    GS110W NA TURAL OR PR OP ANE GAS BOILERS INST ALLA TION & OPERA TION MANU AL GS110IOM-2 INST ALLER, THESE INSTR UCTIONS T O BE AFFIXED ADJA CENT T O THE HEA TER. CONSUMER, RET AIN THESE INSTR UCTIONS FOR FUTURE REFERENCE PURPOSES. W ARNING: If the information in this man ual is not follo wed exactl y , a fire or explosion ma y result causing pr ...

  • Smith Cast Iron Boilers GS110W - page 2

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 2 A VERTISSMENT . Assurez-v ous de bien suivre les instructions données dans cette notice pour réduire au minim um le risque d’incendie ou d’explosion ou pour éviter tout dommoge matériel, toute blessure ou la mort Ne pas entreposer ni utiliser d’essence ou ni d’a ...

  • Smith Cast Iron Boilers GS110W - page 3

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 3 Figure 1 - Clearances to Combustib le Construction The installation must conf or m to the requirements of the authority having jurisdiction or , in the absence of such requirements, to the National Fuel Gas Code , ANSI Z223.1-latest re vision. In Canada, the installation mu ...

  • Smith Cast Iron Boilers GS110W - page 4

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 4 All Combustion Air Fr om Inside The Building Older houses often hav e enough “leakage” to pro vide an adequate amount of combustion air pro vided that the demand f or combustion air is not too great, Figure 3. Homes that are relatively ne w or “tight” will most like ...

  • Smith Cast Iron Boilers GS110W - page 5

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 5 When calculating the free area necessar y to meet the make-up air requirements of the enclosure , consideration must be giv en to the bloc kage effects of louvers , grills and screens. Screens must ha ve a minimum mesh siz e of 1/4" (6.4mm). If the free area through a ...

  • Smith Cast Iron Boilers GS110W - page 6

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 6 Intake Air Option - General Guidelines This configuration provides comb ustion air directly to the boiler using a dedicated pipe. Combustion air can be dra wn in hor izontally through an outside w all or ver tically through the roof , see Figures 6, 7, 8, 9 & 10. W ARNI ...

  • Smith Cast Iron Boilers GS110W - page 7

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 7 Figure 6 - V er tical P ositive Pressure V enting with Outdoor Combustion Air (Cat. III) All joints in metal intake air systems m ust be secured using corrosion resistant f asteners and sealed using a suitable Silicone caulk. If PVC or CPVC is used, the joints must be clean ...

  • Smith Cast Iron Boilers GS110W - page 8

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 8 Figure 7 - Horizontal P ositive Pressure V enting with Outdoor Combustion Air Figure 8 - Horizontal P ositive Pressure V enting with Outdoor Combustion Air Smit h ...

  • Smith Cast Iron Boilers GS110W - page 9

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 9 Figure 9 - V er tical Negative Pressure Masonry Chimney System using Outside Comb ustion Air (Cat. I) Figure 10 - V er tical P ositive Pressure V enting using Outside Comb ustion Air (Cat. III) ...

  • Smith Cast Iron Boilers GS110W - page 10

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 10 Cer tified v ent systems are manufactured b y the following companies: Heat-f ab , Inc. 130 Industrial Blvd., T ur ners F alls, MA 01376 (800) 772-0739. Z-Flex U.S., Inc. 20 Commerce P ar k North, Bedford, NH 03110-6911 (800) 654-5600. Protech Systems Inc. 26 Ganse voor t ...

  • Smith Cast Iron Boilers GS110W - page 11

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 11 Horizontal v ent systems shall ter minate at least 4 feet (1.3 m) below , 4 f eet (1.3 m) hor izontally from or 1 f oot (0.23 m) abov e any door , window or gra vity air inlet into any b uilding. It must not terminate less than 4 feet (1.3 m) horizontally from, and in no c ...

