  • Mitsubishi Electronics PEFY-P-VMM-E - page 1

    I Air -Conditioner s INDOOR UNIT PEFY-P-VML-E PEFY-P-VMS-E PDFY-P-VM-E PEFY-P-VMM-E PEFY-P-VMR-E-L/R PFFY-P-VLRM(M)-E PEFY-P-VMH-E PLFY-P-VLMD-E PFFY-P-VLEM-E GB PO HG SV CZ TR RU GR P NL I E F D SL OPERA TION MANU AL For saf e and correct use, please read this oper ation manual thoroughly before oper ating the air-conditioner unit. BEDIENUNGSHANDB ...

  • Mitsubishi Electronics PEFY-P-VMM-E - page 2

    Remote controller -Button Fernbedienungs-T aste T ouche Commande à distance 1 [T emperatureinstellung]-T aste 2 [TIMER MENU]-T aste 3 [Modus]-T aste [MONITOR/SET]-T aste [BACK]-T aste 4 [TIMER ON/OFF]-T aste 5 [Luftklappe]-T aste [SET DA Y]-T aste [OPERA TION]-T aste 6 [Gebläsegeschwindigk eit]-T aste 7 [Richtungsklappensteuerung]-T aste 8 [Lüft ...

  • Mitsubishi Electronics PEFY-P-VMM-E - page 3

    5 GB D F I NL E P GR RU TR A Hora actual/Hora do temporizador B Indicador de controlo centralizado C Indicador de temporizador OFF D Indicador de modo do temporizador E Visor do modo de funcionamento: COOL, DR Y , AU TO, F AN, HEA T F Indicador do modo de funcionamento G T emperatura predefinida H Indicador de corrente I Aba J V entila çã o K Sin ...

  • Mitsubishi Electronics PEFY-P-VMM-E - page 4

    8 [Fig. A] A <PLFY -P125VLMD-E> <PDFY -P-VM-E> <PEFY -P-VML-E> <PEFY -P-VMM-E> A A <PLFY -P20~100VLMD-E> A A 12 A : Filter Filter Filtre Filtro Filtro Filter Filtro º›ÏÙÚÔ Фильтр Filtre : Air Flow Luftstrom Flux d’air Flujo de aire Flusso d’aria Luchtstroom Fluxo de Ar ƒÔ‹ ·¤Ú· Воздушны ...

  • Mitsubishi Electronics PEFY-P-VMM-E - page 5

    9 A A <PEFY -P-VMH-E> <PFFY -P-VLEM-E, VLRM(M)-E> <PEFY -P-VMR-E-L/R> A A [Fig. A] <PEFY -P-VMS-E> 12 A A : Filter Filter Filtre Filtro Filtro Filter Filtro º›ÏÙÚÔ Фильтр Filtre : Air Flow Luftstrom Flux d’air Flujo de aire Flusso d’aria Luchtstroom Fluxo de Ar ƒÔ‹ ·¤Ú· Воздушный поток ...

  • Mitsubishi Electronics PEFY-P-VMM-E - page 6

    10 GB D F E I NL P GR RU TR GB GB GB GB GB 1. Safety precautions s Before operating the unit, make sure you read all the “Safety precautions”. s “Safety precautions” lists important points about safety . Please be sure to follo w them. Symbols used in the text W arning: Describes precautions that should be observed to av oid the risk of inj ...

  • Mitsubishi Electronics PEFY-P-VMM-E - page 7

    11 I GB D F E I NL P GR RU TR GB GB GB GB GB W arning: • Do not remove the fr ont panel or the fan guard from the outdoor unit when it is running. Y ou could be injured if you touch r otating, hot or high- volta ge par ts. • Never insert fingers, sticks etc. into the intakes or outlets, otherwise in- jury may result, since the fan inside the un ...

  • Mitsubishi Electronics PEFY-P-VMM-E - page 8

    12 GB D F E I NL P GR RU TR GB GB GB GB GB PEFY-P40~140VMH, PFFY-P-VLEM, PFFY-P-VLRM PDFY-P100·125VM, PEFY-P100~140-VMM series F an speed : 2 stages Display: (Lo w) → (High) [PLFY-P125VLMD, PDFY-P20~80VM series] F an speed : 4 stages Display: (Lo w) → (Mid2) → (Mid1) → (High) [PLFY-P20~100VLMD, PEFY-P-VML, PEFY-P20~80-VMM, PEFY-P-VMR serie ...

  • Mitsubishi Electronics PEFY-P-VMM-E - page 9

    13 I GB D F E I NL P GR RU TR GB GB GB GB GB 3.6. V entilation • The ventilation unit (O A processing unit or LOSSNA Y) automatically goes into operation when the indoor unit that is interlock ed with it goes into operation. • If the 8 [V entilation] button is pressed while the indoor unit is stopped, only the ventilator goes into operation. ? ...

