  • LevelOne IFE-0501 - page 1

    LevelOne IFE-0501/IFE-0502 4-Port PoE + 1-Port SC Industrial Fast Ethernet Switch User Manual V er . 1.0.0-071 1 1 ...

  • LevelOne IFE-0501 - page 2

    FCC W arning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of t he FCC rules. These limits are designed to provide reasonable protection against harmful in terference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy . It may c ...

  • LevelOne IFE-0501 - page 3

    Content INTRODUCTION ...................................................................................... 4 F EA TURES ................................................................................................................. 4 P ACKAGE C ONTENTS .............................................................................................. ...

  • LevelOne IFE-0501 - page 4

    Introduction The 4-Port PoE + 1-Port SC I ndustrial Fast Ethernet Switch is a cost-effective solution and meets the high reliability requirement s demanded by industrial applications. Using fiber port can extend the connection distance t hat increases the network elasticity and performance. In addition, the industrial switch provides the PoE functi ...

  • LevelOne IFE-0501 - page 5

    Package Content s Please refer to the package content s list below to verify them against the checklist.  IFE-0501(or IFE-0502)  CD Manual  Pluggable T erminal Block (att ached on the switch)  2 wall mount plates with screws  One DIN-Rail (attached on the switch) Compare the content s of the i ndustrial switch with the standar d chec ...

  • LevelOne IFE-0501 - page 6

    Hardware Description In this paragraph, the Industrial switch’ s hardware spec, port, cabling information, and wiring installation will be described. Physical Dimension 4-Port PoE + 1-Port SC Industrial Fast Et hernet Switch dimension (W x D x H) is 30mm x 95mm x 140mm Front Panel The Front Panel of the 4-Port PoE + 1-Port Multi-mode SC Indust ri ...

  • LevelOne IFE-0501 - page 7

    The Front Panel of the 4-Port PoE + 1-Port Single-mode SC Indus trial Fast Ethernet Switch is shown as below: Front Panel of the IFE-0502 Indus trial Fast Ethernet Switch T op V iew The top view of the 4-Port PoE + 1-Port SC Industrial Fast Et hernet Switch has one terminal block connector of two DC power inputs. T op V iew of the IFE-0501/IFE-0502 ...

  • LevelOne IFE-0501 - page 8

    LED Indicators The diagnostic LEDs located on the front pa nel of the industrial switch provide real-time information of system and optional status. The following t able provides the description of the LED status and their meanings for the switch. LED Color Description On Power input 1 is active P1 Green Off Power input 1 is inactive On Power input ...

  • LevelOne IFE-0501 - page 9

    Port s  RJ-45 ports The UTP (RJ-45) Fast Ether net port s will auto-sense for 10Base-T or 100Base-TX connections. Auto MDI/MDIX me ans that the switch can connect to another switch or workstation without changing straight thr ough or crossover cabling. See the below figures for straight through and crossover cable schematic.  RJ-45 Pin Assign ...

  • LevelOne IFE-0501 - page 10

    S traight Through Cable Schematic Cross Over Cable Schematic  Fiber Port The fiber port of SC type connector can wo rk in multi-mode (2Km) or single-mode (30Km). When you connect the fiber port to another one, pleas e follow the figure below to connect accordingly . Wrong conne ction will cause the port cannot work normally . A TTE NTION This is ...

  • LevelOne IFE-0501 - page 11

    Cabling  T wisted-pair segment c an be connected with unshielded twisted p air (UTP) or shielded twisted pair (STP) cable. The cable must comply with the IEEE 802.3u 100Base TX st andard for Category 5. The cable between the converter and the link partner (switch, hub, workst ation, et c.) must be less than 100 meters (328 f t.) long.  Fiber ...

  • LevelOne IFE-0501 - page 12

    Wiring the Power Input s Please follow the steps below to insert the power wire. Insert the positive and negative wires into t he V+ and V - contacts on the terminal block connector . T ighten the wire-clamp scr ews for preventing the wires from loosing. 12 ...

  • LevelOne IFE-0501 - page 13

    Wiring the Fault Alarm Cont act The fault alarm contact is in the middle of terminal block connector as the picture shows below . When the wires are inserted in to ports 3 and 4, t hey automatically detect the fault status in the event of a power failure by forming an open circuit. An example for the fault ala rm contact is shown as below: Insert t ...

