Manual Goodman Mfg R-410A

26 pages 0.48 mb
Download

Go to site of 26

Summary
  • Goodman Mfg R-410A - page 1

    GPC 14 SEER R-410A Package Air Conditioners with R-410A Copyright © 2009 Goodman Manufacturing Company, L.P. RT6322007r2 August 2009 **Note that these tax credits are subject to specific requirements set forth in the American Recovery and Reinvestment Act of 2009 and in the Internal Revenue Code. Goodman recommends that consumers consult a tax pro ...

  • Goodman Mfg R-410A - page 2

    PRODUCT IDENTIFICA TION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. WARNING WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure ...

  • Goodman Mfg R-410A - page 3

    PRODUCT IDENTIFICA TION 3 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. GPC1424H41A* GPC1430H41A* GPC1436H41A* GPC1442H41A* GPC1448H41A* GPC1460H41A* The United States Environmental Protection Agency (“EPA”) ...

  • Goodman Mfg R-410A - page 4

    4 PRODUCT DESIGN GPC Package Cooling Units are designed for outdoor instal- lations only in either residential or light commercial applica- tions. The connecting ductwork (Supply and Return) can be con- nected for either horizontal or vertical airflow. In the vertical application a matching Roof Curb is recommended. A return air filter must be inst ...

  • Goodman Mfg R-410A - page 5

    PRODUCT DESIGN 5 36" 36" 24" P L E N U M U N I T P L A T F O R M C U R B Rooftop Installation - Horizontal (H) In installations where the unit is installed above ground level and not serviceable from the ground (Example: Roof Top in- stallations), the installer must provide service platform for ser- vice person with rails or guards i ...

  • Goodman Mfg R-410A - page 6

    6 PRODUCT DESIGN HKR ELECTRICAL DA T A All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent protection du ...

  • Goodman Mfg R-410A - page 7

    PRODUCT DIMENSIONS 7 GPC14[24-60]H41A* Ch ass i s M o d el A B GPC 142 4 33 3 0½ GPC 143 0 33 3 0½ GPC 143 6 33 3 5½ GPC 144 2 33 3 5½ GPC 144 8 33 3 8½ GPC 146 0 33 3 8½ Dime n s ion s in i n c he s La rge Sm a l l Me d i u m 34.075 66.5 42 4. 51 2 14 . 0 00 14 . 0 00 SUP PLY 6.50 0 RE TU RN 4.500 BACK VI EW (DUC T OPEN I NGS) A 14 . 0 00 B ...

  • Goodman Mfg R-410A - page 8

    P ACKAGE COOLING SPECIFICA TIONS 8 All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent protection during ...

  • Goodman Mfg R-410A - page 9

    P ACKAGE COOLING SPECIFICA TIONS 9 All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent protection during ...

  • Goodman Mfg R-410A - page 10

    ACCESSORIES 10 P a r t N um b er De s c r i p t io n O T18- 60 A O utdoor Ther mosta t Kit w/Loc k out S ta t O T/EHR 18-60 Eme rgenc y Heat R el ay K i t HK R E lec tr i c Heat K i t PCCP101- 1 03 Roo f Cur b PCP101- 103 Down flow Pl enum Ki t PCP101- 103R 8 Dow nflow Pl enum Ki t w / R - 8 I ns u lati on PCEC101- 1 03 Dow nflow Ec onomi zer for G ...

  • Goodman Mfg R-410A - page 11

    BLOWER PERFORMANCE DA T A 11 Dry Coil Data GPC14[24-60]H41A* 0. 1 0 .2 0 .3 0 .4 0 .5 0 .6 0 . 7 0 .8 C F M 9 34 75 9 75 5 63 8 58 1 4 8 9 - - W A T T S 9 57 77 67 38 39 0 - - C F M 9 90 83 7 80 1 74 4 69 6 6 5 2 6 0 1 - W ATT S 1 07 9 4 10 5 11 0 1 1 9 1 3 3 14 2 - C F M 106 1 9 89 9 47 9 25 8 76 - - - W ATT S 1 26 1 3 4 14 6 15 8 16 9 - - - C F M ...

  • Goodman Mfg R-410A - page 12

    12 BLOWER PERFORMANCE DA T A 30 40 50 60 70 80 90 110 1 2 0 100 13 0 140 15 0 100 90 80 70 60 50 40 30 20 10 OUT P UT B TU/ H R x 10 00 BT U OUTPUT vs TEMPER AT URE RISE CHART TEMPERAT URE RISE 600 C FM 700 900 1000 1100 1200 140 0 160 0 1800 2000 220 0 240 0 C F M FORMULA S BTU OUTPUT = CFM x 1.08 x RISE RISE = BTU OUTPUT 1.0 8 ÷ CF M 800 ...

