    Operation/Reference Guide Touc h Panels Modero ® CV5 G4 Touch Panel NXD-CV5 5” Modero Widescreen Vide o Touch Panels Last Rev ised: 10/1/ 2008 ...

  • AMX NXD-CV5 - page 2

    AMX Limited Warr anty and Disclaimer AMX warrant s it s pro ducts to be free of defect s in materia l and wor kmanshi p under norm al use for three (3) y ears from the date of purc hase from AMX, with the follo wing ex cepti ons: • Electrol umine scent and LCD C ontro l Panels a re wa rranted f or three (3) years, excep t for the disp lay and t o ...

  • AMX NXD-CV5 - page 3

    Table of Contents i 5" Modero Widescreen T ouch Panel Table of Contents Introduc tion ... .......... ............ .......... ......... ....... .......... ............ .......... ............ ......... 1 CV5 Spe cifications ........................ .................... .............................. .................... ...... 2 CV5 Panels - Co ...

  • AMX NXD-CV5 - page 4

    ii 5" Modero Widescreen Touch P anel Table of Contents Step 4: Use the USB to Conf igure a Virtual Master (using NetLinx St udio) .............. ..... 38 Step 5: Co nfirm and View the current AMX USB d evice connecti ons ..... ......... ........... .. 40 Configuring a Wired Ethern et Conn ection ....................................... ........ ...

  • AMX NXD-CV5 - page 5

    Table of Contents iii 5" Modero Widescreen T ouch Panel Sensor Set up .... ........... ............... ........... ............ .............. ............ ........... ......... ............ .. 7 8 Making t he most of t he Automated Br ightness Cont rol feature (DIM Mode) ....... ........ 80 Other Se ttings ........... ................... .... ...

  • AMX NXD-CV5 - page 6

    iv 5" Modero Widescreen Touch P anel Table of Contents Input mask cha racter types ........ ............ ........... ......... ............ ........... ............... ........... 148 Input mask rang es ..... .............. ............ ........... ............... ........... ............ .............. ......... 149 Input mask n ext fiel d ch ...

  • AMX NXD-CV5 - page 7

    Introduc tion 1 5" Modero Widescreen To uch Panel Introduction The NXD-CV5 5" Modero Widescreen Co lo r V ideo T ouch Panels (FIG. 1) are the industry’ s first widescreen mini-touch panels and are av ailable only through AMX. This is the first 5 " diagonal W idescreen Color Active v id eo-capable touch panel in the control and auto ...

  • AMX NXD-CV5 - page 8

    Introduc tion 2 5" Modero Widescreen Touch Panel  CV5 panels feature progr ammable firmware that can be upgraded via either the Ethernet port or the mi ni-US B port. CV5 Specifications The following table outlines the sp e cifications for the 5" W idescreen Modero panel. FIG. 2 NXD-CV5 (front view showing default Trim Ring) Specificati ...

  • AMX NXD-CV5 - page 9

    Introduc tion 3 5" Modero Widescreen To uch Panel Specifications for 5" Wides creen Video Touch Panel (Cont.) Viewing Angles: • 90° total viewing angle: - Horizontal: + 45° (left and right from center) IR Reception Angle: • Horizontal: + 25° (left and right from center) •V e r t i c a l : + 15° (up and down from center) Support ...

  • AMX NXD-CV5 - page 10

    Introduc tion 4 5" Modero Widescreen Touch Panel Specifications for 5" Wides creen Video Touch Panel (Cont.) Side Pane l Component s (Cont. ): Mini-USB connector : • 5-pin Mini-USB connector used for programming, firmware update, and touch panel file transfer between the PC and the target panel. Note : When connecting the panel to PC us ...

  • AMX NXD-CV5 - page 11

    Introduc tion 5 5" Modero Widescreen To uch Panel CV5 Panels - C o nnector Layout FIG. 3 shows th e layout of the connecto rs (locate d on t he left side panel of the N XD-CV 5 panel ). Specifications for 5" Wides creen Video Touch Panel (Cont.) Other A MX Eq uipmen t (Cont. ): • NXA -BEZ-5NB, Bezel Kit without buttons for Modero 5” W ...

