  • Dimplex S1 7KS - page 1

    1 INST ALLA TION and OPERA TING INSTRUCTIONS Brine-to-W ater Heat Pump for Indoor Installation SI 1 1KS SI 14KS SI 7KS SI 9KS CE Order No.: 452231.67.01 FD 8504 ...

  • Dimplex S1 7KS - page 2

    2 CONTENTS 1 PLEASE READ IMMEDIA TEL Y 3 1.1 Important Information 1.2 Legal Provisions and Directives 1.3 Energy-Efficient Use of the Heat Pump 2 PURPOSE OF THE HEA T PUMP 4 2.1 Application 2.2 Principle of Operation 3 BASELINE UNIT 4 4 ACCESSORIES 5 4.1 Brine Manifold 4.2 Brine Pressostat 5 TRANSPORT 5 6 INST ALLA TION 6 6.1 General Information 6 ...

  • Dimplex S1 7KS - page 3

    3 READ IMMEDIA TEL Y 1.1 Important Information The heat pump is not secured to the wooden pallet. The heat pump must not be tilted more than max. 45° (in either direction). Do not lift unit by the holes in the panel assemblies! In the case of large-capacity heating circuits, the installed expansion vessel (24 litres, 1.0 bar admission pressure) mu ...

  • Dimplex S1 7KS - page 4

    4 3 2 PURPOSE OF HEA T PUMP BASELINE UNIT PURPOSE OF THE HEA T PUMP 2.1 Application The brine-to-water heat pump is designed for use in existing or newly built heating systems. Brine is used as the heat carrier in the heat source system. Ground coils, ground collectors or similar systems can be used as the heat source. 2.2 Principle of Operation Th ...

  • Dimplex S1 7KS - page 5

    5 5 4 ACCESSORIES 4.1 Brine Manifold The brine manifold ties the individual collector loops of the heat source system into a single main line which is connected to the heat pump. Integrated ball valves allow individual brine circuits to be shut off for venting purposes. ACCESSORIES TRANSPORT TRANSPORT A lift truck is suited for transporting the uni ...

  • Dimplex S1 7KS - page 6

    6 MOUNTING 7.1 General The following connections need to be established on the heat pump: - supply/return flow of the brine system - supply/return flow of the space heating and water heating system - common return of space heating and water heating system - return, overflow valve - connection for additional expansion vessel (as required) - drain li ...

  • Dimplex S1 7KS - page 7

    7 CAUTION! MOUNTING pump installations where a power failure cannot readily be detected (e.g. holiday houses), the heating circuit must contain a suitable antifreeze product. The integrated expansion vessel has a capacity of 24 litres.This capacity is appropriate for buildings with a heated living space floor area of up to 200 m 2 . The planner of ...

  • Dimplex S1 7KS - page 8

    8 9 COMMISSIONING CARE/CLEANING COMMISSIONING 8.1 General T o ensure proper commissioning it should be carried out by an after-sales service authorised by the manufacturer . Only then can an extended warranty period of 3 years in total be granted (cf. Warranty service). 8.2 Preparatory Steps Prior to commissioning, the following items need to be ch ...

  • Dimplex S1 7KS - page 9

    9 10 CAUTION! 11 According to current knowledge, we recommend cleaning with a 5% phosphoric acid solution or , in the case that cleaning needs to be performed more frequently , with a 5% formic acid solution. In either case, the cleaning fluid should be at room temperature. It is recommended that the heat exchanger be cleaned in the direction oppos ...

  • Dimplex S1 7KS - page 10

    10 APPENDIX 12 12.1 DIMENSIONED DRAW- ING 1 1 12. 2 EQUIPMENT D A T A 12 12 .3 SCHEMA TICS 12.3.1 Characteristics .. 7KS 1 3 12.3.2 Characteristics .. 9KS 1 4 12.3.3 Characteristics .. 1 1KS 1 5 12.3.4 Characteristics .. 14KS 1 6 12. 4 WIRING DIAGRAMS 12.4.1 Control .. 7KS to .. 14KS 1 7 12.4.2 Load .. 7KS to .. 14KS 1 8 12.4.3 T erminal Diagram .. ...

  • Dimplex S1 7KS - page 11

    11 APPENDIX: 12.1 DIMENSIONED DRAWING Dimensioned Drawing 12. 1 Maßbilder 12. 1 Maßbilder 12. 1 Maßbilder 12. 1 Maßbilder 12. 1 Maßbilder Heating circuit pressure gauge Brine circuit pressure gauge Heat source Heat pump inlet 1 1/4" external thread Heat source Heat pump outlet 1 1/4" external thread Heating water flow Heat pump outle ...

  • Dimplex S1 7KS - page 12

    12 APPENDIX: 12.2 EQUIPMENT D A T A Equipment Data EQUIPMENT DATA for Brine-to-Water Heat Pumps for Heating 1 TYPE AND COMMERCIAL DESCRIPTION ..7KS ..9KS ..11KS ..14KS 2 MODEL 2.1 Type compact compact compact compact 2.2 Enclosure type acc. to EN 60 529 IP 20 IP 20 IP 20 IP 20 2.3 Installation site indoors indoors indoors indoors 3 PERFORMANCE DATA ...

  • Dimplex S1 7KS - page 13

    13 12.3.1 Characteristics .. 7KS APPENDIX: 12.3 SCHEMA TICS 0 2 4 6 8 10 12 - 1 0 - 5 0 5 1 01 52 02 53 0 Brine inlet temperature in [°C] Heating capacity in [kW] 35 50 Water outlet temperature in [°C] 0 0,5 1 1,5 2 2,5 - 1 0 - 5 0 5 1 01 52 02 53 0 Brine inlet temperature in [°C] Power consumption (incl. power input to pump) 50 35 0 1 2 3 4 5 6 ...

