    IAQ GUIDE 1 1 HEALTHY HOME SYSTEM ™ ...

  • Field Controls IAQ11 - page 2

    2 FRESH CLEAN P U R E FRESH CLEAN P U R E Field Controls has developed the premier system that simply and inexpensively transforms the heating and cooling system in any home into a Healthy Home System. The Healthy Home System goes beyond traditional technology to ensure air that is Fresh, Clean, and Pure. ™ Introducing the Healthy Home System ™ ...

  • Field Controls IAQ11 - page 3

    FRESH CLEAN P U R E fieldcontrols.com 3 FRESH CLEAN P U R E Healthy Home System™ Control Media Air Cleaner™ UV -Aire ® Air from all rooms RETURN T o all rooms FRESH, CLEAN , PURE AIR Fresh Air Damper For installation options (including upflow, horizontal, downflow, and heat pumps/gas packs) turn to page 5. Upgrade any heating and cooling syste ...

  • Field Controls IAQ11 - page 4

    4 FRESH CLEAN P U R E FRESH CLEAN P U R E FRESH Fresh Air Ventilation CLEAN Media Air Cleaners PURE UV-Aire ® Purification For the Home • Creates uniform temperature and humidity throughout the home • Helps meet residential ventilation standard ASHRAE 62.2 • Enhances whole house filtration and air purification • Virtually maintenance free ...

  • Field Controls IAQ11 - page 5

    FRESH CLEAN P U R E fieldcontrols.com 5 FRESH CLEAN P U R E INSTALLATION OPTIONS HORIZONT AL UPFL OW DOWNFL OW EXTERNAL HEA T PUMP or GAS P ACK UV -Aire ® Air Purifier Fresh Air Damper RETURN Media Air Cleaner™ UV -Aire ® Air Purifier RETURN RETURN RETURN Media Air Cleaner™ Media Air Cleaner™ Fresh Air Damper Fresh Air Damper UV -Aire ® Ai ...

  • Field Controls IAQ11 - page 6

    6 FRESH FRESH CONTROL The heart and brains of the Healthy Home System The Healthy Home System Control intelligently manages the central fan to maximize the benefits of the Healthy Home System. It’s the easiest, most cost effective way to ensure the air in the home is FRESH , CLEAN, and PURE ...even when not heating or cooling. Healthy Home System ...

  • Field Controls IAQ11 - page 7

    FRESH fieldcontrols.com 7 FRESH • Delivers fresh air automatically, year round • Enables system to meet ASHRAE 62.2 ventilation standard for fresh air • Creates uniform temperature and humidity throughout the home • Enhances effectiveness of whole house filtration and air purification Benefits FRESH The Healthy Home System ™ Control intel ...

  • Field Controls IAQ11 - page 8

    8 CLEAN CLEAN The Media Air Cleaner is a whole house air filtration system that combines minimum maintenance with maximum air cleaning capacity. As part of the Healthy Home System, the media air cleaner works with the Healthy Home System Control to CLEAN the air in the home all year round...even when not heating or cooling. Whole house air filtrati ...

  • Field Controls IAQ11 - page 9

    CLEAN fieldcontrols.com 9 CLEAN Dimensions Cabinet A B C Duct Opening D E 1400 7 1 ⁄ 8 " 24 7 ⁄ 8 " 16 1 ⁄ 4 " 22 1 ⁄ 2 " 13 7 ⁄ 8 " 2000 7 1 ⁄ 8 " 24 7 ⁄ 8 " 20 1 ⁄ 4 " 22 1 ⁄ 2 " 17 7 ⁄ 8 " CLEAN How it works The Field Controls Media Air Cleaner cabinet is installed in the retu ...

  • Field Controls IAQ11 - page 10

    10 PURE PURE Field Con trols of f ers a c omple te line of U V - A ire p roduc t s for any home or busine ss, wit h a variet y of duc t-mo unte d mode ls design ed for fo rced- air hea ting and cooling s ys te ms. U V - Aire ge rmicidal lamps c ontinuousl y at t ack airb orne mold, b ac ter ia and vir use s as they circulate t hrough your duc t wor ...