  • AMX NXD-CV5 - page 12

    Introduc tion 6 5" Modero Widescreen Touch Panel ...

  • AMX NXD-CV5 - page 13

    CV5 Touch Panel Accessories 7 5" Modero Widescreen To uch Panel CV5 Touch Panel Accessories The following section outlines and describes both the included accessories and other AMX equipment a vaila ble for th ese touch panels. NXA-AVB/ETHERNET Breakout Box (FG2254-10) The NXA-A VB/ETHERNET Breakout Box (FIG. 4) is sold as a separate accessory ...

  • AMX NXD-CV5 - page 14

    CV5 Touch Panel Ac cessories 8 5" Modero Widescreen Touch Panel Installing the NXA-AVB/ETHERNET A 12 VDC-compliant power supply can indirectly provide po wer to a Modero panel by routing po wer through the NXA-A VB/ETHERNET Breakout Box. FIG. 5 sh ows a sample wiring configuration u s ing both an indirect or direct power connection for a video ...

  • AMX NXD-CV5 - page 15

    CV5 Touch Panel Accessories 9 5" Modero Widescreen To uch Panel Use a standard CA T5 Ethernet cable to provide both communication and 10/100 network connectivity between the panel, NXA-A VB/ETHERNET , NetLinx Master, and the network. Wiring the NXA-AVB/ETHER N ET conne ctors and cables The inputs and outputs on the breakout box are separated i ...

  • AMX NXD-CV5 - page 16

    CV5 Touch Panel Ac cessories 10 5" Modero Widescreen Touch Panel Wiri ng the N XA-AVB/ETHER N ET f or Unbalanced Audio Most domestic audio equipment has unbalanced audio inputs and outputs. This means that the audio outpu t (left , right, o r mono ) appear s on a si ngle wi re, an d is refer ence d to "0 V" or "Groun d". T ...

  • AMX NXD-CV5 - page 17

    CV5 Touch Panel Accessories 11 5" Modero Widescreen To uch Panel The 3 wires used in a typical XLR lead are often referred to as Ground, Liv e (Hot) and Return (Cold). "Liv e" and "Return" carry the "in-phase" an d "out-of- phase" versions of the audio respectiv ely . Th e pins of the XLR plug/socket are ...

  • AMX NXD-CV5 - page 18

    CV5 Touch Panel Ac cessories 12 5" Modero Widescreen Touch Panel ...

  • AMX NXD-CV5 - page 19

    Installation 13 5" Modero Widescreen To uch Panel Installation This NXD panels can be installed into e ither a pre-wall surf ace (using a CB-TP5 rough-in/wallbox) or a solid surface (using either solid surface or drywall scre ws). Unpacking the Panel 1. Inspect and confirm the contents of the shipment box to verify you hav e all specified part ...

  • AMX NXD-CV5 - page 20

    Installation 14 5" Modero Widescreen Touch Panel 8. Firmly press down around the No-Button Tr im Ring until all of the latch es are securely inserted into their openings on the Faceplate, and the No-Button T rim Ring is securely fastened. V erify the No-Button T rim Ring is firmly inserted onto the Faceplate and that there are no gaps between ...

  • AMX NXD-CV5 - page 21

    Installation 15 5" Modero Widescreen To uch Panel Installing the Bu tton Trim Ring The outer No-Button T r im Ring is s e cured to the F aceplate with plastic latches. In order to re-install the Button T rim Ring back onto an NXD panel which has had the defau lt Bu tton T rim Ring features removed ; you must f irst remov e the No- Button T rim ...

