    DS2400 INSTA LLA TION MA NUA L ...

  • Datalogic Scanning DS2400 - page 3

    We Datalogic S.p.A . Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy declare under our sole respons ibility that t he produc t DS2400-XXXX, Laser Scanner and all its model s to which this declarati on relates i s in conf ormit y with the foll owing standards or other norm ative docum ents EN 55022, A ugust 1994 :L IMITS AND METHODS OF MEA ...

  • Datalogic Scanning DS2400 - page 4

    iii CONTENTS GUIDE TO INSTALLA TION ............................................................... v General View ..................................................................................... vi SA FETY PRECA UTIONS ................................................................ vii Laser Safety............................................ ...

  • Datalogic Scanning DS2400 - page 5

    iv 3 REA DING FEATURES .................................................................... 3.1 3.1 Step-Ladder Mode ........................................................................... 3.1 3.2 Picket- Fence Mode .......................................................................... 3.2 3.3 Perform ance .................................. ...

  • Datalogic Scanning DS2400 - page 6

    v GUIDE TO INSTA LLA TION The following can be used as a check list to verify all of the steps nec essary for c omplete ins tallation of the DS2400 sc anner. 1) Read all inform ation in the sec tion "Safety Precautions” at the beginning of this m anual. 2) Cor rectly position and m ount the scanner f or barcode r eading according to the info ...

  • Datalogic Scanning DS2400 - page 7

    vi DS2400 General View Figure A 1 2 3 4 Pow er ON Data Tx LED External Trigger LED Good Read LED Laser ON LED 5 6 7 8 Warning and Device Cl ass Label s Laser Beam Output Window Access ory Mounti ng Holes Mounting Holes 5 6 7 2 1 3 8 4 ...

  • Datalogic Scanning DS2400 - page 8

    vii SA FETY PRECA UTIONS LA SER SAFETY The f ollowing inform ation is provided to c om ply with the rules im posed by international authorities and r efers to the c orrect us e of the DS2400 scanner . Standard Regulations This scanner utilizes a low-power laser diode. Although staring dir ectly at the laser beam mom entarily causes no known biologi ...

  • Datalogic Scanning DS2400 - page 9

    viii W arning labels indic ating exposur e to laser light and the device clas sif ication are applied onto the body of the scanner ( Figure A, 5 ). Warni ng and devi ce cl ass labels Disconnect the power s upply when opening the device during maintenanc e or installation to avoid exposure to hazardous las er light. The laser diode used in this devi ...

  • Datalogic Scanning DS2400 - page 10

    DA TA LOGIC DS2400 General Features - 1. 1 1 GENERA L FEA TURES 1.1 INTRODUCTION The DS2400 laser scanner satis fies the m ost advanc ed needs of a wide range of us ers. It has been developed focus ing on the realistic requirem ents of its target m ark et. The outs tanding result is an ex tremely com pact, cost- eff ective and easy to use industria ...

  • Datalogic Scanning DS2400 - page 11

    DS2400 DA TA LOGIC 1.2 - General Features • com pletely configurable via serial inter face ( W inHos t  ). • 2 serial com m unication interf aces. • supply voltage from 10 to 30 Vdc . • reads all popular c odes. • test m ode to verify the reading features and exac t positioning of the scanner without the need for external tools. • pr ...

  • Datalogic Scanning DS2400 - page 12

    DA TA LOGIC DS2400 General Features - 1. 3 1.3 A VAILA BLE MODELS The DS2400 scanner is available in versions that dif fer in regard to the following param eters: • Reading range • Serial interfac es • Linear or ras ter reading • Connections The f ollowing models are therefor e available: DS2400 - X X X X Rea ding R a nge 1 = Medium range 2 ...

  • Datalogic Scanning DS2400 - page 13

    DS2400 DA TA LOGIC 1.4 - General Features 1.4 A CCESSORIES The f ollowing accessories are available on request f or the DS2400: • 90° deflec tion mir ror GFC-2100 • 20 m A Current Loop interfac e INT-22 1.5 GFC-2100 A CCESSORY IN STA LLATION GFC-2100 is a 90° def lection m irror available on reques t for DS2400. T he installation of the 90° ...