  • Mitsubishi Electronics PEFY-P-VMM-E - page 10

    14 GB D F E I NL P GR RU TR GB GB GB GB GB 6. T r oubleshooting Before y ou ask for repair service, chec k the following points: State of Machine It does not run. Air flows out but it does not cool enough or heat enough. Cool air or warm air does not come out. It runs briefly , but soon stops. The sound of the ex- haust and rotation of the motor ca ...

  • Mitsubishi Electronics PEFY-P-VMM-E - page 11

    15 I GB D F E I NL P GR RU TR GB GB GB GB GB 7. Installation, transferring works, and chec king Regarding place f or installation Consult with your dealer f or details on installation and transferring the installation. Caution: Never install the air conditioner where there is a risk of leakage of flammab le gas. If gas leaks and accumulates ar ound ...

  • Mitsubishi Electronics PEFY-P-VMM-E - page 12

    16 GB D F E I NL P GR RU TR GB GB GB GB GB P250VMH-E 28.0/31.5 470/1,250/1,120 100 72.0 110/220 130/260 50 52 P200VMH-E 22.4/25.0 470/1,250/1,120 100 58.0 110/220 130/260 42 44 3N~380-415V 50/60Hz P63VMH-E 7.1/8.0 380/750/900 45 13.5-19.0 50/100/200 100/150/200 32-38 36-41 P40VMH-E 4.5/5.0 380/750/900 44 10.0-14.0 50/100/200 100/150/200 27-34 31-37 ...

  • Mitsubishi Electronics PEFY-P-VMM-E - page 13

    17 I GB D F E I NL P GR RU TR GB GB GB GB GB P32VM-E 3.6/4.0 295 (58) 710 (790) 735 (600) 27 (5) 6.0-6.5-7.5-8.5 30/50/100 28-30-33-36 P ower source Cooling capacity*1/Heating capacity*1 kW Height mm Dimension*2 Width mm Depth mm Net weight kg Fa n Airflow rate (Lo w-Middle2-Middle1-High) m 3 /min External static pressure*4 P a Noise le vel (Low-Mi ...

  • Mitsubishi Electronics PEFY-P-VMM-E - page 14

    18 GB D F E I NL P GR RU TR GB GB GB GB GB Notes: * Operation temperature of indoor unit. Cooling mode: 15 ° C WB - 24 ° C WB Heating mode: 15 ° C DB - 27 ° C DB *1 Cooling/Heating capacity indicates the maximum value at operation under the f ollowing condition. Cooling: Indoor : 27 ° C DB/19 ° C WB Outdoor: 35 ° C DB Heating: Indoor : 20 ° ...

  • Mitsubishi Electronics PEFY-P-VMM-E - page 15

    WT04883X02 HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN Please be sure to put the contact address/telephone number on this manual before handing it to the customer. The product at hand is based on the following EU regulations: • Low Voltage Directive 73/23/EEC • Electromagnetic Compatibility Directive 89/ 336/E ...

Manufacturer Mitsubishi Electronics Category Air Conditioner

Documents that we receive from a manufacturer of a Mitsubishi Electronics PEFY-P-VMM-E can be divided into several groups. They are, among others:
- Mitsubishi Electronics technical drawings
- PEFY-P-VMM-E manuals
- Mitsubishi Electronics product data sheets
- information booklets
- or energy labels Mitsubishi Electronics PEFY-P-VMM-E
All of them are important, but the most important information from the point of view of use of the device are in the user manual Mitsubishi Electronics PEFY-P-VMM-E.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Mitsubishi Electronics PEFY-P-VMM-E, service manual, brief instructions and user manuals Mitsubishi Electronics PEFY-P-VMM-E. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Mitsubishi Electronics PEFY-P-VMM-E.

A complete manual for the device Mitsubishi Electronics PEFY-P-VMM-E, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Mitsubishi Electronics PEFY-P-VMM-E by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Mitsubishi Electronics PEFY-P-VMM-E.

A complete Mitsubishi Electronics manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Mitsubishi Electronics PEFY-P-VMM-E - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Mitsubishi Electronics PEFY-P-VMM-E, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Mitsubishi Electronics PEFY-P-VMM-E, that we can find in the current document
3. Tips how to use the basic functions of the device Mitsubishi Electronics PEFY-P-VMM-E - which should help us in our first steps of using Mitsubishi Electronics PEFY-P-VMM-E
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Mitsubishi Electronics PEFY-P-VMM-E
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Mitsubishi Electronics PEFY-P-VMM-E in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Mitsubishi Electronics PEFY-P-VMM-E?

Use the form below

If you did not solve your problem by using a manual Mitsubishi Electronics PEFY-P-VMM-E, ask a question using the form below. If a user had a similar problem with Mitsubishi Electronics PEFY-P-VMM-E it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)