    FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. 6988 V enture St., Delta, BC Canada, V4G 1H4 918-677b MODELS: U32-NG5 Natural Gas U32-LP5 Propane W ARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult an authorized instal ...

  • FPI U32 - page 2

    2 U32-5 FPI Direct V ent Gas Insert Note: Oversize faceplate is 44" x 28" TO THE NEW OWNER Congratulations! Y ou are the owner of a state-of-the-art Gas Insert by FPI. The FPI Gas Insert Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a fi replace, at the fl ick of a switch. The models ...

  • FPI U32 - page 3

    3 U32-5 FPI Direct V ent Gas Insert T ABLE OF CONTENTS OPERA TING INSTRUCTIONS Operating Instructions ................................................ 29 Lighting Procedure ...................................................... 29 Shutdown Procedure ................................................... 29 First Fire .................................. ...

  • FPI U32 - page 4

    4 U32-5 FPI Direct V ent Gas Insert SAFETY LABEL This is a copy of the labels that accompany each U32-5 Gas Insert. We have printed a copy of the contents here for your review . The safety label is located on a plate inside the base of the unit visible when the bottom louver is opened. NOTE: FPI units are constantly being improved. Check the label ...

  • FPI U32 - page 5

    5 U32-5 FPI Direct V ent Gas Insert REQUIREMENTS 5.08: Modifica tions to NFPA-54, Chapter 10 (2) Revise 10.8. 3 by adding the follow ing additional re quirements: (a) For all side wall hor izontally vented ga s fueled equipment in stalled in every dwelling, bui lding or structure use d in whole or in part for residential pu rposes, includi ng those ...

  • FPI U32 - page 6

    6 U32-5 FPI Direct V ent Gas Insert IMPORT ANT MESSAGE SA VE THESE INSTRUCTIONS The FPI Gas Insert must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the building authority having jurisdiction to determine the need for a permit prior to starting the installation. NOTE: Failur ...

  • FPI U32 - page 7

    7 U32-5 FPI Direct V ent Gas Insert A B D E C MANUF ACTURED MOBILE HOME ADDITIONAL REQUIREMENTS 1) Ensure that structural members are not cut or weakened during installation. 2) Ensure proper grounding using the #8 ground lug provided. 3) Appliance must be anchored to the fl oor with the supplied anchoring methods. MA TERIALS REQUIRED No electrica ...

  • FPI U32 - page 8

    8 U32-5 FPI Direct V ent Gas Insert VENTING THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SER VING A SEP ARA TE SOLID FUEL BURNING APPLIANCE. This appliance is designed to be attached to two 3" (76mm) co-linear aluminium fl ex running the full length of the chimney . The fl ue length must be a minimum length of 8 ' (2.44m) and a ...

  • FPI U32 - page 9

    9 U32-5 FPI Direct V ent Gas Insert OPTIONAL BRICK P ANEL 1) Unwrap the brick pattern panels from the protective wrapping. 2) Remove the glass front if it is already installed, see "Standard Flush Door" section. 3) Put the rear brick panel fl at against the back of the unit. Diagram 1 Diagram 2 GAS PIPE PRESSURE TESTING The appliance mus ...

  • FPI U32 - page 10

    10 U32-5 FPI Direct V ent Gas Insert LOG SET INST ALLA TION Log kit (Part # 425-930) contains the following pieces: a) 27-31 Rear Log b) 27-32 Middle Left Log c) 27-33 Front Log d) 27-34 Middle Right Log e) 27-35 Left Log f) 27-36 Right Log g) 902-154 Embers Lava h) 902-179 V ermiculite i) 902-153 Rock Wool j) 946-669 Platinum Embers (supplied with ...

  • FPI U32 - page 11

    11 U32-5 FPI Direct V ent Gas Insert 6) Fit the groove in log 27-34 into the tab on the right side of the burner. Rest the other end of log 27-34 on the notch in log 27-33. 5) Fit log 27-33 into the pins at the front of the burner . 7) Fit the bottom end of log 27-35 into the pin in log 27-33 and rest the top end of log 27-35 on the notch in log 27 ...

