Manual Bloomfield 2272

26 pages 3.11 mb
Download

Go to site of 26

Summary
  • Bloomfield 2272 - page 1

    BLOO MFIEL D IND USTRI ES 2 ERIK CIRCLE, P .O .Box 280 V erd i, NV 89439 U.S.A. Custom er Service (775) 345- 0444 Ex t.502 fax ( 775) 34 5-0569 ww w .w el ls bl oom fi el d. co m OWNERS MANU AL LX DECANTER BREWER MODELS 2212 2216 2216EX 2272 2274EX Includes INSTALLAT ION OPERAT ION USE & CARE SERVICE p/n 74733 Rev. D M656 05 0208 cps 656 Model ...

  • Bloomfield 2272 - page 2

    All electrical equipment ma nufactured by BLOOMFIELD INDUSTRI ES is w arranted against d efects in m aterials and workmanship for a period of one year from the date of original installation or eighteen (18) months from the date of shipment from our factory, whichever comes first, and is for the benefi t of the original purchaser, except that: a. ai ...

  • Bloomfield 2272 - page 3

    ELECTRICAL SPECIFIC A TIONS* MODEL WAT TS VOLTS 1ø Hz CIRCUIT REQUIRED WIRE 2212 1800 120 50/60 15 AMP ( NEMA 5-15R ) 2 + ground 2216 3500 120/240 50/60 HARD WIRE TO CIRCUIT BREAKER 3 + ground 2272 1800 120 50/60 15 AMP ( NEMA 5-15R ) 2 + ground 2216EX 3500 240 50/60 HARD WIRE TO CIRCUIT BREAKER 2 + ground 2274EX 3500 240 50/60 HARD WIRE TO CIRCUI ...

  • Bloomfield 2272 - page 4

    FEATURES & OPERATING CONTROLS 1. Brew Indicator Glows during brew cycle, flas hes in “Brew W ait” 2. Heat Indicator Glows when heating elem ents are energized 3. Power Indicator Glows when power is on 4. Warmer Indicators Glow when individual warmers are turned on 5. Brew Key Press to initiate bre w cycle 6. Cancel Key Press to terminate br ...

  • Bloomfield 2272 - page 5

    PRECAUTIONS AND GENERAL INFORMATION WARNING: Electric Shock Hazard All servicing requiring access to non-insu lated components must be performed by qualified service personnel. Do not open any access panels w hich require the use of tools. Failure to heed this w arning c an resu lt in electrical shock . WA RNING : Injury Hazar d All installation pr ...

  • Bloomfield 2272 - page 6

    INSTALLATION INSTRUCTIONS RE A D THIS C A R EFULL Y BEFORE ST ARTING THE INST A LL A TION REFER TO EXPLODED VIEWS PAGES 16 thru 19 FOR COMPONENT NAMES/NUMBERS 1. Unpack the unit. Inspec t a ll components for comp leteness and condition. Ensure that all packing materials have been removed from the unit. 2. (See page 13.) Remove the Top W armer Unit ...

  • Bloomfield 2272 - page 7

    INSTALLATION INSTRUCTIONS (contin ued) NOTE: This equipment must be installed to comply with applica- ble f ederal, state and local codes and ordin a nc es. WARNING ELECTRIC SHOCK HAZARD: Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line will provide suc h a ground. Electrical shock will cause death or ...

  • Bloomfield 2272 - page 8

    OPERATION To over-ride th e Br ew Wait mode , press and hold the BR E W key for 3 second s when the brewer is in Brew Wait mode (i.e. when brew light is flashing). The brew will proceed immediatel y regardless of water temper ature. This f eature should onl y be used whe n testing water volume, otherwise the br ew will proceed with the water below ...

  • Bloomfield 2272 - page 9

    OPERATION (continued) WA R NI NG : Burn H azard. This applianc e dispenses very hot liquid. Serious bodily injury from scalding can occ ur from contact wi th dispensed liquids. CAUTION: Burn Hazard To avoid splashing or overflowing hot liqu ids, ALWAYS use an empty decanter before starting the brew cycle . Failure to comply can cause serio us burns ...

  • Bloomfield 2272 - page 10

    CLEANING INSTRUCTIONS CA UTI ON: Burn Hazard Brewing an d serving temperatures of coffee are extremely hot. Hot coffee will cause serious skin burns. CA UTIO N: Electric Shoc k Hazard Do not submerge or i mmerse brewer in wat er. Do not pour or splash water into o r over air vents, control panel or warmer plates. IMPORTANT: DO NOT use steel wool, s ...

  • Bloomfield 2272 - page 11

    A. Adjust Brew Time B. Adjust Brew Temperature C. Adjust Quality Timer D. Adjust Dripout Timer E. Adjust After Hours Timer AB CD E UNDE R TOP COVER (IN SECO NDS) BREW TIME R (IN °F) BREW TEMP (I N 5 MIN I NCR) QUALI TY TIM ER (IN SECONDS) DRIPOU T TIMER (IN ONE HR INCR) AFTER HOU RS T IMER WA TE R LEVEL PROBE TEMP PROBE 20 185 6 OFF 3 60 90 30 70 ...

  • Bloomfield 2272 - page 12

    SERVICING INSTRUCTIONS — ELECTRICAL OPERATION SEE PAGE 11 FOR COMPONENT NAMES / NUMBERS 1. Pressing the PO W ER key energizes the unit. The POWER LED will glow whenever the unit is ON . 2. Automatic fill is acco mplished via a FILL SOLENOID (32) and a W ATER LEVEL PROBE (7). The probe senses ground through the water in the tank. When the water le ...

