-
MicroNet Technology SP907BB - page 1
User ’ s Manual Wireless LAN USB A dapter Model No.: SP907BB W ebsite:http:/ /www .micronet.inf o ...
-
MicroNet Technology SP907BB - page 2
1 Content 1. Introduct ion................................................................................................................ .................... 2 1.1. Pack age Contents........................................................................................................ 2 1.2. Appearanc e........................................... ...
-
MicroNet Technology SP907BB - page 3
2 1 . I n t r o d u c t i o n Thank you for usi ng Micron et SP907BB. T his installati on guide will help you install S P907BB and connect t o the Internet quick & easy . 1.1. Package Content s 1. Microne t SP907BB W ir eless LAN USB Ada pter 2. Quick Installation G uide 3. Manual & Dr iver CD D isc 4. USB cable 1.2. Appearance 1.3. System ...
-
MicroNet Technology SP907BB - page 4
3 Ad-Hoc M ode Ad-Hoc m ode is a Peer-to- Peer m ode. W ithout an AP , computer s can also connect to each other b y SP907B B. W ith this mode, c omputers are able to share data or conn ect to the Inter net if one of them is alread y connected to. Infrastruc ture Mode Infras tructure m ode including a n AP , unlike Ad-Hoc m ode, enabling users to b ...
-
MicroNet Technology SP907BB - page 5
4 2 . I n s t a l l a t i o n Note: The scr eens showed below are f rom W indows 2000. F or other W indows sys tem, the steps ar e the sam e, but the scr eens sho wn will be a little d ifferent. 1. After pluggi ng SP907B B into your PC, it will autom aticall y find and a lert a New U SB Devic e. Click “Next” to conti nue. 2. Y ou’ll see th e ...
-
MicroNet Technology SP907BB - page 6
5 4. Y our PC will rec ogni ze the devic e of “USB W ireles s LAN Card” , and clic k “Nex t” to install driver . 5. Finall y , click the “Finish” to leav e this dial ogue wind ow . 6. After installat ion, please check whether the installation is succes s. Î St a r t → Sett ing → Contro l Panel Double c lick “System ” → click ...
-
MicroNet Technology SP907BB - page 7
6 3 . S o f t w a r e I n s t a l l a t i o n 1. Insert the “ Manual & Driver CD-RO M” into the CD- ROM driver of your PC, a nd you’l l see the software installat ion windo w as sho wn below . 2. Click “Setup Driver & Utilit y”, and choose t he “def ault” item through th e installatio n proces s. 3. After succ essful ins talla ...
-
MicroNet Technology SP907BB - page 8
7 3.1. Sof tware Util ity 1. Click the icon and t he software ut ilit y window sho ws up. 2. S t atus windo w allows you to chan ge Operati on Mode, Chan nel, SSID, Tx Rate, Int Rom aing, and Rad io. It also s hows th e connectin g signal an d quali ty for you t o adjus t related infras tructures and c onfigur ations. 3. S t atistics window: It sh ...
-
MicroNet Technology SP907BB - page 9
8 current en vironm ent. Double c lick the de vice you want to connec t. 5. Encryption window: SP907 BB is able to provide 64/128Bit encr yption. 6. Advance d windo w: It provides you to adjus t PREA MBLE, Fr agmentation T hreshold, RT S/CTS ...
-
MicroNet Technology SP907BB - page 10
9 Thres hold, and Po wer Save f unction. 7. Profiles window: It pr ovides custom ers to chang e settings and sav e them in the conf iguration file. ...
-
MicroNet Technology SP907BB - page 11
10 8. Info window: It shows the lates t software version and MAC addres s. ...
-
MicroNet Technology SP907BB - page 12
11 4 . A d - H o c ( P e e r t o P e e r ) M o d e S e t u p 4.1. Application 1 Access the Internet without an A P W ith existing Inter net connec tion, anoth er com puter can acc ess the Inter net by u sing Peer t o Peer mode of SP907BB. ? ...
-
MicroNet Technology SP907BB - page 13
12 Setup Steps 1. Check the current en viro nment and i nstall W LAN cards i. Check whether “com puter 1” connec ts to the Inter net. ii. Install USB W ireles s Lan Card in “com puter 1”, and “com puter 2”. 2. “Com puter 1” Setu p i. Click “S tart” (1) -> Sett ings (2) - > Click Network and Di al-up Connec tions (3) ii. Un ...
-
MicroNet Technology SP907BB - page 14
13 iii. Check the status of the Connection icon. Cl ick the Co nnection ic on, and you can s ee the device n ame and s tatus under Net work Connections . The nam e of this W LAN CARD is “ USB W ireles s LAN Card”, and ano ther on e is the origin al connec ted de vice, “Ethernet card 1”. PS: (If you have m ore than 2 c onnectin g devices, p ...
-
MicroNet Technology SP907BB - page 15
14 vi. Double cl ick the W LAN ico n in Icon Tray , and enter int o the “Soft ware and Utilit y win dow ”. Software and Ut ilit y window: vii. Change t o the “Ad-H oc” m ode 1. Under “M onitor window”, c lick “ Change” (1) t o modif y the Operatio n Mode to “ Ad-hoc ” mode ( 2). 2. Change t he SSID nam e to “AN Y” (3), and t ...
-
MicroNet Technology SP907BB - page 16
15 Check wh ether the Setup is su ccess Computer 1: 1. Enter into DO S MODE, a nd type “IPCONFIG” . (S t art -> Run - > T y pe cmd or command) (in W indows 98/me O S System ) 1 ...
-
MicroNet Technology SP907BB - page 17
16 2. Check whether the IP address is 192.168.0. 1, and the Sub net Mask is 255.255.25 5.0 (as sho wn above) Computer 2: 1. IP address does not need to setup. T he DEF AUL T GA T E WA Y is 192.168.0.1. 2. Please f ollow the st eps of “com puter 1” to ch eck whet her the IP address is 192.1 68.0.1 4.2. Application 2 Dat a sharing bet w ee n ...
-
MicroNet Technology SP907BB - page 18
17 5. Appendix 1. Operation Mod e: SP9007B B has t wo modes, ‘Infrastr ucture’ and ‘ Ad-Hoc’. The def ault settin g is “Inf rastruc ture”. (Please r efer to th e Product Introductio n) 2. Channel: The c hannel settin g should f ollow the regu lation of the local go vernm ent. For ‘Infra struc ture’ mode, the channe l does n ot need ...
-
MicroNet Technology SP907BB - page 19
18 10. Fr agmentation Threshold : This configuratio n determ ines whether needs to f ragment t he Fram e during trans m it. W hen fragm ent, if the tra nsmit f ell, com puter only resen t the fail fram e instead of the whole fil e again. W hen the frequenc y band us ed is not cl ear , i.e. The S/N r atio is lo w , tr ansmit is easier to f ail. Unde ...
Do you have a question concerning MicroNet Technology SP907BB?
Use the form below
If you did not solve your problem by using a manual MicroNet Technology SP907BB, ask a question using the form below. If a user had a similar problem with MicroNet Technology SP907BB it is likely that he will want to share the way to solve it.