Manual Linksys SLM2008

32 pages 2.49 mb
Download

Go to site of 32

Summary
  • Linksys SLM2008 - page 1

    USER GUIDE BUSINESS SERIES 5-P or t and 8-P or t 10/100/1000 Gigabit Smar t S witch with PD and A C P o w er Model: SLM2005, SLM2008 ...

  • Linksys SLM2008 - page 2

    i About This Guide 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er About T his Guide Icon Descriptions While reading thr ough the User Guide y ou may encount er various icons designed to call attention to a specific item. Below is a description of these icons: NO TE: This checkmark indica tes tha t ther e is a not e of i ...

  • Linksys SLM2008 - page 3

    ii T able of Contents 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Chapter 1: Introduction 1 Chapter 2: Product O verview 2 F ront P anel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Back P anel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Linksys SLM2008 - page 4

    iii T able of Contents 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Multicast > IGMP Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Admin > P ing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Ping P aramet ers . . . ...

  • Linksys SLM2008 - page 5

    1 Introduc tion 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Chapter 1 Chapter 1: Intr oduc tion The 5-port and 8-por t 10/100/1000 Gigabit Smart Switches with PD and A C P ow er allow you t o upgrade your existing 10/100 network by r eplacing y our current workgr oup hub or switch. At the same time, you can configure ...

  • Linksys SLM2008 - page 6

    2 Produc t Over view 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Chapter 2 Chapter 2: Pr oduct O verview Front P anel The LEDs are locat ed on the front panel of the Swit ch. Fr ont P anel - SLM2008 Sy stem (Green) Lights up green to indicate that power is being supplied to the S witch. 1-5 or 1-8 (Green) Each LED wi ...

  • Linksys SLM2008 - page 7

    3 Installation 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Chapter 3 Chapter 3: Installation Over view This chapter will explain how to connect network devices to the Switch. The following diagram shows a t ypical network configuration. Internet Cable/DSL Modem Router Wireless A ccess Poin t Po wered b y Switch Deskt ...

  • Linksys SLM2008 - page 8

    4 Installation 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Chapter 3 Placement Options There are t wo ways to physically install the Switch, either hang the Switch on a wall using its wall-mount slots or place it on a desktop . W all-Mount Placement Y ou will need 2 suitable screws to mount the Switch. Suggested Moun ...

  • Linksys SLM2008 - page 9

    Chapter 4 Advanced Configura tion 5 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Chapter 4: A dvanc ed C onfigur a tion Open your web browser and enter http://192.168.1.254 into the addr ess field. P ress the Enter key and the Password screen will appear . Address Bar NO TE: The default IP addr ess is 192.168.1.254 . ...

  • Linksys SLM2008 - page 10

    Chapter 4 Advanced Configura tion 6 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Be sure to click Save Settings and reboot the Switch by going to Admin > Reboot . P ort > Port S ettings Y ou can manually configure the speed, duplex, and flow contr ol settings used on specific por ts, or use autonegotiation to al ...

  • Linksys SLM2008 - page 11

    Chapter 4 Advanced Configura tion 7 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Port > LACP Settings Port Displays the port number . Enable LACP Enables LACP . Admin Ke y A channel will only be formed between ports having the same admin key. This only applies to por ts located on the same switch. The default setti ...

  • Linksys SLM2008 - page 12

    Chapter 4 Advanced Configura tion 8 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Enable Tx Forc e Untag When this option is enabled, all egress frames from this port become untagged. The default value is D isable . When this function is disabled, only frames with the VLAN ID equal to the PVID will become untagged, oth ...

  • Linksys SLM2008 - page 13

    Chapter 4 Advanced Configura tion 9 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er RADIUS UDP Port Enter the UDP Port of the ser ver . The UDP por t is used to verify the RADIUS ser ver authentication. The default value is 1812 . Key String Enter the secret key string as defined on the RADIUS server . The secret key str ...

