  • Enterasys Networks CM Version 1.0 - page 1

    Enterasys Matrix ™ X Router DC Power Supply P/N 9034200 Installation Guide ...

  • Enterasys Networks CM Version 1.0 - page 2

    ...

  • Enterasys Networks CM Version 1.0 - page 3

    i Notice Enterasys Networks  reserv es  the  right  to  make  changes  in  specifications  and  other  information  contained  in  th is  document  and  its  web  site  without  prior  notice.  The  reader  should  in  all  cases  consult  Enterasys Netw orks ...

  • Enterasys Networks CM Version 1.0 - page 4

    ii Regulatory Compliance Information Federal Communications Commission (FCC) Notice This  device  com plies  with  Pa r t  15  of  the  FC C  rules.  Operation  is  subject  to  the  following  tw o  conditions:  (1)  this  device  may  not  cause  harmful  interference,  ...

  • Enterasys Networks CM Version 1.0 - page 5

    iii Electromagnetic Compatibility (EMC) This  product  complies  with  the  following:  47  CF R  Pa r t s  2  and  15,  CSA  C108.8,  2006/95/EC,  EN  55022,  EN  61000 ‐ 3 ‐ 2,  EN 61000 ‐ 3 ‐ 3,  EN  55024,  AS/NZS  CISPR  22,  VCCI  V ‐ 3.  Compatibilidad ...

  • Enterasys Networks CM Version 1.0 - page 6

    iv ѻ ѻ ક䇈ᯢк䰘ӊ Supplement to Product Instructions ᳝↦᳝ᆇ⠽䋼៪ܗ㋴ (Hazardous Substance) 䚼ӊৡ⿄ (Parts) 䪙 3E ∲ +J 䬝 &G ݁Ӌ䫀 &U   ໮⒈㘨㣃 3%% ໮⒈Ѡ㣃䝮 3%'( 䞥ሲ䚼ӊ (Metal Parts) hƻ ƻ h ƻ ƻ ⬉䏃῵ഫ ( Circuit ...

  • Enterasys Networks CM Version 1.0 - page 7

    v VCCI Notice This  is  a  class  A  product  based  on  the  standard  of  the  Vo l u n t a r y  Control  Coun cil  for  Interference  by  Information  Te c h n o l o g y  Equipment  (VCCI).  If  this  equipmen t  is  used  in  a  dom estic  environme nt, ? ...

  • Enterasys Networks CM Version 1.0 - page 8

    vi Declaration of Conformity Application  of  Co uncil  Directiv e(s): 2004/108/EC 2006/95/EC Manufacturer ’ s  Name: Enterasys Networks, Inc. Manufacturer ’ s  Address: 50  Minuteman  Road Andover ,  MA  01810 USA European  Representativ e  Address: Enterasys Networks,  Ltd. Nexus  House,  Newbury  ...

  • Enterasys Networks CM Version 1.0 - page 9

    vii Enterasys Networks, Inc. Fi rmware License Agreement BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT. This  document  is  an  agreement  (“ Agreement”)  betwee n  the  end  user  (“Y ou”)  and  Enterasys  Networks,  In c.,  on  behalf  of  itse ...

  • Enterasys Networks CM Version 1.0 - page 10

    viii 4. EXPORT  RESTRICTIONS. You  understand  that  Entera sys  and  its  Affiliates  are  subject  to  regulation  by  agencies  of  the  U.S.  Government,  including  the  U. S.  Department  of  Commerce,  which  prohibit  ex port  or  diversion  of  certai ...

  • Enterasys Networks CM Version 1.0 - page 11

    ix 8. AUDIT  RIGHTS. You  here by  acknow ledge  that  the  intellectual  property  rights  associated  with  the  Prog ram  are  of  critical  value  to  Enterasys,  and,  accordingly,  You  hereby  agree  to  maintain  complete  books,  re cords  and  accoun ...

  • Enterasys Networks CM Version 1.0 - page 12

    x ...

  • Enterasys Networks CM Version 1.0 - page 13

    xi Contents Chapter 1: DC Power Supply Installation Overview of the DC Power Supply .. ................ ................ ............. ................. ................ ............... .... .. 1-2 Power Supply Redundancy Planning .............. ................ ................ ................ ................ ............ 1-4 Installation Site R ...

  • Enterasys Networks CM Version 1.0 - page 14

    xii ...

  • Enterasys Networks CM Version 1.0 - page 15

    Matrix X Router DC Power Supply Installation Guide xiii About This Guide This  guide  describes  the  Enterasys  Matrix ™  X  Router  DC  power  supply  features  and  specifications,  and  provides  information  to  install  the  power  supply  in  an  Enterasys  Matrix? ...

  • Enterasys Networks CM Version 1.0 - page 16

    Conventions Used in This Guide xiv About This Guide Documentation  can  be  accessed  on  the  Wo r l d  Wide  We b ,  at  the  following  URL: http://www .enterasys.c om/support/manuals/ Conventions Used in This Guide The  following  conventions  are  used  in  this  guide: Note: Calls the r ...