  • AMX NXD-CV5 - page 22

    Installation 16 5" Modero Widescreen Touch Panel Installing the Opti onal NXA-BEZ Col ored Trim Ring Kits The Bezel T rim Ring Kits allow a user to change to both the color of the faceplate and determine whether the panel will or will not use colored pushb uttons. Each grouping has been configured so that the accompanying F aceplate, T rim Rin ...

  • AMX NXD-CV5 - page 23

    Installation 17 5" Modero Widescreen To uch Panel FIG. 14 provides an e x ample of the general contents for each of the two types of Bezel Kit conf igurati ons (Button and No- Button). These Bezel Kits require some assembly prior to installation onto the panel. Once assem bled, the pre- existing F acep late can be remov ed and upgraded by usin ...

  • AMX NXD-CV5 - page 24

    Installation 18 5" Modero Widescreen Touch Panel 3. Assemble the Kit components:  T o assemble the Beze l Kit with Buttons (FIG. 15):  From along the internal surface of the colored Faceplate, install the six colored buttons by f ir mly inserting them into the b u tton openings until the Button latch secures the b utton in place (FIG. 15 ...

  • AMX NXD-CV5 - page 25

    Installation 19 5" Modero Widescreen To uch Panel Pre-Wall Installation of the Rough-In Box W all Mount panels (NXDs) are contained within an outer housing (back box). This back box is not removed when installing the NXD into a CB-TP5 Rough-In Box. The back box is only remov ed to gain access for the replacement of the internal components. The ...

  • AMX NXD-CV5 - page 26

    Installation 20 5" Modero Widescreen Touch Panel 4. Thre ad the incoming p ower , R J-45 audio /vide o, Ethern et, and USB wiring through th e knocko uts ( use of the left wiring knockouts are recommended with this installation ). Leav e en ough slack in the wiring to accommodate any re-positioning of the panel. 5. Install the drywall/sheetroc ...

  • AMX NXD-CV5 - page 27

    Installation 21 5" Modero Widescreen To uch Panel 3. Conne ct all data and p ower wir ing connecto rs to their corr esponding lo c atio ns along the sid e of th e (un-powered) NXD touch panel.  V er ify that the terminal end of the power cable is n ot connected to a power source before plug ging in the 2 -pin po wer conne ctor .  The USB ...

  • AMX NXD-CV5 - page 28

    Installation 22 5" Modero Widescreen Touch Panel 10. Reconnect the terminal po wer connector on the 12 VDC-compliant power supply and apply po wer . Install ing the N XD into drywall using Expansion Cli ps Expansion clips a re mounted thro ugh the three ov al holes lo cated along the rim of th e NXD-CV5. As the scre w is tightened, the clip be ...

  • AMX NXD-CV5 - page 29

    Installation 23 5" Modero Widescreen To uch Panel 6. T est the incoming wiring by attaching the panel co nnections to their terminal locations and applying power . V erif y the panel is receiv in g po we r and functioning properly to preven t re petition of the installation. 7. Disconnect the terminal end of the po w er cable from the connecte ...

  • AMX NXD-CV5 - page 30

    Installation 24 5" Modero Widescreen Touch Panel 8. Install the three sets of dry wall scre ws an d expansion clips into the three oval notch locations along both sides of the main unit ( B in FIG. 20). 9. Carefully insert the main unit (with expansion clips) into the cutout until the Mounting T a bs on the NXD unit lie flush against the wall. ...

  • AMX NXD-CV5 - page 31

    Installation 25 5" Modero Widescreen To uch Panel Install ing the N XD into a Flat Surfac e using # 4 screws Mounting screws (#4, not in cluded) are secured through circu lar holes located at the left and right sides of the NXD- CV5. The most important thing to remember when mo unt ing the NXD is that the outer frame (Mounting T abs) must be i ...

  • AMX NXD-CV5 - page 32

    Installation 26 5" Modero Widescreen Touch Panel 5. Connect all data and power wiring connectors to their corresponding locations along the left side of the (un-po were d) NXD to uch pane l.  V er ify that the terminal end of the power cable is not connected to a power source before plug ging in the 2 -pin po wer conne ctor .  The USB co ...

