    ii L OCATIONS C ORPORATE H EADQUARTERS North America Metrologic Instru ments, Inc. Customer Servic e: 1-800-ID-METRO 90 Coles Road Tel: 856-228- 8100 Blackwood, NJ 0801 2-4683 Fax: 856-228-66 73 Email: info@metrologic.com Internet: www .metrologic.com E UROPEAN H EADQ UAR TER S Germany, Metrolog ic Instruments G mbH Tel: +49 (0) 89 89019 0 Middle E ...

  • Metrologic Instruments MS5100 - page 4

    iii T ABLE OF C ONTENTS Introducti on........................................................................................................... 1 Accessories and Supplies .................................................................................... 2 Quick St art............................................................................... ...

  • Metrologic Instruments MS5100 - page 5

    1 I NTRODUCTION The MS5145 Eclipse  is a singl e-line, hand-held laser scanne r. Equipped with Metrologic’s patented CodeGate  technol ogy, Eclipse  can be used in a wide variety of applications. Cod eGate technology allows the user to easily target the desired bar cod e and complete the data transmission with a simple press of a button. ...

  • Metrologic Instruments MS5100 - page 6

    2 A CCESSORIES AN D S UPPLIES The following is a list of parts that ma y or may not be included in the MS514 5 kit. • Eclipse  MS5145 Single-Line Las er Scanner • AC to DC Power Transformer – Regulated 5.2VDC @ 650 mA output • One of the following may be included: • 120 V United States [ MLPN 45-45593 ] • 220 V - 240 V Continental Eu ...

  • Metrologic Instruments MS5100 - page 7

    3 Q UICK S TART 1. Connect the 10-pin RJ45 plug into the j ack on the Eclipse  MS5145. You will hear a ‘click’ when the connectio n is made. 2. Connect the L-shaped plug of the po wer supply into the power jack on the PowerLink cable. 3. Connect the power supply into an AC o utlet. Make sur e the AC input requirements of the power supply mat ...

  • Metrologic Instruments MS5100 - page 8

    4 S TANDARD RS232 S CANNER I NSTALLATION 1. Turn off the host system. 2. Connect the 10-pin RJ45 plug of t he Po werLink cable into the jack on the MS5145 RS232 scanner. Note: If the MS5145 is receiving power from the host system, skip to step #5. (See caution statement below*) 3. Connect the L-shaped plug of the po wer supply into the power jack o ...

  • Metrologic Instruments MS5100 - page 9

    5 K EYBOARD W EDG E S CANNER I NSTALLATION 1. Turn off the host system. 2. Connect the 10-pin RJ45 plug of t he Po werLink cable into the jack on the MS5145. 3. Disconnect the keyboard from the host system. 4. Connect the L-shaped plug of the po wer supply into the power jack on the PowerLink cable ( refer to the manufacturer ’s recommendation an ...

  • Metrologic Instruments MS5100 - page 10

    6 K EYBOARD W EDG E I NSTALLATION ( CONTINUED ) Manufacturer’s Recommendation If the keyboard port of the host system cannot supply enough current, the use of an external power supply with the MS5145 Keybo ard W ed ge wil l be necessary. Powering the MS5145 directly from the computer keybo ard connector could interfere with the operation of the s ...

  • Metrologic Instruments MS5100 - page 11

    7 USB SCANNER I NSTALLATION 1. Connect the 10-pin RJ45 plug of t he Po werLink cable into the jack on the MS5145 USB scanner. Note: The MS5145 USB scanner will receive power directly fro m the host system; no external power supply is required. 2. Connect the USB connector of the Powe rLink cable into the USB port of the host system. 3. When the MS5 ...

  • Metrologic Instruments MS5100 - page 12

    8 D ISCONNECTING THE P OWER L INK C ABLE F ROM THE S CANNER Before removing the cable from the sca nner, Metrologic recomme nds that the power on the host system is off and the power supply has been discon nected from the PowerLink cable. 1. Locate the small ‘pin-hole’ on the back of the scanner. 2. Bend an ordinary pap erclip into the shape sh ...

  • Metrologic Instruments MS5100 - page 13

    9 S CANNER P ARTS 1. Green & Red LEDs The MS5145’s laser pulses on an d off when no bar code is presented, and stays on when it senses a bar code. The green LED remains o n dur ing normal pulse and scanning ope ration, and it blinks during power sav e mode. On a successful read of a bar code, the red LED will flash and th e scan ner will beep ...