  • Enterasys Networks CM Version 1.0 - page 17

    Getting Help Matrix X Router DC Power Supply Installation Guide xv Getting Help For  additional  support  related  to  the  DC  pow er  supply  or  this  document,  contact  Enterasys Networks  using  one  of  the  foll owing  methods: Before  contacting  Enterasys Networks  for  ...

  • Enterasys Networks CM Version 1.0 - page 18

    Getting Help xvi About This Guide ...

  • Enterasys Networks CM Version 1.0 - page 19

    Matrix X Router DC Power Supply Installation Guide 1-1 1 DC Power Supply Installation This  chapter  provides  installation  instructions  for  the  Enterasys  Matrix™  X  Router  DC  power  supply  module  (X ‐ DC ).  Follow  the  order  of  the  sections  listed  below  t ...

  • Enterasys Networks CM Version 1.0 - page 20

    Overview of the DC Power Supply 1-2 DC Power Supply Installation Overview of the DC Power Supply The  DC  power  suppl y  (X ‐ DC)  can  be  used  in  the  Enterasy s  Matrix™  X16 ‐ C,  X8 ‐ C,  and  X4 ‐ C  chassis  in  place  of  the  standard  AC  power  supplies ...

  • Enterasys Networks CM Version 1.0 - page 21

    Overview of the DC Power Supply Matrix X Router DC Power Supply Installation Guide 1-3 Figure 1-2 Back V iew of the DC Power Supply The  DC  power  suppl y  provides  the  following  features: •I n p u t  Overload  Protection As  shown  in  Figure 1 ‐ 1  on  page 1 ‐ 2,  the  pow er  supply ? ...

  • Enterasys Networks CM Version 1.0 - page 22

    Installation Site Requirements 1-4 DC Power Supply Installation Power Supply Redundancy Planning Because  chassis  syste m  components  consume  va r yi n g  amounts  of  electrical  power ,  Enterasys  recommend  consulting  the  module  pow er  specifications  in  “ Powe r  Supply  Red ...

  • Enterasys Networks CM Version 1.0 - page 23

    Pre-Installation Tasks Matrix X Router DC Power Supply Installation Guide 1-5 Pre-Inst allation T asks Complete  the  followin g  tasks  before  installing  the  DC  power  supply: • Ve r i f y  DC  Po w e r  Compliance  of  Matrix  X  Modules • Prepare  Site  Wir i n g  for  DC  Po ...

  • Enterasys Networks CM Version 1.0 - page 24

    Pre-Installation Tasks 1-6 DC Power Supply Installation 2. Use  the  information  from  the  output  of  the  show system hardware  command  to  fill  out  the  worksheet  in  Ta b l e 1 ‐ 1  for  each  module  as  follows: a. Use  the  val u e  of  “940  Pa r t  n ...

  • Enterasys Networks CM Version 1.0 - page 25

    Pre-Installation Tasks Matrix X Router DC Power Supply Installation Guide 1-7 New DC Power Matrix X System Inst allations If  the  system  is  a  new  Matrix  X  DC ‐ pow ered  installation,  fol low  this  procedure  to  ve ri fy  DC  power  compliance  of  all  modules: 1. Obtain  t ...

  • Enterasys Networks CM Version 1.0 - page 26

    Pre-Installation Tasks 1-8 DC Power Supply Installation Prep are Site Wiring fo r DC Power Inst allation 1. Ensure  that  a  branch  circuit  disconnect  device  is  installed,  and  that  the  device  is  switched  to  prevent  pow er  from  being  supplied  to  the  DC  pow e ...

  • Enterasys Networks CM Version 1.0 - page 27

    Unpacking the DC Power Supply Matrix X Router DC Power Supply Installation Guide 1-9 Unp acking the DC Power Supply To  unpack  the  DC  power  supply: 1. Open  the  box  and  remov e  the  packing  material  protecting  the  DC  power  supply. 2. V erify  the  contents  of  the  car ...

  • Enterasys Networks CM Version 1.0 - page 28

    Installing the DC Power Supply 1-10 DC Power Supply Installation 3. Remove  the  tape  seal  on  the  non ‐ conductiv e  bag  to  remov e  the  module. 4. P erform  a  visual  inspection  of  the  power  supply  and  cable  harness  for  any  signs  of  physical  dam ...

  • Enterasys Networks CM Version 1.0 - page 29

    Installing the DC Power Supply Matrix X Router DC Power Supply Installation Guide 1-11 2. Remove  the  vent  plate  covering  all  powe r  supply  slots  by  loosening  the  top  and  bottom  captive  screws,  as  shown  in  Figure 1 ‐ 3 . Figure 1-3 Removing Powe r Supply V ent Plate 3. ...

