Manual Siemens 7ML19985AB01

112 pages 1.23 mb
Download

Go to site of 112

Summary
  • Siemens 7ML19985AB01 - page 1

    Instruction Manual Nov ember 2005 OCM III open channel ...

  • Siemens 7ML19985AB01 - page 2

    © Siemens Milltronics Process In struments Inc. 2005 Safety Guidelines: Warning notices must be observed to ensure p ersonal safety as well as that of others, and to protec t the product and the connected equipment. These war ning notices are accompanied by a clarification of the level of cautio n to be observed. Qualified Personnel: This device/s ...

  • Siemens 7ML19985AB01 - page 3

    TABLE OF CONTENTS TITL E PAGE A B OUT THIS .. . About T his M a nua l 7 About the O C M - 3 7 SPECIFICA TIONS 9 P rogra mme r 1 0 Tr an s d u c er 11 Tem p er at u r e Sen s o r 11 Cab l i n g 11 C ommunica tion S oftwa re 1 1 I N S T ALLAT I O N In s t al l i n g t h e O CM-3 13 O utline a nd M ounting 1 3 O C M - 3 La yout 1 4 Sy s t em Di ag r a ...

  • Siemens 7ML19985AB01 - page 4

    STA R T UP Gener a l 21 K ey p ad 21 Le ge nd 2 2 I nitia l S ta rt U p 2 2 F unda me nta l C he cks 2 5 OPERA T ION Mem or y 27 Sec u r i ty 27 Un i ts 27 F low C a lcula tion 2 8 Di s p lay 28 Dam pi n g 29 Rel ay s 30 mA Out put 3 0 Fail -Safe 31 F low ra te a nd T ota liz ing 3 1 Logging 3 2 B l an k i n g 34 Tem per at ur e 34 T ime a nd D a t ...

  • Siemens 7ML19985AB01 - page 5

    ‘ D’ PA RA METER LISTING 39 ‘F ’ P AR AM E T E R LI S T I N G 4 1 ‘ P’ PA RA METER L ISTING 43 ‘ U’ PA RA METERS FOR P3 PRIMA RY ELEMENT 51 S imple E xpone ntia l D e vice s, P 3 = 0 5 3 B S-3680 Rec ta ngul a r F lume , P 3 = 1 5 8 B S-3680 R ound N ose H oriz onta l C re st W e ir, P 3 = 2 6 0 B S-3680 Tr ap ezo i d al Fl u me, P3 ...

  • Siemens 7ML19985AB01 - page 6

    7ML 19985A B 01 OCM III 6 ...

  • Siemens 7ML19985AB01 - page 7

    ABOUT THIS ... ABOUT THIS MANUAL Although the O C M - 3 is very ‘a pproa cha ble ’ due its dia logue ca pa bilitie s a nd intuitive ope ra tion, the use r should be fa milia r with this ma nua l. T his ma nua l provide s the use r with the ne ce ssa ry informa tion re quire d to insta ll, sta rt up a nd ope ra te the O C M - 3 . As the O C M - ...

  • Siemens 7ML19985AB01 - page 8

    Th e OCM-3 c o n v ert s t h e h ead m eas u r em en t i n t o f l o w r ate, b u t al s o p r o v i des a ve locity se nsor input f or a pplica tions whe re a flow ve locity me a sure me nt is re quire d to pe rf orm the flow ca lcula tion. The flow ra t e is tota liz e d a nd st ore d in a compre he nsive da t a log t o provide de ta ile d f low ...

  • Siemens 7ML19985AB01 - page 9

    SPECIFICATIONS P owe r: » dc supply: » 9 to 3 0 V D C , 8 W ma x and / or » a c supply: » 100/ 115/200/230 V ac ± 15%, 50/ 60 Hz, 20 VA m ax E nvironme n ta l: » loca tion » indoor / outdoor » al t i t ud e: » 2000 m m ax » am b i ent t em p er at u r e » – 20 t o 50 °C (–5 t o 122 °F) » re la tive humidity » suita ble for outdoo ...

  • Siemens 7ML19985AB01 - page 10

    » i s o l ati o n: 300 V ac c on t i nuous » r elay s : » 3 al ar m /c on t r o l r el ay s » 1 form ’C ’ S P D T conta ct pe r re la y, ra te d a t 5 A at 250 V ac non- inductive or 3 0 V dc » dc output: » + 2 4 V dc » 20 m A av erag e t o 200 m A at 1/10 d u t y cycle ma x Co m m un i c at i o n : » RS-232 o r ± 2 0 mA bipola r curre ...

  • Siemens 7ML19985AB01 - page 11

    B att er y : » 9 V (A NSI / NEDA 1604, PP3 o r eq u i v alen t ) o r 3 V lithium b a tte ry TRANSDUCER Mo d el : » XRS-5* Ref er t o as s o c i ated Tr an s d u c er m anu al . TEMPERATURE SENSOR M ode l: » T S - 2 , LT S - 1 or LT S - 1 C Ref er t o as s o c i ated Tem p er atu r e Sen s o r m anu al . CABLING Tr ans d u c er: » RG-62U c oax i ...

  • Siemens 7ML19985AB01 - page 12

    Auxilia ry I nput: » Be lde n 8760 or eq u iv al en t 24 V Ou t p u t : » B eld en 8760 COMMUNICATION SOFTWARE M illtronics U tilitie s S of twa re on st a nda rd P C floppy disk f or D O S 3 . 1 a nd up. 7ML 19985A B 01 OCM III 12 ...

  • Siemens 7ML19985AB01 - page 13

    INSTALLATION Insta lla tion s hal l only be perfor med by qu ali fied perso nnel and in accor dance with local g overning regu lations. INSTALLING THE OCM-3 T he O C M - 3 should be mounte d in a cle a n, dry a re a tha t is: within the a mbie nt te mpe ra t ure ra nge a nd suita ble for the spe cifie d e nclosure . T he front cove r should be a cc ...

  • Siemens 7ML19985AB01 - page 14

    OCM-3 LAYOUT boa rd A boa rd B displa y boa rd Hazardous volt age present on tr ansduc er t ermi nals duri ng opera ti on. dc ter minal s shal l be suppl ied f rom SELV source i n accor dance wit h I EC 101 0- 1 Anne x H. Relay c onta ct t er minal s ar e for use wi th equi pment havi ng no acce ssi ble live parts and wir ing h avin g ins ulatio n ...

  • Siemens 7ML19985AB01 - page 15

    SYSTEM DIAGRAM 98/03/05 OCM- 3 M i ll tronics t ra nsdu ce r, s ee S p eci fic ati o ns M il lt ronics T S - 2 , t em p er at u re s en s o r customer de vi ce c u s to m er alar m , pump or cont r ol de vice customer de vi ce custome r de vi ce customer de vi ce Mi ll tr o ni c s CVCC mA output re la y output a uxilia ry input ve locity input RS-2 ...

