  • Altinex MAX Series - page 1

    MATRIX SWITCHERS MANUAL PART NUMBER: 400-0047-004 PRODUCT REVISION: 2 MAX SERIES MATRIX SWITCHERS USER’S GUIDE ...

  • Altinex MAX Series - page 2

    MATRIX SWITCHERS 1 INTRODUCTION Altinex appreciates your purchase of the MAX Series Matrix Switcher. We are sure you will find it a reliable and useful product. Superior performance for the right price backed by solid technical and customer support is what we have to offer. The product you are holding in your hands is designed using state-of-the-ar ...

  • Altinex MAX Series - page 3

    MATRIX SWITCHERS 2 PRECAUTIONS/SAFETY WARNINGS 1 Please read this manual carefully before using your MAX Series Matrix Switcher. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your MAX Series Switcher and to prevent fire and shock hazard. Please read them carefully and heed all warnings. 1.1 GE ...

  • Altinex MAX Series - page 4

    MATRIX SWITCHERS 3 ABOUT YOUR MAX SERIES MATRIX SWITCHER 2 The Altinex MAX Series Matrix Switchers are designed to route multiple computers or video sources to multiple display devices in a wide range of audio/visual installations. The MAX Series line of matrix switchers is available in the following sizes: 4x2, 4x4, 8x2, 8x4. The bandwidth of 100 ...

  • Altinex MAX Series - page 5

    MATRIX SWITCHERS 4 Power Cord x 5-position Terminal Connector x 4-position Terminal Connector x DIAGRAM OF FRONT/BACK PANEL 4 ...

  • Altinex MAX Series - page 6

    MATRIX SWITCHERS 5 4.1 BACK PANEL CONTROL The MAX Series Matrix Switcher offers great flexibility in configuring the switcher. Each portion of the signal can be controlled independently or in any desired grouping. This allows use of the switcher with a variety of signal formats, and allows multiple independent switchers in one enclosure. For exampl ...

  • Altinex MAX Series - page 7

    MATRIX SWITCHERS 6 The computer video signal can be RGsB, RGBS, or RGBHV format. The broadcast video signal can be C-Video, S-Video, or Component Video in NTSC, PAL or SECAM standard. The audio signal can be Mono or Stereo. Depending on the signal and size configuration of the MAX Switcher, the back panel of the switchers will be different. Here ar ...

  • Altinex MAX Series - page 8

    MATRIX SWITCHERS 7 ...

  • Altinex MAX Series - page 9

    MATRIX SWITCHERS 8 ...

  • Altinex MAX Series - page 10

    MATRIX SWITCHERS 9 INSTALLING YOUR SWITCHER 6 Step 1. Connect the power entry connector of the MAX Switcher to the power outlet with the provided power cord. The power supply is universal and will work throughout the world with voltages between 90V-260V. Step 2. Connect the cables from the video sources (computers, VCR, others) to available inputs ...

  • Altinex MAX Series - page 11

    MATRIX SWITCHERS 10 In PRESS and HOLD mode the switcher performs secondary functions. Press and hold the button until all LED’s flash and the unit beeps a second time. In POWER-ON mode the switcher changes settings that are stored in the switcher’s memory. These modified settings become the default settings next time the unit is powered. The LE ...

  • Altinex MAX Series - page 12

    MATRIX SWITCHERS 11 Press and hold Input 5 and turn the power ON. Then wait for long and short beep to set the No sync delay function. Press and hold Input 6 and turn the power ON. Then wait for long and short beep to set a 5- second sync delay. Press and hold Input 7 and turn the power ON. Then wait for long and short beep to set a 2- second sync ...

  • Altinex MAX Series - page 13

    MATRIX SWITCHERS 12 RESET To reset the switcher to its factory default setting, press [VIDEO] and hold it until all LED’s flash. When the switcher is reset: - Baud rate is changed to 2400 bps. - Unit ID is selected to 1. - IR-Control mode is disabled. - Sync Delay is set to None. - All stored memories are cleared. LOCK / UNLOCK FRONT PANEL Someti ...

  • Altinex MAX Series - page 14

    MATRIX SWITCHERS 13 The [SETIDn] command is used for programming the switcher; it should not be used as a part of a program to operate the switcher. [CODEn] n=1 - Use [ ] as start and end code n=2 - Use ( ) as start and end code n=3 - Use {} as start and end code n=4 - Use :; as start and end code n=5 - Use <> as start and end code n=6 - Use ...