  • Linksys SLM2008 - page 14

    Chapter 4 Advanced Configura tion 10 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Management IP address 1 Enter the IP address of a device that you wish t o allow manage the Switch. Management IP address 2 Enter the IP address of a second device that y ou wish to allow manage the Swit ch. Management IP address 3 Enter ...

  • Linksys SLM2008 - page 15

    Chapter 4 Advanced Configura tion 11 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er QoS Mode Set the Q oS Mode to Q oS Disabled, 802.1p, P ort Based, or DSCP . 802.1p Enabled? 802.1p QoS Y es Y es No No Port QoS No No DSCP QoS Y es Y es T agged? DSCP Found? Packet DSCP Enabled? QoS Mode Priority Diagram 802.1p 802.1p Q ...

  • Linksys SLM2008 - page 16

    Chapter 4 Advanced Configura tion 12 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Sy stem Priority Bridge prior ity is used in selecting the root device , root port, and designated por t. The device with the highest prior ity becomes the ST A root device. Howev er , if all devices have the same priority, the device wi ...

  • Linksys SLM2008 - page 17

    Chapter 4 Advanced Configura tion 13 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Rx Fr ames Displays the number of frames received on the port since the device was last refreshed. Tx Errors Displays the number of transmitted packets with err ors that have occurred on the port since the device was last refreshed . Rx ...

  • Linksys SLM2008 - page 18

    Chapter 4 Advanced Configura tion 14 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Ping Paramet ers T arget IP A ddress Enter the IP Addr ess of the device y ou want to ping . Coun t Set the maximum count to the target IP Address for each attempt. Time Out Set the time out (in sec onds) in terval if the device does not ...

  • Linksys SLM2008 - page 19

    Chapter 4 Advanced Configura tion 15 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Admin > Firm w are Upgrade Allows you to upgrade the firmware using your Web browser . Admin > FIrmware Upgr ade Firm war e Upgrade T o do so, per form the following steps: Click the Brow se button. Locate the appr opriate file and ...

  • Linksys SLM2008 - page 20

    16 Glossar y 5-Port and 8-Port 10/100/1000 Gigabit Smart Switch with PD and AC P ow er Appendix A Appendix A: Glossar y This glossar y contains some basic networking terms you may come across when using this pr oduct. WEB: F or additional terms, please visit the glossary at w w w .linksys.com/glossary Ac cess Mode Specifies the method by which user ...

  • Linksys SLM2008 - page 21

    17 Glossar y 5-Port and 8-Port 10/100/1000 Gigabit Smart Switch with PD and AC P ow er Appendix A CoS (Class of Ser vice) The 802.1p priority scheme. CoS provides a method for tagging packets with priorit y information. A C oS v alue between 0-7 is added to the Layer II header of packets, where zer o is the low est priority and seven is the highest ...

  • Linksys SLM2008 - page 22

    18 Glossar y 5-Port and 8-Port 10/100/1000 Gigabit Smart Switch with PD and AC P ow er Appendix A MAC (Media Ac cess Control) Address The unique address that a manufac turer assigns to each net working device. Mask A filter that includes or excludes cer tain values, for example parts of an IP address. Mbps (MegaBits P er Second) One million bits pe ...

  • Linksys SLM2008 - page 23

    19 Glossar y 5-Port and 8-Port 10/100/1000 Gigabit Smart Switch with PD and AC P ow er Appendix A T CP ( T ransmission Control Protoc ol) A network protocol for transmitting data that requires ack nowledgement from the recipient of da ta sent. T CP/IP ( T ransmission Control Protoc ol/Internet Protoc ol) A set of instruc tions PCs use to communicat ...

  • Linksys SLM2008 - page 24

    20 Specific ations 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Appendix B Appendix B: Specifications SLM2005 Specifications Ports 5 RJ-45 Connectors for 10BASE-T/100BASE-TX/ 1000BASE-T Auto MDI/MDI-X Autonegotiate/Manual Setting Buttons Reset Cabling Type UTP CAT 5 or Better for 10BASE-T/100BASE-TX, UTP CAT 5e or Be ...