  • Siemens 7ML19985AB01 - page 16

    INSTALLING THE TRANSDUCER INSTALLING THE TEMPERATURE SENSOR Max c ab l e r u n 183 m (600 f t ) o f R G - 6 2 U or e quiva le nt . C a ble must be run in a grounde d me ta l conduit with no othe r ca bling (e xce pt T e mp. S e nsor ca ble ) . G round shie ld a t O C M - 3 only. I nsula te shie ld a t junctions to pre ve nt ina dve rte nt grounding ...

  • Siemens 7ML19985AB01 - page 17

    mA OUTPUT RELAYS All re la ys a re ce rtifie d for use in e quipme nt whe re the short circuit ca pa city of the circuits in which the y a re conne cte d is li mite d by fuse s ha ving ra tings not e xce e ding the ra ting of the re la ys. i s o lat ed 0 o r 4 t o 20 m A o u tp ut (P26) i nt o 1 K Ω l oa d ma ximu m. W iring shou ld conform to st ...

  • Siemens 7ML19985AB01 - page 18

    SYNCHRONIZATION W he re two to a ma ximum of twe lve tra nsduce rs will be sha ring a common conduit the O C M - 3 s should be synchroniz e d. I n orde r to synchroniz e O C M - 3 s: » re move jumpe r J1 on boa rd A on a ll but one O C M - 3 » inte rconne ct the S Y N C te rmina l ( T B1 - 2 0 ) of a ll O C M - 3 s. I n sure tha t a ll O C M - 3 ...

  • Siemens 7ML19985AB01 - page 19

    POWER CONNECTIONS T h e O C M - 3 powe r supply a cce pts 100, 115, 200 or 230 V ac p er s w i t c h SW1 ( boa rd B) se le ction a nd 9 to 3 0 V dc. T he O C M - 3 ope ra te s e ithe r unde r a c or dc powe r, or both a c a nd dc live simulta ne ously. I f both a c a nd dc powe r a re live , the O C M - 3 norma lly dra ws powe r from the a c supply ...

  • Siemens 7ML19985AB01 - page 20

    INSTALLING THE MEMORY BACK-UP BATTERY T he me mory ba tte ry, B1 ( se e S pe cifica tions) should be re pla ce d ye a rly to insure me mory ba ck up during le ngthy powe r outa ge s. An on boa rd ca pa citor provide s one hour of me mory re te ntion in orde r to pre se rve the me mory while the ba tte ry is be ing cha nge d. COMMUNICATING VIA COMPU ...

  • Siemens 7ML19985AB01 - page 21

    START UP GENERAL F or t he initia l sta rt up, it is a dvisa ble to use the progra m me r for progra mming the OCM-3. Th e p r og r am m er t r an s m i t s a c od ed i n f r ar ed s i gn al eac h t i m e a k ey i s p r es s ed . T he O C M - 3 is de signe d to a utoma tica lly scroll through the ‘A’, ‘D ’, ‘F ’, ‘P ’ a nd ‘U ’ ...

  • Siemens 7ML19985AB01 - page 22

    LEGEND P re ss the a ssocia te d progra mme r ke y: D ispla y shown on O C M - 3 : P rogra mme r ke y: INITIAL START UP Afte r insta lla tion proce dure s ha ve be e n comple te d, the O C M - 3 ma y be powe re d up. U pon initia l powe ring up, the unit mome nta rily displa ys: a nd the n scrolls through the a va ila ble la ngua ge s: T h e O C M ...

  • Siemens 7ML19985AB01 - page 23

    fa ctory se t se curity code 2.71828 m u s t b e en ter ed if the wrong la ngua ge wa s se le cte d, it ma y be cha nge d he re continue progra m ming by e nte ring the de sire d options a nd a dva ncing until the s c r ol l r et ur n s t o ‘ P0’ . It is t h en ass um ed th at th e u s er has ent er ed al l t he re quire d pa ra me te rs. F o r ...

  • Siemens 7ML19985AB01 - page 24

    I f da ta logging is de sire d, the time a nd da t e must be se t. e. g . 1141 11: 41 a.m . , se conds a re a lwa ys a ssume d to be 0 0 tim e is di spla ye d i n hh:mm:ss e. g . 12101492 Oc t o ber 12, 1492 Th e s t ar t u p p ro c edu r e i s n o w c om p l et e. En t er ‘ F2’ t o p l ac e t h e OCM-3 i n t h e n o r m al ope ra ting mode . N ...

  • Siemens 7ML19985AB01 - page 25

    FUNDAMENTAL CHECKS Fo r ac c u r ate d eter m in at i o n o f f l o w r at e, ac c u r at e h ead m eas u r em en t i s es s en t i al . C he ck the following a nd corre ct if ne ce ssa ry. » c hec k D5 f o r c o r r ec t tem p erat u r e at tr an s du c er l o c at io n . » che ck D 9 for corre ct dista nce from t ra nsduce r to he a d. » c hec ...

  • Siemens 7ML19985AB01 - page 26

    7ML 19985A B 01 OCM III 26 ...

  • Siemens 7ML19985AB01 - page 27

    OPERATION U pon powe r up, t he t ra nsduce r is fire d pe riodica lly a s se t by P 3 6 . A long inte rva l be t we e n me a sure me nt s ma y be de sira ble in orde r to conse rve powe r* whe n ope ra ting the O C M - 3 from a D C source of limite d ca pa city. Th e ec h o i s pr o c es s ed t o d et er m i n e t h e h ead (D0). Th e f lo w r ate ...

  • Siemens 7ML19985AB01 - page 28

    FLOW CALCULATI ON Absolute vs. ra tiome tric T he O C M - 3 ca n be progra mme d to use e ithe r of two me thods ( P 4 ) for ca lcula ting flow f r o m t h e h ead m eas u r em ent : ab s o l u te o r r at i o m et r i c. Th e r es ul t i s t h e s am e re ga rdle ss of the me thod use d. T he principa l diffe re nce is the informa tion tha t must ...

  • Siemens 7ML19985AB01 - page 29

    Flow R ate Field Totali zer Field Relay / No Echo Field Status Field T he O C M - 3 provide s illumina tion for the LC D for e a sie r vie wing of the displa y. I llumina tion ca n be se t ( P 1 4 ) to be norma lly on or off, or a utoma tic. W he n a utoma tic is se le cte d, the lighting will a utoma tica lly go on whe n ke ypa d a ctivity is sens ...