  • AMX NXD-CV5 - page 33

    Installation 27 5" Modero Widescreen To uch Panel 10. Place the Faceplate/T rim Ring assembly ( A in FIG. 22) ba ck onto the main NXD unit ( B in FIG. 22). Mak e sur e to align the Micr ophone, Light, and PIR Motion sensor locations to their r espective openings on the fr ont bezel/faceplate. 11. Reconn ect the ter m inal RJ-45, Ether net, U S ...

  • AMX NXD-CV5 - page 34

    Installation 28 5" Modero Widescreen Touch Panel Wiring Guidelines for the CV5 Panels The CV5 panel uses a 12 VDC -comp liant p ower suppl y to provid e power to the pane l via the 2-pin 3.5 mm mini-Phoenix PWR connector . Use the po wer requirem ents information (page 2) to determine the power draw . The in coming PWR and GND wire s from the ...

  • AMX NXD-CV5 - page 35

    Installation 29 5" Modero Widescreen To uch Panel Audio/Video Port: Co nnections and Wiring The f ollo wing tab le sho w s the signal a nd p inout/ pairing inf ormation u sed on t h e RJ -45 Aud io and V ide o connections. Ethernet/RJ-45 Port: Connections and Wiring FIG. 24 describes the blink activ ity for the Ethernet 10/100 Base-T RJ-45 con ...

  • AMX NXD-CV5 - page 36

    Installation 30 5" Modero Widescreen Touch Panel FIG. 25 diagrams the RJ-45 pinouts and signals for the Ethernet RJ-45 connector an d cable. USB Port: Connecting and Using Input Devices The CV5 panel can hav e up to two USB-capable input devices connected for use on its dif f erent firmware an d TPD4 pan el pa ges. The se in put devices can co ...

  • AMX NXD-CV5 - page 37

    Panel Calibration 31 5" Modero Widescreen To uch Panel Panel Calibration This section outlines the steps for calibrating the touch panel. It is r ecommended that you calibrate the panel befor e its initial use and after completing a f irmwar e download. Modero panels are factory setup with specific d em o touch panel pages. The f irst splash s ...

  • AMX NXD-CV5 - page 38

    Panel Calibration 32 5" Modero Widescreen Touch Panel Testi ng your Calibr ation 1. Press and hold do wn the on-screen Calibration button f or 6 seconds to enter the Calibration T est page (F IG. 2 9). 2. Press anywhere on th is page to conf irm the on-screen crosshairs match your touch poin ts. 3. If the crosshairs do not appear directly belo ...

  • AMX NXD-CV5 - page 39

    Configuring Communication 33 5" Modero Widescreen To uch Panel Configuring Communication Communication between the Modero panel and the Master is done using either USB or ETH ERN ET ( DHCP or Static IP ). Ethernet communication can only be achieved via a direct Ethernet connection ( the NXA-WC802.11B/CF wir eless interface car d is not availab ...

  • AMX NXD-CV5 - page 40

    Configuring Communication 34 5" Modero Widescreen Touch Panel 8. Obtain the System Number and Master IP Address from NetLinx Studio. This in f ormation must be specific for the system used with the configured Modero panel. 9. Press t he gr ey Front Set up Access b utton for 3 s econds to open the Setup page. 10. Press the Protected Setup butto ...

  • AMX NXD-CV5 - page 41

    Configuring Communication 35 5" Modero Widescreen To uch Panel Configuring and Using USB with a Virtual Master NetLinx Studio can be setup to run a V irtual Master where the PC acts as the Master by supplying its o wn IP Address for communication to th e panel. The PC is f irst equipped with the USB dri ver , the panel is then configured for U ...

  • AMX NXD-CV5 - page 42

    Configuring Communication 36 5" Modero Widescreen Touch Panel 6. Press the Back b utton on the touch panel to return to the Protected Setup page. 7. Press the on-screen Reboot button to b oth sa ve any changes and r estart t he panel. Remember that the panel’ s connection type must be set to USB prior to r ebooting the panel and prior to ins ...

