    ii L OCATIONS C ORPORATE H EADQUARTERS North America Metrologic Instru ments, Inc. Customer Servic e: 1-800-ID-METRO 90 Coles Road Tel: 856-228- 8100 Blackwood, NJ 0801 2-4683 Fax: 856-228-66 73 Email: info@metrologic.com Internet: www .metrologic.com E UROPEAN H EADQUARTERS Germany, Metrolog ic Instruments G mbH Tel: +49 89 890 19 0 Middle East an ...

  • Metrologic MS9524 - page 4

    iii T ABLE OF C ONTENTS Introducti on........................................................................................................... 1 Scanner and A ccessori es ..................................................................................... 2 Operation Test........................................................................... ...

  • Metrologic MS9524 - page 5

    1 I NTRODUCTION The Voyager PDF ™ series of scanners has taken the alr eady proven and reliab le Voyager series to new levels of abilit y. With its introduction, Metrologic’s Voyager PDF ™ series has added the ability to dec ode PDF, a 2D symbology that includes both normal and truncated versi on of this bar code type. This symbology differs ...

  • Metrologic MS9524 - page 6

    2 S CANNER AND A CCESSORIES B ASI C K IT Part # Description MS9524 or MS9544 Voyager PDF Series Scanner 00-02544 MetroSelect Single-Line Programm ing Guide* 00-02990 Supplemental Programming Guide* 00-02989 MS9524/44 Voyager PD F Series Installation and Us er’s Guide* * Available on the Metrologic website - www.metrologic.com O PTIONAL A CCESSORI ...

  • Metrologic MS9524 - page 7

    3 S CANNER AND A CCESSORIES O PTIONAL A CCESSORIES Part # Description 53-53213 USB Power/Communication Cabl e, 3 m (10’) coiled cord, long strain relief, gray 53-53214 USB Power/Communication Cabl e, 5 m (17’) coiled cord, lo ng strain relief, gray MX009-3** MX009 USB Converter Cab le MVC** Metrologic Voltage Converter Cable +12VDC to +5.2VDC o ...

  • Metrologic MS9524 - page 8

    4 Figure 1. Figure 2. Figure 3. O PERATIONAL T EST 1. Connect the 10-pin RJ45 male connector into the jack on the Voyager PD F . You will hear a ‘click’ when the connection is made. 2. Connect the L-shaped plug of the power supply into the power jack on the PowerLink cable. 3. Connect the power supply into an AC outlet. Make sure the AC input r ...

  • Metrologic MS9524 - page 9

    5 I NSTALLING THE S CANNER TO THE H OST S YSTEM MS9524-00/9/11/14/41 and MS9544-00/9/11/14/4 1 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connector into the jack on the Voyager PDF . You will hear a ‘click’ when the connection is made. 3. Connect the L-shaped plug of the power supply into the power jack on the PowerLink cable. ...

  • Metrologic MS9524 - page 10

    6 Figure 5. I NSTALLING THE S CANNER TO THE H OST S YSTEM Keyboard Wedge MS9524-47 and MS9544-47 1. Turn off the PC. 2. Connect the 10-pin RJ45 male connector into the jack on the Voyager PDF . You will hear a ‘click’ when the connection is made. 3. Connect the L-shaped plug of the power supply into the power jack on the PowerLink cable. 4. Mak ...

  • Metrologic MS9524 - page 11

    7 I NSTALLING THE S CANNER T O T HE H OST S YSTEM Stand Alone Keyboard 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connector into the jack on the Voyager PDF . You will hear a ‘click’ when the connection is made. 3. Connect the L-shaped plug of the power supply into the power jack on the PowerLink cable. 4. Make sure the AC inp ...

  • Metrologic MS9524 - page 12

    8 I NSTALLING THE S CANNER TO THE H OST S YSTEM Integrated Full Speed USB MS9524-40 and MS9544-40 1. Turn off the host system. 2. Connect the 10-pin RJ45 male co nnector of the USB cable into the jack on the Voyager PDF . You will hear a ‘click’ when the connection is made. 3. Connect the other end of the USB cable to the host USB port. 4. Turn ...

