Manual Emerson CF980MBX 00

16 pages 0.32 mb
Download

Go to site of 16

Summary
  • Emerson CF980MBX 00 - page 1

    READ AND SA VE THESE INSTRUCTIONS Model No. CF980MAB 00 CF980MBX 00 EMX TUREEN ™ Part No. F40BP73530000 Form No. BP7353 U.L. Model No.: CF980 Net Weight: 35.8 Lbs. Damp Loca tion Ceiling F an Owner's Manual LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceili ...

  • Emerson CF980MBX 00 - page 2

    2 WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference 2 . Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally ...

  • Emerson CF980MBX 00 - page 3

    T ools Needed for Assembly One Phillips head screwdriver One stepladder MA TERIALS Wiring, outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of the following sizes: Unpac king Instr uctions For your convenience, check-off boxes are provided next to each step. As ea ...

  • Emerson CF980MBX 00 - page 4

    4 Electrical R equir ements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds. To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fa ...

  • Emerson CF980MBX 00 - page 5

    5 CAUTION: Before installing and tightening the screws, be sure there are no wires pinched between the bottom of the light kit assembly and fan motor. 5. Install the three #10-24 x 5/16” pan head screws to secure the light kit assembly to the lower housing (Figure 4). #10-24 x 5/16" P AN HEAD SCREW (3) LIGHT KIT ASSEMBL Y LOWER HOUSING Figur ...

  • Emerson CF980MBX 00 - page 6

    6 12. Position one of the blade assemblies onto the motor hub and secure blade assembly using two 1/4-20 x 1/2” oval head flange screws (provided). Repeat for all blade assemblies (Figure 8). 13. Slide the coupler cover over the downrod and position it to cover the motor coupling (Figure 9). 14. Position the ceiling cover over the downrod. Be sur ...

  • Emerson CF980MBX 00 - page 7

    7 2. Carefully lift the fan and seat the hanger ball/down- rod assembly on the hanger bracket that was just attached to the outlet box (Figure 13). Be sure the groove in the ball is lined up with the tab on the hanger bracket (Figure 12). Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard. WARNING ...

  • Emerson CF980MBX 00 - page 8

    8 OUTLET BOX BLACK SUPPL Y WIRE BLACK/WHITE RECEIVER WIRE BLACK F AN WIRE BLUE F AN WIRE BLUE RECEIVER WIRE YELLOW RECEIVER WIRE DO NOT USE CEILING COVER WHITE RECEIVER WIRE WHITE F AN WIRE WIRE CONNECTOR RECEIVER WHITE SUPPL Y WIRE SUPPL Y GROUND WIRE (GREEN OR BARE) HANGER BALL GROUND WIRE (GREEN) HANGER BRACKET GROUND WIRE (GREEN) HANGER BRACKET ...

  • Emerson CF980MBX 00 - page 9

    9 HANGER BRACKET OUTLET BOX RECEIVER CEILING COVER Figure 16 YELLOW RECEIVER WIRE DO NOT USE DOWNROD WHITE SUPPL Y WIRE BLACK F AN WIRE SW105 RECEIVER TO 110V SUPPL Y WHITE F AN WIRE BLUE RECEIVER WIRE BLUE F AN WIRE BLACK SUPPL Y WHITE RECEIVER WIRE BLACK RECEIVER WIRE BLACK/WHITE RECEIVER Check to see that all connections are tight, including gro ...

  • Emerson CF980MBX 00 - page 10

    2. Place the glass onto the light kit assembly aligning the three flat areas on the top flange of the glass with the three pins on the inside of the assembly (Figure 19). Then turn the glass clockwise until it stops turning. 3. Your ceiling fan is now installed and wire to be controlled by your remote control system. 10 50-WA TT MR-16, GU-10 HALOGE ...

  • Emerson CF980MBX 00 - page 11

    11 Setting Oper a ting F requency of W all Contr ol and R eceiv er (Figur e 20) Your wall control and receiver have code switches which must be set in one of 16 possible code combi- nations. The four levers (numbered 1, 2, 3, and 4) on the switches are factory-set in the ON (up) position. Change the switch settings as follows: 1. Slide the four swi ...

  • Emerson CF980MBX 00 - page 12

    12 AIRFLOW DIRECTION BUTTON LIGHT BUTTON FA N SPEED BUTTONS F AN OFF BUTTON RED INDICA TOR LIGHT FAN OFF LOW MED HI LIGHT REV Figure 23 T rouble Shooting W all Contr ol Fan/Light Fails to Operate • Check that the wall switch for the ceiling fan is in the “ON” position. • Check that the battery is good (red indicator light should light when ...

  • Emerson CF980MBX 00 - page 13

    13 INSTRUCTION T O THE USER (if device contains a digital device) This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interfer- ence in a residential installation. This equipment generates, us ...

  • Emerson CF980MBX 00 - page 14

    T rouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. 2. Loose power line connections to the fan, or loose 2. Check line power connections to fan and switch wire switch wire connections in the switch housing. connections in the s ...

  • Emerson CF980MBX 00 - page 15

    15 R epair Par ts 9 HI HI MED MED LOW LOW F A N O F F R E V R E V L I G H T 1 5 6 7 3 2 10 4 8 11 16 17 19 18 23 14 20 21 12 13 15 24 22 ...

  • Emerson CF980MBX 00 - page 16

    Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 Part No. F40BP73530000 Printed in China 10/07 Form No. BP7353 R epair Par ts Listing Part Numbers Key Model No. Model No. No. Description CF980MBX 00 CF980MAB 00 * Hanger Pack, Consisting of: 761655-67 761655-67 1 Hanger Bracket — — 2 Hanger Ball ? ...

Manufacturer Emerson Category Fan

Documents that we receive from a manufacturer of a Emerson CF980MBX 00 can be divided into several groups. They are, among others:
- Emerson technical drawings
- CF980MBX 00 manuals
- Emerson product data sheets
- information booklets
- or energy labels Emerson CF980MBX 00
All of them are important, but the most important information from the point of view of use of the device are in the user manual Emerson CF980MBX 00.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Emerson CF980MBX 00, service manual, brief instructions and user manuals Emerson CF980MBX 00. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Emerson CF980MBX 00.

Similar manuals

A complete manual for the device Emerson CF980MBX 00, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Emerson CF980MBX 00 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Emerson CF980MBX 00.

A complete Emerson manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Emerson CF980MBX 00 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Emerson CF980MBX 00, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Emerson CF980MBX 00, that we can find in the current document
3. Tips how to use the basic functions of the device Emerson CF980MBX 00 - which should help us in our first steps of using Emerson CF980MBX 00
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Emerson CF980MBX 00
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Emerson CF980MBX 00 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Emerson CF980MBX 00?

Use the form below

If you did not solve your problem by using a manual Emerson CF980MBX 00, ask a question using the form below. If a user had a similar problem with Emerson CF980MBX 00 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)