Manual Atlona AT-H2H-44M

30 pages 2.82 mb
Download

Go to site of 30

Summary
  • Atlona AT-H2H-44M - page 1

    User Manual Atlona HDMI to HDMI Matrix Switcher A T-H2H-44M and A T-H2H-88M (pictured below) atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 ...

  • Atlona AT-H2H-44M - page 2

    2 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 1. Introduction ............................................................................................ 3 2. Package Contents ............................................................................................ 3 3. Features ................................................... ...

  • Atlona AT-H2H-44M - page 3

    3 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 Intr oduction Multiple control options, HD resolutions, and the best audio, the Atlona HDMI ® to HDMI matrix switcher is built for your home and professional needs. With the ability to pass 1080p, 1920x1200, all Lossy and Lossless audio formats (including Dolby ® TrueHD and DTS-HD Maste ...

  • Atlona AT-H2H-44M - page 4

    4 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 The IR receiver window can sometimes pick up stray reflected IR commands causing loss of functionality. To disable the front panel, see directions below: Panel Description Front Panel IR AT-H2H-88M AT-H2H-88M DC 24V ENTER POWER EDID MEMORY ALL DEFAULT CANCEL FUNCTION 1 2 3 5 6 7 8 4 COAXI ...

  • Atlona AT-H2H-44M - page 5

    5 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 1. Matrix IR IN: Connect included IR receiver (see picture below) 2. RS-232: Connect to this port for control from a computer or 3rd control box. 3. Firmware Update: Type B USB Port used for updating the matrix firmware only 4. Coax Out: Audio de-embedding for distribution amplifiers and ...

  • Atlona AT-H2H-44M - page 6

    6 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 AT-H2H-88M AT-H2H-88M DC 24V ENTER POWER EDID MEMORY ALL DEFAULT CANCEL FUNCTION 1 2 3 5 6 7 8 4 COAXIAL OUT HDMI OUT HDMI IN RS-232 ETHERNET IR IN FIRMWARE 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Connection Diagram ARC Digital audio de-embedding ARC ...

  • Atlona AT-H2H-44M - page 7

    7 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 I/O Control The AT-H2H’ s front panel has 3 functions: I/O control, EDID, and matrix settings. The following sections go over step by step setup & control. To set an input to an output To mirror all inputs and outputs -- Ex. Input 1 to output 1, input 2 to output 2, etc. To route on ...

  • Atlona AT-H2H-44M - page 8

    8 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 To load a saved I/O route To save an I/O route to memory Once inputs and outputs have been set they can be saved to memory and recalled later. Multiple individual input/output routes can be saved. The route will remain in memory until a new route has been saved to that memory number or th ...

  • Atlona AT-H2H-44M - page 9

    9 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 To copy an EDID ---> ---> ---> ---> AT-H2H-XXM Select Input Number Select Function Option home screen 1 To copy up to X EDIDs 2 To choose input EDID ---> ---> Copy from output # Save to Memory (1-4/8) # Copy from output # Save to Memory (1-4) # Feedback = ”Saved port # ...

  • Atlona AT-H2H-44M - page 10

    10 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 Step 2: load a copied EDID onto an input ---> ---> ---> ---> AT-H2H-XXM Select Input Number Select Function Option home screen 1 To copy up to 4/8 EDIDs 2 To choose input EDID Input # Select an input port Input # Press Enter Current: Default Input: # Mode: 1.Default 2.Saved 3 ...

  • Atlona AT-H2H-44M - page 11

    11 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 Step 3: Load an internal EDID to an input ---> ---> ---> ---> AT-H2H-XXM Select Input Number Select Function Option home screen 1 To copy up to 4/8 EDIDs 2 To choose input EDID Input # Select an input port Input # Press Enter Current: Default Input: # Mode: 1.Default 2.Saved ...

