Manual Jotul GF 400 DV

32 pages 1.51 mb
Download

Go to site of 32

Summary
  • Jotul GF 400 DV - page 1

    1 Installation and Oper ation Instruc tions Jøtul GF 400 D V Sebago Gas Heater IF THE INFORMA TION IN THESE INSTRUCTIONS ARE NO T FOLLO WED EXACTL Y , A FIRE OR EXPLO- SION MA Y RESUL T CA USING PROPERTY D AMAGE, PERSONAL INJUR Y OR LOSS OF LIFE. FOR Y OUR SAFETY : DO NO T ST ORE OR USE GASOLINE OR O THER FLAMMABLE V APORS AND LIQUIDS IN THE VICIN ...

  • Jotul GF 400 DV - page 2

    2 W elc ome to J ø tul... Congr atulations on the purchase of your new Jøtul GF 400 DV Sebago Gas Hea ter . W e at Jøtul are glad you’ve made the decision to warm your hearth with a Jøtul product . Y our new GF 400 DV Sebago benefits from our experience gained o ver 150 years as the world’ s largest manuf acturer of solid fuel burning appli ...

  • Jotul GF 400 DV - page 3

    3 T able of Contents Service T ools .............................................. 3 Specifications ........................................... 4 General Inf ormation ............................... 5 Safety Inf ormation .................................. 6 Installation R equirements Location ................................................. 6 Hear ...

  • Jotul GF 400 DV - page 4

    4 Specifications GF 400 D V Sebago Specifications Input Rates Natur al Gas 32,000 BT U /hr . maximum input 18,000 BT U /hr . minimum input Propane 32,000 BTU /hr . maximum input 16,000 BT U /hr . minimum input Inlet P ressure: MI N M AX Natur al Gas: 5.0 WC (1.24 kP a) 7.0 W C (1.74 kPa) Propane: 12.0 W C (2.99 kP a) 14.9 W C (3.71 kP a) Manif old ...

  • Jotul GF 400 DV - page 5

    5 Hardwa re Bag Contents • Fuel Con version Kit - LP ................................ 155351 • Ember Bag , 4 oz. ............................................ 129123 Gener al Inf ormation  THIS H EA TER MUS T BE INS T ALLED AN D MAINT AIN ED BY A QU ALIFIED SERVICE AGENCY .  The installation and repair of this appliance must be done by a q ...

  • Jotul GF 400 DV - page 6

    6 Location In selecting a location f or the stove, c onsider the following poin ts: 1) Heat distribution 2) V ent termination requir ements 3) Gas supply line routing 4) T raf fic areas , furniture, draperies , etc . The GF 400 D V Sebago may be located on or near conv entional construction materials, however , proper clearance to c ombustibles mus ...

  • Jotul GF 400 DV - page 7

    7 Sto v e and V ent Clearance Requirements Minimum Clearances fr om the Stov e to Combustibles: See figs. 2-4. R ear: 2” (51 mm) C eiling: 32 1/4” (819 mm) C orner: 2” (51 mm) Sides: 3” (76 mm) Minimum Clearances fr om the V ent Pipe to Combustibles: Horiz ontal R un: Off the top of the pipe 2” (51 mm) Off the sides and bottom 1” (25 mm ...

  • Jotul GF 400 DV - page 8

    8 V ent Restric tion The GF 400 D V Sebago is equipped with R estrictor Plates which enable you to regula te the flow of incoming combustion air and exhaust gas. The plates pr eve nt overly str ong dra ft that can cause poor combustion and weak flame picture. F ollow the guidelines below , and on the following pages, to determine the correc t restr ...

  • Jotul GF 400 DV - page 9

    9 V er tical V ent T ermination The Jøtul GF 400 D V Sebago can be vertically vented through a ceiling or to a roof termination with the f ollowing guidelines:  The termination should fall within the shaded area s of the grids depicted in the V ent W indow diagrams on the pages 10-11.  Maximum V ertical run should not exceed 35 f t. (10.66 m ...

  • Jotul GF 400 DV - page 10

    10 HORIZONT AL RUN 35 Ft. (10.67 m) 30 Ft. (9.14 m) 25 Ft. (7.62 m) 20 Ft. (6.10 m) 15 Ft. (4.57 m) 5 Ft. (1.52 m) 10 Ft. (3.05 m) 5 Ft. (1.52 m) VERTICAL RUN 15 Ft. (4.57 m) 20 Ft. (6.09 m) 27 Ft. (8.22m) 12 Ft. (3.65 m) 8 Ft. (2.43 m) A D Min. Rise 2 Ft. (.60 m) B B A C Min. V ertical T ermination Up to four 45° or two 90° elbows permitted in a ...