  • LevelOne IFE-0501 - page 14

    Mounting Installation DIN-Rail Mounting The DIN-Rail is screwed on the i ndustrial switch when out of factory . If the DIN-Rail is not screwed on the industrial switch, please see the following pictures to screw the DIN-Rail on the switch. Follow the step s below to hang the industrial switch. 1. Use the screws to screw the DIN-Rail on the rear sid ...

  • LevelOne IFE-0501 - page 15

    4. Then, lightly push the DI N-Rail into the track. 5. Check if the DIN-Rail is tightened on the track or not. 6. T o remove the industrial switch from the track, reverse steps above. 15 ...

  • LevelOne IFE-0501 - page 16

    W all Mount Plate Mounting 1. Follow the steps below to mount the industrial switch wit h wall mount plate. 2. Remove the DIN-Rail from the industrial switch; loose the screws to remove the DIN-Rail. 3. Place the wall mount plate on the rear panel of the industrial switch. 4. Use the screws to screw the wall mount plate on the industrial switch. 5. ...

  • LevelOne IFE-0501 - page 17

    Hardware Installation In this paragraph, we are going to mention how to install the 4-Port PoE + 1-Port SC Industrial Fast Ethernet Switch and the installation point s to be attended to it. Inst allation Step s 1. Unpack the Industrial switch p acking. 2. Check if the DIN-Rail is screwed on the Industrial switch or not. If the DIN-Rail is not screw ...

  • LevelOne IFE-0501 - page 18

    Network Application This segment provides the sample to help user have more actual idea of industrial switch application. For a sample applicati on of the industrial s witch, see the figure below . 18 ...

  • LevelOne IFE-0501 - page 19

    Troubleshooting  V erify that is using the right power cord/adapter (DC 48V), please don’t use the power adapter with DC output voltage hi gher than 48V , or it will burn this equipment down.  Select the proper UTP/STP cable to constr uct your network. Please check that is using the right cable. Use unshielded twiste d-pair (UTP) or shield ...

  • LevelOne IFE-0501 - page 20

    Technical Specification The IFE-0501/IFE-0502 4-Port PoE + 1-Port SC Industrial Fast Ethernet Switch technical specifications are shown as below . IFE-0501 4-Port PoE + 1-Port Multi-mode SC Industrial Fast Ethernet Switch IFE-0502 4-Port PoE + 1-Port Single-mode SC Industrial Fast Ethernet Switch Standard IEEE 802.3 10Base-T Ethernet IEEE 802.3u 10 ...

  • LevelOne IFE-0501 - page 21

    Optical cable Dist ance: Multi mode: 50/125 μ m ~ 62.5/125 μ m Single mode: 9/125 μ m A vailable distance: 2km (mul ti-mode)/30km (single-mode) W avelength: 1310nm (Multi-mode/Single-mode) Power Suppl y Redundant power DC 48V with removable terminal block 12VDC (without PoE); 48VDC (Full load with PoE) Power Consumption 4.6W att s (without PoE); ...

Manufacturer LevelOne Category Switch

Documents that we receive from a manufacturer of a LevelOne IFE-0501 can be divided into several groups. They are, among others:
- LevelOne technical drawings
- IFE-0501 manuals
- LevelOne product data sheets
- information booklets
- or energy labels LevelOne IFE-0501
All of them are important, but the most important information from the point of view of use of the device are in the user manual LevelOne IFE-0501.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals LevelOne IFE-0501, service manual, brief instructions and user manuals LevelOne IFE-0501. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product LevelOne IFE-0501.

Similar manuals

A complete manual for the device LevelOne IFE-0501, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use LevelOne IFE-0501 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of LevelOne IFE-0501.

A complete LevelOne manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual LevelOne IFE-0501 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the LevelOne IFE-0501, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the LevelOne IFE-0501, that we can find in the current document
3. Tips how to use the basic functions of the device LevelOne IFE-0501 - which should help us in our first steps of using LevelOne IFE-0501
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with LevelOne IFE-0501
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of LevelOne IFE-0501 in a specific country, if it was not possible to solve the problem on our own.