Billion Electric Company BIPAC-2AB 2.0 - page 1
BIP AC-2AB 2.0 ISDN a/b Adaptor User ’ s Manual ...
-
Billion Electric Company BIPAC-2AB 2.0 - page 2
Declarati o n of Conform i ty Konformit ätserkl ärung in accordance w ith the Radio a nd T elecommu nications T erminal Equipment Act (FTEG) and Dire ctiv e 19 9 9/5 /E C (R&TTE Dir ective) gemäß dem Gesetz über Funkanla gen und T elekomm unikationsendeinr ichtungen (FTEG) und der Richt linie 1999/5/EG (R&TTE) The Manufacturer: Billion ...
-
Billion Electric Company BIPAC-2AB 2.0 - page 3
Table of Contents CHAPTER 1 1 Intr oduction ................. ................................................ .................. 1 An Overview of the BIP AC-2AB 2.0 .................... ...................... 1 Package Contents .......... ........................ ........................ ............... 2 BIP AC-2AB 2.0 Features ............... .. ...
-
Billion Electric Company BIPAC-2AB 2.0 - page 4
...
-
Billion Electric Company BIPAC-2AB 2.0 - page 5
Chapter 1 Introduction An Overview of the BIP AC-2AB 2.0 What is ISDN? ISDN is an abbreviation for I ntegrated S ervices D igital N etwork. IS DN transfers information digitally and inte grates all telecomm unication services (such as te lephone, teletext, videotex, etc.) into a single network. Using ISDN, you can transfer text, voice, data file s, ...
-
Billion Electric Company BIPAC-2AB 2.0 - page 6
BIP AC-2AB 2.0 User’ s Manual 2 The BIP AC-2AB 2.0 ISDN a/b Adaptor The BIP AC-2AB 2.0 ISDN a/b adaptor a llows you to make the transition from analog to digital without having to disc ard all your present analog devices. The BIP AC-2AB 2.0 provides an interface be tween your ISDN line and prese nt analog devices such as your telephone. W ith a f ...
-
Billion Electric Company BIPAC-2AB 2.0 - page 7
Chapter 1 Intr oduction 3 2. One RJ-45 cable 3. One AC-to - DC power adap to r 4. This User ’ s Manual BIP AC-2AB 2.0 Featur es The BIP AC-2AB 2.0 supports many standard and enhanced fea tures that allow you to make full use of ISDN services w ith your existing analog devices, including the following: Caller ID Individual phone number (MS ...
-
Billion Electric Company BIPAC-2AB 2.0 - page 8
Chapter 2 Using BIPAC-2AB 2.0 Befor e Connecting Make sure that you have all you need to connect the BIP AC-2AB 2.0 ISDN a/b adaptor . Y ou should have the following: 1. At least one analog telephone (or othe r analog device) 2. A power outlet that supplies 220 ~ 240 volts AC 3. An ISDN basic rate S 0 interface re leased by PTT (Post, Telephone and ...
-
Billion Electric Company BIPAC-2AB 2.0 - page 9
Chapter 2 Using BIP AC-2AB 2.0 5 F IGURE 2: C ONNECTING THE BIPAC-2AB 2.0 4. The BIPAC-2AB 2.0 ISDN a/b adaptor will run a Power-On self- diagnostic test. The LEDs on the front panel will blink on and off one by one and the connect ed analog telephones will ring. The Fr ont Panel LEDs The following illustration and table describe the fron t panel L ...
-
Billion Electric Company BIPAC-2AB 2.0 - page 10
BIP AC-2AB 2.0 User’ s Manual 6 Pr ogramming the BIP A C-2AB 2.0 Functions The functions of BIP AC-2AB 2.0 are programmed by the use of the telephone number keys (0 ~ 9), the pound key (#), and the star key ( * ). You should hear 2 short tones if the programming is successful; otherwise, you will hear more than 6 tones indicating failure of progr ...
-
Billion Electric Company BIPAC-2AB 2.0 - page 11
Chapter 2 Using BIP AC-2AB 2.0 7 Caller ID Setup * 94 * Pass * Func Id * P arameter # Func Id=0, Enabling Flag=0 or null: disable Flag=1: enable Func I d=1, Caller ID T y pe Parame ter = 0~4 Func Id=2: Caller ID Country Parame ter= 0~ 99 Func I d=3, Date and T ime Func Id=4, Call wai ting Fun c Id =5, Inse rt ze ro n um ber Flag=0 or null: disable ...
-
Billion Electric Company BIPAC-2AB 2.0 - page 12
BIP AC-2AB 2.0 User’ s Manual 8 Ring Pattern (Alert On/O ff Length ) Setup * 83 * Pass * Func Id * Parameter # Func Id=0, Ring unit parame ter=01~99(0.1s) Default is 10 (1s) Func Id=5 , Hold Notice Para meter=00~99 Rin g unit Default is 0 Func Id=1~3, MSN1 ~3 Func Id= 4, Defa ult Ring Pat tern Func I d=6, Inte rnal Ring P attern Param eter=x 1 x ...
-
Billion Electric Company BIPAC-2AB 2.0 - page 13
Chapter 2 Using BIP AC-2AB 2.0 9 Function Desc rip ti on External Callin g To mak e an external ph one call, dial the nu mber as you would with a r egular phone syst em. Inter-call or Internal Callin g To make a call to the other an al og port of the ISDN a/ b adaptor, you can press: # Speed Dialing To dial a ny of the Spee d Di alin g numbe rs tha ...
-
Billion Electric Company BIPAC-2AB 2.0 - page 14
BIP AC-2AB 2.0 User’ s Manual 10 Call Waiting If you have a n active c all a nd the Call Wa iting f u nction i s enabled, you wil l hear t wo tones when there is another incom ing call. You ca n swi tch betwe en the two cal ls by using the Hold/Retrieve funct ion ( * # ). Internal Call Transfer To transfer a call to the other analog port of t he ...
-
Billion Electric Company BIPAC-2AB 2.0 - page 15
Chapter 2 Using BIP AC-2AB 2.0 11 Keyp ad Some tele phone compa n i es’ ISDN syst e ms are using “Keypad Protocol ” for a ctivat i ng/deact ivati ng some supplement ar y services, such as external call forwarding. To let the ISDN a/b adaptor ent e r “Keypad” mode, you ca n pr e ss: *00 Then, al l the fol lowing ke ys and num be rs will be ...
-
Billion Electric Company BIPAC-2AB 2.0 - page 16
Chapter 3 Troubleshooting T r oubleshooting Pr ocedur es Error Event Possible Cause Remedy The B1 LED is always lit after power up The RAM is defective. Consult y our dealer. The B2 LED is always lit after power up The ISDN chip is defective. Consult your dealer. No dial tone from ISDN switch or PABX 1. Can not activ ate S 0 1. Ensure that the ISD ...
-
Billion Electric Company BIPAC-2AB 2.0 - page 17
Appendix A — Product Support 13 Error Event Possible Cause Remed y Can not receive incoming call. 1. Inco ming call ’ s phone number does not match any a/b port’s phone number 1. Ensure that t he phone number for each a/b port is correctly configured. 2. Do Not Di st urb function has been enabled. 2. Disable Do No t Disturb . 3. Call Forwardi ...
Do you have a question concerning Billion Electric Company BIPAC-2AB 2.0?
Use the form below
If you did not solve your problem by using a manual Billion Electric Company BIPAC-2AB 2.0, ask a question using the form below. If a user had a similar problem with Billion Electric Company BIPAC-2AB 2.0 it is likely that he will want to share the way to solve it.