  • FPI U32 - page 12

    12 U32-5 FPI Direct V ent Gas Insert 8) Fit log 27-36 into the pins on logs 27-33 and 27-31. 9) Place embers along the front of the burner as shown. Ensure not to cover any burner ports. 27-35 27-31 27-33 27-36 27-36 Embers 10) Separate platinum embers and place on the burner just in front of the logs as shown. Avoid stacking platinum embers. Plati ...

  • FPI U32 - page 13

    13 U32-5 FPI Direct V ent Gas Insert Completed Log Set Installation 27-33 27-32 27-31 27-36 27-34 27-35 INST ALLA TION ...

  • FPI U32 - page 14

    14 U32-5 FPI Direct V ent Gas Insert Diagram 3 Rear View: T rim Assembly Diagram 2 Rear View: Faceplate Assembly Diagram 1 REGENCY F ACEPLA TE & TRIM INST ALLA TION 1) Lay the faceplate panels fl at, face down on something soft so they don't scratch. 2) T ake the top faceplate and align the holes in it with the holes in the side panels. U ...

  • FPI U32 - page 15

    15 U32-5 FPI Direct V ent Gas Insert T o remove the fl ush door, reverse the above steps. NOTE: The chain must rest on TOP of the gas inlet pipe never under it. Diagram 3 Diagram 2 Use the hook to pull the spring out until you can put the hook into the slot on the bottom door bracket. Repeat for 2nd spring. See diagram 3. Diagram 1b OPTIONAL FLUSH ...

  • FPI U32 - page 16

    16 U32-5 FPI Direct V ent Gas Insert BA Y LOUVERS 1) Install top louver by sliding the two bracket clips into the brackets located on top of the bay door . See below . The fi tted louver leaves a small gap between faceplate bottom and louver top. Note: If any maintenance etc. must be done in the fi rebox, fi rst remove the Bay louvers and door . ...

  • FPI U32 - page 17

    17 U32-5 FPI Direct V ent Gas Insert THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 1) Shut off the gas supply . 2) Remove the louvers (and bay door if it is installed). 3) Open the fl ush door and remove the door . 4) Remove the logs and embers (if already installed). Remove the 2 screws, push Burn ...

  • FPI U32 - page 18

    18 U32-5 FPI Direct V ent Gas Insert Installation of the DC Sparker: 16) V erify that if the conversion is from NG to LPG, the screw must be re- assembled with the red o-ring visible (Fig. 5). LPG Configuration Red o-ring visible Fig.5 17) R e-assemble the black protection cap (Fig. 6). Fig. 6 W ARNING! Also check that the pilot and main burner inj ...

  • FPI U32 - page 19

    19 U32-5 FPI Direct V ent Gas Insert 27) Run the other end of the ground wire and DC spark generator wires through the bushing on the heat shield. 29) Plug the DC spark generator wires to the DC Sparker . 30) Connect the ground wire to the DC Sparker mounting bracket. Heat Shield 33) Find a location which is not too hot and is easy to reach for cha ...

  • FPI U32 - page 20

    20 U32-5 FPI Direct V ent Gas Insert FULL SCREEN DOORS 1) Hold the full screen door frame up against the unit in order to make the following wire connections. Pull the ON/OFF connector wires from the fi rebox and connect them to the switch. Connect the fan switch wires with the wire connectors from the fan speed control. Place clips over wires and ...

  • FPI U32 - page 21

    21 U32-5 FPI Direct V ent Gas Insert 5) Place Bottom Frame near hinge. Flip hinge over Bottom Frame and secure with 3 screws. 4) Install Spring Hinges on the Left and Right Side of the bottom of the fi rebox using 2 screws per hinge. 6) The T op Frame is held in place by friction fi t, if the frame needs to be adjusted; bend the bracket according ...

  • FPI U32 - page 22

    22 U32-5 FPI Direct V ent Gas Insert HAMPT ON ® CAST F ACEPLA TE INST ALLA TION 1) Lay the faceplate panels fl at, face down on something soft so they don't scratch. 2) Attach the side fi ller brackets to the left and right sides using 3 screws and washer per side. 3) Attach the right and left cast sides to the top using 2 screws per side. ...

