Manual Fluke 50S

14 pages 0.15 mb
Download

Go to site of 14

Summary
  • Fluke 50S - page 1

    PN 1281009 October 1999 Rev.1, 3/ 03 ©1999- 2003 Fl uke C orporati on. All rig hts reserv ed. P rinted in U.S .A. All produc t nam es are tr adem arks of their res pecti ve compa nies. 1 50S & 50D Thermometer Calibration Informa tion W Warning These service instructions are fo r use by qua lified personnel only. To avoid electric shock, do not ...

  • Fluke 50S - page 2

    50S & 50D Thermomete r Calibration In formati on 2 In t e r n a t ion a l S y mbols Table 1 id entif ies the in ternat ional elect rical symbol s used in this d ocu ment. Table 1. Int ernational Electrical Symbols Used in t his Document N Low Battery Important informat ion Complies w ith relev ant Cana dian Standards Assoc iation direc tives Co ...

  • Fluke 50S - page 3

    Spec i ficat ions 3 Sp ecif i c a ti on s G ener a l Weight 280 g (10 oz) Dimensions (without hols ter) 2.8 cm × 7.5 c m × 16.6 cm (1.1 in × 3 i n × 6.6 in) Battery Standard 9 V battery (NEDA 1604, 6F22, or 006P) Protection Class III as defined in IEC 348, S afety Requirem ents for Elec tronic Appar atus Env i ronme n t a l Operating Tem peratu ...

  • Fluke 50S - page 4

    50S & 50D Thermomete r Calibration In formati on 4 Clean the thermo mete r case w ith a m ild de tergen t and wate r. The pca may be w ashed w ith iso propy l alcohol o r deion ozed wa ter and a soft brush. D ry the pca w ith clean dry air at low pressu re, the n bake it a t 50 o C for 24 hours. D i sassem b l y / Reass e m b l y Thermomet er d ...

  • Fluke 50S - page 5

    Basic Ma intena nce 5 Chang i ng t h e Bat t ery W Warning • Replace the battery as soon as the low battery indicator ( N ) a ppears. The possibility of false readings increases when the battery is not fully charged. False readings can lead to personal injury. • To avoid electrical shock, disconnect the thermocouple (s) before opening the case. ...

  • Fluke 50S - page 6

    50S & 50D Thermomete r Calibration In formati on 6 R e qui r e d T e s t Equipm e nt Table 2 list s the requ ired tes t equipm ent need ed to pe rform the perfo rmance test and ca libra tion proced ures for the 5 0S and 50D th ermo meters. I f the requi red equ ipment is not ava ilable, inst ruments wi th equivalen t specifica tions may be us e ...

  • Fluke 50S - page 7

    Perform ance Test s 7 K J MAX MIN HOLD REC C F 50S Display 50D Display - + T1 T2 T1-T2 K J HOLD C F - + zf03f. eps Figure 3. Display Seg ments W i d e Range Pe r f o r manc e Test Procedure This tes t veri fies the instrum ent sp ecif icatio ns. If the ins trumen t fails this tes t, perfor m the calib ration procedure. If the un it cont inutes to f ...

  • Fluke 50S - page 8

    50S & 50D Thermomete r Calibration In formati on 8 5520A Ice bath Thermocouple wire 50S or 50D Thermometer + _ Copper wire zf05f. eps Figure 4. Ice B ath Equipment Conne ctions Ic e B a t h T e st Use the fo llowing p rocedure to test the the rmomete r. This test sh ould be co nducted o n both th ermoc ouple inputs o f the 50D. 1. Connect the e ...

  • Fluke 50S - page 9

    Calibration 9 Table 3. Performance Test Values Thermocouple Input Voltage Display Reading Type (mV DC) o C o F K -5.587 -182.0 ± (0.9) -295.6 ± (1.6 ) K -3.211 -89.0 ± (0.8) - 128.2 ± (1. 4) K 21.919 530.0 ± (1.2) 986.0 ± (2.3 ) K 54.297 1355.0 ± (2.1) 2471.0 ± (3.8) J -7.824 -197.0 ± (1.0) -322.6 ± (1.7 ) J 13.997 258.0 ± (1.1) 496.4 ± ...

  • Fluke 50S - page 10

    50S & 50D Thermomete r Calibration In formati on 10 position unt il th e display i s locked in self-t est (all LCD segm ents on). Thi s ther mometer is now in the Reference Jun ction Sen sor ca libra tion mo de. Shorting o ut the V IEW sw itch grid turns o ff a fi lter so t hat the reading sta bi liz es im med ia tely. 13. Using the 80T -150U a ...

  • Fluke 50S - page 11

    Calibration 11 FLUKE 52-1601 zf09f. eps Figure 6. A1 Main PCA Adjus tments O pt i m i z i ng Th e rm o me t e r Pe r f o r mance i n t h e Negat i ve T e mper a t ur e Range Perfor m the fo llow ing step s to op timize the the rmome ter pe rform ance in the nega tive t emper ature ran ge: 1. Put the th ermome ter in n orma l operating mode. Nor mal ...

  • Fluke 50S - page 12

    50S & 50D Thermomete r Calibration In formati on 12 5. Allow th e system to stab ilize, then ad just T1 o r T2 offse t adjus tments fo r a te mperature display equ al to the read ing of the lag bath refer ence the rmomet er. 6. Calibra tion of the the rmome ters is com plete. D isconnec t all test e quipme nt fro m the instru ment. Lag bath (ro ...

  • Fluke 50S - page 13

    Replaceab le Par ts 13 R e p la c ea b l e P a rts Refer to T able 4 for a ll rep lacem ent part nu mbers and Figure 8 for par t location s. Unless specifie d in the “Model Nu mber” co lumn, a ll parts are fo r all u nits. To orde r replace able pa rts, se e the “Ser vice Cen ters” section of this manua l. Table 4. 50S and 50D Replace able ...

  • Fluke 50S - page 14

    50S & 50D Thermomete r Calibration In formati on 14 15 6 10 1 12 7 13 3 11 8 16 9 2X 4X 4X 4X 2 4 5 zf08f. eps Figure 8. Exploded Vi ew Diagram (Mod el 50D is Shown) ...

Manufacturer Fluke Category Thermometer

Documents that we receive from a manufacturer of a Fluke 50S can be divided into several groups. They are, among others:
- Fluke technical drawings
- 50S manuals
- Fluke product data sheets
- information booklets
- or energy labels Fluke 50S
All of them are important, but the most important information from the point of view of use of the device are in the user manual Fluke 50S.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Fluke 50S, service manual, brief instructions and user manuals Fluke 50S. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Fluke 50S.

Similar manuals

A complete manual for the device Fluke 50S, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Fluke 50S by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Fluke 50S.

A complete Fluke manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Fluke 50S - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Fluke 50S, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Fluke 50S, that we can find in the current document
3. Tips how to use the basic functions of the device Fluke 50S - which should help us in our first steps of using Fluke 50S
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Fluke 50S
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Fluke 50S in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Fluke 50S?

Use the form below

If you did not solve your problem by using a manual Fluke 50S, ask a question using the form below. If a user had a similar problem with Fluke 50S it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)