    2 IMPORTANT SAFETY INSTRUCTIONS WARNING: Do not attempt to service this product yourself except to replace the battery. Opening or removing the cover may expose you to dangerous voltages, even when the AC cord is disconnected from the electrical outlet. Refer all servicing to qualified service personnel. 1. SAVE THESE INSTRUCTIONS. THIS MANUAL CONT ...

  • Liebert GXT - page 3

    3 10. Route power supply cords so they are not walked on or pinched. 11. Never block or insert any object into the ventilation holes or other openings . Maintain a clearance of four (4) inches in front and rear of the UPS for proper air flow and cooling. 12. It is not necessary to turn off the UPS before starting the battery replacement procedure. ...

  • Liebert GXT - page 4

    4 MAJOR COMPONENTS G TVSS and EMI/RFI Filters INPUT Dynamic Bypass Rectifier/PFC Inverter OUTPUT DC to DC Converter Battery Battery Charger TRANSIENT VOLTAGE SURGE SUPPRESSION (TVSS) AND EMI/RFI FILTERS These UPS components provide surge protection, and filter both electromagnetic interference (EMI) and radio frequency interference (RFI). They mini ...

  • Liebert GXT - page 5

    5 BATTERY The UPStation GXT™ employs valve regulated, nonspillable, lead acid batteries. At typical room temperatures and with the UPS float charging, the battery system will last many years . Optional external battery cabinets are available to provide extended run times. For battery run times, refer to the Typical Battery Discharge Curves. DYNAM ...

  • Liebert GXT - page 6

    6 Support Base Rack-Tower models are stabilized by the supplied support bases. See illustration for placement. RACK-MOUNT CONVERSION DIAGRAMS To p Cove r Screw s Flange Screws Aerial Vie w w/top cover remove d Rubber Fee t Lift here t o change orientation o f display template ! + - E D C B A Faul t BYPAS S UPS ON BATTER Y AC INPUT RACK-MOUNT UPS CO ...

  • Liebert GXT - page 7

    7 5. Gently lay unit on its right side and remove the six rubber feet with the screw driver. Remove and retain screws from the two front feet. NOTE: The rubber feet are not used for rack-mount installations. 6. Locate securing flanges in the top of packing material and fasten to the UPS using the flange screws from steps 4 and 5. 7. Remove display ...

  • Liebert GXT - page 8

    8 OPTIONAL BATTERY CABINET(S) INSTALLATION Up to two optional battery cabinets may be connected to the UPS to provide additional run time. Battery cabinets are designed to be placed on either side or beneath the UPS. Unpack the UPS battery cabinet(s) carefully noting the packing method. Retain the box and packing material for possible future shipme ...

  • Liebert GXT - page 9

    9 UPStation GXT™ On/Alarm Silence / Manual Battery Tes t Butto n Off/ Bypass Button Fault Indicator Bypass Indicator UPS On Indicator Battery Indicato r AC Input Indicato r Load/Battery Leve l Indicators 1800 V A Rack Towe r 2700 V A Rack Towe r 1 6 6 2 2 4 4 7 7 5 1- Output Receptacle s 2- DB-9 Interface Por t 3- AC Inlet 4- Intellislot T M Comm ...

  • Liebert GXT - page 10

    10 CONTROLS AND INDICATORS On/Alarm Silence/Manual Battery Test Button This button controls output power to connected load(s) and has three functions: On, Alarm Silence, and Manual Battery Test. Pressing this button will start up the UPS in order to provide conditioned and protected power into the utility socket. To silence alarms, press this butto ...

  • Liebert GXT - page 11

    11 UPS On Indicator (Green) The UPS On indicator is illuminated when the UPS inverter is operating and supplying power to your connected loads. Battery Indicator (Amber) The Battery indicator is illuminated when the UPS is operating from the battery system. AC Input Indicator (Green) The AC Input indicator is illuminated when utility power is avail ...

  • Liebert GXT - page 12

    12 ! Faul t BYPAS S UPS ON BATTER Y AC INPUT 100% 76-100 % 51-75 % 26-50 % 0-25 % Figure 1- Normal Mode Operation at 51-75% loading BATTERY MODE OPERATION Battery mode occurs in event of an extreme input voltage condition or complete utility failure. The battery system supplies power through the DC-DC converter to the inverter to generate power for ...

  • Liebert GXT - page 13

    13 COMMUNICATIONS INTERFACE PORT The UPStation GXT™ UPS contains a standard DB-9 female connector located on the rear of the UPS unit. Several signals are provided on this port and are assigned as follows: PIN ASSIGNMENT DESCRIPTION 1 Low Battery (open collector) 2 UPS TxD (typical RS-232 levels) 3 UPS RxD (typical RS-232 levels) 4 Remote Shutdow ...