  • Datalogic Scanning DS2400 - page 14

    DA TA LOGIC DS2400 Installatio n - 2.1 2 INSTA LLA TION 2.1 PA CKA GE CONTENTS Verify that the DS2400 reader and all the parts s upplied with the equipment are present and intac t when opening the packaging; the list of parts inc ludes: 1. DS2400 reader with cable 2. Installation manual 3. Bar code test c hart (PCS = 0.9) 4. DS2400 configur ation p ...

  • Datalogic Scanning DS2400 - page 15

    DS2400 DA TA LOGIC 2.2 - Installatio n 2.2 MECHA NICA L INSTALLA TION DS2400 can be installed to operate in different pos itions. T he four sc rew holes (M4 x 5) on the body of the reader are f or m echanic al f ixtur e (F igure A, 5 ). T he diagram s below give the overall dim ensions of the scanner and mounting br ack et and may be used for ins t ...

  • Datalogic Scanning DS2400 - page 16

    DA TA LOGIC DS2400 Installatio n - 2.3 2.3 JUNCTION BOX INSTALLA TION The Junc tion Box provides a pas sive connection between your sc anner and the outside world in a fast and pr actical way . It repres ents an alternative to the 25-pin connector s. Figure 2.3 shows the bas ic lay out of a scanner using the junction box. Scanner cable Junction Box ...

  • Datalogic Scanning DS2400 - page 17

    DS2400 DA TA LOGIC 2.4 - Installatio n T h e J u nc t i o n B ox is designed to be m ounted to a panel of m etal, plastic or other appropriate mater ial using the m ounting s crews provided in the pack age. T o do this: 1) Open the junction box by unscrewing the 4 cover sc rews. If neces sary, using the tw o m ounting holes inside the junc tion box ...

  • Datalogic Scanning DS2400 - page 18

    DA TA LOGIC DS2400 Installatio n - 2.5 2.3.2 Junction Box Electrical Connections The connec tion and wiring procedure f or Junc tion Box is desc ribed as follows: 1) Open the j unction box by unscrewing the 4 cover sc rews. 2) Pass all Sy stem cables thr ough the glands in the junction box housing. 3) T o connect the power and input/output signals ...

  • Datalogic Scanning DS2400 - page 19

    DS2400 DA TA LOGIC 2.6 - Installatio n J. Box Pinout for DS2400 Pin Name 01 VS 02 GND 03 VS 04 GND 05 CHASSIS 06 VS 07 VS 08 EXT TR IG + 09 EXT TR IG - 10 GND 11 GND 12 VS 13 VS 14 N.C. 15 N.C. 16 GND 17 GND 18 OUT1 + 19 OUT REF 20 OUT2 + 21 N.C. 22 N.C. 23 N.C. *24 *25 *26 Main interf ace signal s see table bel ow 27 N.C. 28 GND 29 30 31 32 33 Mai ...

  • Datalogic Scanning DS2400 - page 20

    DA TA LOGIC DS2400 Installatio n - 2.7 4) After wiring the junction box and while the scanner is unplugged fr om the power, place the Scanner cable s o that the rubber seal f its into the cutout in the housing of the j unction box and plug the 24 pin connec tor into connector J 1 on the PCB inside the junction box as shown in Figure 2.9. Scanner ca ...

  • Datalogic Scanning DS2400 - page 21

    DS2400 DA TA LOGIC 2.8 - Installatio n 2.4 ELECTRICA L CONNECTIONS DS2400 25-pin connector m odels are equipped with a cable term inated by a 25-pin fem ale D-s ub connector f or connection to the power supply and input/output signals. The details of the connector pins are indicated in the f ollowing table: Figure 2.10 - 25-pin female D-sub connect ...

  • Datalogic Scanning DS2400 - page 22

    DA TA LOGIC DS2400 Installatio n - 2.9 2.4.1 Powe r Supply Power can be supplied to the sc anner through the pins provided on the 25- pin connector us ed for c omm unication with the host: Earth Grou nd USER INTERFACE CHASSIS VGND V+ (10 - 30 Vdc) 13 25 1 VS GND CHASSIS DS240 0 Figure 2.11 - Power supply connections The power m ust be between 10 an ...