  • Bloomfield 2272 - page 13

    27 28 WARM ER MOUN TI NG 3 5 4 20 32 18 7 8 15 17 4 E-MA XLX ELECT RICAL COMPONENT 12 0V UNITS 12 0/2 40V UNITS SERVICING INSTRUCTIONS — ELECTRICAL 3 PROBE, TEMPERATURE (THERMISTOR) 4 THERMOSTAT, HI-LIMIT 5 GROMMET 7 PROBE, WATER LEVEL 8 SLEEVE, WATER LE VEL PROBE 15 ELEMENT, W ATER HEATING 17 ASSEMBLY, TRIAC & HEAT SINK 18 BREW SOLENOID 2 ...

  • Bloomfield 2272 - page 14

    OPERATION SEE PAGE 13 FOR COMPONENT NAMES/NUMBERS 1. W ater enters at the inlet fi tting of the fill solenoid (32). The solenoid adm its water via a command from the controller. N OTE: The soleno id has an inter nal strainer. To clean the strainer: Shut off water supply. Unscrew the plastic cap protruding from the rear of the brewer. Remove the c a ...

  • Bloomfield 2272 - page 15

    SERVICING INSTRUCTIONS — PLUMBING 13 ITEM DESCRI PTION P ART N0. U SED ON 1 2 ASS E MBL Y , W A TER T ANK (120 V) 83500 2212, 22 72 6 GA SKE T , T AN K L ID 83 499 AL L 9 T ANK L ID 83 504 ALL 10 RET AINING CLIP , T ANK LID 83506 ALL 1 1 HOS E, OV ERFL O W (2 pc SILIC O NE 4.5” LO NG) 86014 ALL 12 HOSE , F AUCE T SUPPL Y (SIL ICONE, 10” LONG) ...

  • Bloomfield 2272 - page 16

    SERVICING INST RUCTIONS — DE-LIMING HEA TER TANK 1. Disconnect br ewer form the electrical sup pl y. Turn off the water suppl y and disc onnect water suppl y from the brewer inlet fitting. 2. Remove the top panel or top wa rmer section to gain access to internal components. 3. Disconnect water level sensor and w ater te mperature sensor from the ...

  • Bloomfield 2272 - page 17

    SERVICING INSTRUCTIO NS — DIAGNOSTICS & TROUBLESHOOTIN G) If the E-Max™ LX goes into an error mode as outlined below , it will probably be necessary to reset the bre w er in order to test individual components. Note the reset proce dure below : * FOR “LOW W ATER” OR “OVERHEAT” ERRORS: PRESS & HOLD CANCEL FOR 3 SECONDS, OR RE-ENE ...

  • Bloomfield 2272 - page 18

    EXPLODED VIEW — IN-LINE MODELS 16 ...

  • Bloomfield 2272 - page 19

    PARTS LIST — IN-LIN E MODELS 17 ...

  • Bloomfield 2272 - page 20

    EXPLODED VIEW — STEP-UP MODELS 18 ...

  • Bloomfield 2272 - page 21

    PA RTS LIST — STEP -UP M ODE L S 19 ...

  • Bloomfield 2272 - page 22

    WIRING DIAGRAM — IN-LINE MOD ELS 20 ...

  • Bloomfield 2272 - page 23

    WIRING DIAGRAM — I N-LINE EXPORT MODEL 21 ...

  • Bloomfield 2272 - page 24

    CONTROL BOARD 1 WP3 2 WP2 3 WP1 1 Heat er ( Line ) 2 Inlet ( Line) 3 Dump Line 4 Power (Line) 5 6 Dump (Neut) 7 Power (Neut) 8 Heater (Neut) Lin e Load Ga te Fr ont Wa rm er P late #2 120V 100 Watt Main Warme r P late 12 0V 100 Watt Rear War mer Pl ate #3 12 0V 100 Watt Out let Va l v e In let Va l v e 120 Volt 15 00 Wat t Ta n k H e a t e r Hi- Li ...

  • Bloomfield 2272 - page 25

    WIRING DIAGRAM — STEP-UP EXPORT MODEL 23 ...

  • Bloomfield 2272 - page 26

    Blo omfi eld Ind ustries , In c. Divis ion of Carri er Refrige r atio n In U S In C an ada PO Box 28 0, V e rdi, NV 89439 T el ephone: 775- 345-0444 Servi ce: 88 8-492-2782 Fax: 888-792-278 3 websit e: www . wellsbl oomfi eld.com T el ephone: 877- 507-1700 Servi ce: 90 5-507-1700 Fax: 905-507-1777 website: www .bl oomcan.com Bloomfi eld I ndustr ie ...

Manufacturer Bloomfield Category Coffeemaker

Documents that we receive from a manufacturer of a Bloomfield 2272 can be divided into several groups. They are, among others:
- Bloomfield technical drawings
- 2272 manuals
- Bloomfield product data sheets
- information booklets
- or energy labels Bloomfield 2272
All of them are important, but the most important information from the point of view of use of the device are in the user manual Bloomfield 2272.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Bloomfield 2272, service manual, brief instructions and user manuals Bloomfield 2272. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Bloomfield 2272.

Similar manuals

A complete manual for the device Bloomfield 2272, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Bloomfield 2272 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Bloomfield 2272.

A complete Bloomfield manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Bloomfield 2272 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Bloomfield 2272, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Bloomfield 2272, that we can find in the current document
3. Tips how to use the basic functions of the device Bloomfield 2272 - which should help us in our first steps of using Bloomfield 2272
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Bloomfield 2272
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Bloomfield 2272 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Bloomfield 2272?

Use the form below

If you did not solve your problem by using a manual Bloomfield 2272, ask a question using the form below. If a user had a similar problem with Bloomfield 2272 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)