  • FPI U32 - page 23

    23 U32-5 FPI Direct V ent Gas Insert HAMPT ON ® CAST GRILL INST ALLA TION Note: The top grill should be placed with the curved cut-out facing up. 11 ) Mount the cast faceplate panels onto the insert body , sliding the side fi ller brackets into the space between the glass and the fi rebox. Secure using the 4 remaining black screws, 2 per side. U ...

  • FPI U32 - page 24

    24 U32-5 FPI Direct V ent Gas Insert IMPORT ANT : Please use the gloves provided when handling the Kensington ® Front to avoid fi ngerprints. 3) Slide the T abs on the Blanking Plate into the slots located on Front and secure using 2 screws. Kensington ® Front Blanking Plate T abs 1) Place the Kensington ® Front up against the unit , but do not ...

  • FPI U32 - page 25

    25 U32-5 FPI Direct V ent Gas Insert THE KENSINGT ON ® 2-P ANEL DOOR INST ALLA TION 3) Hook the Left Side Screen Door to the Door Frame by placing the door hinges (top & bottom) over the pins on the Door Frame. Repeat for Right Side Screen Door . Note: It will be easier to put the Screen Door in place by starting with the bottom hinge. 2) Moun ...

  • FPI U32 - page 26

    26 U32-5 FPI Direct V ent Gas Insert OPTIONAL REMOTE CONTROL Use the FPI Remote Control Kit approved for this unit. Use of other systems may void your warranty . The remote control kit comes with a hand held transmitter , a receiver and a wall mounting plate. 1) Choose a convenient location on the wall to install the receiver and the receptacle box ...

  • FPI U32 - page 27

    27 U32-5 FPI Direct V ent Gas Insert Piezo Ignitor Black Red To Thermocouple IN Pilot Assembly Thermostat (Optional) (Millivolt) Remote Receiver (Optional) (Millivolt) Remote T ransmitter (Optional) ON OFF Regency Burner ON OFF Ground Neutral Live Black Black Black Red Minimum Convection Air T emp. Switch ON OFF Rotary S peed Control 120V AC Green ...

  • FPI U32 - page 28

    28 U32-5 FPI Direct V ent Gas Insert For PROP ANE Units and Units Equipped with DC Spark Boxes* *For installation of the DC Spark Box refer to the LP Conversion instructions in this manual. INST ALLA TION ...

  • FPI U32 - page 29

    29 U32-5 FPI Direct V ent Gas Insert The glass panel may require cleaning after the unit has cooled down. DO NOT A TTEMPT TO CLEAN THE GLASS WHILE IT IS HOT . No te: When the glass is cold and the appliance is lit, it may cause condensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up. DO ...

  • FPI U32 - page 30

    30 U32-5 FPI Direct V ent Gas Insert COPY OF LIGHTING INSTRUCTION PLA TE OPERA TING INSTRUCTIONS sounds. Y ou should also be aware that as there are temperature changes within the unit these sounds will likely re-occur . Again, this is normal for steel fi reboxes. Blower Thermodisc: When this thermally activated switch turns ON it will create a sm ...

  • FPI U32 - page 31

    31 U32-5 FPI Direct V ent Gas Insert MAINTENANCE GENERAL VENT MAINTENANCE Conduct an inspection of the venting system semi-annually . Recommended areas to inspect as follows: 1) Check the V enting System for corrosion in areas that are exposed to the elements. These will appear as rust spots or streaks, and in extreme cases, holes. These components ...

  • FPI U32 - page 32

    32 U32-5 FPI Direct V ent Gas Insert F AN MAINTENANCE If your fan requires maintenance or replacement, access to the fan is through the plate on the rear wall of the fi rebox. NOTE: the unit MUST NOT be operated without the fan access panel securely in place. Caution: Label all wires prior to disconnecting when servicing controls. Wiring errors ca ...

  • FPI U32 - page 33

    33 U32-5 FPI Direct V ent Gas Insert MAINTENANCE V AL VE REPLACEMENT 1) Shut off the gas supply . 2) Remove the louvers (and bay door if it is on). 3) Open the fl ush door and remove the door . 4) Remove the logs and brick panels. 5) Remove the grate by loosening the two screws and sliding the grate out. 12) Remove the valve by removing the 4 scre ...