  • Datalogic Scanning DS2400 - page 23

    DS2400 DA TA LOGIC 2.10 - Installatio n RS232 Interface The s erial interfac e is used in this case f or point to point connections ; it handles com m unication with the host computer and allows both transm iss ion of code data and the pr ogram ming of the scanner. T his is the def ault setting. The f ollowing pins are used for RS232 interface c on ...

  • Datalogic Scanning DS2400 - page 24

    DA TA LOGIC DS2400 Installatio n - 2.11 START OF TRAN SMISSION EN D OF TRAN SMISSION + V RTS - V + V TX D ATA - V + V CTS - V DATA TRANSMI SSION DATA TRANSMI SSION C1 C2 C4 C3 C5 TRANSMI SSION STOPPED ENABLED DISABLE D ENABLED IDLE IDL E Figure 2.13 - RS232 control si gnals If the RTS/CTS handshak ing protocol is enabled, the DS2400 activates the R ...

  • Datalogic Scanning DS2400 - page 25

    DS2400 DA TA LOGIC 2.12 - Installatio n DS240 0 TX485+ 2 TX485- 4 RX485+ 3 RX 485 RX485- 5 TX485 7 SGND SGND USER INTERFACE + - + - + Figure 2.14 - RS485 full -duplex connections RS485 Half- Duplex Interface The RS485 half -duplex (3 wires + shield) interf ace is us ed f or polled com munic ation protocols. It can be used in a m aster/s lave lay ou ...

  • Datalogic Scanning DS2400 - page 26

    DA TA LOGIC DS2400 Installatio n - 2.13 Figure 2.16 shows a multidrop c onfiguration with DS2400 scanner s connected to a Multiplexer . max 2 m DS2400 # x (up to 31) DS2400 # 1 DS2400 # 0 RTX485 + RTX485 - RTX485 - RTX485 + Three wires + shield 120 Ohm 120 Ohm CHASSIS SGND max 1 200 m RS48 5 R EF SHIELD MULTIP LEXER Figure 2.16 - DS2400 M ultidrop ...

  • Datalogic Scanning DS2400 - page 27

    DS2400 DA TA LOGIC 2.14 - Installatio n 5 3 USER I NTER FACE C.L. IN- C.L. IN+ MAX . 300 METERS I = 20 mA 4 C.L. OUT- 2 C.L. OUT+ I = 20 mA DS2400 Figure 2.17 - 20 mA C.L. connections 2.4.3 Au xiliary RS232 Interface The auxiliary serial interface is used exc lusively for RS232 point to point connections. The parameters relative to the aux interfac ...

  • Datalogic Scanning DS2400 - page 28

    DA TA LOGIC DS2400 Installatio n - 2.15 The RT SAUX and CT SAUX signals c ontrol data transm ission and synchronize the connec ted devices. If the RT S/CTS handshak ing protocol is enabled, the DS2400 activates the RTSAUX output to indic ate a message is to be transm itted. The r eceiving unit activates the CT SAUX input to enable the transm ission ...

  • Datalogic Scanning DS2400 - page 29

    DS2400 DA TA LOGIC 2.16 - Installatio n EXTERNA L TRIGGER DS24 00 Signal 18 19 + 5V VS 9 25 GND Ground V EXT TRIG+ EXT TRIG- Figure 2.20 - Input NPN com mand using DS2400 pow er 18 19 + 5V DS2400 EXTE R NAL TRIGGER 30 Vdc max. Vext V Sign al Ground EXT TRIG+ EXT TRIG- Figure 2.21 - Input PNP command using external power EX TERNAL TRI G GER DS2 400 ...

  • Datalogic Scanning DS2400 - page 30

    DA TA LOGIC DS2400 Installatio n - 2.17 2.4.5 Outputs There ar e two general purpose outputs. T he following pins are pres ent on the 25-pin connector of the sc anner: Pin Name Function 8 OUT1+ Output 1 + 22 OUT REF Output ref erence 11 OUT2+ Output 2 + 12 OUT REF Output ref erence USER INTERFA CE Vext 40 Vdc max OUT 1 8 22 OUT REF DS2400 and/or DS ...