  • Atlona AT-H2H-44M - page 12

    12 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 Matrix Settings When installing or troubleshooting it’ s important to verify settings, or be able to come back to a project and see how it was set up. The AT-H2H has matrix settings viewable through the front panel. View current I/O settings, firmware version, FPGA version, and the bau ...

  • Atlona AT-H2H-44M - page 13

    13 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 ARC enables a source connected to a display to route audio to an AVR or zone amp. The S/PDIF port is used for two audio options, ARC or matrix source audio de-embedding. When using one, the other is disabled. By default the matrix comes with ARC turned off on all ports, this enables the ...

  • Atlona AT-H2H-44M - page 14

    14 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 AT-H2H-88M AT-H2H-88M DC 24V ENTER POWER EDID MEMORY ALL DEFAULT CANCEL FUNCTION 1 2 3 5 6 7 8 4 COAXIAL OUT HDMI OUT HDMI IN RS-232 ETHERNET IR IN FIRMWARE 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Matrix source audio loop-out By default the matrix is enabled to de-embed source au ...

  • Atlona AT-H2H-44M - page 15

    15 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 RS-232 Connection RS-232 is connected through a 9-pin female DB connector. Only pins 2, 3, and 5 are terminated. No. Pin Function 1 ---- Not used 2 Tx Transmit 3 Rx Receive 4 ---- Not used 5 Gnd Ground 6 ---- Not used 7 ---- Not used 8 ---- Not used 9 ---- Not used 1 2 3 4 5 9 8 7 6 Set ...

  • Atlona AT-H2H-44M - page 16

    16 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 TCP/IP For convenience, the matrix comes with DHCP default on. This enables the matrix to be connected to a network or network device with no worries of the IP overriding another device. TCP/IP WebGUI Note: H2H-44M and H2H-88M screen shots will display alternately to show both GUIs Atlon ...

  • Atlona AT-H2H-44M - page 17

    17 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 The home screen tab will display the general system information. If the matrix is powered off the FPGA will not display (see first image). Once the power is on it will display (see second image). Note: When the matrix is turned off many fields within the WebGUI will not display informati ...

  • Atlona AT-H2H-44M - page 18

    18 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 Note: Be sure to save all changes before moving to the next page The network set up page will allow the IP information to be changed. When a change is made the screen will grey and the ability to save or cancel will display at the bottom (see below). Note: When DHCP is on, the IP cannot ...

  • Atlona AT-H2H-44M - page 19

    19 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 The config page under status/setting will allow power to be turned off/on, the front IR window to be turn off/on (see page 4), and the matrix baud rate to be changed. Note: Default baud rate of the matrix has been set for the best compatiblity with other devices (i.e. projectors). Baud r ...

  • Atlona AT-H2H-44M - page 20

    20 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 Adding, deleting, and updating users can also be done from the config page. User changes can only be done by the admin. Admin user name is always “root” and default password is “Atlona”. Note: Only the admin password can be changed. The username will always remain “root” Note ...

  • Atlona AT-H2H-44M - page 21

    21 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 The I/O page allows input and output routes to be changed easily by drop down menu. Output All will route one selected input to all the outputs. Note: All routes can be changed while in the grey edit screen. Remember to save after all changes have been made. ...

  • Atlona AT-H2H-44M - page 22

    22 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 For compatibility and ease of use, EDID configuration has been added. Each input has a drop down selection for internal, default, and saved EDIDs (see pages 9-11 for EDID information). Note: When saving an EDID to memory through the WebGUI, the output will save to the corresponding memor ...

  • Atlona AT-H2H-44M - page 23

    23 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 The HDCP page will display the output’ s ability to support HDCP content or not. Several messages will appear under different circumstances: Supported - HDCP is supported by the display Not Supported - The display is unable to support HDCP Non-HDCP Source - A source that does not suppo ...

