    Y eoman Exe Midi Conventional Flue Coal Effect Stove With upgradeable control valve Instructions for Use, Installation and Servicing For use in GB, IE (Great Britain and Eire) PR1 145 Issue 1 (July 2010) IMPORTANT This product contains a Heat resistant glass panel. This panel should be checked during Installation and at each servicing interval. If ...

  • Yeoman PR1145 - page 2

    2 CONTENTS COVERING THE FOLLOWING MODELS: YM-N9171FL / YM-N9171LC YM-P9171FL / YM-P9171LC PAGE APPLIANCE COMMISSIONING CHECKLIST 3 USER INSTRUCTIONS 4 INSTALLATION INSTRUCTIONS 9 Technical Specification 9 Site Requirements 10 Installation 11 Commissioning 14 SERVICING INSTRUCTIONS 15 Servicing Requirements 15 Fault Finding 15 How to replace parts 1 ...

  • Yeoman PR1145 - page 3

    3 FLUE CHECK PASS FAIL 1. Flue is correct for appliance 2. Flue flow test 3. Spillage test GAS CHECK 1. Gas soundness & let by test 2. Standing pressure test mb 3. Appliance working pressure (on High Setting) mb NB All other gas appliances must be operating on full 4. Gas rate m 3 /h 5. Does ventilation meet appliance requirements 6. Have contr ...

  • Yeoman PR1145 - page 4

    4 USER INSTRUCTIONS 1.7 The manufacturer considers the full outer casing of this stove to be a working surface which becomes hot when the stove is lit. A suitable guard is recommended to protect young children, the aged and the infirm. 1.8 This stove must only be operated with the door secured firmly in position. If any cracks appear in the glass t ...

  • Yeoman PR1145 - page 5

    5 2. LIGHTING THE STOVE 2.1 The control valve is on the right-hand side at the foot of the stove. It has two controls: — The right-hand knob controls the pilot ignition — The left-hand knob controls the main burner 2.2 Refer to separate instructions if your stove is upgraded to include battery remote control. The following instructions apply wh ...

  • Yeoman PR1145 - page 6

    6 5. CLEANING THE STOVE Advice on Handling and Disposal of Fire Ceramics 5.1 The fuel effect logs and embers in this stove are made from Refractory Ceramic Fibre (RCF). Protective clothing is not required when handling these articles, but we recommend you follow normal hygiene rules of not smoking, eating or drinking in the work area and always was ...

  • Yeoman PR1145 - page 7

    7 HEADING 6. FUEL BED ARRANGEMENT 6.1 Place the flame baffle onto the burner and push against the rear tray lip (see Diagram 5). AR0359 5 Spacer brackets 6.2 Locate the rear panel against the spacer brackets (see Diagram 3) and slide down so that it locates on the ledge of the flame baffle (see Diagram 6). AR0360 6 6.3 Place the log retainer in the ...

  • Yeoman PR1145 - page 8

    8 AR0364 11 6.8 Replace the glass frame using the 6 x frame fixing screws (see Diagram 4) and close door. 7. GAZCO FLUE SURE SYSTEM The stove is fitted with the Gazco Flue Sure System, which will act to cut off the gas supply to the burners in the event of incorrect operation of the flue. If the system acts to cut off the gas supply, this indicates ...

  • Yeoman PR1145 - page 9

    9 INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION Covering the following models: Yeoman Exe Midi YM-N9171FL / YM-N9171LC YM-P9171FL / YM-P9171LC 1 x Stove 1 x Flue infill plate 1 x Front coal 1 x Flame baffle 1 x Coal set 1 x Rear ceramic 1 x Fixing kit containing: 1 x Instruction manual 2 x Wood screws 2 x Wall plugs 1 x Hexagon key Model Gas CA ...

  • Yeoman PR1145 - page 10

    C A B A = 643mm B = 43mm C = 12mm AR0604 1 4.2 This appliance must not be installed in a room that contains a bath or shower. 4.3 The stove is not suitable for installation against a combustible wall; all combustible materials must be removed from the area behind the stove. 4.4 Ensure that all minimum clearances to combustible materials are complie ...

  • Yeoman PR1145 - page 11

    11 2.7 The stove is fitted with the Gazco Flue Sure System , which will act to cut off the gas supply to the appliance in the event of incorrect operation of the flue. If the system acts to shut off the gas supply, this indicates that there is insufficient flue pull. If this occurs, a minimum of 10 minutes should be allowed before trying to relight ...

  • Yeoman PR1145 - page 12

    12 3.5 Check the pull of the flue system by applying a lighted smoke pellet to the flue system opening. If there is a definite flow into the chimney, proceed with the installation, if not warm the chimney for a few minutes. IF THERE IS STILL NO DEFINITE FLOW, THE FLUE MAY REQUIRE ATTENTION - SEEK EXPERT ADVICE. 3.6 The flue system may now be connec ...

  • Yeoman PR1145 - page 13

    13 AR0360 8 4.8 Place the log retainer in the two guides as shown in Diagram 9. AR2076 9 FOR CLARITY, THE FOLLOWING LOG ARRANGEMENT DIAGRAMS DO NOT INCLUDE ILLUSTRATION OF THE RETAINER. 4.9 Locate the front coal between the heat shield and the flame baffle so that the ends sit flat against the burner skin (see Diagram 10). AR0361 10 4.10 Place five ...