  • Metrologic MS9524 - page 13

    9 D ISCONNECTING THE P OWER L INK C ABLE Before removing the cable from the sca nner, Metrologic recomme nds that the power on the host system is off and the power supply has been disc onnected from the PowerLink cable. Figure 8. 1. Locate the small ‘pin-hole’ on the t op of the unit near the bottom of the Voyager logo. 2. Bend an ordinary pap ...

  • Metrologic MS9524 - page 14

    10 H OW TO U SE C ODE G ATE – MS9544 T WO M ODES OF O PERATION • Auto trigger activates the laser • Place the laser line on the bar code • Press the CodeGate button to transmit the data 1 2 3 Figure 10. • Auto-triggers while in the stand • Bar code is automatically decoded and transmitted • CodeGate activate s when removed from the st ...

  • Metrologic MS9524 - page 15

    11 H OW TO S CAN PDF B AR C ODES Operator Note: PDF-CodeGate is disabled (by d efault) in all MS9544 Voyager PDF units. 1. The auto trigger activates the laser when the bar code is placed in the scanner's IR range. 2. Position the laser line at the top of the code then sweep the beam over and down to the base of the code. If needed, re-sweep t ...

  • Metrologic MS9524 - page 16

    12 S TAND K ITS Free Standing Kits #46-461 28 a. Stand ( MLPN 36-00454) ............................. Qty 1 b. Apron ( MLPN 50-50440 ) ............................. Qty 1 c. Screw, M3 x 6 mm ( MLPN 18-18670 ) ........ Qty 2 d. Washer, #5 x .5 OD ( MLP N 18-18671) ...... Qty 2 e. Stand Anchor ( MLPN 50-50449) ................ Qty 1 f. M3 x 20 mm Set ...

  • Metrologic MS9524 - page 17

    13 A SSEMBLING THE S T ANDS There are 2 options for assembling the stan d. The first option allows the stand to be self-supporting and moved freel y or placed anywhere on the counterto p. The second option is used if the stand will be bolted/hard-mounted to the countertop. Stand Option 1: Se lf-supported For use with kit #46-46128 Step 1 Slide the ...

  • Metrologic MS9524 - page 18

    14 A SSEMBLING THE S T AND (C ONTINUED ) Stand Option 2: Hard-mounted to countertop ( continued ) For use with kits #46-46 128, #46-46351 and MS951 Stand Replacements Step 3 Screw the stand anchor ( MLPN 50-50449 ) onto the base assembly until it sits flush. Step 4 Remove the logo plate on the stand by gently using an Exacto knife to release the pl ...

  • Metrologic MS9524 - page 19

    15 A SSEMBLING THE S T AND (C ONT .) Wall Mount, Option 1: For Kit #46-46433 or Kit #46-46508 Step 1: Drill two #39 pilot holes 3.00” ap art. Step 2: Attach the Wall Mount Hanger to the wall with the two #8 wood screws provided. Wall Mount, Option 2: Kit #46-46508 Step 1: Attach the Wall Mount Base to the Wall Mount Hanger with the t wo 4.8 x 13 ...

  • Metrologic MS9524 - page 20

    16 S CANNER P ARTS Description 1 White LED 2 Yellow LED* * This feature is not available on the MS9524 3 CodeGate Button* * This feature is not available on th e MS9524 4 Blue LED 5 Output Window Laser Aperture 6 Cable Connection Detachable PowerLink Ca ble Figure 31. ...

  • Metrologic MS9524 - page 21

    17 A UDIBLE I NDICATORS When the Voyager PDF is in operation, it provides audib le feedback. These sounds indicate the status of the scanner . Eight settings are availa ble for the tone of the beep (normal, 6 alternate tones and n o tone). To change the tone, refer to Metrologic's programming guide, MLPN 00-02544 or Metr oSet2’s help files. ...

