Summary
  • Omega OS950 - page 1

    www .omega.com e-mail: info@omega.com omega.com ® ® U ser’s Guide OS950 SERIES Handheld Infrared Thermometers Shop online at ...

  • Omega OS950 - page 2

    Servicing North America: USA: One Omega Drive, Box 4047 ISO 9001 Stamford CT 06907-0047 Certified T el: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1 T el: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: USA and Sales Service: 1-800-826 ...

  • Omega OS950 - page 3

    ...

  • Omega OS950 - page 4

    ...

  • Omega OS950 - page 5

    T able of Contents Chapter One - Welcome to Infrared Thermometry . . . .1 1.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . .1 1.2 Product Features . . . . . . . . . . . . . . . . . . . . . . .1 1.3 Models and Ordering Information . . . . . . . . . . .1 Chapter T wo - Operation . . . . . . . . . . . . . . . . . . . . . . .2 2.1 O ...

  • Omega OS950 - page 6

    Chapter One - Welcome to Infrared Thermometry 1.1 Introduction Omega Engineering, the world's leading manufacturer of infrared temperature systems, presents the low cost OS950™ Series of hand held infrared thermometers. These dual-purpose systems function as both NIST trace- able temperature calibrators and thermal scanning devices. Make fas ...

  • Omega OS950 - page 7

    OS956 0 to 1600°F (86 to 871°C) Unit includes a Remote Sensor , 9 V DC Alkaline Battery and OS950 Instruction Manual. Also available with an RS232 Digital Output and an Analog Output. Chapter T wo - Operation 2.1 OS950 Controls 2.2 T o Change Display Measurement Units The OS950 Models come from the factory displaying tem- perature in units of Fah ...

  • Omega OS950 - page 8

    The instrument now reads in °C instead of °F . T o return to the original setting, simply repeat the process. 2.3 T o Change Mode of Operation The OS950 Models come from the factory operating in the MAX mode. T o change to the SCAN mode perform the fol- lowing steps: 1. Remove the screw from the underside of the case. 2. Remove the cover , exposi ...

  • Omega OS950 - page 9

    2.4.2 T emperature Measurement of Moving T argets T o measure moving targets that are not possible to touch, use the following procedure: 1. Press and hold the MEASURE button. 2. The display will briefly show [8888]. 3. Bring the nosepiece as close as possible to the target, preferably within 1/32 inch (1 mm). ** 4. The display may or may not chang ...

  • Omega OS950 - page 10

    5. Record the temperature from the display . 6. Release the MEASURE button. The last reading will remain locked on the display for 10 seconds after releasing the button. 2.6 SCAN Mode T emperature Measurements Use this measurement mode for thermal scanning of a tar- get or when measuring targets located at a distance. The OS950 is a wide-angle ther ...

  • Omega OS950 - page 11

    3.2 Measuring Metallic T argets In general, infrared thermometers can easily measure non- metallic surfaces because they emit most of their potential heat. Metallic surfaces, on the other hand, are poor emit- ters and require special treatment before infrared ther- mometers can accurately measure their temperature. Fortunately , that special treatm ...

  • Omega OS950 - page 12

    heat. As long as the ice is not melting, the OS950 will accurately read its temperature. T o make an accurate target measurement, remove any ice or moisture before measuring. Chapter Four - Maintenance The high-performance OS950 is a rugged and durable instrument, designed for long term performance reliability . 4.1 Battery Replacement Open the ins ...

  • Omega OS950 - page 13

    If the [E-##] or [Err] error messages are displayed, the unit will not function and must be returned to the factory for repair . (See section on W arranty for return instruction). The following charts summarize the fault condition, and the associated indication. Model OS951 [LO] T arget < -50 °F (-45 °C) Contact Omega Model OS953 [LO] T arget ...

  • Omega OS950 - page 14

    5.2 T roubleshooting Measurement Difficulties If you experience measurement problems, review the fol- lowing troubleshooting steps: Is the sensor window clean? Clean the sensor window and reflective cup and repeat the measurement. Is the target's surface non-metallic? Coat metallic surfaces with a non-metallic finish and repeat the measurement ...

  • Omega OS950 - page 15

    Display Update 10 times/second Measurement Response Time Approximately 0.1 seconds Field of View 1:1 0.63" (15.9 mm) Diameter Spot Area in AECS Mode Spectral Sensitivity 2 to 20 microns Battery One 9 volt Battery Life 5000 readings (10 seconds each) Instrument Ambient T emperature Operating Range: 32 to 122°F (0 to 50°C) Storage Range: -22 t ...

  • Omega OS950 - page 16

    ...

  • Omega OS950 - page 17

    W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA ’s W ARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA ’s custome ...

  • Omega OS950 - page 18

    Where Do I Find Everything I Need for Process Measurement and Control? OM EGA…Of Course! Shop online at www .omega.com TEMPERATURE ✓ Thermocouple, R TD & Thermistor Probes, Connectors, Panels & Assemblies ✓ W ire: Thermocouple, R TD & Thermistor ✓ Calibrators & Ice Point References ✓ Recorders, Controllers & Process Mo ...

Manufacturer Omega Category Thermometer

Documents that we receive from a manufacturer of a Omega OS950 can be divided into several groups. They are, among others:
- Omega technical drawings
- OS950 manuals
- Omega product data sheets
- information booklets
- or energy labels Omega OS950
All of them are important, but the most important information from the point of view of use of the device are in the user manual Omega OS950.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Omega OS950, service manual, brief instructions and user manuals Omega OS950. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Omega OS950.

Similar manuals

A complete manual for the device Omega OS950, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Omega OS950 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Omega OS950.

A complete Omega manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Omega OS950 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Omega OS950, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Omega OS950, that we can find in the current document
3. Tips how to use the basic functions of the device Omega OS950 - which should help us in our first steps of using Omega OS950
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Omega OS950
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Omega OS950 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Omega OS950?

Use the form below

If you did not solve your problem by using a manual Omega OS950, ask a question using the form below. If a user had a similar problem with Omega OS950 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)