  • Siemens 7ML19985AB01 - page 30

    RELAYS Th r ee o n b o ar d m u l ti p ur p o s e r el ay s ar e p r o v i d ed b y t he O CM-3. P15, 18 an d 21 s et the re spe ctive functions for re la ys 1 , 2 a nd 3 . D e pe nding on the function se le cte d, the se pa ra me te rs de te rmine the ne e d a nd configura tion of the subse que nt re la y c on t r o l p ar am eter s , P16, 17 (r e ...

  • Siemens 7ML19985AB01 - page 31

    T he mA functi on ca n be ove rridde n for te st purpose s by se tting the de sire d mA va lue i n t o F3. Wh en t h e v alu e i s en t er ed , t h e m A o u t p u t w i l l g o t o t h at v al u e. Wh en F 3 i s e xite d, t he mA output will re ve rt to norma l ope ra t ion. Also, se e E mula tion M ode . *In th e c as e o f ab s ol u te c al c ...

  • Siemens 7ML19985AB01 - page 32

    U nde r low flow conditions, a cut- off he a d ( P 4 5 ) ca n be e nt e re d to a void tota liz ing flows occurring a t or be low the flow corre sponding to the cut- off he a d. LOGGING T he O C M - 3 provide s a n e xte nsive logging fe a ture which ca n be vie we d on the loca l displa y or re t rie ve d via the se ria l comm unica tion link. T h ...

  • Siemens 7ML19985AB01 - page 33

    V ie wing the da ta log Th e d ay t o t al i zer (F14) d o es n o t us e t h e m as t er t o t al i zer m u l t i p l i er (P32). It i s p o s si b l e tha t the da ily tota l ove rflows. I n such a ca se the displa y will show + + + . + + . 7ML 19985A B 01 OCM III 33 ...

  • Siemens 7ML19985AB01 - page 34

    BLANKING Bla nking is use d to ignore the z one in front of the tra nsduce r whe re ringing or othe r f al se ec h o i s at a l ev el th at i n t er f er es w i t h t h e p r o c es s i n g o f th e t r u e ec h o . Th e minimum bla nking is fa ctory se t , but ca n be ove rridde n by e n te ring the de sire d d i s t anc e i n to P47. R inging is ...

  • Siemens 7ML19985AB01 - page 35

    T he da ily tota l will be incre a se d proportiona l to the a m ount of time the da y wa s le ngthe ne d. Adjustin g the Date I f the ca le nda r is re se t, t he O C M - 3 will a djust the log da te s a ccordingly, t a king into a ccount le a p ye a rs a nd da ys pe r m onth. EMULATION MODE T he flow ca lcula tion ( P 3 / P 4 ) ca n be che cke d ...

  • Siemens 7ML19985AB01 - page 36

    FLOW VELOCITY INPUT I n some a pplica tions, the flow ca lcula ti o n fo r t h e c h o s en p r i m ar y el em en t r eq u i r es a ve locity input. I n this type of a pplica tion, the tra nsduce r me a sure me nt is use d to c alc u l ate t h e c r o s s s ec t i o n al ar ea o f t h e f l o w . B y m u l t i p l y i n g t h e ar ea w i th t h e d ...

  • Siemens 7ML19985AB01 - page 37

    Th e 0% an d 100% l im i t s o f t h e au x i li ar y i nput must be sca le d using pa ra me te rs P 4 3 an d P44. » se le ct P 4 3 » e nte r the volta ge corre sponding to z e ro he a d » se le ct P 4 4 » e nte r the he a d corre sponding to 5 V . e . g. if the he a d output is 1 V pe r m a nd the output is sca le d for 7 V a t 100% h ead (7 m ...

  • Siemens 7ML19985AB01 - page 38

    ‘D’ PARAMETER LISTING R e fe r to ‘Ope ra tion’ for de ta ils. D0 h ead D1 f lo w r ate D 2 short to ta l * D 3 ma ximum flow ra te D 4 min imum fl ow ra te D5 t emp er at u r e D 6 ma ximum te mpe ra t ure D 7 min imum te mp e ra t ure D 8 ve locity ✧ D 9 nomina l ta rge t ra nge D 1 0 a na log millia mps D11 i n ter n al DC v o l t s D ...

  • Siemens 7ML19985AB01 - page 39

    7ML 19985A B 01 OCM III 40 ...

  • Siemens 7ML19985AB01 - page 40

    ‘F’ PARAMETER LISTING R e fe r to ‘Ope ra tion’ for de ta ils. F 0 e nte r se curity code F 1 e mula tion mode * F 2 run mode F 3 ke ypa d to m A output * F 4 show time se t ti me * F 5 show da t e se t d a te * F 6 softwa re ide ntifi ca ti on num be r F 7 vie w mi n/ m a x da ta F 8 re se t mi n/ m a x da ta * F 9 se lf che ck * F 1 0 cha ...

  • Siemens 7ML19985AB01 - page 41

    7ML 19985A B 01 OCM III 42 ...

  • Siemens 7ML19985AB01 - page 42

    ‘P’ PARAMETER LISTING R e fe r to ‘Ope ra tion’ for de ta ils. P 0 la ngua ge 0 = en gl i s h 1 = f r en c h 2 = i t ali an 3 = g er man 4 = s pan i s h P 1 dime nsiona l units l i n ear v elo c i t y 0 = c ent i m et r es c ent i m etr es p er s ec o n d 1 = inche s inche s pe r se cond 2 = f eet f eet p er s ec o n d 3 = m et res m etr es ...

  • Siemens 7ML19985AB01 - page 43

    1 3 = R e cta ngula r Are a x Vel oc i t y 14 = Tr apezo i dal A rea x Velo c i ty 15 = Mo d i fi ed Tr ap ezo i d al A r ea x Vel oc i t y 16 = U-c han n el A r ea x Velo c i ty 17 = Ci r c ul ar A r ea x Vel o c it y 18 = Gu l l-w i n g A rea x Vel o c it y 19 = Eg g- s h ap ed A rea x Vel o c it y 20 = Un i v er sal A r ea x Vel o c it y P 4 me ...

  • Siemens 7ML19985AB01 - page 44

    P 1 3 displa y da mping 0 = o ff 1 = l o w 2 = m ed 3 = high P 1 4 displa y lighting 0 = o n 1 = au t o o f f 2 = o ff P15 / P18 / P21 r el ay 1 / 2 / 3 as s ig n m en t 0 = not in se rvice 1 = de - e ne rgiz e on loss of e cho 2 = e ne rgiz e on loss of e cho 3 = de - e ne rgiz e on high flow ra te 4 = e ne rgiz e on high flow ra t e 5 = de - e ne ...

