Manual Lopi Leyden Pellet Stove

42 pages 2.24 mb
Download

Go to site of 42

Summary
  • Lopi Leyden Pellet Stove - page 1

    Leyden Pellet Stove • Horizontal Or Vertical Vent • Freestanding Stove • Mobile Home Approved • Class A Chimney Retrofit • Hearth Stove into Existing Masonry Chimney , Masonry Fireplace, or Z.C. Fireplace Tested and Listed by Omni-Test Laboratories, Inc. Beaverton, Oregon Report # 028-S-77-2 ASTM E1509-2004 - - Please read this entire man ...

  • Lopi Leyden Pellet Stove - page 2

    2 Introduction Travis Industries 4061016 100-01184 Introduction Congratulations! You have just purchased one of the finest hearth products on the market. Lopi heating appliances are solidly crafted and uniquely designed for the American lifestyle and proudly built in the U.S.A. Lopi wood, gas and pellet stoves, fireplaces and inserts have been Amer ...

  • Lopi Leyden Pellet Stove - page 3

    Table of Contents 3 Travis Industries 4061016 100-01184 Introduction Introduction ......................................................2 Important Information .........................................2 Safety Precautions Safety Precautions ............................................4 Specifications Heating Specifications ......................... ...

  • Lopi Leyden Pellet Stove - page 4

    4 Safety Precautions Travis Industries 4061016 100-01184 • Do not operate the heater if you smell smoke coming from the heater. Turn the M ODE switch to "OFF", monitor your heater, and call your dealer. Ok • Contact your local building officials to obtain a permit and information on any installation restrictions or inspection requirem ...

  • Lopi Leyden Pellet Stove - page 5

    Safety Precautions 5 Travis Industries 4061016 100-01184 • The heater will not operate during a power outage. If a power outage does occur, check the heater for smoke spillage and open a window if any smoke spills into the room. • This heater must be connected to a standard 115 V., 60 Hz grounded electrical outlet. Do not use an adapter plug or ...

  • Lopi Leyden Pellet Stove - page 6

    6 Specifications Travis Industries 4061016 100-01184 Heating Specifications Approximate Maximum Heating Capacity (in square feet)* ........................................ 800 to 2,250 Sq. Feet Burn Rate (Pounds per Hour)** ............................................................................ 1.7 to 5.5 Maximum Burn Time on Low Burn** ...... ...

  • Lopi Leyden Pellet Stove - page 7

    Installation (For Qualified Installers Only) 7 Travis Industries 4061016 100-01184 Before You Begin READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE THIS HEATER. FAILURE TO FOLLOW THE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. Check with local building officials for any permits required for installation of this pell ...

  • Lopi Leyden Pellet Stove - page 8

    8 Installation (For Qualified Installers Only) Travis Industries 4061016 100-01184 Clearances - Straight Installation 7 ” Minimum 6 ” Minimum 3 ” Minimum 2 ” Minimum “ Tee ” 3 ” Minimum 7 ” Minimum Through the Wall Installations Interior Vertical Vents Floor Protection 6 ” Minimum Clearances - Corner Installation Through the Wall ...

  • Lopi Leyden Pellet Stove - page 9

    Installation (For Qualified Installers Only) 9 Travis Industries 4061016 100-01184 Venting the Pellet Stove • PELLET VENT MUST MAINTAIN A MINIMUM 3" CLEARANCE TO ANY COMBUSTIBLE (INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER). • DO NOT CONNECT THE PELLET VENT TO A VENT SERVING ANY OTHER APPLIANCE OR STOVE. • DO NOT INSTAL ...

  • Lopi Leyden Pellet Stove - page 10

    10 Installation (For Qualified Installers Only) Travis Industries 4061016 100-01184 Pellet Vent Type • Must be 4" diameter Type "L" (except for masonry fireplace installations) - or - connect the vent to a factory built type "A" chimney. All vent joints (including adapters, elbows, etc … ) must be sealed with 500 ° F. ...

  • Lopi Leyden Pellet Stove - page 11

    Installation (For Qualified Installers Only) 11 Travis Industries 4061016 100-01184 Mobile Home Requirements • Outside air is required (used for combustion) - see the directions below. • The heater must be bolted to the floor (Some states do not require this; check with your local building department). See the illustration to the right. • The ...