  • Datalogic Scanning DS2400 - page 31

    DS2400 DA TA LOGIC 2.18 - Installatio n The Pitch angle is represented by the value P in Figure 2.24. Pos ition the reader in order to minimize the Pitch angle. DS24 00 Figure 2.24 - Pitch A ngle The Skew angle is repres ented by the value S in Figure 2.25. P osit ion the reader to assure at least 10° for th e Skew angle. This avoids the direc t r ...

  • Datalogic Scanning DS2400 - page 32

    DA TA LOGIC DS2400 Installatio n - 2.19 2.6 TYPICA L LA YOUTS The f ollow ing ty pical layouts refer to system hardware configurations . Dotted lines in the figures r efer to optional hardware conf igurations within the particular layout. These layouts also require the correct setup of the software configur ation parameters. Complete software confi ...

  • Datalogic Scanning DS2400 - page 33

    DS2400 DA TA LOGIC 2.20 - Installatio n 2.6.2 Pass Through Pass through m ode allow s two or mor e devices to be connected to a s ingle external ser ial interface. Each DS2400 transm its the m ess ages received by the auxiliary interface onto the main inter face. All mes sages will be pas sed through this c hain to the host. When On-Line Oper ating ...

  • Datalogic Scanning DS2400 - page 34

    DA TA LOGIC DS2400 Installatio n - 2.21 2.6.3 RS232 Master/Slav e The RS232 m aster/s lave connection is us ed to collec t data f rom sever al scanners to build either an multi-point or a m ulti-sided reading sy s tem; there can be one m aster and up to 9 slaves connected together. The Slave sc anners use RS232 only on the main and auxiliar y seria ...

  • Datalogic Scanning DS2400 - page 35

    DS2400 DA TA LOGIC 2.22 - Installatio n 2.6.4 RS485 Master/Slav e The RS485 m aster/s lave connection is us ed to collec t data f rom sever al scanners to build either a m ulti-point or a m ulti-s ided reading sy stem ; there can be one m aster and up to 5 slaves connected together. The slave sc anners are connec ted together using RS485 half -dupl ...

  • Datalogic Scanning DS2400 - page 36

    DA TA LOGIC DS2400 Installatio n - 2.23 NOTE The auxiliary serial interfac e of the slave sc anners can be us ed in Local Echo c ommunication mode to control any single scanner (visualize collect ed data) or to configure it us ing the WinHost utility or Hos t Mode Programming proc edure. The termination resistors of the RS485 bus mus t not be insta ...

  • Datalogic Scanning DS2400 - page 37

    DS2400 DA TA LOGIC 2.24 - Installatio n This page is i nt entionally lef t blank. ...

  • Datalogic Scanning DS2400 - page 38

    DA TA LOGIC DS2400 Technical Feat ures - 3.1 3 REA DING FEA TURES The num ber of scans perform ed on the code by the DS2400 and therefore the decoding capability is influenced by the following parameters : • number of sc ans per sec ond • code m otion speed • label dimensions • scan direc tion with respect to code m otion About 5 scans dur ...

  • Datalogic Scanning DS2400 - page 39

    DS2400 DA TA LOGIC 3.2 - Technic al Feat ures For exam ple, the DS2400 ( 800 scans/s ec.) for a 25 m m high code m oving at 1250 mm /s perform s: [(25/1250) * 800] - 2 = 14 eff ective sc ans. 3.2 PICKET-FENCE MODE If scanning is parallel to the code motion, ( Figure 3.2 - "pick et-fence" m ode), the number of eff ective sc ans is given by ...

  • Datalogic Scanning DS2400 - page 40

    DA TA LOGIC DS2400 Technical Feat ures - 3.3 3.3 PERFORMANCE The DS2400 s canner is available in dif ferent ver sions accord ing to the reading perfor manc e. mm (mils) scans/s 1XX X 0.25 (10) 400 to 1000 2XX X 0.35 (14) 400 to 1000 1XX X 100 mm (4 in) - 440 mm (17 in) on 0.50 mm (20 mils) codes 2XX X 200 mm (8 in) - 600 mm (23.5 in) on 0.50 mm (20 ...