  • Siemens 7ML19985AB01 - page 45

    24 = en er gi ze o n l o w A u x . v ol t s 2 5 = de - e ne rgiz e on high Aux. volts 2 6 = e ne rgiz e on high Aux. volts 2 7 = de - e ne rgiz e up control on he a d 2 8 = e ne rgiz e up control on he a d 2 9 = de - e ne rgiz e down control on he a d 3 0 = e ne rgiz e down control on he a d 3 1 = de - e ne rgiz e up control on a na log 3 2 = e ne ...

  • Siemens 7ML19985AB01 - page 46

    P 2 7 mA da mping (se cs) P 2 8 mA options ( e m ula t or tra cking) 0 = don’t tra ck e mula tor 1 = t r ac k emu l at o r P29 f ail -s afe t i m e (s ec s ) P30 f ail -s afe an al o g m o d e 0 = hold la st va lue 1 = a ssume va l ue in P 3 1 P31 f ai l -saf e an al o g m A (d ef aul t v al u e) P32 t o t al i zer m u l ti p l i er 0 = x 1/1000 ...

  • Siemens 7ML19985AB01 - page 47

    P 3 4 printe r mode 0 = ne ve r print 1 = i n t erv al t o b e i n m in u t es 2 = inte rva l to be in hours 3 = print once e a ch da y P 3 5 printe r timing P36 m easu r em en t i n ter v al 0 = 1 s ec 1 = 15 s ec 2 = 30 s ec 3 = 1 m i n 4 = 5 m i n P 3 7 s e ri a l da ta ra te 0 = 300 b au d 1 = 600 2 = 1200 3 = 2400 4 = 4800 5 = 9600 6 = 19200 P ...

  • Siemens 7ML19985AB01 - page 48

    P 3 9 da ta logging ra te fix e d 0 = 1 m i n 3 = 30 1 = 5 4 = 60 2 = 15 5 = 24 h r va ri a ble ( condition ) 6 = 15/1 m i n ( % flow / mi n ) 19 = 60 / 1 ( flow ) 7 = 15 / 5 " 20 = 60 / 5 " 8 = 30 / 1 " 21 = 24 h r / 1 m i n " 9 = 30 / 5 " 22 = 24 h r / 5 m i n " 10 = 60 / 1 " 23 = 24 h r / 15 m i n " 11 = 6 ...

  • Siemens 7ML19985AB01 - page 49

    P42 h ead d et er m i n at i o n 0 = b y OC M-3 1 = by a uxilia ry de vice P43 v o l t s i n f o r zer o h ead P44 h ead at 5 v o l t s i n P45 l o w f l ow c ut -o f f h ead P46 r an g e at zer o h ead P 4 7 bla nking dista nce 7ML 19985A B 01 OCM III 50 ...

  • Siemens 7ML19985AB01 - page 50

    ‘U’ PARAMETERS FOR P3 PRIMARY ELEMENT T he numbe r of ‘U ’ pa ra me t e rs re quire d va rie s a ccording t o the prima ry e le me nt chose n ( P 3 ) a nd the me thod of ca lcula tion ( P 4 ) . T he O C M - 3 prompts the use r by displa ying the ne xt re quire d pa ra me te r, insuring the progra mming is comple te . Th e f ol l ow i n g i ...

  • Siemens 7ML19985AB01 - page 51

    17 Ci r c u l ar A r ea x V e locity 18 Gu l l Wi n g A r ea x V e locity 19 Eg g -s h ap ed A r ea x V e locity 20 Un i v er s al A r ea x V e locity Th e p r im ar y el em en t m u s t b e i n s t al l ed i n ac c o r d an c e w i t h t h e man u f act u r er s re com me nda tions a nd in a ccorda nce with a ll gove rning re gula tions. 7ML 19985 ...

  • Siemens 7ML19985AB01 - page 52

    SIMP LE EXPONEN TIAL DE VICES, P3 = 0 ‘U’ parameters required * U0 = expo nent U1 = k factor (P4 = 0 on ly) T ypica l E xpone ntia l D e vice s: » S utro ( proport iona l) we ir » h ead m eas u r em en t o n l y » R e cta ngula r ( suppre sse d) or T ra pe z oida l ( C ipollet ti) we ir » Ka hfa gi ve nturi » P a rsha ll flume » Le opold ...

  • Siemens 7ML19985AB01 - page 53

    SIMP LE EXPONEN TIAL DE VICES, P3 = 0 TYPICAL SHARP-CRESTED WEIRS Typical Weir P rofiles F or ra te d flows unde r fre e f low conditions, the he a d is me a sure d upstre a m of the we ir p l at e at a mi n im u m d i s t an c e o f 3 ti m es t h e m ax i m u m h ead (i .e. w h er e t h e l i q u i d surfa ce is not a ffe cte d by dra wdown) . t r ...

  • Siemens 7ML19985AB01 - page 54

    SIMP LE EXPONEN TIAL DE VICES, P3 = 0 KHAFAGI VENTURI F or ra te d flows unde r fre e flow conditions, the he a d is me a sure d 1 5 cm ( 6 ") upst re a m from the be ginning of the conve rging se ction. * Th e t r an s d u c er m u s t b e ab o v e t h e m ax i m u m h ead b y at l eas t t h e b l an k i n g v alu e, P47. 15 c m (6" ) pl ...

  • Siemens 7ML19985AB01 - page 55

    SIMP LE EXPONEN TIAL DE VICES, P3 = 0 TYPICAL PARSHALL FLUME F or ra te d flows unde r fre e flow conditions, the he a d is me a sure d a t 2 / 3 the le ngth of the conve rging se ction upstre a m of the be ginning of the throa t se ct ion. * Th e t r an s d u c er m u s t b e ab o v e t h e m ax i m u m h ead b y at l eas t t h e b l an k i n g v ...

  • Siemens 7ML19985AB01 - page 56

    SIMP LE EXPONEN TIAL DE VICES, P3 = 0 TYPICAL LEOPOLD LAGCO F or ra te d flows unde r fre e f low conditions, the he a d is me a sure d a t a point upstre a m re f e re nce d to the be ginning of the conve rging se ction. R e fe r to the following t a ble . conve rging side front 0 h ead t r an sd u cer * dive rging pla n Q throa t point of me a su ...

  • Siemens 7ML19985AB01 - page 57

    BS-3680 Rectangular Flume, P3 = 1 ‘U’ parameters required * ‘U’ parameters calculated ** U0 = a pproach wi dth B U4 = Cv U1 = th roat width b U5 = Cd U2 = h ump height p U6 = A U3 = th roat length L * obta in from ma nufa cture r’s spe cifica tions. ** ca lcula te d by OC M - 3 . M a y be vie we d by a cce ssing ‘U ’ pa ra me te r. Re ...