  • AMX NXD-CV5 - page 43

    Configuring Communication 37 5" Modero Widescreen To uch Panel  The d riv er does no t contain a Micro soft ® digita l signature and W indo ws ® then informs you of such. 9. Click Ye s when told that a digital signature was not found. This action accepts the installation o f the ne w AMX USB d ri ver . The panel is now conf ig ured t o co ...

  • AMX NXD-CV5 - page 44

    Configuring Communication 38 5" Modero Widescreen Touch Panel 5. Click the Properties button to v iew further information about the installed USB dri ver . T o r emove the USB driver asso cia tion fr om a pre viously co nnected tou ch panel, you must na vigat e back to the De vice Man ager , right-click on the panel’ s USB driv er (example A ...

  • AMX NXD-CV5 - page 45

    Configuring Communication 39 5" Modero Widescreen To uch Panel 6. Click on the Vir t u a l M a s t e r radio bo x ( fr om the T ra nsport Connection Option section ) to indicate you are wanting to conf igure the PC to communicate directly with a panel. Everything else such as the Authentication is greyed-out because you are not going through t ...

  • AMX NXD-CV5 - page 46

    Configuring Communication 40 5" Modero Widescreen Touch Panel Step 5: Co nfirm and Vie w the cur rent AMX US B device conn ections Use the CC-USB T ype-A to Mini-B 5-wire programming cab le ( FG10 -5965 ) to provide communication between the mini-USB Program port on the touch panel and the PC. This method of communication is used to transfer f ...

  • AMX NXD-CV5 - page 47

    Configuring Communication 41 5" Modero Widescreen To uch Panel Step 1: Configure the Pa nel’s W ired IP Settings This panel has only one method of communicating to a target Master o ver the Internet: W ired (direct Ethernet connection) ( wireless commu nication is not available on the CV5 ). Y ou can only c onfigur e the connection parameter ...

  • AMX NXD-CV5 - page 48

    Configuring Communication 42 5" Modero Widescreen Touch Panel 6. Repeat the same process for the Subnet Mask and Gateway fie ld s. 7. Press the optional Host Name field to open the Keyboard and enter the Host Name information. 8. Press Done after you are f in ished assigning the alpha-numeric string of the host name. 9. Press the Primary DNS f ...

  • AMX NXD-CV5 - page 49

    Configuring Communication 43 5" Modero Widescreen To uch Panel 4. V erify the green Ethernet LED (from the rear Eth ernet port on the Master) is illuminated (indicating a proper connection). 5. V erify the yellow LED (from the rear Ethernet port on the Master) is blinking (indicating communication). 6. After the panel po wers-up, press and hol ...

  • AMX NXD-CV5 - page 50

    Configuring Communication 44 5" Modero Widescreen Touch Panel 8. From within this dialog enter th e System number ( default is 1 ) and note the IP Address of the target PC being used as the V irtual Master . This IP Address can also be obtained by following these procedures:  On your PC, click Start > Run to open the Run dialog.  Ente ...

  • AMX NXD-CV5 - page 51

    Configuring Communication 45 5" Modero Widescreen To uch Panel 14. Press the blue Ty p e fi e ld ( from the Master Connection section ) until the choice cycles to the word Ethernet . 15. Press the Mode field until th e choice c ycles to the word URL .  By selecting URL , the System Nu mber field becomes read-only (grey) because the panel p ...

  • AMX NXD-CV5 - page 52

    Configuring Communication 46 5" Modero Widescreen Touch Panel Master Conn ection section - Net L inx Maste r Ethernet IP Address - Listen Mode In this mode, you must add the Modero panel IP Address into the URL List of the Ma ster (using NetLinx Studio). This mode sets the Modero panel to "listen" for b roadcasts from the Master (usi ...

