    F OR B409 D OUBLE W ALL T ANK S UMP WITH REINFORCED BOTT OM S. Bravo Systems, Inc. 2929 V ail A ve. - Commerce, CA 90040 (323) 888-4133 - F AX: (323) 888-4123 www .SBravo.com ii-B409-DW-10A INST ALLA TION INSTRUCTIONS Written by: Jonathan Smith ...

  • Bravo B409 - page 2

    READ THESE INSTRUCTIONS - KEEP FOR FUTURE REFERENCE T ABLE OF CONTENTS DRY FITTING SUMP & EQUIPMENT ................................ p. 4 A) Installing & Securing.......................................................... p. 5 Install & T est Penetration Fittings...................................... p. 5 (A.4) B) Mantadory Air Integrity ...

  • Bravo B409 - page 3

    3 ii-B409-DW-10A It is REQUIRED to visually check the V acuum gauge on each and every Bravo Systems Double W all product and write on its F AX report V acuum level , name of observer , and date for every DoubleW all Sump. A) There is a failure to comply with the Required written report guidelines as stated above. B) Double W all Products are DOUBLE ...

  • Bravo B409 - page 4

    4 ii-B409-DW-10A EQUIPMENT DR Y -FIT - BEFORE INST ALLING PENETRA TION FITTINGS - BEFORE CUTTING OPEN SUMP INTERSTICE DR Y -FIT YOUR SUMP PIECES AND INTERNAL EQUIPMENT . PLAN YOUR INST ALLA TION AND MAKE SURE EVER YTHING FITS, AND WILL FIT LA TER DURING INST ALLA TION. Recommended T ools (NOT PROVIDED) Power/air Sanders. Acetone to clean up tools/a ...

  • Bravo B409 - page 5

    A.1 - Visually inspect the p arts provided by Bravo Systems for In-transit damage and/or missing part s. Continue to keep the Sump clean of debris throughout your installation process. A.2 - Set your B409 Piping Sump where it must be per site plans. Secure the Sump to avoid movement while penetrating. A.3 - Mark where you will penetrate the Base/T ...

  • Bravo B409 - page 6

    B - MANDA T OR Y AIR INTEGRITY TEST B.1 - Use test assembly and pressure sump to no more than 4 PSI. Close off with ball valve and resume other work. Allow 1 Hour before recording pressure. F IELD A IR I NTEGRITY I NSPECTION T EST : Hold pressure for a minimum of 1 hour for a Field Integrity Inspection T est. The T ank Sump P ASSES the integrity te ...

  • Bravo B409 - page 7

    C - V ACUUM / HYDROST A TIC FILLING F IELD A IR I NTEGRITY I NSPECTION T EST : YOUR PRODUCT W ARRANTY WILL BE VOID IF YOU DO NOT Hold pressure for a minimum of 1 hour for a Field Integrity Inspection T est. After passing the pressure test, it is HIGHL Y RECOMMENDED that the 4 PSI is maintained for as long as possible, up until the time of backfill. ...

  • Bravo B409 - page 8

    8 C.3 - Close off ball valve completely and prime the open ended 36” length of clear tubing with provided Interstitial Fluid. Use a liquid funnel. Filling Bravo Systems Double W all Product s with Brine (saline) solution will void the product warranty . Y ou must use only Bravo-Supplied Interstitial Fluid , p art # IMF-1GAL C.4 - Af ter filling t ...

  • Bravo B409 - page 9

    D) ADV ANCED LEAK DETECTION PROCEDURE A Bravo Systems Exclusive detection method D.1 - Clear debris from the top open area of the DoubleW all Product and ensure that the interior walls are clean of debris and visible. D.2 - Apply V acuum to the sealed interstitial sp ace with the V enturi V acuum Assembly , and generate 20”-30” of vacuum for a ...

  • Bravo B409 - page 10

    Even though Bravo DoubleW all product corners and edges are thicker than the rest of the Containment sump, These areas recieve the most supceptable to physical damage by Installing Contractors. Y ou would do well to be extremely careful with these DoubleW all products while storing, moving, transporting and Installing these critical environment al ...

  • Bravo B409 - page 11

    E - CONNECTING T O MANOMETER E.1 - At this point, after the ALDP test, the interstice should still be holding vacuum. Maintain 20” of V acuum and slowly open ball valve to let fluid into the interstice until it exits the venturi assembly . Visually check whether the fluid level reaches the top of the interstitial sp ace. E.2 - Cut the barb & ...

  • Bravo B409 - page 12

    12 ii-B409-DW-10A G - Concrete and Backfill Guidelines. T o ensure that no immediate or future damage is done to your Bravo T ank Sump Reducer components, make sure that your manhole skirt DOES NOT T OUCH OR REST ON THE T ANK SUMP SHOULDER. The Manhole Skirt should be kept at minimum of 4” away from the tank sump shoulder . Follow the manhole man ...

Manufacturer Bravo Category Water Pump

Documents that we receive from a manufacturer of a Bravo B409 can be divided into several groups. They are, among others:
- Bravo technical drawings
- B409 manuals
- Bravo product data sheets
- information booklets
- or energy labels Bravo B409
All of them are important, but the most important information from the point of view of use of the device are in the user manual Bravo B409.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Bravo B409, service manual, brief instructions and user manuals Bravo B409. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Bravo B409.

Similar manuals

A complete manual for the device Bravo B409, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Bravo B409 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Bravo B409.

A complete Bravo manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Bravo B409 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Bravo B409, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Bravo B409, that we can find in the current document
3. Tips how to use the basic functions of the device Bravo B409 - which should help us in our first steps of using Bravo B409
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Bravo B409
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Bravo B409 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Bravo B409?

Use the form below

If you did not solve your problem by using a manual Bravo B409, ask a question using the form below. If a user had a similar problem with Bravo B409 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)