  • Siemens 7ML19985AB01 - page 58

    BS-3680 RECTANGULAR F LUME 3 t o 4 x h ma x L t r an sd u cer * h 0 h ead p * Th e t r an s du c er m u s t b e ab o v e t h e m ax i m u m h ead b y at l eas t t h e b l an k i n g v al u e, P47. 7ML 19985A B 01 OCM III 59 ...

  • Siemens 7ML19985AB01 - page 59

    BS-3680 Round Nose Horizontal Crest Weir, P3 = 2 ‘U’ parameters required * ‘U’ parameters calculated ** U0 = cres t width b U3 = Cv U1 = cre st he ight p U4 = Cd U2 = c rest length L U5 = A * obta in from ma nufa cture r’s spe cifica tions. ** ca lcula te d by OC M - 3 . M a y be vie we d by a cce ssing ‘U ’ pa ra me te r. Reference A ...

  • Siemens 7ML19985AB01 - page 60

    BS-3680 ROUND NOS E HORIZONTAL CREST WEIR t r an sd u cer * 3 t o 4 x h ma x * Th e t r an s d u c er m u s t b e ab o v e t h e m ax i m u m h ead b y at l eas t t h e b l an k i n g v alu e, P47. 7ML 19985A B 01 OCM III 61 ...

  • Siemens 7ML19985AB01 - page 61

    BS-3680 TRAPEZOIDAL FLUME, P3 = 3 ‘U’ parameters required * ‘U’ parameters calculated ** U0 = a pproach wi dth B U5 = Cv U1 = thro at wid th b U6 = Cd U2 = h ump height p U7 = Cs U3 = th roat length L U8 = A U4 = slop e m * obta in from ma nufa cture r’s spe cifica tions. ** ca lcula te d by OC M - 3 . M a y be vie we d by a cce ssing ‘ ...

  • Siemens 7ML19985AB01 - page 62

    BS-3680 TRAPEZO I DAL FLUME p side t r an sd u cer * pla n L en d p h B 3 t o 4 x h ma x b * Th e t r an s du c er m u s t b e ab o v e t h e m ax i m u m h ead b y at l eas t t h e b l an k i n g v al u e, P47. 7ML 19985A B 01 OCM III 63 ...

  • Siemens 7ML19985AB01 - page 63

    BS-3680 U-Flume, P3 = 4 ‘U’ parameters required * ‘U’ parameters calculated ** U0 = a pproach diameter Da U4 = Cv U1 = thro at di amete r D U5 = Cd U2 = h ump height p U6 = Cu U3 = th roat length L U7 = A * obta in from ma nufa cture r’s spe cifica tions. ** ca lcula te d by OC M - 3 . M a y be vie we d by a cce ssing ‘U ’ pa ra me te ...

  • Siemens 7ML19985AB01 - page 64

    BS-3680 U-FLUME L p h D 3 t o 4 x h ma x Da t r an sd u cer * 0 h ead * Th e t r an s d u c er m u s t b e ab o v e t h e m ax i m u m h ead b y at l eas t t h e b l an k i n g v alu e, P47. 7ML 19985A B 01 OCM III 65 ...

  • Siemens 7ML19985AB01 - page 65

    BS-3680 FINITE CREST WEIR, P 3 = 5 ‘U’ parameters required * ‘U’ parameters calculated ** U0 = cre st widt h b U3 = C U1 = cre st he ight p U4 = Cp U2 = c rest length L * obta in from ma nufa cture r’s spe cifica tions. ** ca lcula te d by OC M - 3 . M a y be vie we d by a cce ssing ‘U ’ pa ra me te r. Reference A B SOL UTE CA L CUL A ...

  • Siemens 7ML19985AB01 - page 66

    BS-3680 FINITE CREST WEIR t r an sd u cer * 3 t o 4 x h ma x * Th e t r an s d u c er m u s t b e ab o v e t h e m ax i m u m h ead b y at l eas t t h e b l an k i n g v alu e, P47. 7ML 19985A B 01 OCM III 67 ...

  • Siemens 7ML19985AB01 - page 67

    BS-3680 THIN PLATE RECTANGULAR WEIR, P3 = 6 ‘U’ parameters required * ‘U’ parameters calculated ** U0 = a pproach wi dth B U3 = Ce U1 = cre st widt h b U4 = K b U2 = cre st he ight p * obta in from ma nufa cture r’s spe cifica tions. ** ca lcula te d by OC M - 3 . M a y be vie we d by a cce ssing ‘U ’ pa ra me te r. Reference A B SOL ...

  • Siemens 7ML19985AB01 - page 68

    BS-3680 THIN PLATE RECTANGULAR WEIR 4 t o 5 x h ma x t r an sd u cer * * Th e t r an s d u c er m u s t b e ab o v e t h e m ax i m u m h ead b y at l eas t t h e b l an k i n g v alu e, P47. 7ML 19985A B 01 OCM III 69 ...

  • Siemens 7ML19985AB01 - page 69

    BS-3680 THIN PLATE V-NOTCH WE IR, P3 = 7 ‘U’ parameters required * ‘U’ parameters calculated ** U0 = n otch angl e alpha U1 = Ce * obta in from ma nufa cture r’s spe cifica tions. ** ca lcula te d by OC M - 3 . M a y be vie we d by a cce ssing ‘U ’ pa ra me te r. Reference A B SOL UTE CA L CUL ATION, P4 = 0 ¤ F or f lows tha t ca n b ...

  • Siemens 7ML19985AB01 - page 70

    BS-3680 THIN PLAT E V-NOTCH WEIR t r an sd u cer * 4 t o 5 x h ma x * Th e t r an s du c er m u s t b e ab o v e t h e m ax i m u m h ead b y at l eas t t h e b l an k i n g v al u e, P47. 7ML 19985A B 01 OCM III 71 ...

  • Siemens 7ML19985AB01 - page 71

    RECTANGULAR WEIR (CONTRACT E D), P3 = 8 ‘U’ parameters required * U0 = cr est width b * obta in from ma nufa cture r’s spe cifica tions. ** ca lcula te d by OC M - 3 . M a y be vie we d by a cce ssing ‘U ’ pa ra me te r. Reference A B SOL UTE CA L CUL ATION, P4 = 0 ¤ F or f lows tha t ca n be ca lcula te d by the e qua tion: q = K x (b - ...

  • Siemens 7ML19985AB01 - page 72

    RECTANGULAR WEIR - CONTRACTED t r an sd u cer * 4 t o 5 x h ma x * Th e t r an s du c er m u s t b e ab o v e t h e m ax i m u m h ead b y at l eas t t h e b l an k i n g v al u e, P47. 7ML 19985A B 01 OCM III 73 ...