  • Linksys SLM2008 - page 25

    21 Specific ations 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Appendix B SLM2008 Specifications Ports 8 RJ-45 Connectors for 10BASE-T/100BASE-TX/ 1000BASE-T Auto MDI/MDI-X Autonegotiate/Manual setting Buttons Reset Cabling Type UTP CAT 5 or Better for 10BASE-T/100BASE-TX, UTP CAT 5e or Better for 1000BASE-T LEDs Li ...

  • Linksys SLM2008 - page 26

    22 Warranty and R egulatory Information 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Appendix C Appendix C: W arranty and Regulat or y Informa tion Limited W arranty Linksys w arrants to Y ou that, f or a period of fiv e y ears (the “ Warranty Period”), your Linksys Pr oduct will be substantially fr ee of defects ...

  • Linksys SLM2008 - page 27

    23 Warranty and R egulatory Information 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Appendix C FCC Sta tement This produc t has been tested and complies with the specifications for a Class B digital device, pursuant to Part 15 of the FC C Rules. These limits are designed to provide reasonable protection against harmf ...

  • Linksys SLM2008 - page 28

    24 Warranty and R egulatory Information 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Appendix C User Inf ormation f or Consumer Products Cov ered b y EU Directive 2002/96/EC on W aste Electric and Elec tronic Equipment ( WEEE) This document contains impor tant information for users with regards to the proper disposal ...

  • Linksys SLM2008 - page 29

    25 Warranty and R egulatory Information 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Appendix C Eesti (Estonian) - Keskkonnaalane informatsioon Euroopa Liidus asuv atele klientidele Euroopa Liidu direktiivi 2002/96/EÜ nõuete kohaselt on seadmeid, millel on tootel või pakendil k äesolev sümbol , keelatud kõr vald ...

  • Linksys SLM2008 - page 30

    26 Warranty and R egulatory Information 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Appendix C Lietuvškai (Lithuanian) - Aplink osaugos inf ormacija, skir ta Europos Sąjungos vartotojams Europos dir ektyva 2002/96/EC numato , kad įrangos, kuri ir kurios pakuotė yra pažymėta šiuo simboliu (įv eskite simbolį), ...

  • Linksys SLM2008 - page 31

    27 Warranty and R egulatory Information 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Appendix C Português (P ortuguese) - Informação ambiental para clientes da União Eur opeia A Directiva Europeia 2002/96/CE exige que o equipamento que exibe este símbolo no produto e/ou na sua embalagem não seja eliminado junto ...

  • Linksys SLM2008 - page 32

    28 Contac t Informa tion 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC P ow er Appendix D Appendix D: C ontact Informa tion Linksys C ontact Information W ebsite http://www .linksys.com E-Mail suppor t@linksys.c om FTP Site ftp.linksys .com Advice Line 800-546-5797 (LINKSYS) Support 800-326-7114 RMA (Return Merchandise Authori ...

Manufacturer Linksys Category Switch

Documents that we receive from a manufacturer of a Linksys SLM2008 can be divided into several groups. They are, among others:
- Linksys technical drawings
- SLM2008 manuals
- Linksys product data sheets
- information booklets
- or energy labels Linksys SLM2008
All of them are important, but the most important information from the point of view of use of the device are in the user manual Linksys SLM2008.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Linksys SLM2008, service manual, brief instructions and user manuals Linksys SLM2008. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Linksys SLM2008.

Similar manuals

A complete manual for the device Linksys SLM2008, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Linksys SLM2008 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Linksys SLM2008.

A complete Linksys manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Linksys SLM2008 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Linksys SLM2008, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Linksys SLM2008, that we can find in the current document
3. Tips how to use the basic functions of the device Linksys SLM2008 - which should help us in our first steps of using Linksys SLM2008
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Linksys SLM2008
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Linksys SLM2008 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Linksys SLM2008?

Use the form below

If you did not solve your problem by using a manual Linksys SLM2008, ask a question using the form below. If a user had a similar problem with Linksys SLM2008 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)