  • Enterasys Networks CM Version 1.0 - page 30

    Installing the DC Power Supply 1-12 DC Power Supply Installation 5. Hold  the  power  supply  by  placing  one  ha nd  on  the  handle  located  on  the  front  panel  and  using  you r  other  hand  to  support  the  power  supply . 6. P osition  the  power  supply ...

  • Enterasys Networks CM Version 1.0 - page 31

    Installing the DC Power Supply Matrix X Router DC Power Supply Installation Guide 1-13 Figure 1-5 Removin g Blank Co verplate from Power Supply Slot 10. Connect  the  chassis  to  earth  ground  utilizing  the  earth  ground  connection  on  the  back  of  the  unit. a. Cut  an  8  AW G  ( ...

  • Enterasys Networks CM Version 1.0 - page 32

    Removing a Power Supply 1-14 DC Power Supply Installation b. Place  the  lock  wa s h e r s  over  the  positive  and  negative  studs. c. Place  the  nuts  ov er  the  lock  was h e r s  and  tighten.  To r q u e  applied  must  be  36 in ‐ lb. 13. Replace  the  plastic  ...

  • Enterasys Networks CM Version 1.0 - page 33

    Removing a Power Supply Matrix X Router DC Power Supply Installation Guide 1-15 Caution: If you want to operate the chassis with only one power supply , be sure to install the coverplate in place of the removed power supply to contain EMI radiation and ensure proper air circulation. Precaución: Si desea trabaja r sólo con una fuente de poder , no ...

  • Enterasys Networks CM Version 1.0 - page 34

    Removing a Power Supply 1-16 DC Power Supply Installation ...

  • Enterasys Networks CM Version 1.0 - page 35

    Matrix X Router DC Power Supply Installation Guide 2-1 2 DC Power Supply Specifications This  chapter  provides  the  DC  power  supply  specifications  and  regulatory  complianc e  information. S pecifications Ta b l e 2 ‐ 1  lists  the  physical  specifications.  Ta b l e 2 ‐ 2  lists  th ...

  • Enterasys Networks CM Version 1.0 - page 36

    Power Supply Redundancy 2-2 DC Power Supply Specifications Compression Lugs The  DC  power  supply  positive  and  negative  bolt  patterns  match  up  to  a  1/4 ‐ inch  diame ter ,  2 ‐ hole  compression  lug  spaced  5/8 ‐ inch  on  center .  This  compression  lug  ...

  • Enterasys Networks CM Version 1.0 - page 37

    Power Supply Redundancy Matrix X Router DC Power Supply Installation Guide 2-3 T able 2-3 Modu le Power Spe cifications Module @ 48 VDC Power (W atts) Thermal Output (BTU/HR) CM 97 W atts 331.1 BTU/HR Fan tray 85 W atts 290.1 BTU/HR X4-FM 30 W atts 102.4 BTU/HR X8-FM 62 W atts 21 1.6 BTU/HR X16-FM 98 W atts 334.5 BTU/HR X-G T16-00 155 Watt s 1 1. T ...

  • Enterasys Networks CM Version 1.0 - page 38

    Regulatory Compliance 2-4 DC Power Supply Specifications Regulatory Compliance The  DC  power  suppl y  meets  the  safety  and  electromagnetic  compatibil ity  (EMC)  requirements  listed  in  Ta b l e 2 ‐ 5 : T able 2-5 Complia nce St andards Regulatory Compliance Stan da r ds Safety UL 60950, CSA C22. ...

Manufacturer Enterasys Networks Category Network Router

Documents that we receive from a manufacturer of a Enterasys Networks CM Version 1.0 can be divided into several groups. They are, among others:
- Enterasys Networks technical drawings
- CM Version 1.0 manuals
- Enterasys Networks product data sheets
- information booklets
- or energy labels Enterasys Networks CM Version 1.0
All of them are important, but the most important information from the point of view of use of the device are in the user manual Enterasys Networks CM Version 1.0.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Enterasys Networks CM Version 1.0, service manual, brief instructions and user manuals Enterasys Networks CM Version 1.0. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Enterasys Networks CM Version 1.0.

A complete manual for the device Enterasys Networks CM Version 1.0, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Enterasys Networks CM Version 1.0 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Enterasys Networks CM Version 1.0.

A complete Enterasys Networks manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Enterasys Networks CM Version 1.0 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Enterasys Networks CM Version 1.0, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Enterasys Networks CM Version 1.0, that we can find in the current document
3. Tips how to use the basic functions of the device Enterasys Networks CM Version 1.0 - which should help us in our first steps of using Enterasys Networks CM Version 1.0
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Enterasys Networks CM Version 1.0
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Enterasys Networks CM Version 1.0 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Enterasys Networks CM Version 1.0?

Use the form below

If you did not solve your problem by using a manual Enterasys Networks CM Version 1.0, ask a question using the form below. If a user had a similar problem with Enterasys Networks CM Version 1.0 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)