  • York K3EU180A50 - page 1

    GENERAL This completely assembled blower unit is manufactured under ISO 9002 Quality System Certification and includes a well- insulated cabinet, a DX cooling coil with copper tubes and alu- minum fins, an expansion valve, a distributor , throwaway fil- ters, a centrifugal blower , a blower motor , a blower motor contactor , an adjustable belt driv ...

  • York K3EU180A50 - page 2

    LIMIT ATIONS These units must be installed in accordance with applicable na - tional, local and municipal safety codes. If components are to be added to a unit to meet local codes, they are to be installed at the dealer's and/or the customer's ex - pense. Refer to T able 2 for Unit Application Data. LOCATION This blower unit is not design ...

  • York K3EU180A50 - page 3

    VERTICAL/HORIZONT AL INST ALLATION The unit is shipped for vertical installation with a vertical air dis - charge as shown in Figure 1, but may be converted to other ar - rangements per the following instructions. 1. Remove the panels from the blower section. 2. Remove the four Phillips machine bolts that hold the coil and blower sections together ...

  • York K3EU180A50 - page 4

    NOTE: T o minimize the possibility of system failure due to dirt and moisture, a filter-drier must be installed in each liq - uid line as close to the evaporator as possible. Filter- driers are not supplied with the evaporator blowers. They are supplied with the matching condensing sec - tions. The temperature required to make or break a brazed joi ...

  • York K3EU180A50 - page 5

    4. All pulleys are factory aligned. 5. All supply air motor pulleys are factory set at two “turns open.” After the supply air blower motor is operating, adjust the resis - tances in both the supply and the return duct systems to bal - ance the air distribution throughout the conditioned space. The job specifications may require that this balanc ...

  • York K3EU180A50 - page 6

    6 Unitary Products Group 035-12124-000 Rev . A (0501)I SUPPL Y AIR BLOWER PERFORMANCE 1 - (CFM) BLOWER SPEED RPM AIRFLOW ESP 2 (IWG) OUTPUT (BHP) INPUT (kW) ESP 2 (IWG) OUTPUT (BHP) INPUT (KW) ESP 2 (IWG) OUTPUT (BHP) INPUT (kW) ESP 2 (IWG) OUTPUT (BHP) INPUT (kW) ESP 2 (IWG) OUTPUT (BHP) INPUT (kW 4800 CFM 5400 CFM 6000 CFM 6600 CFM 7200 CFM 600 0 ...

  • York K3EU180A50 - page 7

    Unitary Products Group 7 035-12124-000 Rev . A (0501) FIG 7 - UNIT DIMENSIONS AND CLEARANCES UNIT ACCESSORIES •ELECTRIC HEA TER Add 15" (381mm) to Unit Height when using 10, 16, 26 or 36kW Heater •SUPPL Y AIR PLENUM Add 27" (686mm) to Unit Height when used •BASE Add 24" (610mm) to Unit Height when used MINIMUM CLEARANCES (in./m ...

  • York K3EU180A50 - page 8

    MOTOR SPECIFICATIONS •1450 RPM •380/415-3-50 •Solid base •56 Frame •Inherently protected •Permanently lubricated ball bearings MAINTENANCE FILTERS — The filters must be replaced as often as necessary to assure good air flow and filtering action. EV APORATOR COIL — Do not allow dirt to accumulate on the evaporator coil or other parts ...

Manufacturer York Category Blower

Documents that we receive from a manufacturer of a York K3EU180A50 can be divided into several groups. They are, among others:
- York technical drawings
- K3EU180A50 manuals
- York product data sheets
- information booklets
- or energy labels York K3EU180A50
All of them are important, but the most important information from the point of view of use of the device are in the user manual York K3EU180A50.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals York K3EU180A50, service manual, brief instructions and user manuals York K3EU180A50. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product York K3EU180A50.

Similar manuals

A complete manual for the device York K3EU180A50, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use York K3EU180A50 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of York K3EU180A50.

A complete York manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual York K3EU180A50 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the York K3EU180A50, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the York K3EU180A50, that we can find in the current document
3. Tips how to use the basic functions of the device York K3EU180A50 - which should help us in our first steps of using York K3EU180A50
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with York K3EU180A50
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of York K3EU180A50 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning York K3EU180A50?

Use the form below

If you did not solve your problem by using a manual York K3EU180A50, ask a question using the form below. If a user had a similar problem with York K3EU180A50 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)