  • Metrologic MS9524 - page 22

    18 V ISUAL I NDICATO RS The MS9544 has three LED indic ators (blue, white and yell ow) located on the head of the scanner. The MS9524 has t wo LED indicators (blue and white) located on the head of the scanner. When the scanner is on, the flashi ng or stationary activity of the LEDs indicate s the status of the current scan and the scanner. Blue, W ...

  • Metrologic MS9524 - page 23

    19 V ISUAL I NDICATO RS ( CONTINUED ) Alternating Flashi ng of Blue and White This indicates the scanner is program mod e. A razzberry tone indicates that an invalid bar co de has been scanned while in this mode . The scanner needs to have a F lash ROM upgrade if the alternating flashing of the white and blue LEDs occurs during startup and is accom ...

  • Metrologic MS9524 - page 24

    20 F AILURE M ODES One Razzberry Tone – On Po w er Up or During Scanning This indicates the scanner has experi enced motor or laser failure Three Beeps – On Pow er Up If the scanner beeps 3 times on power up then the non- volatile memory (NovRA M) that holds the scanner configuration has failed. If the scanner does not respond after reprogrammi ...

  • Metrologic MS9524 - page 25

    21 P ROGRAMMING M ODES The MS9524/44 Voyag er PDF Series has 3 modes of programming. ¾ Bar Codes Voyager PDF or Voyager PDF with CodeGate can be configured by scanning the bar codes located in Metrologic's programmi ng guides, MLPN 00-02544 and MLPN 00-02990 or MetroSet2’s help files. Please refer to these gui des for instructions. These ma ...

  • Metrologic MS9524 - page 26

    22 P ROGRAMMING M ODES ( CONTINUED ) 4. During programming, the motor and laser turn off. YOU CANNOT SCAN A BAR CODE WHILE IN SERIAL PROGRAM MODE. 5. There is a 20 second windo w between commands. If a 20-second timeout occurs, the scanner will send a [nak] and you must start over. 6. To enter serial program mode, send the follo wing command [stx]9 ...

  • Metrologic MS9524 - page 27

    23 P ROGRAMMING M ODES ( CONTINUED ) EXAMPLE #3: The following example sho ws the events that occur when an invalid bar code is sent. This sample will load the factory default settings an d then set the baud rate to 19200. HOST SCANNER FEATURE COMMAND ASCII REPRESENTATION RESPONSE Enter Program M ode [stx]999999[etx ] 02h 39h 39h 39h 39h 39h 3 9h 0 ...

  • Metrologic MS9524 - page 28

    24 U PGRADING THE F LASH ROM F IRMWARE The Meteor™ program is a function al component of Metrologic’s new line of Flash- based scanners. This program allo ws the user of a Metrologic scanner to quickly upgrade to a ne w or custom version of software. It requires the use of a personal computer running u nder Windows 95 or greater and the us e of ...

  • Metrologic MS9524 - page 29

    25 L ABELS Each scanner has a label on the back of the unit. This label has the model number, date of manufacture, serial number, CE an d caution information. The following is an example of this label: M AINTENANCE Smudges and dirt can interfere with the proper scanni ng of a bar code. Therefore, the output window will need occasional clea ning. 1. ...

  • Metrologic MS9524 - page 30

    26 D EPTH OF F IELD Figure 33. Minimum Bar Code Element Width ABCD E F GH J K mm .13 .15 - - .19 - .25 .33 .53 - mils 5.2 5.7 - - 7.5 - 10 13 21 - Specifications subject to change without notice. ...

  • Metrologic MS9524 - page 31

    27 D EPTH OF F IELD Figure 34. PDF417 Minimum Bar Code Element W idth AB mm .25 .38 mils 10 15 Specifications subject to change without notice. ...