  • Metrologic Instruments MS5100 - page 14

    10 A UDIBLE I NDICATORS When the MS5145 scanner is operatio nal, it provides audible feedback. T hese sounds indicate the status of the scann er. Eight settings are availa ble for the tone of the beep (normal, 6 alternate tones and n o tone). T o change the tone, refer to the Configuration Guide. One Beep – on pow er up The green LED will turn on ...

  • Metrologic Instruments MS5100 - page 15

    11 V ISUAL I NDICATO RS There is a red LED and a green LE D on the MS5145. When the scanner is on, the activity of the LEDs indicates the st atus of the current scan and the scanner. Green and Red LEDs are off The LEDs will not be illuminated if the scanner is not receiving power from the host or transformer. Steady Green Indicates normal pulse or ...

  • Metrologic Instruments MS5100 - page 16

    12 F AILURE M ODES One Razzberry Tone on Po wer-up This indicates the scanner has experi enced a laser or flipper subsystem failure. Return the un it for repair to a Metrologic Authorized Service Center. Continuous Razzberry Tone with all LEDs off If, upon power up, the scanner emits a continuous razzberry tone, then the scanner has an experienced ...

  • Metrologic Instruments MS5100 - page 17

    13 S CAN A REA Minimum Bar Code Element Width ABCDE F mm .10 .12 .17 .26 .33 .66 mils 4.1 4.8 6.8 10.4 13 26 ...

  • Metrologic Instruments MS5100 - page 18

    14 L ABELS Each scanner has one label on the unders ide of the unit. This label has the model number, date of manufacture, serial number, laser and caution information. The follo wing is an e xample of this l abel. Patent Information-See Manual FCC and ICES-003 Information-See Manua l Warranty VOID if case opened. Contains no user serviceable com p ...

  • Metrologic Instruments MS5100 - page 19

    15 T ROUBLESHOOTING G UIDE The following guide is for referenc e purp oses only . Contact a Metrologic representative to preserve the limite d warranty terms on page 31. S YMPTOM S P OSSIBLE C AUS E ( S )S OLUTION No LEDs, beep or laser line No power is being supplied to the scanner Check transformer, outlet and power strip. Make sure the cable is ...

  • Metrologic Instruments MS5100 - page 20

    16 T ROUBLESHOOTING G UIDE ( CONTINUED ) S YMPTOM S P OSSIBLE C AUS E ( S )S OLUTION The unit powers up, but does not scan Scanning a particular symbology that is not enabled UPC/EAN, Code 39, Interleaved 2 of 5, Code 93, Code 128 and Codabar are enabled by default. Verify that the type of bar code being read has been selected. The unit powers up, ...

  • Metrologic Instruments MS5100 - page 21

    17 T ROUBLESHOOTING G UIDE ( CONTINUED ) S YMPTOM S P OSSIBLE C AUS E ( S )S OLUTION Scanner beeps at some bar codes and NOT for others of the same bar code symbology The bar code may have been printed incorrectl y Check if it is a check digit/character/or border problem. Scanner beeps at some bar codes and NOT for others of the same bar code symbo ...

  • Metrologic Instruments MS5100 - page 22

    18 T ROUBLESHOOTING G UIDE ( CONTINUED ) S YMPTOM S P OSSIBLE C AUS E ( S )S OLUTION The unit is not transmitting each character (Keyboard Wedge) Configuration is not correct Increase interscan code delay setting. Adjust whether the F0 break is transmitted. It may be necessary to try this in both settings. Alpha characters show as lower case (Keybo ...

  • Metrologic Instruments MS5100 - page 23

    19 RS-232 D EMONSTRATION P ROGRAM If an RS-232 scanner is not communicating with your IBM compatible PC, key in the following BASIC program to test that the communication port and scanner are working. This program is for demonstration purposes only. It is only intended to prove that cabling is correct, the communi cation port is working, and the sc ...

  • Metrologic Instruments MS5100 - page 24

    20 A PPENDIX A Specifications O PERATIONAL Light Source Visible Laser Diode 650 nm ± 1 0 nm Laser Power (peak) <1.0 mW Depth of Scan Field (for 13mil at Default) 0 mm – 140 mm (0” – 5.5”) Scan Speed 72 ± 2 scan lines per second Scan Pattern Single scan line Minimum Bar Width 0.102 mm (4.0 mil) Decode Capabilit y Autodiscriminates all s ...