  • Lopi Leyden Pellet Stove - page 12

    12 Installation (For Qualified Installers Only) Travis Industries 4061016 100-01184 Alcove Installation Requirements When the pellet stove is placed in a location where the ceiling height is less than 7' tall, it is considered an alcove installation. Because of the reduced height, the requirements listed below must be met. • Minimum height i ...

  • Lopi Leyden Pellet Stove - page 13

    Installation (For Qualified Installers Only) 13 Travis Industries 4061016 100-01184 Thermostat Installation ! Do not connect 120 VAC to the thermostat circuit of this heater (do not use a household thermostat used for a wall-board or other electical heater). A thermostat is included with this heater (part # 99300650). Follow the directions below to ...

  • Lopi Leyden Pellet Stove - page 14

    14 Installation (For Qualified Installers Only) Travis Industries 4061016 100-01184 Installation Example: Direct "Through-the-wall" Installation Floor Protection House Shield (used to protect exterior wall from soot discoloration) is HIGHLY RECOMMENDED 12 ” Minimum Horizontal Rain Cap Wall Thimble (note 3 ” clearance between vent and ...

  • Lopi Leyden Pellet Stove - page 15

    Installation (For Qualified Installers Only) 15 Travis Industries 4061016 100-01184 Installation Example: Interior Vertical Installation Floor Protection 24 ” Minimum Insulation must maintain 3 ” clearance. Outside air may be drawn from a ventilated crawl space. 2 ” Min. 3 ” Min. Ceiling Support / Fire Stop Spacer Roof Flashing Storm Collar ...

  • Lopi Leyden Pellet Stove - page 16

    16 Installation (For Qualified Installers Only) Travis Industries 4061016 100-01184 Installation Example: Class A Chimney Retrofit Floor Protection Outside air may be drawn from a ventilated crawl space. 2 ” Min. 3 ” Min. Class A Chimney Ceiling Support Roof Flashing “ L ” Vent to Class A Chimney Adapter Class A Chimney “ L ” Vent Storm ...

  • Lopi Leyden Pellet Stove - page 17

    Installation (For Qualified Installers Only) 17 Travis Industries 4061016 100-01184 Installation Example: Masonry Fireplace Hearth Stove “ L ” Vent Flex Section Outside air may be drawn from the ash cleanout. 6 ” Min. “ L ” Vent Storm Collar Vertical Cap Cover Plate (non-combustible) Silicone Seal the cover plate with silicone. NOTE: you ...

  • Lopi Leyden Pellet Stove - page 18

    18 Installation (For Qualified Installers Only) Travis Industries 4061016 100-01184 In s t al l at i o n E x am p l e: Z er o -Cl ear an c e (M et al ) F i r ep l ac e H ear t h S t o v e “ L ” Vent Flex Section 6 ” Min. “ L ” Vent Storm Collar Vertical Cap Cover Plate (non-combustible) Silicone Seal the cover plate with silicone. NOTE: y ...

  • Lopi Leyden Pellet Stove - page 19

    Installation (For Qualified Installers Only) 19 Travis Industries 4061016 100-01184 Installation Example: Freestanding Masonry Chimney 6 ” Min. Allow room for the hopper lid to open 44 ” “ L ” Vent Sections “ L ” Vent Storm Collar Vertical Cap Cover Plate (non-combustible) Silicone Seal the cover plate with silicone. 3 ” Minimum Clean ...

  • Lopi Leyden Pellet Stove - page 20

    20 Operation Travis Industries 4061016 100-01184 Safety Notice Read this entire manual (especially the "Safety Precautions" on pages 4 and 5) before using this stove. Failure to follow the instructions may result in property damage, bodily injury, or even death. ! Do not unplug the stove to turn it off. This stove relies upon electricity ...

  • Lopi Leyden Pellet Stove - page 21

    Operation 21 Travis Industries 4061016 100-01184 Loading Pellets Lift the hopper lid to its vertical position. Pour pellets into the hopper until full. NOTE: The hopper holds approximately 50 pounds of pellets. To Open the Hopper Lid: Lift the hopper lid from this handle. Warning: The front edge of the stove top becomes very hot, do not touch this ...

  • Lopi Leyden Pellet Stove - page 22

    22 Operation Travis Industries 4061016 100-01184 Manual Mode Manual mode requires the user to turn the heater on and off manually. To Start Press the "Manual Start" button. That's it. The stove automatically goes to a medium burn rate and high fan while the igniter starts the fire burning within 10 minutes. During this period the low ...