  • Siemens 7ML19985AB01 - page 73

    ROUND PIPE, P3 = 9 ( ba se d on the M a nning F ormula ) ‘U’ parameters required * U0 = pipe insid e diam ete r D U1 = s lope (fall/ru n) s U2 = roughn ess coeffi cient n * obta in from ma nufa cture r’s spe cifica tions. Reference A B SOL UTE CA L CUL ATION, P4 = 0 ¤ F or f lows tha t ca n be ca lcula te d by the e qua tion: q = K/ n x f( h ...

  • Siemens 7ML19985AB01 - page 74

    ROUND PIPE h t r an sd u cer * ** * T his dime nsion should be a t le a st 1 5 cm ( 6 " ) shorte r t ha n t h e b l an k in g v alu e, P47. ** Th e t r an s du c er m u s t b e ab o v e t h e m ax i m u m h ead b y at l eas t t h e b l an k i ng v al u e, P47. 7ML 19985A B 01 OCM III 75 ...

  • Siemens 7ML19985AB01 - page 75

    PALM ER-BOWLUS FLUME *, P3 = 10 ‘U’ parameters required ** U0 = maxi mum flu me width , h max * typica lly those ma nufa cture d by W a rminste r or P l a sti- F a b. ** obta in from ma nufa ct ure r’s spe cifica tions. Reference RA TIOMETRIC CA L CUL AT ION, P4 = 1 ¤ F or f lows tha t ca n be ca lcula te d by the e qua tion: q = q ca l x f( ...

  • Siemens 7ML19985AB01 - page 76

    PALMER-BOWLUS FLUM E D = pipe or se we r dia me te r 0 h ead D / 2 , point of me a sure me nt * t ran sd u cer ** * f or ra te d f lows unde r fre e flow conditions ** Th e t r an s du c er m u s t b e ab o v e t h e m ax i m u m h ead b y at l eas t t h e b l an k i ng v al u e, P47. 7ML 19985A B 01 OCM III 77 ...

  • Siemens 7ML19985AB01 - page 77

    H-FLUME *, P3 = 11 ‘U’ parameters required * U0 = maxi mum li sted he ad, h max * a s de ve lope d by the U . S . D e pa rtme nt of Agri culture , S oil C onse rva tion S e rvice . ** obta in from ma nufa ct ure r’s spe cifica tions. Reference RA TIOMETRIC CA L CUL AT ION, P4 = 1 ¤ F or f lows tha t ca n be ca lcula te d by the e qua tion: q ...

  • Siemens 7ML19985AB01 - page 78

    H-FLUME front point of me a sure me nt side t r an sd u cer * pla n Fl u me Si ze Po i n t o f Measu r emen t D ( fe e t) cm inche s 0.5 4.7 1.88 0.75 6.7 2.69 1.0 9.1 3.63 1.5 13.5 5.38 2.0 17.9 7.19 2.5 22.5 9.00 3.0 27.2 10.88 4.5 40.5 16.19 F or ra te d flows unde r fre e flow conditions, th e he a d is me a sure d a t a point downstre a m fro ...

  • Siemens 7ML19985AB01 - page 79

    UNIVERSAL HEAD vs FLOW, P3 = 12 Th e f l ow c u r v e i s c h ar ac ter i zed b y en t er i n g t h e h ead (A eve n ) a nd flow ( A odd ) ordina te s for the numbe r of da ta points ( n, 4 to 1 6 ) ove r the flow ra nge . T he first point ( A0 , A1 ) ge ne ra lly be ing a t 0 he a d a nd the la st point ( A 2n-2 ,A 2n -1 ) ge ne ra lly be ing at m ...

  • Siemens 7ML19985AB01 - page 80

    UNIVERSAL HEAD vs FLOW e . g. typica l compound we ir P a ra me te rs U 0 = 11 A 0 = 0 h ead , p o i nt 1 A 12 = 1. 05 h ead , p o i nt 7 A1 = 0 flow, point 1 A1 3 = 2 . 6 5 f low, point 7 A 2 = 0. 3 head , p o i n t 2 A 14 = 1.2 h ead , po i nt 8 A3 = 0 . 1 flow, point 2 A1 5 = 3 . 4 flow, point 8 A 4 = 0. 6 head , p o i n t 3 A 16 = 1.4 h ead , p ...

  • Siemens 7ML19985AB01 - page 81

    RECTANGULAR AREA X VELOCITY, P3 = 13 ‘U’ parameters required * ‘U’ parameters calculated ** U0 = chan nel wid th B U1 = are a (h) * obta in from ma nufa cture r’s spe cifica tions. ** ca lcula te d by OC M - 3 . M a y be vie we d by a cce ssing ‘U ’ pa ra me te r. Reference A B SOL UTE CA L CUL ATION, P4 = 0 ¤ F or f lows tha t ca n ...

  • Siemens 7ML19985AB01 - page 82

    RECTANGULAR AREA X VELOCI TY t r an sd u cer * * Th e t r an s du c er m u s t b e ab o v e t h e m ax i m u m h ead b y at l eas t t h e b l an k i n g v al u e, P47. 7ML 19985A B 01 OCM III 83 ...

  • Siemens 7ML19985AB01 - page 83

    TRAPEZOIDAL AREA X VELOCITY , P3 = 14 ‘U’ parameters required * ‘U’ parameters calculated ** U0 = chan nel top width B U3 = area (h) U1 = chan nel ba se width b U2 = chan nel de pth ht * obta in from ma nufa cture r’s spe cifica tions. ** ca lcula te d by OC M - 3 . M a y be vie we d by a cce ssing ‘U ’ pa ra me te r. Reference A B SO ...

  • Siemens 7ML19985AB01 - page 84

    TRAPEZOIDAL AREA X VEL OCITY t r an sd u cer * * Th e t r an s d u c er m u s t b e ab o v e t h e m ax i m u m h ead b y at l eas t t h e b l an k i n g v alu e, P47. 7ML 19985A B 01 OCM III 85 ...

  • Siemens 7ML19985AB01 - page 85

    MODIFIED TRAPEZOIDAL AREA X VELOCITY, P3 = 15 ‘U’ parameters listed * ‘U’ parameters calculated ** U0 = chan nel top width B U3 = area (h) U1 = chan nel ba se width b U2 = tr ansit ion he ight ht * obta in from ma nufa cture r’s spe cifica tions. ** ca lcula te d by OC M - 3 . M a y be vie we d by a cce ssing ‘U ’ pa ra me te r. Refer ...

  • Siemens 7ML19985AB01 - page 86

    MODIFIED TRAPEZOIDAL AREA X VELOCITY t r an sd u cer * * Th e t r an s du c er m u s t b e ab o v e t h e m ax i m u m h ead b y at l eas t t h e b l an k i n g v al u e, P47. 7ML 19985A B 01 OCM III 87 ...