  • Metrologic MS9524 - page 32

    28 IR A CTIVATION Figure 35. Specifications subject to change without notice. ...

  • Metrologic MS9524 - page 33

    29 A PPLICATIONS AND P ROTOCOLS The model number on each scann er includ es the scanner number and factory default communications protocol. Scanner Version Identifier Communication Protocol(s) -9 OCIA* and RS-232 Transmit/Receive -00 Laser Emulation* and RS-232 Transmit/Receive* -11 IBM 468X/469X, RS232-T XD, RXD, RTS, CTS -14 RS232-TXD, RXD, RTS, ...

  • Metrologic MS9524 - page 34

    30 T ROUBLESHOOTING G UIDE The following guide is for reference purp oses only. Contact a Metrologic representative at 1-800-ID -Metro or 1-800-436 -3876 to preserve the limited warranty terms. All Interfaces MS9524/44 Series Troubleshooting Guide Symptoms Possible Causes Solution No LEDs, beep or laser No power is being supplied to the scanner. Ch ...

  • Metrologic MS9524 - page 35

    31 T ROUBLESHOOTING G UIDE ( CONTINUED ) Symptoms Possible Causes Solution The unit powers up, but does not scan and/or beep. The bar code symbology trying to be scanned is not enabled. UPC/EAN, Code 39, interleaved 2 of 5, Code 93, Code 128, Codabar and PDF are enabled by def ault. Verify that the type of bar code being read has been selected. The ...

  • Metrologic MS9524 - page 36

    32 T ROUBLESHOOTING G UIDE ( CONTINUED ) Symptoms Possible Causes Solution The unit beeps at some bar codes and NOT for others of the same bar code symbology. The bar code may have been printed incorrectly. Check if it is a check digit/character/or border problem. The unit beeps at some bar codes and NOT for others of the same bar code symbology. T ...

  • Metrologic MS9524 - page 37

    33 T ROUBLESHOOTING G UIDE ( CONTINUED ) Symptoms Possible Causes Solution Alpha characters show as lower case. The computer is in Caps Lock mode . Enable Caps Lock detect setting of the scanner to detect if the PC is operating in Caps Lock. Everything works except for a couple of characters. These characters may not be supported by that country’ ...

  • Metrologic MS9524 - page 38

    34 RS-232 D EMONSTRATION P ROGR AM If an RS-232 scanner is not communicating with your IBM compatible PC, key in the following BASIC program to test that the communication port and scanner are work ing. This program is for demonstration purposes onl y. It is only intended to prove that cabling is correct, the com port is working, and the scanner is ...

  • Metrologic MS9524 - page 39

    35 D ESIGN S PECIFICATIONS D ESIGN S PECIFICATIONS O PER AT IO N AL Light Source: Visible Laser Diode 650 nm ± 10 nm Laser Power: Less than 1 mW (peak) Depth of Scan Field: 0 mm – 200 mm (0” – 8”) f or 0.330 mm (13 mil) bar code at default setting Scan Speed: 180 ±10 scan lines per second Scan Pattern: Single scan line Minimum Bar Width: ...

  • Metrologic MS9524 - page 40

    36 D ESIGN S PECIFICATIONS D ESIGN S PECIFICATIONS E LECTRICAL Input Voltage: 5.0VDC ± 0.25V Power: Operating = 900 mW (typical) Standby = 325 mW (typical) Current: Operating = 180 mA @ 5VDC (t ypical) Standby = 65 mA @ 5VDC (typical) DC Transformers: Class 2; 5.2VDC @ 650 mA Laser Class 1: IEC 60825-1:1993+A1:1997+A2:2001 EN 60825-1:1994+A11:1996 ...

  • Metrologic MS9524 - page 41

    37 D EFAULT S ETTINGS Many functions of the scanner can be “programmed” – that is, enabl ed or disabled. The scanner is shipped from the factor y programmed to a set of default conditions. The default parameter of the sca nner has an asterisk (*) in the charts on the following pages. If an as terisk is not in the default column then the defau ...