  • Goodman Mfg R-410A - page 13

    13 COOLING PERFORMANCE DA T A GPC1424H41A* MOD E L : G P C 1424H41A * EX PAN DE D P ER FO R MANC E D ATA C OOL I NG OP E R AT I ON De s ign Sub c ooli ng , 9 ± 2°F @ the l i qui d a c c e s s fitting c onn e ct i on A HRI 9 5 te s t c ondi t io ns . Desi gn S upe r he at 5 ± 2 °F @ the c om pr es sor s uct i o n a cce ss fi tti n g co n nect io ...

  • Goodman Mfg R-410A - page 14

    14 COOLING PERFORMANCE DA T A GPC1424H41A* MOD E L : G PC 1424H41A * EX PA N DE D P ER F O R M AN C E D AT A C OOL I NG OP ER AT I ON De s i gn Sub cooli ng , 9 ± 2°F @ the l i qui d acce s s f i tting c onn e ct i on A HRI 9 5 te s t c ondi t i ons . De s i gn S upe r he at 5 ± 2 °F @ the c om pr es sor s u cti on a cce ss fi t ti ng co n nect ...

  • Goodman Mfg R-410A - page 15

    15 COOLING PERFORMANCE DA T A GPC1430H41A* MOD E L : G P C 1430H41A * EX PAN DE D P ER F O R M AN C E D ATA C OOLI NG OP ER ATI ON De s i gn S ubc ooli ng , 1 0 ± 2 °F @ the l i qui d a c ce s s f i tting c onnec tion A RI 9 5 test c ondi tio ns . De s i g n S up e rh e at 1 0 ± 2 °F @ the c o m p r es sor sucti o n acc ess f itt i n g co n n e ...

  • Goodman Mfg R-410A - page 16

    16 COOLING PERFORMANCE DA T A GPC1430H41A* MOD E L : G PC 1430H41A * EX PA N DE D P ER F O R M AN C E D AT A C OOL I NG OP ER AT I ON De s ign S ubc ool i ng , 1 0 ± 2 °F @ the l i qui d a c ce s s f i tting c onne ct i on A R I 9 5 t e st conditio ns . De s i g n Sup e rh e at 1 0 ± 2 °F @ the c o m p r es so r suct i o n acc ess f itt i n g c ...

  • Goodman Mfg R-410A - page 17

    17 COOLING PERFORMANCE DA T A GPC1436H41A* MOD E L : G P C 1436H41A * EX PAN DE D P ER F O R M AN C E D ATA C OOLI NG OP ER ATI ON De s i gn Sub cooli ng , 10 ± 2 °F @ t he l iqui d a cc e ss fitting con ne c t i on A RI 95 te st c onditi ons. De s i gn S uperhe at 9 ± 2 °F @ t he c omp r e ssor su cti o n acc ess f it ti n g co n n e cti o n . ...

  • Goodman Mfg R-410A - page 18

    18 COOLING PERFORMANCE DA T A GPC1436H41A* MOD E L : G PC 1436H41A * EX PA N DE D P ER F O R M AN C E D AT A C OOL I NG OP ER AT I ON De s i gn Sub cooli ng , 10 ± 2 °F @ t he l iqui d a cc e ss fitting con ne c t i on A RI 95 te st cond i tions. De sign S uperhe at 9 ± 2 °F @ t he c omp r e ssor su cti o n acc ess f it ti n g co n n e cti o n ...

  • Goodman Mfg R-410A - page 19

    19 COOLING PERFORMANCE DA T A GPC1442H41A* MOD E L : G P C 1442H 41A * EX PAN DE D P ER FO R M ANC E D AT A C OOLI NG OP E R ATION Desi g n Su b co o l i n g , 8 ± 2 ° F @ th e l i q u i d acc ess f it ti ng co n n e cti o n A H R I 9 5 test c o n d i t i o n s. D esi g n Su p er h ea t 8 ± 2 ° F @ t h e co m p re sso r su ct io n ac ces s fi t ...