  • Dimplex S1 7KS - page 14

    14 12.3.2 Characteristics .. 9KS APPENDIX: 12.3 SCHEMA TICS 0 2 4 6 8 10 12 14 16 18 - 1 0 - 5 0 5 1 01 52 02 53 0 Brine inlet temperature in [°C] Heating capacity in [kW] 35 50 Water outlet temperature in [°C] 0 0,5 1 1,5 2 2,5 3 3,5 - 1 0 - 5 0 5 1 01 52 02 53 0 Brine inlet temperature in [°C] Power consumption (incl. power input to pump) 50 3 ...

  • Dimplex S1 7KS - page 15

    15 12.3.3 Characteristics .. 1 1KS APPENDIX: 12.3 SCHEMA TICS 0 2 4 6 8 10 12 14 16 18 20 - 1 0 - 5 0 5 1 01 52 02 53 0 Brine inlet temperature in [°C] Heating capacity in [kW] 35 50 Water outlet temperature in [°C] 0 0,5 1 1,5 2 2,5 3 3,5 4 - 1 0 - 5 0 5 1 01 52 02 53 0 Brine inlet temperature in [°C] Power consumption (incl. power input to pum ...

  • Dimplex S1 7KS - page 16

    16 12.3.4 Characteristics .. 14KS APPENDIX: 12.3 SCHEMA TICS 0 5 10 15 20 25 - 1 0 - 5 0 5 1 01 52 02 53 0 Brine inlet temperature in [°C] Heating capacity in [kW] 35 50 Water outlet temperature in [°C] 0 1 2 3 4 5 - 1 0 - 5 0 5 1 01 52 02 53 0 Brine inlet temperature in [°C] Power consumption (incl. power input to pump) 50 35 0 1 2 3 4 5 6 7 8 ...

  • Dimplex S1 7KS - page 17

    17 12.4.1 Control .. 7KS to .. 14KS APPENDIX: 12.4 WIRING DIAGRAMS Mains power supply ...

  • Dimplex S1 7KS - page 18

    18 12.4.2 Load .. 7KS to .. 14KS APPENDIX: 12.4 WIRING DIAGRAMS Mains power supply Soft starter not available in brine-to-water unit 7KS ...

  • Dimplex S1 7KS - page 19

    19 Mains power supply Mains power supply or Utility company disable contactor Contact open = HP disabled The function of the back-up heater can be selected 2 nd disable input Contact open = HP disabled factory-wired to be field-connected, if required 12.4.3 T erminal Diagram .. 7KS to .. 14KS APPENDIX: 12.4 WIRING DIAGRAMS ...

  • Dimplex S1 7KS - page 20

    20 12.4.4 Legend .. 7KS to .. 14KS APPENDIX: 12.4 WIRING DIAGRAMS A 1 Wire jumper , must be inserted if no utility company disable contactor is required A2 Wire jumper , must be removed if 2nd disable input is used B3 * Thermostat, hot water B4 * Thermostat, swimming pool water E9 * Electric immersion heater , hot water E10* Back-up heater (boiler ...

  • Dimplex S1 7KS - page 21

    21 Hydraulic Block Diagram APPENDIX: 12.5 HYDRAULIC BLOCK DIAGRAM Check valve Shut-off valve Overflow valve Safety assembly Circulating pump Expansion vessel Thermostat/manual valve Shut-off valve with check valve Heat consumer T emperature sensor Flexible connecting hose Back-up heater Primary circulating pump Heating circulating pump Hot water ci ...

  • Dimplex S1 7KS - page 22

    22 APPENDIX: 12.6 EC DECLARA TION OF CONFORMITY EC Declaration of Conformity Declaration of Conformity The undersigned Glen Dimplex Deutschland GmbH Division Dimplex Am Goldenen Feld 18 D-95326 Kulmbach her eby confirm that the design and construction of the pr oduct(s) listed below , in the version(s) placed on the market by us, conform to the r e ...

  • Dimplex S1 7KS - page 23

    23 Notes ...

  • Dimplex S1 7KS - page 24

    24 Glen Dimplex Deutschland GmbH Subject to technical modifications Division Dimplex Fax +49 92 21/709-589 Am Goldenen Feld 18 ww w .dimplex.de D-95326 Kulmbach ...

Manufacturer Dimplex Category Heat Pump

Documents that we receive from a manufacturer of a Dimplex S1 7KS can be divided into several groups. They are, among others:
- Dimplex technical drawings
- S1 7KS manuals
- Dimplex product data sheets
- information booklets
- or energy labels Dimplex S1 7KS
All of them are important, but the most important information from the point of view of use of the device are in the user manual Dimplex S1 7KS.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Dimplex S1 7KS, service manual, brief instructions and user manuals Dimplex S1 7KS. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Dimplex S1 7KS.

Similar manuals

A complete manual for the device Dimplex S1 7KS, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Dimplex S1 7KS by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Dimplex S1 7KS.

A complete Dimplex manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Dimplex S1 7KS - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Dimplex S1 7KS, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Dimplex S1 7KS, that we can find in the current document
3. Tips how to use the basic functions of the device Dimplex S1 7KS - which should help us in our first steps of using Dimplex S1 7KS
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Dimplex S1 7KS
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Dimplex S1 7KS in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Dimplex S1 7KS?

Use the form below

If you did not solve your problem by using a manual Dimplex S1 7KS, ask a question using the form below. If a user had a similar problem with Dimplex S1 7KS it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)