  • Jotul GF 400 DV - page 11

    11 HORIZONT AL RUN 35 Ft. (10.67 m) 30 Ft. (9.14 m) 25 Ft. (7.62 m) 20 Ft. (6.10 m) 15 Ft. (4.57 m) 5 Ft. (1.52 m) Min. Rise 2 Ft. (.60 m) 10 Ft. (3.05 m) 5 Ft. (1.52 m) VERTICAL RUN 15 Ft. (4.57 m) 20 Ft. (6.09 m) 27 Ft. (8.22m) 12 Ft. (3.65 m) 8 Ft. (2.43 m) A B OPEN AIR INLET RESTRICTOR D B Up to four 45° or two 90° elbows permitted in additio ...

  • Jotul GF 400 DV - page 12

    12 C o-linear V ent Installation The GF 400 D V Sebago may be vented thr ough a ma- sonry or Class A pref abricated chimney using a C o-linear Flexible V en t system approved f or use with a solid-fuel burning fir eplace. When installed in the manner de- scribed below , this system can improv e the per formance of the appliance in cold climate situ ...

  • Jotul GF 400 DV - page 13

    13 Masonry or Pref abricated Chimney Co nv ersion The GF 400 D V Sebago is approv ed for use with listed chimney con version kits from any of the manuf acturers listed on page 8. These kits are f or use in a masonry chimney or a pr efabricated solid fuel listed chimne y . See fig. 15. These installation requirements must be followed: 1. Use the gui ...

  • Jotul GF 400 DV - page 14

    14 Horizontal T ermina tion  Any horizontal termination must f all within the shaded portion of the ve nt window graph illustr ated in figs. 9 or 11. For Snork el T erminations , see below .  Any horiz ontal termination ex cept a snorkel termination, must include: 1) Minimum rise of 2 ft. 2) Minimum horizontal run of 12 in. when vertical run ...

  • Jotul GF 400 DV - page 15

    15 Figure 19. V ent T erminal Clearances - National Fuel Gas C ode. Horizontal T ermination Clearance Figure 20. T ermination Clear ance to overhangs 3 76 mm 12  305 mm 2 1/2 64 mm A = Clearance abov e grade, ver anda, porch , deck, or balcony : 12 inches (30 cm) minimum. B = Clearance to window or door that may be opened: **Min. 9 inches, ...

  • Jotul GF 400 DV - page 16

    16 T ools required: • 1/2” open ended wrench or deep-well sock et, T orx T20 or slotted screwdriv er , 4 mm allen wrench. C onv ersion Kit Contents: • 1, regulator tower labeled for pr opane • 3, r egulator tower screw s • 1, burner orifice (#33 for NG, 1.65 mm for LPG) • 1, pilot orifice (#51 f or NG, #30 f or LPG) • Label A - to be ...

  • Jotul GF 400 DV - page 17

    17 Close Open Fuel C onv ersion Procedure R efer to fig. 47, Illustrated P arts Break down, to identify part numbers below . 1. T urn off gas supply to stove. 2. R emov e the stov e T op Pla te (41). 3. Disengage the two Glass Fr ame Latches at the top of the firebo x. See illustra tion on page 5. Carefully lif t the glass panel up and out of the s ...

  • Jotul GF 400 DV - page 18

    18 Gas Supply Connection Connect the gas supply line to the stov e, before installing the optional Blower . If the blower will be installed, use a 45° elbow of f the control v alv e to create clear ance required for the blower installation. The gas supply line connection is made to the left side of the valv e. The gas supply line should be 3/8&quo ...

  • Jotul GF 400 DV - page 19

    19 Gas Pressure Corr ect gas pressur e is essential for ef ficient and safe opera tion of the GF 400 DV Sebago gas sto ve. It is important that the corr ect pressur e is established at the time of the installation. Pr oper gas pressure provides a consistent flow of gas to the appliance and is instrumental in checking f or gas leaks. Pressure T est: ...

  • Jotul GF 400 DV - page 20

    20 Close Open Optional W all Thermostat or Remote C ontr ol Use only a 750 milliv olt DC two-wire circuit thermostat with this appliance. The thermostat should be placed in the same room as the heater , typically 5 feet off the floor . Av oid draf ty ar eas or any are a that may aff ect the accuracy of the thermostat . The thermostat should be conn ...

  • Jotul GF 400 DV - page 21

    21 Log Set Installation NO TE: If appropriate, install the optional Antique Brick Panel Kit befor e assembling the logset. The GF 400 D V Sebago logset must be installed before opera ting the burner . The logset includes fiv e log pieces, pack aged inside the firebox, and a quantity of ember stones pack aged in the Miscellaneous Parts bag . T o ins ...

  • Jotul GF 400 DV - page 22

    22 S y stem Check 1. PURGING THE GAS LI NE: When lighting the appli- ance f or the first time, it will tak e a f ew moments to clear the gas line of air . Once this purge is complete, the appliance will opera te as described in the lighting instructions. See the inside back cov er of this manual or the stove Ra ting Plate a ttached the bottom of th ...

  • Jotul GF 400 DV - page 23

    23 Oper ation F amiliarize y ourself with the controls of the GF 400 D V Sebago . Make sure that anyone else using the appliance is also familiar with the c ontrols and opera tion proce- dures. Alw a ys f ollow the Lighting Instructions on the inside back cov er of this manual and also located on the Ra ting Plate a ttached to the back of the stov ...

