration The follow ing are the default values of the Agent Config of the switch. Y ou can change the information listed by entering new information (for example, you can change the sw itch’s IP address by directly typing in a new IP address). Click A pply after entering the information. • Boot-Method : flash • IP addre ...

  • Asante Technologies FM2017 - page 23

    23 A ppendi x A . Troubl eshooting This section is intended to help you solv e the most common problems on the switch. If y ou still are having problems after reading through the information here, contact Asanté’s Technical Support for assistance. Your sw itch can easily be monitored through the LED indicators to assist in identifying problems. ...

  • Asante Technologies FM2017 - page 24

    24 ...

  • Asante Technologies FM2017 - page 25

    25 A ppendi x B. Inter net Explorer Setti ng If you are using Internet Ex plorer , you have to modify the brow ser setting to enable Java applets to use network ports. We used Internet Explorer 5.0 for the following demonstration. First, select ” Internet Optional ..” under “ T ools ” of the function bar , then follow the step-by-step instr ...

  • Asante Technologies FM2017 - page 26

    26 6. Go back to Internet Options, then click Custom Level . 7. Scroll down to find Jav a . 8. Select Custom under Java and click Java Custom Settings . 9. Select the Edit Permissions tab. 10. Select Enable under Unsigned Content , and then press OK . ...

  • Asante Technologies FM2017 - page 27

    27 A ppendix C. Specifications and Warranty Statement FriendlyNET FM 2017 Specificat ions Standards IEEE 802.3 10Base-T E thernet IEEE 802.3u 100Base-TX Fast E thernet ANSI/ IEE E 802.3 N-W ay auto-negotia tion Protoc ol CSMA/CD Maximum Forwarding Rate 14,880 pps per Et hernet port 148,800 pps per Fas t Ethernet port LED Indic ators Per Port: 10/10 ...

  • Asante Technologies FM2017 - page 28

    28 Friendly NET FM2017 SNMP/Web Managed Swi tch with Fi ber Option User ’ s Manual Asanté T echnologies, Inc. 821 Fox Lane San Jose, CA 95131 USA SALES 800-662-9686 Home/Office Solutions 800-303-9121 Enterprise Solutions 408-435-8388 TECHNICAL SUPPORT 801-566-8991: W orldwide 801-303-3787: FAX www.a s an t e. c om support@asante.com Copyright 20 ...

Manufacturer Asante Technologies Category Switch

Documents that we receive from a manufacturer of a Asante Technologies FM2017 can be divided into several groups. They are, among others:
- Asante Technologies technical drawings
- FM2017 manuals
- Asante Technologies product data sheets
- information booklets
- or energy labels Asante Technologies FM2017
All of them are important, but the most important information from the point of view of use of the device are in the user manual Asante Technologies FM2017.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Asante Technologies FM2017, service manual, brief instructions and user manuals Asante Technologies FM2017. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Asante Technologies FM2017.

A complete manual for the device Asante Technologies FM2017, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Asante Technologies FM2017 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Asante Technologies FM2017.

A complete Asante Technologies manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Asante Technologies FM2017 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Asante Technologies FM2017, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Asante Technologies FM2017, that we can find in the current document
3. Tips how to use the basic functions of the device Asante Technologies FM2017 - which should help us in our first steps of using Asante Technologies FM2017
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Asante Technologies FM2017
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Asante Technologies FM2017 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Asante Technologies FM2017?

Use the form below

If you did not solve your problem by using a manual Asante Technologies FM2017, ask a question using the form below. If a user had a similar problem with Asante Technologies FM2017 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)