    485SDD16-1005 Manual Cover Page B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 RS-485 Digital I/O Module Model 485SDD16 Document ation Num ber 485SDD16-1005 pn#3605-r1 This product Designed and Manufactured In Ottawa, Il lin ois USA of domestic and imported pa rts by B&B Electronics Mfg. Co. ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 2

    485SDD16-1005 Manual Table of Contents i B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 Table of Contents Chapter 1 - Introduction ........................................... 1 485SDD16 Features ............................... ................ 1 Packing List ................................. .... ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 3

    485SDD16-1005 Manual 1 B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 Chapter 1- Introduction 485SDD16 Features The 485SDD16 is a genera l purpose control module t hat operates through an RS-485 inte rface. The 485SDD16 offers 16 discrete digital I/ O lines. With the se features, the mo dule can ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 4

    485SDD16-1005 Manual 3 B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 Power Supply Input Voltage: 8 Vdc to 16 Vdc @ 35 milliamps (Doesn’t include the power consumption of external devices.) Connection: Terminal Blocks or DB-25S Communications Standard: RS-422/485 Addresses: 256 (Factory default ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 5

    485SDD16-1005 Manual 5 B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 Chapter 2 - Connections This chapter will cover the connections re quired for the 485SDD16. There are three sets of conne ctions: digital I/O, serial port, and power supply. Do not make any connections to the 485SDD16 until you ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 6

    485SDD16-1005 Manual 7 B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 Figure 2.1 - Example of Multi-Node Network 485SDD16 485SDD16 485SDD16 Figure 2.2 - RS-485 2-wire Connection 8 485SDD16-1005 Manual B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5 ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 7

    485SDD16-1005 Manual 9 B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 Chapter 3 - Commands There are only two commands required to control the 485S DD16: set output l ines, and read I/O lines. Five additional commands are used for configuring the module: set module addr ess, set turn- around dela ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 8

    485SDD16-1005 Manual 11 B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 A byte represents an eight-bit binary number (11111111), therefore each byte can repre sent eight I/O lines. Each bit is assigned a bit position and a weight (value ). Refer to Table 3.3. Table 3.3 - Bit Assignments for I/O Li ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 9

    485SDD16-1005 Manual 13 B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 Set Module Address Command The Set Module Address command is used to change the address of a 485SDD16. This commands requires one data byt e. This data byte is used to specify the module's new address. Addresses can be as ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 10

    485SDD16-1005 Manual 15 B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 Set Power-up States Command The Set Power-up States command is used to set the states of output lines when the module's power is recycled. This command requires two data bytes. These data by tes specify the output state o ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 11

    485SDD16-1005 Manual 17 B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 Chapter 4 - I/O Interfacing This chapter will explain "HIG H" and "LOW" st ates and show some gene ral examples of how to int erface to t he I/O lines. C aution must be taken not to exceed 485SDD16 specific ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 12

    485SDD16-1005 Manual 19 B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 Figure 4.4 - Isolated Solid State Input Digital Outputs Digital outputs are used to turn on or turn off external devices. Digital outputs are CMOS compatible and op erate between 0Vdc and +5Vdc. Out puts can be used to control ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 13

    485SDD16-1005 Manual 21 B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 Chapter 5 - Software This chapter will be divided into two sections. The first section covers programming techni ques for constructing a command string, receiving data and manipulatin g data in QuickBASIC. The second section d ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 14

    485SDD16-1005 Manual 23 B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 Step 3 - Receiving the data: MSdefs$ = INPUT$(1,#1) LSdefs$ = INPUT$(1,#1) MSpups$ = INPUT$(1,#1) LSpups$ = INPUT$(1,#1) Maddr$ = INPUT$(1,#1) Mtdly$ = INPUT$(1,#1) Step 4 - Mani pulating the data : MSdefs = ASC(MSdefs$) LSdef ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 15

    485SDD16-1005 Manual 25 B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 Step 1b - Set appropriat e outputs LOW MSstates = MSstates AND (NOT(mask)) LSstates = LSstates AND (NOT(mask)) By "ANDing" the current states with the comp lement of the appropriate mask of a digit al output line, th ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 16

    485SDD16-1005 Manual 27 B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 Step 1b - Set appropriat e outputs power-up states LOW MSpups = MSpups AND (NOT(m ask)) LSpups = LSpups AND (NOT(mask)) By "ANDing" the current power-up states wit h the complement of the appropriate mask of a digita ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 17

    485SDD16-1005 Manual 29 B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 Demonstration Program The 485SDD16 Demonstration (SDD16) Program (IBM PC or Compatible) provides t he user with examples of how to receive and transmit commands to the 485SDD16. The SDD16.EXE is the executable program, the SDD ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 18

    485SDD16-1005 Manual Appendix A A-1 B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 APPENDIX A ASCII Character Codes A-2 Appendix A 485SDD16-1005 Manual B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 Decimal ASCII 0 .............. ..... NU L 1 . ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 19