  • Siemens 7ML19985AB01 - page 87

    U-CHANNEL AREA X VELOCITY, P3 = 16 ‘U’ parameters required * ‘U’ parameters calculated ** U0 = base diame ter D U1 = are a (h) * obta in from ma nufa cture r’s spe cifica tions. ** ca lcula te d by OC M - 3 . M a y be vie we d by a cce ssing ‘U ’ pa ra me te r. 7ML 19985A B 01 OCM III 88 ...

  • Siemens 7ML19985AB01 - page 88

    U-CHANNEL AREA x VELOCI TY t r an sd u cer * * Th e t r an s du c er m u s t b e ab o v e t h e m ax i m u m h ead b y at l eas t t h e b l an k i n g v al u e, P47. 7ML 19985A B 01 OCM III 89 ...

  • Siemens 7ML19985AB01 - page 89

    CIRCULAR AREA X VELOCITY, P3 = 17 ‘U’ parameters listed * ‘U’ parameters calculated ** U0 = cond uit diame ter ID U1 = are a (h) * obta in from ma nufa cture r’s spe cifica tions. ** ca lcula te d by OC M - 3 . M a y be vie we d by a cce ssing ‘U ’ pa ra me te r. 7ML 19985A B 01 OCM III 90 ...

  • Siemens 7ML19985AB01 - page 90

    CIRCULAR AREA X VELOCITY h t r an sd uc er * ** * T his dime nsion should be a t le a st 1 5 cm ( 6 " ) shorte r t ha n t h e b l an k in g v alu e, P47. ** Th e t r an s du c er m u s t b e ab o v e t h e m ax i m u m h ead b y at l eas t t h e b l an k i ng v al u e, P47. 7ML 19985A B 01 OCM III 91 ...

  • Siemens 7ML19985AB01 - page 91

    GULL-WING AREA X VELOCITY, P3 = 18 ‘U’ parameters required * ‘U’ parameters calculated ** U0 = chan nel ba se width b U4 = are a (h) U1 = lower angle alph a ( α) U2 = uppe r ang le beta ( β) U3 = tr ansit ion he ight ht * obta in from ma nufa cture r’s spe cifica tions. ** ca lcula te d by OC M - 3 . M a y be vie we d by a cce ssing ‘ ...

  • Siemens 7ML19985AB01 - page 92

    GULL WING AREA X VELOCITY t r an sd u cer * V * Th e t r an s du c er m u s t b e ab o v e t h e m ax i m u m h ead b y at l eas t t h e b l an k i n g v al u e, P47. 7ML 19985A B 01 OCM III 93 ...

  • Siemens 7ML19985AB01 - page 93

    EGG-SHAPED AREA X VELOCITY, P3 = 19 ‘U’ parameters listed * ‘U’ parameters calculated ** U0 = top radius R U3 = are a (h) U1 = bot tom radius r U2 = axia l disp lace ment d * obta in from ma nufa cture r’s spe cifica tions. ** ca lcula te d by OC M - 3 . M a y be vie we d by a cce ssing ‘U ’ pa ra me te r. Reference A B SOL UTE CA L C ...

  • Siemens 7ML19985AB01 - page 94

    EGG-SHAPED AREA X VELOCITY t r an sd u cer * sta ndpipe * * * T his dime nsion should be a t le a st 1 5 cm ( 6 " ) shorte r t ha n t h e b l an k in g v alu e, P47. ** Th e t r an s du c er m u s t b e ab o v e t h e m ax i m u m h ead b y at l eas t t h e b l an k i ng v al u e, P47. 7ML 19985A B 01 OCM III 95 ...

  • Siemens 7ML19985AB01 - page 95

    UNIVERSAL AREA X VELOCITY, P3 = 20 A r b it r ary ar ea i s t y p i c all y u s ed w h en t he p r i mar y el em en t an d /o r i t s f lo w d o n o t f i t an y o f t h e p r im ar y el em en t s c o v ered b y P3. Th er e i s n o u s er d i f f er en c e b et w een ab s ol u te a nd ra tiome t ric ca lcula tions P4 . Th e f l ow c u r v e i s c h ...

  • Siemens 7ML19985AB01 - page 96

    UNIVERSAL AREA X VELOCITY U0 = 8 A0 = 0 he a d, point 1 A 1 = 0. 0 area, p o i n t 1 A 2 = 0. 05 h ead , po i n t 2 A 3 = 0. 03 ar ea, po i n t 2 A 4 = 0. 1 head , p o i n t 3 A 5 = 0. 06 ar ea, po i n t 3 A 6 = 0. 15 h ead , po i n t 4 A 7 = 0. 09 ar ea, po i n t 4 A 8 = 0. 25 h ead , po i n t 5 A 9 = 0. 18 ar ea, po i n t 5 A 10 = 0. 45 h ead , p ...

  • Siemens 7ML19985AB01 - page 97

    7ML 19985A B 01 OCM III 98 ...

  • Siemens 7ML19985AB01 - page 98

    MAINTENANCE T h e O C M - 3 re quire s ve ry l ittle ma inte na nce due to its sol id- st a te circuitry. H owe ve r, a progra m of pe riodic pre ve nta t ive ma inte na nc e should be initia te d. T his should include re gul a r inspe ction, ge ne ra l cle a ning, ove ra ll syste m pe rforma nce che cks a nd sta nda rd good house ke e ping pra cti ...

  • Siemens 7ML19985AB01 - page 99

    ERROR CODES Error Code Listing 1 numbe r unde rflow 2 numbe r ove rflow 3 d i v id e er r o r 4 b ad ar g u m en t 5 inva lid pa ra me te r 6 syste m is locke d 7 h ead ex c eed s B S-3680 s pec 8 must use ra tiome tric 9 inva lid a ngle siz e 1 0 inva lid se le ct ion 11 v al u e i s v i ew -o n l y 12 c h ar ac t er i zer i n u s e 13 f eat u r e ...

  • Siemens 7ML19985AB01 - page 100

    COMMUNICATIONS T he O C M - 3 provide s se ria l communica tion e i the r through M illtronics proprie ta ry bipola r curre nt loop or indust ry sta nda rd R S - 232. Co m m u n i c at i o n c a n b e u s ed t o provide a vide o or pa pe r printout of O C M a ctivity. I t ca n a lso be use d to provide re mo te progra mming a nd re trie va l of the ...

  • Siemens 7ML19985AB01 - page 101

    M illtronics provide s a sta nda rd U tilitie s softwa re pa cka ge , for conve nie nt communica tion be twe e n a n I BM P C compa tible compute r a nd t he O C M - 3 . I n a ddition, the use r ma y opt to de ve lop his own custom softwa re progra m to pe rform ta sks suite d to his spe cific ne e ds. Prot oco l T he protocol for the O C M - 3 is ...