  • Metrologic Instruments MS5100 - page 25

    21 A PPENDIX A ( CONTINUED ) E LECTRICAL Input Voltage 5 VDC ± 0.25 V Power - Operating 0.675 mW Current - Operating 135 mA peak @ 5 VDC DC Transformers Class 2; 5.2 V @ 650 mA UL UL listed for US and Canada; UL 60950, C22.2 No. 60950 Laser Class CDRH: Class II; IEC 60825-1: 1993+A1:1997+A2:2001 C lass 1 EMC Class B: FCC Part 15, ICES-003, Europea ...

  • Metrologic Instruments MS5100 - page 26

    22 A PPENDIX B Default Settings Many functions of the scanner can be “progra mmed” – that is, enabled o r disabled. The scanner is shipped from the factory programmed to a set of default conditions. The default parameter of the scanner has an asterisk (*) in the charts on the following pages. If an asterisk is not in the default column then t ...

  • Metrologic Instruments MS5100 - page 27

    23 A PPENDIX B ( CONTINUED ) Parameter Default OCIA RS232 Light Pen IBM 46XX KBW USB Paraf Support ITF 9 9 9999 ITF Symbol Lengths Variable 9 9 9999 Minimum Symbol Length 3 9 9 9999 Symbol Length Lock None 9 9 9999 Bars High as Code 39 * 9 Spaces High as Code 39 9 Bars High as Scanned 9 Spaces High as Scanned 9 Low Speed Option 9 Toggle on Decode 9 ...

  • Metrologic Instruments MS5100 - page 28

    24 A PPENDIX B ( CONTINUED ) Parameter Default OCIA RS232 Light Pen IBM 46XX KBW USB Inter-character delay Programmable in 1 msec steps (max 255 msecs) 1 msecs 10 msecs in KBW 9 9 999 Transmit UPC-A check digit * 9 9 9999 Transmit UPC-E check digit 9 9 9999 Expand UPC-E 9 9 9999 Convert UPC-A to EAN-13 9 9 9999 Transmit lead z ero on UPC-E 9 9 9999 ...

  • Metrologic Instruments MS5100 - page 29

    25 A PPENDIX B ( CONTINUED ) Parameter Default OCIA RS232 Light Pen IBM 46XX KBW USB Carriage Return * 99 9 Line Feed-Disabled by def ault in KBW * 99 Tab Prefix 99 Tab Suffix 99 “C” prefix 99 “I” prefix 99 STX prefix 99 ETX suffix 99 9 “DE” Disable Command 9 “FL” Laser Commands 9 DTR Handshaking support 9 RTS/CTS Handshaking 9 Char ...

  • Metrologic Instruments MS5100 - page 30

    26 A PPENDIX B (C ONTINUED ) Parameter Default OCIA RS232 Light Pen IBM 46XX KBW USB Coupon Code 128 99 As Code 39 999 Programmable Code Lengths 7 avail 9 9 9999 Programmable Suffix Characters 10 avail 99 9 Prefixes for Individual Code types 99 9 Inter Scan-Code Delay Programmable (100 µsec steps) 800 µsec 9 Function/Control Key Support 99 Minimu ...

  • Metrologic Instruments MS5100 - page 31

    27 A PPENDIX C Scanner Pinout Connections MS5145-41 (RS-232C & LTPN) Pin Function 1 Ground 2 RS-232 Transmit Output 3 RS-232 Receive Input ...

  • Metrologic Instruments MS5100 - page 32

    28 A PPENDIX C ( CONTINUED ) MS5145-37 (USB/KBW) Pin Function 1 Ground 2D - 3D + 4 PC DATA 5 PC CLOCK 6 KB CLOCK 7 PC+5V/V_USB 8 KB DATA 9V _ E X T 10 Shield Ground Cable Connector Configurations • RS232 PowerLin k Cable with built in power jack [ MLPN 55-55000A ] The RS232 PowerLink cable is termin ated with a 9-pin D-Type connector to the host. ...