  • Altinex MAX Series - page 15

    MATRIX SWITCHERS 14 1. The number of outputs must be the same on all units to be looped. 2. Output offset is zero for all units. 3. The input offset must be set for all units except for the first one. The offset for the input should be the same as the last number of the previous unit 4. The number of inputs available on the second unit for a direct ...

  • Altinex MAX Series - page 16

    MATRIX SWITCHERS 15 [RSET] This command resets or initializes the switcher to the power-on condition. With this command, the baud rate is changed to 2400 bps, all current inputs from outputs are disconnected, unit ID number is set to 1, memory number 1 is recalled, and all levels (VIDEO & AUDIO) are enabled. [BAUDn] n=1(31hex) 300 baud n=2(32he ...

  • Altinex MAX Series - page 17

    MATRIX SWITCHERS 16 This command allows control of each signal level independently. Once issued it is active until another [SELn] command is issued or the front panel is used to control the switcher. When the front panel is used, the levels to be controlled are defined by the front panel selections. The front panel allows only 3 options of controll ...

  • Altinex MAX Series - page 18

    MATRIX SWITCHERS 17 This command is used to select multiple inputs and multiple outputs without switching and then switch them together with a single command. This is a very useful command for scene or salvo switching or for controlling through a PC. If n = 1, units will respond to any command. If n= 0, then none of the units will respond to any is ...

  • Altinex MAX Series - page 19

    MATRIX SWITCHERS 18 [SWUx] command will delay switching for that period. [FDBKn] n- 1 enable feedback [OK] or [ERR] n- 0 disable feedback This command sets MAX Switchers to provide feedback code during RS-232 control operations. Factory default is no feedback. After [FDBK1] is issued the MAX Series Switcher will provide an [OK] if the command is ex ...

  • Altinex MAX Series - page 20

    MATRIX SWITCHERS 19 7.6 IR-CONTROL MODE Wired Infra-red Receiver Step 1. Make sure that the MAX Switcher is in the OFF position. Step 2. Plug the 4-position terminal plug located at the end of the cable into RS-232 Port 1 located on the top-right corner on the backside of the switcher. Note: Inserting the 4-positon Terminal connector on RS-232 port ...

  • Altinex MAX Series - page 21

    MATRIX SWITCHERS 20 CABLES AND ACCESSORIES 8 Model No. Description RACK MOUNTING BRACKETS DA1296RM 19”-3U Rack Mount Ears TABLE MOUNT BRACKETS TM1277 3U High, 1 Rack - Wide CONTROL OPTIONS RC5251IR Infra-Red Hand-held Remote Control Transmitter and Receiver with 6 ft cable 4 BNC TO 4 BNC COAXIAL CABLE CB4100MR Bulk high resolution 4 coax cable (5 ...

  • Altinex MAX Series - page 22

    MATRIX SWITCHERS 21 port simultaneously. 8 Can I use contact closure to control the switcher? Contact closure cannot control the MAX Switcher directly, but this can be done using the Altinex CP7317RS unit, which is capable of converting contact closure control into RS-232 commands. The number of relays available limits the number of functions avail ...

  • Altinex MAX Series - page 23

    MATRIX SWITCHERS 22 ALTINEX POLICY 11 11.1 LIMITED WARRANTY Altinex warrants that its MAX Series Matrix Switchers are free from defects in materials under normal use and service. This warranty is limited to repairing at company’s factory any part or parts of the product, which upon company’s examination shall disclose to be, thus defective. Pro ...

Manufacturer Altinex Category Switch

Documents that we receive from a manufacturer of a Altinex MAX Series can be divided into several groups. They are, among others:
- Altinex technical drawings
- MAX Series manuals
- Altinex product data sheets
- information booklets
- or energy labels Altinex MAX Series
All of them are important, but the most important information from the point of view of use of the device are in the user manual Altinex MAX Series.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Altinex MAX Series, service manual, brief instructions and user manuals Altinex MAX Series. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Altinex MAX Series.

A complete manual for the device Altinex MAX Series, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Altinex MAX Series by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Altinex MAX Series.

A complete Altinex manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Altinex MAX Series - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Altinex MAX Series, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Altinex MAX Series, that we can find in the current document
3. Tips how to use the basic functions of the device Altinex MAX Series - which should help us in our first steps of using Altinex MAX Series
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Altinex MAX Series
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Altinex MAX Series in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Altinex MAX Series?

Use the form below

If you did not solve your problem by using a manual Altinex MAX Series, ask a question using the form below. If a user had a similar problem with Altinex MAX Series it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)