  • Siemens 7ML19985AB01 - page 102

    Interconnect ion Bipolar Current RS-232 I BM P C C ompute r C onne ction re fe r to C V C C instruction ma nua l for conne ction to compute r compute r se ria l port D B- 9 conne ctor compute r se ria l port D B- 2 5 conne ctor 1 23456 7 CVCC TB1 + - - C O M M O N T R A N S M I T R E C E I V E + S H E I L D T X D T X D S H L D + - S H L D 1 2 3 4 5 ...

  • Siemens 7ML19985AB01 - page 103

    Timed Prin t Out T he O C M - 3 ca n be progra mme d to pe riodica lly print out O C M da ta ( P 3 4 / 3 5 ) . A typica l print out will have the following forma t. T ime hh:mm:ss D a te dd/ mm/ yy Si te Nu mb er # Head # u n it s Vel o c i ty * # units T e mpe ra ture # units F low R a te # units F low T ota l # units * only for a pplica tions usi ...

  • Siemens 7ML19985AB01 - page 104

    Milltronics Utilities Software Disk T he M illtronics U tilitie s S oftwa re e xpa nds t he hum a n inte rfa ce ca pa bilitie s of the OCM-3 as c om p ar ed t o th at p r o v i d ed b y t h e s i m p l e u s e of t h e i n f r a-r ed p r o g r am m er . U tilitie s S oftwa re P rogra mme r - re mote O C M - 3 progra mming - loca l progra mming - re ...

  • Siemens 7ML19985AB01 - page 105

    T he O C M - 3 U tilitie s softwa re provide d by M illtronics use s X O N / X O F F to e nsure communica tion re lia bility. T he softwa re is writte n to be e xe cute d on a n I BM P C compa tible comput e r. Th e s tan d ar d k ey bo ar d em u l at es t h e OCM-3 p r o g r am m er . Pr es s in g t h e k ey s corre sponding to those displa ye d o ...

  • Siemens 7ML19985AB01 - page 106

    Custom Pr ogramming and Third Party Co mmunication Prog ram Us ers w h o w i s h t o w r i t e t hei r o w n s o f t w ar e to c o m m un i c at e w i t h th e OCM-3 ar e u r g ed to imple me nt a fully buffe re d ( inte rrupt drive n) se ria l link incorpora ting X O N / X O F F . S ome use rs howe ve r, will not ha ve the ca pa city for such a n ...

  • Siemens 7ML19985AB01 - page 107

    T he following is a list of comma nds for the se conda ry pa rse r: C omma nd R e sponse /a#/ t he c o n t en t o f a#, w h er e: a = A , D * , F, P an d U # = 0 through 9 e.g . /P5/ t h e c o n t ent o f P5 * D pa ra me te rs a re the only pa ra me te rs which ma y be a lte re d through the se conda ry comm a nd pa rse r ( w hich bypa sse s the se ...

  • Siemens 7ML19985AB01 - page 108

    / j/ re turns a code indica ti ng the re la y sta tus code re la y 123 0000 1100 2010 3110 4001 5101 6011 7111 /l / s t ar t d at a l o g d o w n l o ad . / l1 . dd. mm. yyyy/ da t a l og down loa d - sta rt da te / l2 . dd. mm . yyyy/ da t a log down loa d - e nd da te / l3 / stop data log down loa d 7ML 19985A B 01 OCM III 109 ...

  • Siemens 7ML19985AB01 - page 109

    Modem Communicat ion C ommunica tion with the O C M - 3 ove r a n a nswe r ba ck te le phone mode m is re la tive ly stra ight forwa rd. F or mode m communica tion ove r conve ntiona l te le phone line s, a m ax i mu m of 1200 o r 2400 b au d i s r ec o m m en d ed . Gen er all y , a l o w er bau d r ate i s more re lia b le on noisy line s. M ode ...

  • Siemens 7ML19985AB01 - page 110

    Considerations - s et t h e ’ c o l d s tar t ’ (F12) d ef au l t b aud t o 1200 b y r em o v in g j u m p er J 1 o n b o ar d A . - s et b o t h m o d em s an d t h e OCM-3 b au d r at es to 1200. - se t the re mote mode m to ope ra te in the ’a nswe r ba ck’ mode . R e f e r t o mode m’s use r ma nua l. Communication - se le ct se ria l ...

  • Siemens 7ML19985AB01 - page 111

    Endi ng Co mmunic ati on - t y pe W to bre a k O C M - 3 communica tion with the mode m * . Th e c o mp u t er s c reen will display a fla shing me ssa ge ‘O C M - 3 mute d’. - t y pe: +++ ( not displa ye d on the scre e n) a nd the n pre ss E N T E R T his will ca use both mode ms to switch t o the ‘comma nd’ mode . T he loca l mode m se n ...

  • Siemens 7ML19985AB01 - page 112

    *7ml19985AB01* Rev . 1.0 www .siemens.com/processautomation Siemens Milltronics Process Instruments Inc. 1 954 T ec hnology Drive, P .O. Box 4225 Peterborough, ON, Canada K9J 7B1 T el: (705) 7 45-2431 Fax: (705) 7 41-0466 Email: techpubs.smpi@siemens.com Siemens Milltronics Process Instruments Inc. 2005 Subject to c hange without prior notice Print ...

Manufacturer Siemens Category Printer Accessories

Documents that we receive from a manufacturer of a Siemens 7ML19985AB01 can be divided into several groups. They are, among others:
- Siemens technical drawings
- 7ML19985AB01 manuals
- Siemens product data sheets
- information booklets
- or energy labels Siemens 7ML19985AB01
All of them are important, but the most important information from the point of view of use of the device are in the user manual Siemens 7ML19985AB01.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Siemens 7ML19985AB01, service manual, brief instructions and user manuals Siemens 7ML19985AB01. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Siemens 7ML19985AB01.

Similar manuals

A complete manual for the device Siemens 7ML19985AB01, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Siemens 7ML19985AB01 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Siemens 7ML19985AB01.

A complete Siemens manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Siemens 7ML19985AB01 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Siemens 7ML19985AB01, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Siemens 7ML19985AB01, that we can find in the current document
3. Tips how to use the basic functions of the device Siemens 7ML19985AB01 - which should help us in our first steps of using Siemens 7ML19985AB01
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Siemens 7ML19985AB01
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Siemens 7ML19985AB01 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Siemens 7ML19985AB01?

Use the form below

If you did not solve your problem by using a manual Siemens 7ML19985AB01, ask a question using the form below. If a user had a similar problem with Siemens 7ML19985AB01 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)