  • Metrologic Instruments MS5100 - page 33

    29 A PPENDIX C ( CONTINUED ) • Keyboard Wedge Po werLink and Adapter Cable [MLPN 55-55002A] The Keyboard Wedge PowerLink cable is a “Y” ca ble termi nated with a 5-pin DIN female connector on one end, and a 6-pi n mini DIN male on the other. Metrologic will supply an adapter cable with a 5-pin DIN male connector on one end and a 6-pin mini DI ...

  • Metrologic Instruments MS5100 - page 34

    30 A PPENDIX C ( CONTINUED ) • USB PowerLink cable [ MLPN 55-55165A ] The USB PowerLink cable is terminated with an USB A type connector. USB PowerLink cable Pin Function 1 PC+ 5V/V_USB 2D - 3D + 4 G round USB A Ty pe Connector ...

  • Metrologic Instruments MS5100 - page 35

    31 A PPENDIX D Warranty and Disclaimer Limited Warranty The MS5145 scanner is manufactured by Metrol ogic at its Suzhou, China facility. The MS5145 scanners have a two (2) year limited warranty from th e date of manufacture. Metrologic warrants and represents that all MS5100 scanners are free of all defects in material, workmanship and design, and ...

  • Metrologic Instruments MS5100 - page 36

    32 A PPENDIX E Notice This equipment has been tested and found to comply w ith the limits for a Class B digital device, pursuant to Part 15 o f the FCC rules. These limit s are desig ned to provide rea sonable protection against harmful interference in a residential installation. This equipment g enerates, uses and can radiate radio frequency and, ...

  • Metrologic Instruments MS5100 - page 37

    33 A PPENDIX F Patent Information “This METROLOGIC product may be cover ed by one or more of the follo wing U.S. Patents: U.S. Patent No.; 5,260,553; 5,340,971; 5,424,525; 5,484,992; 5,525,789; 5,52 8,024; 5,616,908; 5,627,359; 5,661,292; 5,777,315; 5,789,730; 5,789,731; 5,811,780; 5,828,048; 5,925,870; 6,029,894; 6,209,789; 6,227,450; 6,283,375; ...

  • Metrologic Instruments MS5100 - page 38

    34 I NDEX A AC input/outlet ................... 2, 3, 4, 6 Accessori es ................................... 2 Approvals ........................ 13, 20, 30 Assignments pin ...................... 2, 4, 6, 7, 26, 27 Audible .............................. 9, 11, 19 Autodiscrim inates ........................ 19 B Bar code ... 1, 3, 8-10, 15, 16, 18, 1 ...

  • Metrologic Instruments MS5100 - page 39

    35 I NDEX P Parts .......................................... 2, 8 Power supply ............... 3, 4, 6, 7, 26 Programming modes ......... 3, 17, 18 Q Quick start ..................................... 3 R Razzberry tone ............ 9, 10, 11, 22 Red LED .................. 3, 4, 6, 8, 9, 10 Repair .................................... 11, 28 RMA .... ...

  • Metrologic Instruments MS5100 - page 40

    June 2002 70 - 79001 B ...

Manufacturer Metrologic Instruments Category Scanner

Documents that we receive from a manufacturer of a Metrologic Instruments MS5100 can be divided into several groups. They are, among others:
- Metrologic Instruments technical drawings
- MS5100 manuals
- Metrologic Instruments product data sheets
- information booklets
- or energy labels Metrologic Instruments MS5100
All of them are important, but the most important information from the point of view of use of the device are in the user manual Metrologic Instruments MS5100.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Metrologic Instruments MS5100, service manual, brief instructions and user manuals Metrologic Instruments MS5100. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Metrologic Instruments MS5100.

A complete manual for the device Metrologic Instruments MS5100, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Metrologic Instruments MS5100 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Metrologic Instruments MS5100.

A complete Metrologic Instruments manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Metrologic Instruments MS5100 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Metrologic Instruments MS5100, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Metrologic Instruments MS5100, that we can find in the current document
3. Tips how to use the basic functions of the device Metrologic Instruments MS5100 - which should help us in our first steps of using Metrologic Instruments MS5100
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Metrologic Instruments MS5100
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Metrologic Instruments MS5100 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Metrologic Instruments MS5100?

Use the form below

If you did not solve your problem by using a manual Metrologic Instruments MS5100, ask a question using the form below. If a user had a similar problem with Metrologic Instruments MS5100 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)