  • Yeoman PR1145 - page 14

    14 INSTALLATION INSTRUCTIONS COMMISSIONING 1. COMMISSIONING After connecting the gas pipe to the stove: 1.1 PURGE THE SUPPLY PIPE to dispel any debris that might block the controls. 1.2 Connect the gas supply to the 8mm compression elbow at the right-hand rear corner of the stove (see Diagram 1). AR0934 1 1.3 Connect a suitable pressure gauge to th ...

  • Yeoman PR1145 - page 15

    15 IGNITION FUNCTIONAL CHECK 1 PILOT WILL NOT LIGHT Ensure there is no debris around the pilot assembly, (e.g. soot, etc.) which could short the spark, clean the area. Operate the valve. Is there a spark? Consult Section 2 and retry. Check alignment of pilot burner head, change the ignition lead, see Diagram 1 on page 14. Check isolation tap and ga ...

  • Yeoman PR1145 - page 16

    16 PILOT WILL NOT STAY LIT OR FIRE GOES OUT IN USE Ensure there is no debris around the pilot assembly, e.g. coal, soot etc. which could short the spark, clean the area. Problem is with the pipe work or fittings which lead to the fire. Correct and retry. Is thermocouple connection good in back of valve? Replace thermocouple. Will pilot stay alight? ...

  • Yeoman PR1145 - page 17

    17 2.4 Remove the two screws at the back of the firebox and lift the burner unit clean (see Diagram 3). AR1442 3 3. PILOT UNIT 3.1 Follow the procedure for removing the main burner (see Section 2 ) when the burner is removed from the stove, remove the aeration cover by undoing the two screws (see Diagram 4). AR1443 4 3.2 Remove the lint arrestor by ...

  • Yeoman PR1145 - page 18

    18 3.3 The pilot unit can now be removed by undoing the two screws (see Diagram 6). AR1445 6 3.4 Reassemble in reverse order, do not overtighten. NOTE: SPECIAL CARE SHOULD BE TAKEN WHEN REPLACING THE THERMOCOUPLE TO THE BACK OF THE GAS VALVE TO ENSURE THAT THE SENSOR WIRES FOR THE GAZCO FLUE SURE SYSTEM ARE NOT DISCONNECTED. 4. IGNITION LEAD AND PI ...

  • Yeoman PR1145 - page 19

    19 6.3 Undo the single screw that secures the left hand side of the control cover (see Diagram 10). 10 AR0915 6.4 To release the right hand side of the control cover insert the narrow blade screwdriver into the slot shown in Diagram 11. Lever it gently and pull from the right hand side at the same time. The cover will now come off. There is a small ...

  • Yeoman PR1145 - page 20

    20 9. GAZCO FLUE SURE SYSTEM 9.1 Open the door and remove the ceramics, placing them carefully to one side. Undo the two screws in the back of the firebox and carefully withdraw the bracket (see Diagram 14). AR1442 14 9.2 Disconnect the two sender wires. Undo the two taptite screws and remove the sensor and the two plastic spacers (see Diagram 15). ...

  • Yeoman PR1145 - page 21

    21 11. CHANGING BETWEEN GAS TYPES In order to change between gas types it will be necessary to change the following items: - Pilot Unit - Control Valve** - Main Injector - Aeration Plate - Data Badge The relevant parts can be ordered from Gazco. Always quote the appliance type and serial number when ordering spare parts. ** NOTE: THE CONTROL VALVE ...

  • Yeoman PR1145 - page 22

    22 SERVICE RECORDS 1ST SERVICE 2ND SERVICE Date of Service: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Date of Service: ................................. Next Service due: ............................... N e x t S e r v i c e d u e : ............................... Signed: ....................................... S i g n e d : . ...

  • Yeoman PR1145 - page 23

    A division of Stovax Ltd Falcon Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7LF Tel: (01392) 474500 Fax: (01392) 219932 E-mail: yeoman@stovax.com www.yeoman-stoves.co.uk ...

Manufacturer Yeoman Category Stove

Documents that we receive from a manufacturer of a Yeoman PR1145 can be divided into several groups. They are, among others:
- Yeoman technical drawings
- PR1145 manuals
- Yeoman product data sheets
- information booklets
- or energy labels Yeoman PR1145
All of them are important, but the most important information from the point of view of use of the device are in the user manual Yeoman PR1145.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Yeoman PR1145, service manual, brief instructions and user manuals Yeoman PR1145. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Yeoman PR1145.

Similar manuals

A complete manual for the device Yeoman PR1145, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Yeoman PR1145 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Yeoman PR1145.

A complete Yeoman manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Yeoman PR1145 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Yeoman PR1145, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Yeoman PR1145, that we can find in the current document
3. Tips how to use the basic functions of the device Yeoman PR1145 - which should help us in our first steps of using Yeoman PR1145
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Yeoman PR1145
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Yeoman PR1145 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Yeoman PR1145?

Use the form below

If you did not solve your problem by using a manual Yeoman PR1145, ask a question using the form below. If a user had a similar problem with Yeoman PR1145 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)