  • Metrologic MS9524 - page 42

    38 D EFAULT S ETTINGS ( CONTINUED ) PARA METER DEFA ULT OCI A RS-232 LIGHT PEN IBM 46XX KBW USB LASER EMULATION PDF CodeGate Inactive Out-of-Stand * 9 9 9 9 9 9 9 PDF CodeGate Active In-Stand 9 9 9 9 9 9 9 PDF CodeGate Inactive In-Stand * 9 9 9 9 9 9 9 Mod 43 Check on Code 39 9 9 9 9 9 9 9 MSI-Plessy 10 /10 Check Digit 9 9 9 9 9 9 9 MSI-Plessy M od ...

  • Metrologic MS9524 - page 43

    39 D EFAULT S ETTINGS ( CONTINUED ) PARA METER DEFA ULT OCI A RS-232 LIGHT PEN IBM 46XX KBW USB LASER EMULATION Same symbol rescan timeout 250 msecs 9 9 9 9 9 9 9 Same symbol rescan timeout 375 msecs 9 9 9 9 9 9 9 Same symbol rescan timeout: 500 msecs) 9 9 9 9 9 9 9 Same symbol rescan timeout 625 msecs 9 9 9 9 9 9 9 Same symbol rescan timeout 750 m ...

  • Metrologic MS9524 - page 44

    40 D EFAULT S ETTINGS ( CONTINUED ) PARA METER DEFA ULT OCI A RS-232 LIGHT PEN IBM 46XX KBW USB LASER EMULATIO N Parity Space 9 9 9 Baud Rate 9600 9 8 Data Bits 9 7 Data Bits * 9 Stop Bits 2 9 Transmit Sanyo ID Characters 9 9 Nixdorf ID 9 9 LRC Enabled 9 9 UPC Prefix 9 9 UPC Suffix 9 9 Carriage Return * 9 9 Line Feed-Disabled by default in KBW * 9 ...

  • Metrologic MS9524 - page 45

    41 D EFAULT S ETTINGS ( CONTINUED ) PARA METER DEFA ULT OCI A RS-232 LIGHT PEN IBM 46XX KBW USB LASER EMULATIO N Bookland 9 9 as code 39 9 9 9 as code 39 977 (2 digit) Supplemen tal Requirement 9 9 9 9 9 9 9 Supplements are not Required * 9 9 9 9 9 9 9 Two Digit Redundancy * 9 9 9 9 9 9 9 Five digit Redundancy 9 9 9 9 9 9 9 100 msec to Find Supplem ...

  • Metrologic MS9524 - page 46

    42 1 10 S CANNER AND C ABLE T ERMINATIONS Scanner Pinout Connections MS9524/44-41 RS-232C and Light Pen Emulation Pin Function 1 Ground 2 RS-232 T ransmit Output 3 RS-232 Rece ive Input 4 RT S Output 5 CT S Input 6 DT R Input/LTPN Source 7 Reserved 8 LT PN Data 9+ 5 V D C The MS9524 and MS9544 scanner interfaces terminate to a 10-pin modular jack. ...

  • Metrologic MS9524 - page 47

    43 1 10 S CANNER AND C ABLE T ERMINATIONS MS9524/44-9 OCIA Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RDATA 5 RDATA Return 6 Clock In 7 Clock Out 8 Clock in Return/Clock out Rtrn 9+ 5 V D C 10 Shield Ground MS9524/44-00 Laser Emul ation Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 Flip Sense/Start ...

  • Metrologic MS9524 - page 48

    44 S CANNER AND C ABLE T ERMINATIONS ( CONTINUED ) Cable Connector Configurations (Host End) “Standard” PowerLink Cable 53-53xxx-3 coiled or 54-54xxx-3 straight Pin Function 1 Shield Ground 2 RS-232 Transmit Output 3 RS-232 Receive Input 4 DTR Input/Light Pen Source 5 Power/Signal Ground 6 Light Pen Data (DSR Out for -14 interfaces) 7 CTS Input ...