  • AMX NXD-CV5 - page 53

    Configuring Communication 47 5" Modero Widescreen To uch Panel Master Conn ection sectio n - NetLinx Maste r Etherne t IP Address - Auto Mod e In this mode, enter the System Number of the NetLinx Master . This mode instructs the Modero to searc h for a Master that uses the same System Numb er (a ssigned within the Master Connection section) an ...

  • AMX NXD-CV5 - page 54

    Configuring Communication 48 5" Modero Widescreen Touch Panel 7. The Network Interface Select field is read-only and displays the method of communication to the web . V erify y ou have s elected the proper interface connection as this f ield does not auto-detect the connection type being used ( see bel ow ) .  Wire d is used w hen a dire ct ...

  • AMX NXD-CV5 - page 55

    Configuring Communication 49 5" Modero Widescreen To uch Panel 16. Press Done when you are fin ish ed entering the v alue. The r emaining fields within the G4 W eb Contr ol S ettings section of this page ar e read-only and can not be altered. 17. Press the Up/Down ar rows o n either side s of the G4 W eb Control Ti m e o u t field to increase ...

  • AMX NXD-CV5 - page 56

    Configuring Communication 50 5" Modero Widescreen Touch Panel 6. Click on the G4 panel name link associa ted with the target panel. A secondary web browser windo w appears on the screen (FIG. 46). 7. Click Ye s from the Security Alert popup window to agree to the installation of the G4 W ebCon trol application on your computer . This applicati ...

  • AMX NXD-CV5 - page 57

    Configuring Communication 51 5" Modero Widescreen To uch Panel 9. If a W ebControl passw ord was setup on the G4 W ebContr ol page, a G 4 Authentic ation Session passw ord dialog bo x appears o n the screen w ithin t he sec ondary bro wser wind ow . 10. Enter the W eb Control session password into the Se ssio n P as sword field (FIG. 46). This ...

  • AMX NXD-CV5 - page 58

    Configuring Communication 52 5" Modero Widescreen Touch Panel ...

  • AMX NXD-CV5 - page 59

    Upgrading Modero Fir mware 53 5" Modero Widescreen To uch Panel Upgrading Mode ro Firmware Before beginni ng th e Upgrade pr ocess:  Setup and config ure your Ne tLinx Maste r . Re fer to the your pa rticular N etLinx Maste r Instr uctio n Manu al for de taile d set up proc edur es.  Calibrate and prepare the co mmunication pages on the ...

  • AMX NXD-CV5 - page 60

    Upgradi ng M odero Firmwar e 54 5" Modero Widescreen Touch Panel 5. Press the Back b utton on the touch panel to return to the Protected Setup page. 6. Press the on-screen Reboot button to b oth sa ve any changes and r estart t he panel. Remember that the panel’ s connection type must be set to USB prior to r ebooting the panel and prior to ...

  • AMX NXD-CV5 - page 61

    Upgrading Modero Fir mware 55 5" Modero Widescreen To uch Panel 7. From within this dialog enter the System number (default is 1 ). 8. Click OK three times to clo se the open dialogs, sa ve your settin gs, and return to the main NetLinx Studio application. 9. Click the OnLine T ree tab in the W orkspace window to vie w the devices on the V irt ...

  • AMX NXD-CV5 - page 62

    Upgradi ng M odero Firmwar e 56 5" Modero Widescreen Touch Panel 5. If the panel firmware being used is n o t current, do wn load the latest Kit file b y first logging in to www .amx.com and t hen na vigate to T ech Center > Firmware Files a nd from within the Moder o sectio n of the we b page loc ate your Mod ero pane l. 6. Click on the de ...

  • AMX NXD-CV5 - page 63

    Upgrading Modero Fir mware 57 5" Modero Widescreen To uch Panel Upgrading the Modero Firmwa re via Ethernet (IP Address) Before beginning with this section, v er ify that your panel is po wered and connected to the NetLinx Master through an Ethernet connection. Step 1: P repare the Maste r for commu nication via an IP 1. Obtain the IP Address ...