  • Lopi Leyden Pellet Stove - page 23

    Operation 23 Travis Industries 4061016 100-01184 Auto Mode Auto mode allows you to use a thermostat to control room temperature. The stove automatically turns on when the temperature drops below the thermostat setting. Once the stove reaches operating temperature, the stove then runs at the heat output setting selected. To Adjust Room Temperature ( ...

  • Lopi Leyden Pellet Stove - page 24

    24 Operation Travis Industries 4061016 100-01184 Restrictor Adjustment The restrictor “ fine tunes ” your appliance, adjusting the amount of air flowing to the flame. NOTE : the optimal restrictor position will vary over time as soot builds up inside the exhaust system. Not Enough Air If clinkers (ashes that solidify into a clump) develop or th ...

  • Lopi Leyden Pellet Stove - page 25

    Operation 25 Travis Industries 4061016 100-01184 Start-Up Sequence This stove utilizes a start-up sequence whenever the mode switch is changed or the heater is started when cold. This is to ensure proper operation through all possible settings and operational states (hot or cold, pellets burning or not burning, etc.). This sequence over-rides all u ...

  • Lopi Leyden Pellet Stove - page 26

    26 Operation Travis Industries 4061016 100-01184 Using a Pellet/Corn Mix with This Heater This heater may burn a mixture of corn and wood pellets up to a 50% - 50% proportion by volume. Shelled corn burned in Travis pellet appliances must be clean (free of husk and cob residue) and have a moisture content no greater than 15%. DO NOT BURN A MIX WITH ...

  • Lopi Leyden Pellet Stove - page 27

    Maintenance 27 Travis Industries 4061016 100-01184 Daily Maintenance (whenever using the stove) Inspect the Burn When burning on high, the flames should be bright orange with embers jumping from the firepot. NOTE : the optimal restrictor position will vary over time as soot builds up inside the exhaust system. See "Restrictor Adjustment" ...

  • Lopi Leyden Pellet Stove - page 28

    28 Maintenance Travis Industries 4061016 100-01184 Daily Maintenance (whenever using the stove) - Continued Check Firepot for Clinkers If the flames seem to be coming only from the sides, or are orange/black, turn the heater off and check for clinkers (ashes that solidify into a clump). The most likely causes are: • Restrictor needs adjustment (s ...

  • Lopi Leyden Pellet Stove - page 29

    Maintenance 29 Travis Industries 4061016 100-01184 Daily Maintenance (whenever using the stove) - Continued Door Opening WARNING : Make sure the heater has fully cooled (approximately 25 minutes) before opening the door and conducting service. Open the latch. WARNING : Do not swing the doors past 90 ° . This may cause the doors to strike the body ...

  • Lopi Leyden Pellet Stove - page 30

    32 Maintenance Travis Industries 4061016 100-01184 Bi-Weekly Maintenance (or every 10 bags of pellets) Flyash Removal This heater was designed to allow for easy flyash removal with the included tools. However, to ease maintenance, several pellet stove owners have purchased vacuums specifically made to remove flyash. Furthermore, some of these vacuu ...

  • Lopi Leyden Pellet Stove - page 31

    Maintenance 31 Travis Industries 4061016 100-01184 Bi-Weekly Maintenance (or every 10 bags of pellets) - continued Clean the Baffles WARNING : Make sure the heater has fully cooled (approximately 25 minutes) before conducting service. HINT : The more often you clean out flyash, the more efficient your heater will burn. The baffles are found along t ...

  • Lopi Leyden Pellet Stove - page 32

    32 Maintenance Travis Industries 4061016 100-01184 Bi-Weekly Maintenance (or every 10 bags of pellets) - continued Sweep Ash Into Ashpan WARNING : Make sure the heater has fully cooled (approximately 25 minutes) before conducting service. Remove the two ashdump covers on the floor of the firebox using the included hook tool. Remove the firepot and ...

  • Lopi Leyden Pellet Stove - page 33

    Maintenance 33 Travis Industries 4061016 100-01184 Bi-Weekly Maintenance (or every 10 bags of pellets) - continued Check Ashpan, Dispose if necessary WARNING : Make sure the heater has fully cooled (approximately 25 minutes) before conducting service. WARNING : The ashpan must be in place while the heater is in use. Twist the ashpan handle clockwis ...

  • Lopi Leyden Pellet Stove - page 34

    34 Maintenance Travis Industries 4061016 100-01184 Yearly Maintenance (or every two tons) The following section details extensive maintenance procedures. We strongly suggest these items be carried out by a trained service technician, possibly by a service agreement set up with your dealer. WARNING: Disconnect the power cord and make sure the heater ...

