Manual Goodman Split System Condensing Units IO-101G

8 pages 0.37 mb
Download

Go to site of 8

Summary
  • Goodman Split System Condensing Units IO-101G - page 1

    INST ALLA TION & OPERA TING INSTRUCTIONS for SPLIT SYSTEM CONDENSING UNITS All information contained herein is subject to change without notice. Goodman Manufacturing Compan y , L. P. I0-101G 2550 North Loop West, Suite 400, Houston, TX 77092 06/04 ww w .goodmanmfg.com © 2003-2004 Goodman Manufacturing Compan y , L. P. ...

  • Goodman Split System Condensing Units IO-101G - page 2

    2 IO-101G 06/04 INDEX Important Message to Homeowner ...................... 2 Codes and Regulations ....................................... 2 Inspection ............................................................ 2 Replacement Parts .............................................. 2 Important Safety Instructions ............................... 2 Cle ...

  • Goodman Split System Condensing Units IO-101G - page 3

    3 IO-101G 06/04 This “close to the wall” application minimizes exposed tubing and wiring and reduces the space for children to run around the unit. This will help to avoid possible damage to the tubes or wiring and/or personal injur y. Service Access 18" Min. Service Access 18" Min. 10" Min. 10" Min. 10" 10" FIGURE ...

  • Goodman Split System Condensing Units IO-101G - page 4

    4 IO-101G 06/04 consideration is given the weather-tight integrity of the roof. The condensing unit contains moving components and can vibrate; therefore, sound is also a consideration in rooftop application. Since this unit discharges warm condenser air from the top with cooler air being drawn in three sides, plantings can be made in relatively cl ...

  • Goodman Split System Condensing Units IO-101G - page 5

    5 IO-101G 06/04 The recommended procedure for processing and charge adjustment is as follows: 1. Connect vacuum pump to both base valve service ports. 2. Evacuate tubing and evaporator through liquid and suction base valve ports, to 500 microns or less for a minimum of 30 minutes. Close valve to pump and wait 15 minutes. Vacuum should not rise abov ...

  • Goodman Split System Condensing Units IO-101G - page 6

    6 IO-101G 06/04 SPECIAL NOTE: Systems with MORE than 15’ of interconnecting tubing, please refer to Table 5 for line charge allowance per foot of tubing. LINE LIQUID SUCTION O. D. (IN) LINE LINE 1/4 0.22 3/8 0.58 1/2 1.14 5/8 1.86 0.04 3/4 0.06 7/8 0.08 1 1/8 0.15 1 3/8 0.22 LINE CHARGE ALLOWANCE (R-22) (oz./ft.) T ABLE 5 NOTE: System with over 5 ...

  • Goodman Split System Condensing Units IO-101G - page 7

    7 IO-101G 06/04 CONTROLS SHOWN WITH UTILITIES IN 'ON'POSITION LOW VOLTAGE DEFROST RELAY OUTDOOR THERMOSTAT (OPTIONAL) HIGH VOLTAGE DEFROST RELAY AND THERMOSTAT IN 'OFF' POSITION. REVERSING VALVE COIL FAN CAPACITOR HIGH PRESSURE CONTROL CRANKCASE HEATER INTERNAL OVERLOAD LOW PRESSURE CONTROL DEFROST THERMOSTAT COMPONENT CODE OUTD ...

  • Goodman Split System Condensing Units IO-101G - page 8

    8 IO-101G 06/04 NOTE: SPECIFIC ATIONS AND PERFORMANCE D ATA LISTED HEREIN ARE SUBJECT T O CHANGE WITHOUT NOTICE Quality Makes the Difference! All of our systems are designed and manufactured with the same high quality standards regardless of size or efficienc y . We have designed these units to significantly reduce the most frequent causes of produ ...

Manufacturer Goodman Category Air Conditioner

Documents that we receive from a manufacturer of a Goodman Split System Condensing Units IO-101G can be divided into several groups. They are, among others:
- Goodman technical drawings
- Split System Condensing Units IO-101G manuals
- Goodman product data sheets
- information booklets
- or energy labels Goodman Split System Condensing Units IO-101G
All of them are important, but the most important information from the point of view of use of the device are in the user manual Goodman Split System Condensing Units IO-101G.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Goodman Split System Condensing Units IO-101G, service manual, brief instructions and user manuals Goodman Split System Condensing Units IO-101G. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Goodman Split System Condensing Units IO-101G.

Similar manuals

A complete manual for the device Goodman Split System Condensing Units IO-101G, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Goodman Split System Condensing Units IO-101G by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Goodman Split System Condensing Units IO-101G.

A complete Goodman manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Goodman Split System Condensing Units IO-101G - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Goodman Split System Condensing Units IO-101G, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Goodman Split System Condensing Units IO-101G, that we can find in the current document
3. Tips how to use the basic functions of the device Goodman Split System Condensing Units IO-101G - which should help us in our first steps of using Goodman Split System Condensing Units IO-101G
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Goodman Split System Condensing Units IO-101G
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Goodman Split System Condensing Units IO-101G in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Goodman Split System Condensing Units IO-101G?

Use the form below

If you did not solve your problem by using a manual Goodman Split System Condensing Units IO-101G, ask a question using the form below. If a user had a similar problem with Goodman Split System Condensing Units IO-101G it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)