  • FPI U32 - page 34

    34 U32-5 FPI Direct V ent Gas Insert P ARTS LIST 1) 420-122 Fan Access Panel 2) 420-142 Gasket - Fan Access Panel 422-518/P Fan Assembly: 3) 910-215/P Fan Motor (120 V) 5) 910-750 Power Cord (120 V) 910-752 Wire Harness (intermediate) 7 ) 9 1 0 - 1 4 2 Thermodisc-Fan Auto ON/OFF 8) * Fan Switch Cover 9) * Thermodisc Bracket 10) 420-140 Flue Restric ...

  • FPI U32 - page 35

    35 U32-5 FPI Direct V ent Gas Insert P ARTS LIST 423-574/P V alve Assembly - NG 423-576/P V alve Assembly - LP 52) 910-478 V alve - SIT NG / LP 53) 910-190 Ignitor Piezo and Nut 55) * V alve Tray 58) 904-240 Burner Orifi ce Nat. Gas #37 904-390 Burner Orifi ce LP # 52 936-170 Orifi ce Gasket 66) 910-038 Pilot Assembly - 3 Flame (NG) 910-039 Pilo ...

  • FPI U32 - page 36

    36 U32-5 FPI Direct V ent Gas Insert P ARTS LIST Bay Door 420-931 Complete Bay Door with Black Trim 10 2) * Glass Retainer Side (T op & Btm) 10 3 ) * Glass Retainer Front (T op & Btm) 106) 940-315/P Side Glass 107) 936-243 Gasket 108) 940-314/P Center Glass 1 10) 420-244 Bay Brick Panel - Steel 1 1 1) * Door Trim 1 12) 904-196 1" Round ...

  • FPI U32 - page 37

    37 U32-5 FPI Direct V ent Gas Insert L O G O P L A T E H E R E LOGOPLATEHERE L O G O P L A T E H E R E LOGOPLATEHERE 92 95 ST ANDARD SIZE DET AIL 'A' 91 93 REAR VIEW FRONT VIEW 96 68 60 99 70 FRONT VIEW 94 99 51 59 65 97 98 71 72 73 FRONT VIEW OVERSIZE 98 180 181 CUSTOM F ACEPLA TES 74 97 199 CUSTOM F ACEPLA TES REAR VIEW 190 190 190 199 ...

  • FPI U32 - page 38

    38 U32-5 FPI Direct V ent Gas Insert 202 205 187 189 188 203 195 194 194 207 201 402-971** Cast Faceplates (Set) 187) 910-246 Burner On/Off Switch 188) 910-330 Fan Speed Control (120 V) 189) 904-733 Knob - Black Cast Surround 201) * Cast Faceplate - Right 202) * Cast Faceplate - T op 203) * Cast Faceplate - Left 205) * Flush Glass Frame 194) * Moun ...

  • FPI U32 - page 39

    39 U32-5 FPI Direct V ent Gas Insert W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T eam carefully inspects each unit thoroughly before it leaves our facility . FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the ...

  • FPI U32 - page 40

    Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ...

Manufacturer FPI Category Indoor Fireplace

Documents that we receive from a manufacturer of a FPI U32 can be divided into several groups. They are, among others:
- FPI technical drawings
- U32 manuals
- FPI product data sheets
- information booklets
- or energy labels FPI U32
All of them are important, but the most important information from the point of view of use of the device are in the user manual FPI U32.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals FPI U32, service manual, brief instructions and user manuals FPI U32. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product FPI U32.

Similar manuals

A complete manual for the device FPI U32, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use FPI U32 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of FPI U32.

A complete FPI manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual FPI U32 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the FPI U32, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the FPI U32, that we can find in the current document
3. Tips how to use the basic functions of the device FPI U32 - which should help us in our first steps of using FPI U32
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with FPI U32
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of FPI U32 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning FPI U32?

Use the form below

If you did not solve your problem by using a manual FPI U32, ask a question using the form below. If a user had a similar problem with FPI U32 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)