  • Smith Cast Iron Boilers GS110W - page 12

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 12 VER TICAL VENT POSITIVE PRESSURE SYSTEMS See Figure 11. The vent materials used in vertical positive pressure vent systems must be certified to UL 1738 for installations in the United States, ULS636 for installations in Canada. The maximum v ent lengths are listed in T abl ...

  • Smith Cast Iron Boilers GS110W - page 13

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 13 Figure 11 - V er tical P ositive Pressure V enting (Cat. III) The vent connector should be sloped up to ward the chimney 1/4" per foot. Ensure that the vent connector is properly supported and each connection securely fastened with at least 3 corrosion resistant sheet ...

  • Smith Cast Iron Boilers GS110W - page 14

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 14 Dans la mesure du possible , fermer toutes les portes et les fenêtres du bâtiment et toutes les portes entre l'espace où les appareils toujours raccordés du système d'év acuation sont installés et les autres espaces du bâtiment. Mettre en marche les séch ...

  • Smith Cast Iron Boilers GS110W - page 15

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 15 W ARNING: Failure to connect a condensate trap or pump to the flue collector can result in excessive le vels of carbon monoxide whic h can cause severe per sonal injur y or death! HEA TING SYSTEM PIPING CA UTION: All heating system piping m ust be installed in accor dance ...

  • Smith Cast Iron Boilers GS110W - page 16

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 16 Ensure that the boiler is level from front to back and from side to side. Use metal shims to le vel the boiler . NEVER use combustible materials for shims. Bypass Piping CA UTION: Never connect this boiler directl y to a large v olume system, in-floor radiant system, sno w ...

  • Smith Cast Iron Boilers GS110W - page 17

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 17 Piping For Use With Cooling Units The boiler , when used in connection with a refrigera-tion system must be installed so the chilled medium is piped in parallel with the boiler . Appropriate valves m ust be used to prevent the chilled water from entering the boiler . When ...

  • Smith Cast Iron Boilers GS110W - page 18

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 18 GAS SUPPL Y PIPING The GS110 hot water boiler comes from the f actor y ready to be piped to the gas supply . The gas supply can be piped from the left or right side of the boiler . If f or any reason the boiler is not for the type of gas av ailable at the installation site ...

  • Smith Cast Iron Boilers GS110W - page 19

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 19 installed in Canada. Install a separate 120 volt 15 amp circuit f or the boiler . A properly rated shut-off switch should be located at the boiler . The boiler must be grounded in accordance with the authority having jurisdiction, or if none, the latest re vision of the Na ...

  • Smith Cast Iron Boilers GS110W - page 20

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 20 Figure 19A - Wiring Connection Diagram ...

  • Smith Cast Iron Boilers GS110W - page 21

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 21 Figure 19B - Wiring Ladder Dia gram B ...

  • Smith Cast Iron Boilers GS110W - page 22

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 22 W ARNING: If you do not follo w these instrucitons exactl y , a fire or explosion may result causing property damage, personal injury or loss of life. FOR Y OUR SAFETY READ BEFORE OPERA TING A . This appliance does not hav e a pilot. It is equipped with an ignition de vice ...

  • Smith Cast Iron Boilers GS110W - page 23

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 23 POUR V O TRE SÉCURITÉ LISEZ A V ANT DE METTRE EN MARCHE INSTRUCTIONS DE MISE EN MARCHE COÙPURE DE L'ARRIVE DE GAZ A LA CHA UDIERE A VERTISSEMENT . Quinconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclenc her un incendie o ...

  • Smith Cast Iron Boilers GS110W - page 24

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 24 BOILER SET UP NO TE: Before starting the boiler , turn off the electrical supply going to it. Make sure that gas is av ailable at the gas valve inlet. Open the valves in the return and supply piping. Failure to take these precautions will prevent the boiler fr om operation ...