  • Metrologic MS9524 - page 49

    45 S CANNER AND C ABLE T ERMINATIONS ( CONTINUED ) Cable Connector Configuration (Host End) Keyboard Wedge Po werLink Cable 53-53002 or 54-54002 Pin Function 1 Keyboard Clock 2 Keyboard Data 3 No Connect 4 Power Ground 5 +5 Volts DC Pin Function 1 PC Data 2 No Connect 3 Power Ground 4 +5 Volts DC 5 PC Clock 6 No Connect Metrologic will supply an ad ...

  • Metrologic MS9524 - page 50

    46 L IMITED W ARRANTY The MS9524/44 series scanners are manufactured by Metrologic at its Blackwood, New Jersey, USA facility. The MS9524/44 series scanners have a five (5) year limited warranty from the date of manufacture. Metrologic warrants and represents that all MS9524/ 44 series scanners are free of all defects in material, workmanshi p and ...

  • Metrologic MS9524 - page 51

    47 Notices and Cautions Notice This equipment has been tested and found to comply w ith the limits for a Class B digital device, pursuant to Part 15 o f the FCC rules. These limit s are designed to provide rea sonable protection ag ainst harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequen ...

  • Metrologic MS9524 - page 52

    48 P ATENTS “Patent Information This METROLOGIC product may be covered by one or more of the following US Patents: US Patent No. 4,958,98 4; 5,081,342; 5,260,553; 5,34 0,971; 5,340,973; 5,424,525; 5,468,951; 5,484,99 2; 5,525, 789; 5,528,024; 5,591,953; 5,6 16,908; 5,627,359; 5,661,292; 5,777,31 5; 5,789, 730; 5,789,731; 5,811,780; 5,8 25,012; 5, ...

  • Metrologic MS9524 - page 53

    49 Index A AC Input/Ou tlet .................. 5, 6, 7, 8 Accessori es ................................... 2 Adapter .......................................... 2 Approval s .................................... 25 Audible .................................. 16, 17 Autodiscrim inates ........................ 35 B Bar Code .......... 1, 4, 17, 18, 19, ...

  • Metrologic MS9524 - page 54

    50 Index P Parts .............................................. 2 Patent .......................................... 48 PC .............. 5, 8, 24, 29, 32, 33, 35, 42, 44, 45 PDF ............................................. 11 PDF417 ....................................... 27 Pin Assign ments .......................... 45 Port ..................... ...

  • Metrologic MS9524 - page 55

    ...

  • Metrologic MS9524 - page 56

    April 2003 Printed in the USA 00 - 02989 A ...

Manufacturer Metrologic Category Scanner

Documents that we receive from a manufacturer of a Metrologic MS9524 can be divided into several groups. They are, among others:
- Metrologic technical drawings
- MS9524 manuals
- Metrologic product data sheets
- information booklets
- or energy labels Metrologic MS9524
All of them are important, but the most important information from the point of view of use of the device are in the user manual Metrologic MS9524.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Metrologic MS9524, service manual, brief instructions and user manuals Metrologic MS9524. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Metrologic MS9524.

Similar manuals

A complete manual for the device Metrologic MS9524, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Metrologic MS9524 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Metrologic MS9524.

A complete Metrologic manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Metrologic MS9524 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Metrologic MS9524, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Metrologic MS9524, that we can find in the current document
3. Tips how to use the basic functions of the device Metrologic MS9524 - which should help us in our first steps of using Metrologic MS9524
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Metrologic MS9524
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Metrologic MS9524 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Metrologic MS9524?

Use the form below

If you did not solve your problem by using a manual Metrologic MS9524, ask a question using the form below. If a user had a similar problem with Metrologic MS9524 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)