  • Friedrich WY13 - page 1

    I nsta l l at io n an d O p e r at io n M an u al A ir Co nd it io ne r s and He at P umps 115-V olt : WS08, WS10, WS14 230 - V olt : WS10, WS13, WS16, WE10, WE13, WE16, WY10, WY13 Thru -the-w all 920 - 0 07 - 13 (8- 07) Temp/Hour C o o l M o n e y S a v e r ® F a n O n l y C l o c k S t a r t T i m e S t o p T i m e P o w e r Fan Speed Mode P M T ...

  • Friedrich WY13 - page 2

    2 920-007-13 T abl e of Cont ents Int rod u ct io n Econ omizing Ti ps ............................................................................................................. ............................................................................................................... 3 WS models How to op erate your Friedr ic h r oom air c ...

  • Friedrich WY13 - page 3

    3 920-007-13 Y our new Friedrich Room A ir Condit ioner has been c arefully engineered and man u fac ture d to give you many y ears of de pend able, ef fi cient operation, keeping your ro om at a c omfor t able temperature and hu mid i ty level. Many e xt ra fea tures have been built into your Friedrich Room A ir Condit ioner to assure quiet opera ...

  • Friedrich WY13 - page 4

    4 920-007-13 T o s tar t unit If your air condit ioner is installed and plugged into a prop er re c ep t a c le, it is ready to go. The fi rst time the un it i s started, th e compressor wil l delay for three minutes. See Automatic Comp onent Protection on the following page. 1 T o uch the Powe r but ton once. The unit will automat ic ally be in C ...

  • Friedrich WY13 - page 5

    5 920-007-13 T emp/Hour Cool Money Saver ® Fan O n ly Clock Start Time Stop Time Po w e r Fan Speed Mode PM Timer On/Of f Set Hour 72 2 3 4 8 9 10 11 12 13 1 6 5 7 23 4 10 11 12 14 1 6 5 7 9 8 13 T emp/Hour Po w e r PM Cool Fan O n ly Heat Clock Start Time Stop Time Smart Fan Fan Speed Mode Timer On/Of f Money Saver Set Hour 72 Fig u re 1 : WS Mod ...

  • Friedrich WY13 - page 6

    6 920-007-13 How to c lea n the ai r filt er Y o ur F riedr ich ro om air condit ioner is equipped with a Per mafoam reusable air fi lter which is not af fec ted by washing. The fi lter ser ves to remove dust, pollen, and other impurities f rom the air . KEE P THE FI L T ER CLE AN - A cl ogged, dir t y fi lter w ill reduc e the operating ef fi ...

  • Friedrich WY13 - page 7

    7 920-007-13 How to c han ge ai rflow dire c tion The DISCH ARGE G RILLE is inst alled at the fac tor y to provide 45 ˚ upward air fl ow into the r oom. (Directi on 1 in Figure 5). If a v er tic al air fl ow is desired (D irection 2) , the direction c an be change d by rotating the DISCH ARGE G RILLE. Unplug the air c onditioner . R e m o v e t ...

  • Friedrich WY13 - page 8

    8 920-007-13 Fig u re 6 TEST RESET W ARNING TE S T BE F O R E E AC H U S E 1 . PR E SS R E S ET BUTTON 2 . P LU G L DCI I NTO P O W E R R E C E P T AC LE 3. PR E SS TE S T BUTTON, R E S ET BUTTON S HOUL D P O P U P 4. PR E SS TE S T BUTTON, F O R U S E D O NOT U S E IF A BOVE TE S T FAI L S W HEN GR EEN L IG HT IS ON I T IS W O R K I N G PR O P E R ...

  • Friedrich WY13 - page 9

    9 920-007-13 Won ’ t c o ol If the unit operates, but won’t co ol, determine if the c ontrols are proper ly set. Wait three minutes before setting the t her mo stat to a coo ler positi on in order to check c ontro l sett ings. Check the fi lter and clean it thor oughly , if needed. Check to s ee if the vent door is close d. Check to see if th ...

  • Friedrich WY13 - page 10

    10 920-007-13 Wall pr epar a tion STEP 1 The wall opening required for a WSC S LEEVE is 1 7 ¼" high by 27 ¼ " wide. STEP 2 LINTELS must be used in opening of br ick veneer and masonr y walls to suppor t the mater ial above the WSC SLEEV E. The follow ing considerat ions should also be given: I ns tall ati on i ns tru c ti ons for WS C s ...