    485SDD16-1005 Manual Appendix A A-3 B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 Decimal ............ ASC II 80 ............... .. P 81 ............... .. Q 82 ............... .. R 83 ............... .. S 84 ............... .. T 85 ............... .. U 86 ............... .. V 87 ............... ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 20

    485SDD16-1005 Manual Appendix B B-1 B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 APPENDIX B Hexadecimal/Decimal Conversions B-2 Appendix B 485SDD16-1005 Manual B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 The decimal (base 10) numbe ring sy ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 21

    485SDD16-1005 Manual Appendix B B-3 B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 Hexadecimal to Decimal Conv ersion: Decimal = (1st Hex digit x 4 096) + (2nd Hex digit x 256) + (3rd Hex digit x 16) + (4th Hex digit) Each "Hex digit" is the decimal equiv alent value of the hexadecimal ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 22

    485SDD16-1005 Manual A ppe ndix C C-1 B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 APPENDIX C Interface Modules for SDD16 Models C-2 Appendix C 485SDD16-1005 Manual B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 DTB25 The DTB25 connects to th ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 23

    485SDD16-1005 Manual A ppe ndix C C-3 B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 DBM16 The DBM16 module provides buffering and increased power handling for all t he sixteen I/O lin es of the SDD16 models. Each of the I/O lines can be programmed as an input or as an output by setting a jumper ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 24

    485SDD16-1005 Manual A ppe ndix C C-5 B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 Figure C.2 - DBM16 Outline Drawing Inputs Digital inputs are used to sense "HIGH" and "LOW" states based on voltage levels. This is accomplished via switch closures, contact closures or a soli ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 25

    485SDD16-1005 Manual A ppe ndix C C-7 B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 Outputs Digital outputs are used to turn "ON" or turn "O FF" external devices. Outputs can be used to control solid sta te output modules, logic circuits, and relays. Caution must be taken no ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 26

    485SDD16-1005 Manual A ppe ndix C C-9 B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 Figure C.10 - DBM16 Schematic C-10 Appendix C 485SDD16-1005 Manual B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 27

    485SDD16-1005 Manual Appendix D D-1 B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 APPENDIX D Adding Data Field Comfirmation D-2 A ppe ndix D 485SDD16-1005 Manual B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 With serial communications in a la ...

  • B&B Electronics RS-485 Digital I/O Module 485SDD16 - page 28

    485SDD16-1005 Manual Appendix D D-3 B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815 ) 433-5104 Table D-1 Extended Commands Function Command Response Read I/O Lines #{addr}RD {I/O msb}{~I/O msb}{I/O lsb}{~I/O lsb} Set Output Lines #{addr}SO{I/O msb}{~I/O msb}{ I/O lsb}{~I/O lsb} no response Set Module Address ...

Manufacturer B&B Electronics Category Network Card

Documents that we receive from a manufacturer of a B&B Electronics RS-485 Digital I/O Module 485SDD16 can be divided into several groups. They are, among others:
- B&B Electronics technical drawings
- RS-485 Digital I/O Module 485SDD16 manuals
- B&B Electronics product data sheets
- information booklets
- or energy labels B&B Electronics RS-485 Digital I/O Module 485SDD16
All of them are important, but the most important information from the point of view of use of the device are in the user manual B&B Electronics RS-485 Digital I/O Module 485SDD16.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals B&B Electronics RS-485 Digital I/O Module 485SDD16, service manual, brief instructions and user manuals B&B Electronics RS-485 Digital I/O Module 485SDD16. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product B&B Electronics RS-485 Digital I/O Module 485SDD16.

A complete manual for the device B&B Electronics RS-485 Digital I/O Module 485SDD16, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use B&B Electronics RS-485 Digital I/O Module 485SDD16 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of B&B Electronics RS-485 Digital I/O Module 485SDD16.

A complete B&B Electronics manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual B&B Electronics RS-485 Digital I/O Module 485SDD16 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the B&B Electronics RS-485 Digital I/O Module 485SDD16, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the B&B Electronics RS-485 Digital I/O Module 485SDD16, that we can find in the current document
3. Tips how to use the basic functions of the device B&B Electronics RS-485 Digital I/O Module 485SDD16 - which should help us in our first steps of using B&B Electronics RS-485 Digital I/O Module 485SDD16
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with B&B Electronics RS-485 Digital I/O Module 485SDD16
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of B&B Electronics RS-485 Digital I/O Module 485SDD16 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning B&B Electronics RS-485 Digital I/O Module 485SDD16?

Use the form below

If you did not solve your problem by using a manual B&B Electronics RS-485 Digital I/O Module 485SDD16, ask a question using the form below. If a user had a similar problem with B&B Electronics RS-485 Digital I/O Module 485SDD16 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)