  • Goodman Mfg R-410A - page 20

    20 COOLING PERFORMANCE DA T A GPC1442H41A* MOD E L : G PC 1442H41A * EX PA N DE D P ER F O R M AN C E D AT A C OOL I NG OP ER AT I ON Desi g n Su b co o l i n g, 8 ± 2 ° F @ th e l iqu i d acc ess f it ti n g co n n e ct i o n A HR I 9 5 t est c o n d i t i o n s. D esi g n Su p er h ea t 8 ± 2 ° F @ t h e co m pr e s s or suc t i on acce s s f ...

  • Goodman Mfg R-410A - page 21

    21 COOLING PERFORMANCE DA T A GPC1448H41A* MOD E L : G P C 1448H41A * EX PAN DE D P ER F O R M AN C E D ATA C OOLI NG OP ER ATI ON De s i gn Sub cooli ng , 10 ± 2 °F @ the l i qui d a c ce s s f i tting c onne c tion A HRI 95 te s t c ondi ti ons . Desi gn S u pe r he at 1 0 ± 2 °F @ t he c ompr e ss or suc tion ac c es s fi t ti n g c onne c t ...

  • Goodman Mfg R-410A - page 22

    22 COOLING PERFORMANCE DA T A GPC1448H41A* MOD E L : G PC 1448H41A * EX PA N DE D P ER F O R M AN C E D AT A C OOL I NG OP ER AT I ON De s i gn Sub cooli ng , 10 ± 2 °F @ the l i qui d acce s s f i tting c onnec tion A HRI 95 te s t c ondi ti ons . Desi gn S u pe r he a t 10 ± 2 ° F @ t he c o mpr e ss or suc tion a c c e s s fi t tin g c onne ...

  • Goodman Mfg R-410A - page 23

    23 COOLING PERFORMANCE DA T A GPC1460H41A* MOD E L : G P C 1460H41A * EX PAN DE D P ER F O R M AN C E D ATA C OOLI NG OP ER ATI ON Desi g n Su b co o l i n g, 6 ± 2 ° F @ th e l iqu i d acc ess f it ti n g co n n e cti o n A H R I 9 5 t est c on d i t i o n s. D esi g n Su p er h ea t 9 ± 2° F @ th e co m p re s s or s uct io n a cc e s s fit t ...

  • Goodman Mfg R-410A - page 24

    24 COOLING PERFORMANCE DA T A GPC1460H41A* MOD E L : G PC 1460H41A * EX PA N DE D P ER F O R M AN C E D AT A C OOL I NG OP ER AT I ON De s i gn Sub cooli ng , 6 ± 2 °F @ the l i quid ac c es s fi t t i n g co nne c tion AH RI 9 5 t e s t c ond iti ons. De sign S upe r hea t 9 ± 2 °F @ the c ompre s s or sucti o n a c ce s s f itting c onne c ti ...

  • Goodman Mfg R-410A - page 25

    25 COOLING PERFORMANCE DA T A PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoo r air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatures incr ...

  • Goodman Mfg R-410A - page 26

    26 WIRING DIAGRAMS Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. WARN I NG HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE POWE R S OUR CES MAY B E PRESENT . F AILURE TO DO SO MAY CAUSE PROPERTY DAM AGE, PERSONAL INJURY OR DEATH. GPC14[24-60]H41A* ...

Manufacturer Goodman Mfg Category Air Conditioner

Documents that we receive from a manufacturer of a Goodman Mfg R-410A can be divided into several groups. They are, among others:
- Goodman Mfg technical drawings
- R-410A manuals
- Goodman Mfg product data sheets
- information booklets
- or energy labels Goodman Mfg R-410A
All of them are important, but the most important information from the point of view of use of the device are in the user manual Goodman Mfg R-410A.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Goodman Mfg R-410A, service manual, brief instructions and user manuals Goodman Mfg R-410A. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Goodman Mfg R-410A.

A complete manual for the device Goodman Mfg R-410A, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Goodman Mfg R-410A by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Goodman Mfg R-410A.

A complete Goodman Mfg manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Goodman Mfg R-410A - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Goodman Mfg R-410A, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Goodman Mfg R-410A, that we can find in the current document
3. Tips how to use the basic functions of the device Goodman Mfg R-410A - which should help us in our first steps of using Goodman Mfg R-410A
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Goodman Mfg R-410A
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Goodman Mfg R-410A in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Goodman Mfg R-410A?

Use the form below

If you did not solve your problem by using a manual Goodman Mfg R-410A, ask a question using the form below. If a user had a similar problem with Goodman Mfg R-410A it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)