  • Field Controls IAQ11 - page 11

    PURE fieldcontrols.com 11 PURE Optional Installation Location Best Installation Location (down-stream of the A-coil) H A-Coil Installing UV-Aire near the coil helps maintain optimal efficiency of the VAC system. CLEAN AIR T o all rooms Return air from all rooms Primary UV zone Alternate UV zone Ultraviolet T reatment Zones How it works UV-Aire uses ...

  • Field Controls IAQ11 - page 12

    12 PORTABLES Portable air purification The portable UV-Aire models combine the purifying power of UV with high efficiency and carbon filtration to reduce dust, pollen, odors and VOCs. The UV-Aire portables are recommended for anyone with allergies, a respiratory illness, or a compromised immune system. For ductless systems and extra protection The ...

  • Field Controls IAQ11 - page 13

    fieldcontrols.com 13 The Smart Switch for Smart Houses The easiest, most cost efficient way to help make a home ASHRAE 62.2 compliant. The SmartExhaust turns the bathroom fan into an automatic exhaust system that helps eliminate stale air from the home. How it works The SmartExhaust™ is set by the installer to automatically turn the fan on once p ...

  • Field Controls IAQ11 - page 14

    14 UV-Aire ® Air Purification Lamps Model Ref. No. Description Part No. UV-12, UV-1500C C Lamp 12" 46365401 UV-16/120, UV-16/24 C Lamp 16" 46511200 UV-18 C Lamp 18" 46365402 UV-28 C Lamp 28" 46365403 UV-500C C Lamp 8" 46508000 Portable UV-Aire ® Annual Replacement Kits Model Ref. No. Description Part No. UV-1500RK D Annua ...

  • Field Controls IAQ11 - page 15

    fieldcontrols.com 15 PURE U V- A i r e ® I n - D u c t M o d e l s M o d e l M i n i m u m D u c t W i d t h ( I n c h e s) Vo l t a g e A m p s Wa t t s R e c o m m e n d e d M a x . S q . F t . U V -12 9 120 0.5 30 1500 U V -18 14 120 0.5 30 2000 U V -2 8 22 120 1.1 60 3000 U V -12 E 9 120/240 0.5 30 1500 U V -18 E 14 120/240 0.5 30 2000 U V -2 ...

  • Field Controls IAQ11 - page 16

    fieldcontrols.com ©2011 Field Controls Form # 4342 Printed in U.S.A.(TD11) Fi el d C on tr ols , L LC 2630 Airport Road Kinston, NC 28504 T: 252.522.3031 F: 252.522.0214 ...

Manufacturer Field Controls Category Air Cleaner

Documents that we receive from a manufacturer of a Field Controls IAQ11 can be divided into several groups. They are, among others:
- Field Controls technical drawings
- IAQ11 manuals
- Field Controls product data sheets
- information booklets
- or energy labels Field Controls IAQ11
All of them are important, but the most important information from the point of view of use of the device are in the user manual Field Controls IAQ11.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Field Controls IAQ11, service manual, brief instructions and user manuals Field Controls IAQ11. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Field Controls IAQ11.

A complete manual for the device Field Controls IAQ11, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Field Controls IAQ11 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Field Controls IAQ11.

A complete Field Controls manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Field Controls IAQ11 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Field Controls IAQ11, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Field Controls IAQ11, that we can find in the current document
3. Tips how to use the basic functions of the device Field Controls IAQ11 - which should help us in our first steps of using Field Controls IAQ11
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Field Controls IAQ11
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Field Controls IAQ11 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Field Controls IAQ11?

Use the form below

If you did not solve your problem by using a manual Field Controls IAQ11, ask a question using the form below. If a user had a similar problem with Field Controls IAQ11 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)