  • Friedrich WY13 - page 11

    11 920-007-13 I ns t a lla tion requir emen ts STEP 1 T h e W S C S L E E V E s h o u l d b e p o s i t i o n e d s o t h a t t h e DR A IN E X TENSI ON extends a minimum of 9 ⁄ 16 " beyond the OUTSI DE WALL (See Figure 7). STEP 2 The WSC SLEEV E must extend a minimum of ⅞ " be yond the IN SIDE WALL . STEP 3 The WSC SLEEV E must be in ...

  • Friedrich WY13 - page 12

    12 920-007-13 These instr uct ions are provided for installat ion of WallMaster air condit ioner chassis mo dels into thru -the -wall sleeves. This chassis has bee n UL ap prov ed with the slee ve list ed on the serial na meplat e of th i s c ha ss is . Im portan t wa rranty i nf orm a ti on is prov id ed on pa ges 1 7 and 18. K eep these instr uct ...

  • Friedrich WY13 - page 13

    13 920-007-13 These instr uct ions are provided for installat ion of WallMaster air condit ioner chassis mo dels into thru -the -wall sleeves. This chassis has bee n UL ap prov ed with the slee ve list ed on the serial na meplat e of th i s c ha ss is . Im portan t wa rranty i nf orm a ti on is pro vid ed on pa ges 1 7 and 18. K eep these instr uct ...

  • Friedrich WY13 - page 14

    14 920-007-13 STEP 5 CHASSIS SEAL GA SKET INST ALLA TION: After installing the shell, slide the c hassis into the shell stopping approximately 3" from f ull inser tion. Stuf f t he chassis seal gasket one inch deep between the chas sis and the shell ( see Figure 1 1 ) . Make sure the gaske t is installed beginning from th e lower right side c ...

  • Friedrich WY13 - page 15

    15 920-007-13 DK ( Drai n Kit) In the event that the outdoor temperature dr ops below 37°F , any water that re mains in the chas sis basepan is drained into the sleeve pan on WE and W Y mo dels to prevent freezing. (NO TE: In the cooling m ode of the WS, WE and W Y models, c ondensate over fl ow is p ossible in very humid c limates ) . For these ...

  • Friedrich WY13 - page 16

    16 920-007-13 Friedrich Air Conditioning Company P.O. Box 1540 San Antonio, TX 78295 210.357.4400 www.fr iedrich.com WALLMASTER £ THRU-THE-WALL AIR CONDITIONERS LIMITED WARRANTY FIRST YEAR A NY PA RT: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRIC ...

  • Friedrich WY13 - page 17

    17 920-007-13 Friedrich wants you to remain pleased with your Room Air Conditioner . Should further assistance be needed con cern ing this warranty , contact: RAC W arranty , Service and Parts Friedrich Air Conditioning Co. P .O. Box 1540 San Antonio, TX 78295-1540 Y our personal warranty registration recor d AL W A YS U SE F RIEDRICH F A CT OR Y A ...

  • Friedrich WY13 - page 18

    18 920-007-13 ...

  • Friedrich WY13 - page 19

    19 920-007-13 ...

  • Friedrich WY13 - page 20

    FRI ED RI CH A IR CO ND ITI O NI NG CO. Post O f fi ce B ox 1 5 4 0 • San A ntonio, T exas 7829 5 - 154 0 4200 N . Pan Am E xp res sway • San Antoni o, T exas 7821 8 - 521 2 21 0) 357 - 4 4 0 0 • F A X (21 0) 357 - 4 4 80 ww w .fri ed rich .com Printe d in the U.S. A . 920 - 0 07 - 13 (8- 07) ...

Manufacturer Friedrich Category Air Conditioner

Documents that we receive from a manufacturer of a Friedrich WY13 can be divided into several groups. They are, among others:
- Friedrich technical drawings
- WY13 manuals
- Friedrich product data sheets
- information booklets
- or energy labels Friedrich WY13
All of them are important, but the most important information from the point of view of use of the device are in the user manual Friedrich WY13.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Friedrich WY13, service manual, brief instructions and user manuals Friedrich WY13. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Friedrich WY13.

Similar manuals

A complete manual for the device Friedrich WY13, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Friedrich WY13 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Friedrich WY13.

A complete Friedrich manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Friedrich WY13 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Friedrich WY13, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Friedrich WY13, that we can find in the current document
3. Tips how to use the basic functions of the device Friedrich WY13 - which should help us in our first steps of using Friedrich WY13
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Friedrich WY13
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Friedrich WY13 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Friedrich WY13?

Use the form below

If you did not solve your problem by using a manual Friedrich WY13, ask a question using the form below. If a user had a similar problem with Friedrich WY13 it is likely that he will want to share the way to solve it.

Copy the text from the picture