  • Atlona AT-H2H-44M - page 24

    24 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 Command Feedback Description IPCFG IP Addr : x.x.x.x Netmask : x.x.x.x Gateway : x.x.x.x IP Port: x.x.x Displays IP address configuration IPTimeout XX IPTimeout XX (Ex. IPTimout120) Determines amount of seconds of inactivity before TCP/IP disconnects IPQuit IPQuit Logs out of TCP/IP IPAd ...

  • Atlona AT-H2H-44M - page 25

    25 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 IPDelUser [X] TCP/IP user was deleted Delete a user from TCP/IP X=User (Ex. IPDelUser Atlona) IPDHCP sta IPDHCP sta Ex. IPDHCP on Displays the status of DHCP IPDHCP on IPDHCP on Turns DHCP on IPDHCP off IPDHCP off Turns DHCP off IPStatic [X] [Y] [Z] IPStatic address netmask gateway Sets ...

  • Atlona AT-H2H-44M - page 26

    26 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 Updating and Resetting Updating firmware Resetting to factory settings Atlona has made field firmware updating easy. Simply download firmware from Atlona.com and upload the file to the matrix. NOTE: Only use a Windows computer to update the matrix. Use of an Apple computer to update will ...

  • Atlona AT-H2H-44M - page 27

    27 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 Bandwidth 6.75Gbps Ports Video input Video output Audio output IR input Control: RS-232 Control: TCP/IP Firmware update AT-H2H-44M 4 x HDMI 4 x HDMI 4 x S/PDIF 1 x 3.5 mm 1 x 9pin (RS-232) 1 x RJ45 1 x USB B AT-H2H-88M 8 x HDMI 8 x HDMI 8 x S/PDIF 1 x 3.5 mm 1 x 9pin (RS-232) 1 x RJ45 1 ...

  • Atlona AT-H2H-44M - page 28

    28 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 Safety Information Safeguards Precautions FCC regulations state that any unauthorized changes or modifications to this equipment, not expressly approved by the manufacturer, could void the user’ s authority to operate this equipment. Operate this product using only the included externa ...

  • Atlona AT-H2H-44M - page 29

    29 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 Atlona, Inc. (“Atlona”) Limited Pr oduct Warranty Policy Coverage Atlona warrants its products will substantially perform to their published specifications and will be free from defects in materials and workmanship under normal use, conditions and service. Under its Limited Product W ...

  • Atlona AT-H2H-44M - page 30

    30 atlona.com Toll free: 1-877-536-3976 Local: 1-408-962-0515 Atlona, Inc Pr oduct Registration Thank you for purchasing this Atlona product. - We hope you enjoy it and will take an extra few moments to register your new purchase. Registration creates an ownership record if your product is lost or stolen and helps ensure you’ll receive notificati ...

Manufacturer Atlona Category Plumbing Product

Documents that we receive from a manufacturer of a Atlona AT-H2H-44M can be divided into several groups. They are, among others:
- Atlona technical drawings
- AT-H2H-44M manuals
- Atlona product data sheets
- information booklets
- or energy labels Atlona AT-H2H-44M
All of them are important, but the most important information from the point of view of use of the device are in the user manual Atlona AT-H2H-44M.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Atlona AT-H2H-44M, service manual, brief instructions and user manuals Atlona AT-H2H-44M. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Atlona AT-H2H-44M.

Similar manuals

A complete manual for the device Atlona AT-H2H-44M, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Atlona AT-H2H-44M by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Atlona AT-H2H-44M.

A complete Atlona manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Atlona AT-H2H-44M - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Atlona AT-H2H-44M, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Atlona AT-H2H-44M, that we can find in the current document
3. Tips how to use the basic functions of the device Atlona AT-H2H-44M - which should help us in our first steps of using Atlona AT-H2H-44M
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Atlona AT-H2H-44M
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Atlona AT-H2H-44M in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Atlona AT-H2H-44M?

Use the form below

If you did not solve your problem by using a manual Atlona AT-H2H-44M, ask a question using the form below. If a user had a similar problem with Atlona AT-H2H-44M it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)