  • Jotul GF 400 DV - page 24

    24 Glass Care Clean the glass only when necessar y . W ipe the surface with a clean, dampened, soft cloth. Follow with a dry , soft towel. T ake care not to scra tch the glass sur face. WARNING: DO NO T USE ABRASIVE CLEANERS ON THE GLASS. NEVER CLEAN THE GLASS WHEN IT IS HOT . Gasket Inspection It is impor tant that the glass gasket be inspected at ...

  • Jotul GF 400 DV - page 25

    25 Optional Blower # 156000 Figure 43. Attach Snapstat and Blower Brackets.      THIS BLOWER MUST BE ELECTRICALL Y GROUNDED IN A CCORD ANCE WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES, WITH THE CURRENT ANSI/NFP A 70, NA TIONAL ELECTRICAL CODE OR CSA C22.1-CANADIAN ELECTRICAL CODE.      THIS UNIT IS SUPPLIED WITH ...

  • Jotul GF 400 DV - page 26

    26 Blower Oper ation The optional v ariable-speed blower will enhance heat circulation around the fir ebox and out into the room. The blower is controlled by a hea t ac tiv ated switch (snapstat) that will ON L Y function when the control switch is in A UT O setting. After the fir e has been burning for a time, the snapstat will reac t to the heat ...

  • Jotul GF 400 DV - page 27

    27 1. Remov e the T op Plate. Simply lift if up of f of the stove body . It is not fastened. 2. Remov e the Glass Frame. Disengage the two compression latches located a t the top of the firebox and lif t the glass frame up and off of the stov e. See Fig. 1. 3. Remov e the Logset. These parts are not fastened. Simply lif t them out of the firebo x. ...

  • Jotul GF 400 DV - page 28

    28 Figure 51. Illustr ated P arts Breakdown - GF400 D V Sebago GF 400 D V Sebago Illustr ated P arts Breakdown 14 13 12 47 46 11 10 9 8 7 6 5 4 3 2 1 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 20 15 19 18 17 16 48 49 50 51 57 52 53 54 55 56 59 58 21 60 61 62 63 64 56 Side-mount V alve shown. Center -mounted v alve uses ...

  • Jotul GF 400 DV - page 29

    29 1. Air Divider ................................................................... 220624 2. Simpson DuraV ent Collar ....................................... 129126 3. Collar Gaske t .............................................................. 129118 4. W ire Harness Assembly .......................................... 155397 5. Rating Pla te . ...

  • Jotul GF 400 DV - page 30

    30 MODEL NAME: ________________________ SERI AL NUM BE R: ______________________ D A TE OF PURC HASE: ___________________ PURC HASED FR OM: ____________________ NAME OF IN ST ALLER: ___________________ TYPE OF FUEL: ________________________ W AS S T O VE C ONVER TED? _______________ NO TES: GF 400 DV Sebago R ecor d the following informa tion to he ...

  • Jotul GF 400 DV - page 31

    31 3. Access the lower controls. 4. Depress gas c ontrol knob slightly and turn clock - wise to “OFF” . Do not force. FOR Y OUR SAFETY , READ BEFORE LIGHTING . LIGHTING INSTR UCTIONS T O TURN OFF GAS T O THE APPLIANCE: LIGHTING INSTRUCTIONS WARNING: IF Y OU DO NOT FOLL OW THESE INSTR UCTIONS EXA CTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING ...

  • Jotul GF 400 DV - page 32

    32 Jøtul AS P .O . B ox 1411 N-1602 Fr edrikstad Norway Jøtul North America 55 Hutcherson Dr . Gorham, ME 04038-2634 November 2005 137750-E This appliance must be installed in conformance with local and national building r egulations. Bef ore beginning the installation, it is important that the these instructions be carefully read and understood. ...

Manufacturer Jotul Category Electric Heater

Documents that we receive from a manufacturer of a Jotul GF 400 DV can be divided into several groups. They are, among others:
- Jotul technical drawings
- GF 400 DV manuals
- Jotul product data sheets
- information booklets
- or energy labels Jotul GF 400 DV
All of them are important, but the most important information from the point of view of use of the device are in the user manual Jotul GF 400 DV.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Jotul GF 400 DV, service manual, brief instructions and user manuals Jotul GF 400 DV. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Jotul GF 400 DV.

Similar manuals

A complete manual for the device Jotul GF 400 DV, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Jotul GF 400 DV by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Jotul GF 400 DV.

A complete Jotul manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Jotul GF 400 DV - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Jotul GF 400 DV, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Jotul GF 400 DV, that we can find in the current document
3. Tips how to use the basic functions of the device Jotul GF 400 DV - which should help us in our first steps of using Jotul GF 400 DV
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Jotul GF 400 DV
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Jotul GF 400 DV in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Jotul GF 400 DV?

Use the form below

If you did not solve your problem by using a manual Jotul GF 400 DV, ask a question using the form below. If a user had a similar problem with Jotul GF 400 DV it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)