  • Smith Cast Iron Boilers GS110W - page 25

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 25 Figure 20- Air and Manifold Pressure BOILER CHECKING & ADJUSTMENT INPUT RA TE Gas appliances are rated based on sea level operation with no adjustment required at elevations up to 2000 f eet. At ele vations abov e 2000 f eet, input ratings should be reduced by 4% for e ...

  • Smith Cast Iron Boilers GS110W - page 26

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 26 Main Burner Flame A properly adjusted main burner flame will produce a tight blue flame pattern about 1/2 inch tall from the burner’ s surf ace, Figure 21. A yellow floating or tall stringy flame is not nor mal and must be corrected. W ARNING: Y ellow , floating flames i ...

  • Smith Cast Iron Boilers GS110W - page 27

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 27 INSTR UCTIONS T O THE INST ALLER The INST ALLER must giv e this copy of the INST AL- LA TION AND OPERA TING INSTR UCTIONS to the boiler owner and make sure that the owner or operator has a basic understanding of the following: 1 . The operating instructions, the type of ig ...

  • Smith Cast Iron Boilers GS110W - page 28

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 28 ...

  • Smith Cast Iron Boilers GS110W - page 29

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 29 SER VICE AND REPLA CEMENT P AR TS LIST 1 Rear , T op , Front & Inner P anels 59450 1 59451 1 59452 1 59453 1 59454 1 2 Left Jacket Side Panel 59495 11111 3 Right Jacket Side Panel 59496 11111 4 Gas V alve , White Rodgers 36E65 50064 1 1 1 Gas V alve, White Rodgers 36D2 ...

  • Smith Cast Iron Boilers GS110W - page 30

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 30 Ref # Name of Part P a r t # 34567 Model Size with Item Quantities Below 29 Thermal Switch 59481 11111 30 Block Assemb ly 72076 1 72077 1 72078 1 72079 1 72080 1 31 Jacket Bracket 59456 66666 32 Frame Cross Members 59459 1 59460 1 59461 1 59462 1 59463 1 33 Flue Collector ...

  • Smith Cast Iron Boilers GS110W - page 31

    GS110 DIRECT VENT BOILER INST ALLA TION AND OPERA TION INSTR UCTIONS Page 31 ...

  • Smith Cast Iron Boilers GS110W - page 32

    260 NORTH ELM STREET WESTFIELD, MA 01085 TEL. (413) 562-9631 F AX: (413) 562-3799 ...

Manufacturer Smith Cast Iron Boilers Category Boiler

Documents that we receive from a manufacturer of a Smith Cast Iron Boilers GS110W can be divided into several groups. They are, among others:
- Smith Cast Iron Boilers technical drawings
- GS110W manuals
- Smith Cast Iron Boilers product data sheets
- information booklets
- or energy labels Smith Cast Iron Boilers GS110W
All of them are important, but the most important information from the point of view of use of the device are in the user manual Smith Cast Iron Boilers GS110W.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Smith Cast Iron Boilers GS110W, service manual, brief instructions and user manuals Smith Cast Iron Boilers GS110W. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Smith Cast Iron Boilers GS110W.

A complete manual for the device Smith Cast Iron Boilers GS110W, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Smith Cast Iron Boilers GS110W by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Smith Cast Iron Boilers GS110W.

A complete Smith Cast Iron Boilers manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Smith Cast Iron Boilers GS110W - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Smith Cast Iron Boilers GS110W, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Smith Cast Iron Boilers GS110W, that we can find in the current document
3. Tips how to use the basic functions of the device Smith Cast Iron Boilers GS110W - which should help us in our first steps of using Smith Cast Iron Boilers GS110W
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Smith Cast Iron Boilers GS110W
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Smith Cast Iron Boilers GS110W in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Smith Cast Iron Boilers GS110W?

Use the form below

If you did not solve your problem by using a manual Smith Cast Iron Boilers GS110W, ask a question using the form below. If a user had a similar problem with Smith Cast Iron Boilers GS110W it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)