  • Lopi Leyden Pellet Stove - page 35

    Maintenance 35 Travis Industries 4061016 100-01184 Yearly Maintenance (or every two tons) - continued Remove the button plugs at the top of the firebox (both sides). Once removed, use the bottle brush to dislodge any flyash from the exhaust channel behind the button plug. Use the included bottle brush to remove accumulated flyash from the vertical ...

  • Lopi Leyden Pellet Stove - page 36

    36 Maintenance Travis Industries 4061016 100-01184 Yearly Maintenance (or every two tons) - continued Clean the Exhaust Blower The exhaust blower cover is held in place with 4 screws. Remove the cover plate on the exhaust blower. Clean the area inside the blower, removing all flyash. Flow Switch Tube Nipple (attached to exhaust channel) Remove the ...

  • Lopi Leyden Pellet Stove - page 37

    Maintenance 37 Travis Industries 4061016 100-01184 Yearly Maintenance (or every two tons) - continued Clean the Convection Blower Remove all dust and debris from the convection blower. Take care to prevent damage to the convection blower impellers. Clean the Vent Check the vent sections for creosote accumulation (indicating a poorly burning stove). ...

  • Lopi Leyden Pellet Stove - page 38

    38 Maintenance Travis Industries 4061016 100-01184 Replacement Parts Door Replacement Parts 5 9 8 10 4 3 7 2 6 1 ID # Description Qty Part # ID # Description Qty Part # 1 Door, Left 1 2 Door, Right 1 3 Door Gasket 1 4 Gasket Cement 1 5 Glass Gasket 1 6 Glass 2 7 Glass Clip w Screws, Gasket 4 8 Door Hinge w Pins 4 9 Left Door Handle w Hardware 1 1 0 ...

  • Lopi Leyden Pellet Stove - page 39

    Normal Operating Sounds 39 Travis Industries 4061016 100-01184 Auger Motor When feeding pellets, you may hear the intermittent buzz of this motor running. Heat Exchanger Tubes You may hear the heated air being forced through these tubes by the convection fan. Firepot As pellets are fed into the firepot, a light clicking sound may be heard. Convecti ...

  • Lopi Leyden Pellet Stove - page 40

    40 Safety Label Travis Industries 4061016 100-01184 ...

  • Lopi Leyden Pellet Stove - page 41

    Limited 7 Year Warranty 43 Travis Industries 4061016 100-01184 To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclosed warranty card and mail it within ten (10) days of the appliance purchase date to: TRAVIS INDUSTRIES, INC., 4800 Harbour Pointe Blvd. SW, Mukilteo, WA 98275. TRAVIS INDUSTRIES, INC. warrants this appliance (a ...

  • Lopi Leyden Pellet Stove - page 42

    42 Index Travis Industries 4061016 100-01184 "AUGER ON" Light ..............................................2 5 "FAULT" Light ....................................................2 5 "MANUAL AUGER" Button ....................................2 5 Adjusting the Door Hinge and Latch .......................3 7 Adjusting the ...

Manufacturer Lopi Category Stove

Documents that we receive from a manufacturer of a Lopi Leyden Pellet Stove can be divided into several groups. They are, among others:
- Lopi technical drawings
- Leyden Pellet Stove manuals
- Lopi product data sheets
- information booklets
- or energy labels Lopi Leyden Pellet Stove
All of them are important, but the most important information from the point of view of use of the device are in the user manual Lopi Leyden Pellet Stove.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Lopi Leyden Pellet Stove, service manual, brief instructions and user manuals Lopi Leyden Pellet Stove. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Lopi Leyden Pellet Stove.

A complete manual for the device Lopi Leyden Pellet Stove, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Lopi Leyden Pellet Stove by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Lopi Leyden Pellet Stove.

A complete Lopi manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Lopi Leyden Pellet Stove - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Lopi Leyden Pellet Stove, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Lopi Leyden Pellet Stove, that we can find in the current document
3. Tips how to use the basic functions of the device Lopi Leyden Pellet Stove - which should help us in our first steps of using Lopi Leyden Pellet Stove
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Lopi Leyden Pellet Stove
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Lopi Leyden Pellet Stove in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Lopi Leyden Pellet Stove?

Use the form below

If you did not solve your problem by using a manual Lopi Leyden Pellet Stove, ask a question using the form below. If a user had a similar problem with Lopi Leyden Pellet Stove it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)