  • Liebert GXT - page 14

    14 UPS INTELLIGENT COMMUNICATIONS The UPStation GXT™ UPS has the capability to communicate intelligently with stand alone computers, network workstations, network servers, or UNIX hosts via the DB-9 female connector located at the rear of the UPS. By purchasing the optional Liebert SiteNet® 2 software package (sold separately), intelligent commu ...

  • Liebert GXT - page 15

    15 BATTERY REPLACEMENT PROCEDURES CAUTION – A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed before replacing the batteries: - It is not necessary to turn off and disconnect the UPS from the utility power prior to opening the battery replacement door; however, it is your ...

  • Liebert GXT - page 16

    16 8. Connect the battery wire connectors together. 9. Slide battery assembly completely into the UPS, reposition the large battery door and replace the screws removed in step 3. 10. Reposition small battery door and replace the screws removed in step 2 to lock top battery door closed. 11. Replace front bezel (cover) on UPS. Replace the securing fl ...

  • Liebert GXT - page 17

    17 RACK / TOWER BATTERY REPLACEMENT Large battery doo r Battery connecto r Large battery doo r Screw hidden b y small battery doo r Small battery doo r Two front rubber fee t Front bezel (cover ) Rear Vie w Aerial Vie w w/top cover remove d Flang e screw s Top cove r screws ...

  • Liebert GXT - page 18

    18 UPStation GXT™ BATTERY RUN TIMES (Discharge times are at 25° C ambient) 1800 VA Rack Towe r 2700 VA Rack Towe r ...

  • Liebert GXT - page 19

    19 AUDIBLE ALARM CONDITIONS CONDITION ALARM Battery mode (utility failure) One short beep every ten seconds; more than two minutes of run time remaining Low battery Two short beeps every five seconds; less than two minutes of run time remaining Output overload (bypass) One short beep every half second Over temperature (bypass) One second beep every ...

  • Liebert GXT - page 20

    20 TROUBLESHOOTING GUIDE PROBLEM CAUSE SOLUTION UPS is short circuited or overloaded Ensure UPS is off. Disconnect all loads and ensure nothing is lodged in output sockets. Ensure loads are not defective or shorted internally. UPS fails to start when on button is pressed Internal fuse is blown, indicating internal fault Do not attempt to open or se ...

  • Liebert GXT - page 21

    21 SPECIFICATIONS MODEL NUMBER GXT1800RT-208 GXT2700RT-208 GXT96VBATT MODEL RATING VA/W 1800 / 1290 2700 / 1890 DIMENSIONS: in (mm) Unit W x D x H 7.0 x 19.3 x 16 . 9 (177 x 522 x 430) 7.0 x 19.3 x 16 . 9 (177 x 522 x 430) 7.0 x 19.3 x 16 . 9 (177 x 522 x 430) Shipping W x D x H 13.38 x 26.0 x 22.25 (340 x 660 x 565) 13.38 x 26.0 x 22.25 (340 x 660 ...

  • Liebert GXT - page 22

    22 LIMITED WARRANTY Liebert Corporation extends the following LIMITED WARRANTY to the purchaser and to its customer (collectively referred to as the "Purchaser"): the enclosed Uninterruptible Power System (UPS) and components are free from defects in materials and workmanship under normal use, service, and maintenance FOR A PERIOD OF TWO ...

  • Liebert GXT - page 23

    23 1050 Dearborn Drive Columbus, OH 43229 614-888-0246 Technical Support U.S.A. 1-800-222-5877 Outside the U.S.A. 614-841-6755 U.K. +44 (0) 1793 553355 France +33 1 4 87 51 52 Germany +49 89 99 19 220 Italy +39 2 98250 1 Netherlands +00 31 475 503333 E-mail upstech@liebert.com W eb site http://www.liebert.com W orldwide FAX tech support 614-841-547 ...

Manufacturer Liebert Category Power Supply

Documents that we receive from a manufacturer of a Liebert GXT can be divided into several groups. They are, among others:
- Liebert technical drawings
- GXT manuals
- Liebert product data sheets
- information booklets
- or energy labels Liebert GXT
All of them are important, but the most important information from the point of view of use of the device are in the user manual Liebert GXT.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Liebert GXT, service manual, brief instructions and user manuals Liebert GXT. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Liebert GXT.

A complete manual for the device Liebert GXT, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Liebert GXT by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Liebert GXT.

A complete Liebert manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Liebert GXT - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Liebert GXT, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Liebert GXT, that we can find in the current document
3. Tips how to use the basic functions of the device Liebert GXT - which should help us in our first steps of using Liebert GXT
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Liebert GXT
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Liebert GXT in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Liebert GXT?

Use the form below

If you did not solve your problem by using a manual Liebert GXT, ask a question using the form below. If a user had a similar problem with Liebert GXT it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)