  • Datalogic Scanning DS2400 - page 41

    DS2400 DA TA LOGIC 3.4 - Technic al Feat ures 3.4 REA DING DIA GRAMS DS2400-1XXX (Medium Reading Range) ≥ 0.50 mm (20 mils) 0 20 cm 15 10 5 15 5 10 20 10 20 30 0.35 mm (14 mils) 40 50 60 70 cm 0.25 mm (10 mils) CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 "Pitch" angle = 0 ° "Skew" angle = 10 ° "Tilt" an ...

  • Datalogic Scanning DS2400 - page 42

    DA TA LOGIC DS2400 Technical Feat ures - 3.5 DS2400-2XXX (Long Reading Range) 0 5 10 15 20 5 10 15 20 cm 10 20 30 40 50 60 70 cm 0.35 mm (14 mils) ≥ 0.50 mm (20 mils) CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 "Pitch" angle = 0 ° "Skew" angle = 10 ° "Tilt" angle = 0 ° Code Resolution* = High - for 0.3 ...

  • Datalogic Scanning DS2400 - page 43

    DS2400 DA TA LOGIC 3.6 - Technic al Feat ures This page is i nt entionally lef t blank. ...

  • Datalogic Scanning DS2400 - page 44

    DA TA LOGIC DS2400 Technical Feat ures - 4.1 4 MAINTENA NCE 4.1 CLEA NING Clean the laser beam output window periodically for continued c orrect operation of the reader . Dust, dirt, etc. on the window m ay alter the reading perfor manc e. Repeat the operation frequently in particularly dirty envir onments . Use sof t mater ial and alcohol to clean ...

  • Datalogic Scanning DS2400 - page 45

    DS2400 DA TA LOGIC 4.2 - Technic al Feat ures This page is i nt entionally lef t blank. ...

  • Datalogic Scanning DS2400 - page 46

    DA TA LOGIC DS2400 Technical Feat ures - 5.1 5 TECHNICA L FEA TURES DS2400-1XXX DS 2400-2XXX ELECTR ICA L FEA TURES Input Power Supply volt age 10 to 30 Vdc Power consum pt ion max. 5 W Serial I n terfaces (depends on m odel) Main RS232; RS485 Ful l -dupl ex / Half -dupl ex; 20 m A C.L. (20 mA C. L. only with I NT-22 ac c essory) Aux iliary RS23 2 ...

  • Datalogic Scanning DS2400 - page 47

    DS2400 DA TA LOGIC 5.2 - Technic al Feat ures SOFTW A RE FEATURES READABLE C ODE SYMBOLOG IES • EAN/ UPC (includi ng A dd-on 2 and A dd-on 5) • Code 93 • 2/5 I nt erl eaved • Code 128 • Code 39 (Standard and Ful l A SCII) • EAN 128 • Codabar • Pharmac ode Other sym bologies avail abl e on reques t. Code Sele ction up t o six differe ...

Manufacturer Datalogic Scanning Category Barcode Reader

Documents that we receive from a manufacturer of a Datalogic Scanning DS2400 can be divided into several groups. They are, among others:
- Datalogic Scanning technical drawings
- DS2400 manuals
- Datalogic Scanning product data sheets
- information booklets
- or energy labels Datalogic Scanning DS2400
All of them are important, but the most important information from the point of view of use of the device are in the user manual Datalogic Scanning DS2400.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Datalogic Scanning DS2400, service manual, brief instructions and user manuals Datalogic Scanning DS2400. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Datalogic Scanning DS2400.

A complete manual for the device Datalogic Scanning DS2400, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Datalogic Scanning DS2400 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Datalogic Scanning DS2400.

A complete Datalogic Scanning manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Datalogic Scanning DS2400 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Datalogic Scanning DS2400, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Datalogic Scanning DS2400, that we can find in the current document
3. Tips how to use the basic functions of the device Datalogic Scanning DS2400 - which should help us in our first steps of using Datalogic Scanning DS2400
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Datalogic Scanning DS2400
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Datalogic Scanning DS2400 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Datalogic Scanning DS2400?

Use the form below

If you did not solve your problem by using a manual Datalogic Scanning DS2400, ask a question using the form below. If a user had a similar problem with Datalogic Scanning DS2400 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)