Adder Technology AV Series - page 1
AdderLink A V series Digital Signage Extenders TRANSMITTER LINK 2 LINK 3 LINK 4 1 0 4 ADDERLINK I N I N ...
-
Adder Technology AV Series - page 2
1 SECT 1 Contents W elcome Introduction ................................................................................. 2 Standard AdderLink A V models ...................... ...
-
Adder Technology AV Series - page 3
2 SECT 2 W elcome Intr oduction The AdderLink A V range of digital signage extenders are designed and built specically for use wherever high quality video and sound must be ...
-
Adder Technology AV Series - page 4
3 AdderLink A V200 pair The AdderLink A V200 transmitter and receiver pair operate in a similar manner to the A V100 series, with the addition of an RS232 serial port. The seri ...
-
Adder Technology AV Series - page 5
4 F urther expansion T ransmitter cascading As mentioned earlier , the A V100, A V104 and A V200 transmitters are all capable of supporting additional transmitter modules (and ...
-
Adder Technology AV Series - page 6
5 For each A V module: Power supply adapter and country-specic mains cable Self adhesive rubber feet Video cable to connect a transmitter to the source PC and optionally to ...
-
Adder Technology AV Series - page 7
6 RECEIVER SKEW GB SKEW RG BRIGHT SHARP LIN K OUT 1 0 1 ADDERLINK O U T O U T M odule features TRANSMITTER LINK 2 LINK 3 LINK 4 1 04 ADDERLINK I N I N T ransmitter module (A V1 ...
-
Adder Technology AV Series - page 8
7 I nstallation Locations Please consider the following important points when planning the positions of your AdderLink A V modules: • T ake care not to exceed the maximum lin ...
-
Adder Technology AV Series - page 9
8 U sing the rear mounting slot The slot at the rear of each module allows it to be hung upon a xed scr ew that protrudes fr om the mounting surface. IMPORT ANT : The intern ...
-
Adder Technology AV Series - page 10
9 U sing the optional rack mount chassis 1 Place the optional rack plate onto the front of the transmitter or receiver module and secure it with the countersunk scr ews. 2 Orie ...
-
Adder Technology AV Series - page 11
10 Making standar d connections Connections to the AdderLink A V modules do not need to follow the precise order given in this user guide although it is r ecommended that you d ...
-
Adder Technology AV Series - page 12
11 T o connect the link cable(s) The links between the transmitter and r eceiver modules are made using between one and four twisted pair cables, specied to Category 5 or hi ...
-
Adder Technology AV Series - page 13
12 T o connect the power supply NOTE: Please read and adhere to the electrical safety information given within the Safety information section of this guide. In particular , do ...
-
Adder Technology AV Series - page 14
13 Link in The link from the transmitter to each r eceiver module is made using a twisted pair cable, specied to Category 5 or higher . When a single receiver is attached to ...
-
Adder Technology AV Series - page 15
14 RECEIVER SKEW GB SKEW RG BRIGHT SHARP 200 ADDERLINK O U T O U T T o connect the power supply NOTE: Please read and adhere to the electrical safety information given within t ...
-
Adder Technology AV Series - page 16
15 Making cascade connections The AdderLink A V series of products have been specically designed to be exible in order to support both your immediate and futur e needs fo ...
-
Adder Technology AV Series - page 17
16 Cascading transmitters Expansion at the transmitter end is achieved using the video and audio output ports. The signals from these ports ar e connected to the video and audi ...
-
Adder Technology AV Series - page 18
17 Cascading r eceivers (A dderLink A V101 only) Expansion at the receiver end is made possible using the LINK OUT ports present on AdderLink A V101 receivers. Receiver cascade ...
-
Adder Technology AV Series - page 19
18 Operation In operation, the AdderLink A V modules are designed to be completely transparent - high quality video and audio fr om the source PC system ar e played as normal, ...
-
Adder Technology AV Series - page 20
19 S kew compensation adjustments (A V101 & A V200 only) The twisted pair cabling used to link the AdderLink A V modules consists of four pairs of wires per cable. Three of ...
-
Adder Technology AV Series - page 21
20 T o zero the skew adjustment dials When supplied, the two skew dials are set in their neutral positions. i.e. no delay to either of its colours. However , if the module has ...
-
Adder Technology AV Series - page 22
21 F ur ther infor mation T roubleshooting If you experience problems when installing or using the AdderLink A V modules, please check through this section for a possible solut ...
-
Adder Technology AV Series - page 23
22 Safety infor mation • For use in dry , oil free indoor envir onments only . • Do not use to link between buildings. • Not suitable for use in hazardous or explosive en ...
-
Adder Technology AV Series - page 24
23 P roducts in the AdderLink A V range The following items are available within the AdderLink A V product range: • AdderLink AV100 pair (part number: ALA V100P) One AdderLin ...
-
Adder Technology AV Series - page 25
24 Emissions and I mmunity A Category 5 (or better) twisted pair cable must be used to connect the modules in order to maintain compliance with radio fr equency energy emission ...
-
Adder Technology AV Series - page 26
25 © 2006 Adder T echnology Limited All trademarks are acknowledged. Release 1.0d August 2006 Part No. ADD0059 Adder T echnology Limited, T echnology House, T rafalgar Way , B ...
Do you have a question concerning Adder Technology AV Series?
Use the form below
If you did not solve your problem by using a manual Adder Technology AV Series, ask a question using the form below. If a user had a similar problem with Adder Technology AV Series it is likely that he will want to share the way to solve it.