  • AMX NXD-CV5 - page 64

    Upgradi ng M odero Firmwar e 58 5" Modero Widescreen Touch Panel 8. Click the New button to open the Ne w TCP/IP Settings dialog where you can enter both a prev io usly obtained DHCP or Static IP Address and an associated description for the connection into their respecti ve fields. 9. Place a checkmark within the Automatically Ping the Master ...

  • AMX NXD-CV5 - page 65

    Upgrading Modero Fir mware 59 5" Modero Widescreen To uch Panel 6. Press the Back b utton to return to the Protected Setup page and press the on-screen Reboot b u tton to restart the panel and sa ve any changes. Step 3: V erify and Upgr ade the panel fir mware via an I P 1. Click the OnLine T ree tab in the W orkspace window to vie w the devic ...

  • AMX NXD-CV5 - page 66

    Upgradi ng M odero Firmwar e 60 5" Modero Widescreen Touch Panel 11. Click Close ( after the panel r eboots ) to return to the main program. 12. Right-click the associated System number and select Refresh System . This causes a refresh of all project systems, establishes a ne w connection to the Master , and populates the System list with devi ...

  • AMX NXD-CV5 - page 67

    Firmwar e Pages a nd Descr iptions 61 5" Modero Widescreen To uch Panel Firmware Pages and Descriptions This section describes each firmware page and their specific functional elements. Setup Navigation Buttons These Setup Navigatio n Buttons (FIG. 54) appear on the left of the panel screen when the Setup page is currently acti ve. Protected S ...

  • AMX NXD-CV5 - page 68

    Firmwar e Pages a nd Descr iptions 62 5" Modero Widescreen Touch Panel Setup Page This page (FIG. 5 5) centers arou nd basic Mo dero panel p roperties s uch as: Co nnection Sta tus of the panel, Display T imeout, Inacti v ity Page Flip T im e, Inactiv ity page f ile , and the P anel Brig htness. The elements of the Setup page are described in ...

  • AMX NXD-CV5 - page 69

    Firmwar e Pages a nd Descr iptions 63 5" Modero Widescreen To uch Panel Informa tion The Infor mat ion b u tton provides a me nu to select either the Pr oject Information P age section on page 64 or th e P anel Information P age sectio n on page 65. Select e ither option to access that page. Setup Page Elements (Cont.) Inactivity Page F lip Ti ...

  • AMX NXD-CV5 - page 70

    Firmwar e Pages a nd Descr iptions 64 5" Modero Widescreen Touch Panel Proj ect Info rmat ion Pag e The Pr oject Info rmati on page displ ays the T PDesign4 (TP D4) project file pro perti es currentl y load ed on the selected Modero panel (FIG. 57). Refer to the TPDes ign4 T ouch P a nel Program instruction manual for more specific information ...

  • AMX NXD-CV5 - page 71

    Firmwar e Pages a nd Descr iptions 65 5" Modero Widescreen To uch Panel Panel Info rmation Pag e The P anel Inf ormatio n page (FI G. 58) cente rs around Modero pane l properti es suc h as : resol ution used, on-boar d memory , firmware, addr ess/channel in formation , and string in formation . The elements of the Panel Information page are de ...

  • AMX NXD-CV5 - page 72

    Firmwar e Pages a nd Descr iptions 66 5" Modero Widescreen Touch Panel Time & Date Setup Page The T im e & Date Setup page (FIG. 59) allo ws you to alter/set the time and date info rmation on the NetLinx Master . If either the T ime/Date is modified on this page ( then updated to the Master by pr essing the Set T ime button ), all devi ...

  • AMX NXD-CV5 - page 73

    Firmwar e Pages a nd Descr iptions 67 5" Modero Widescreen To uch Panel The elements of the T im e & Date Setup page are described in the table below: The onl y way to modify a panel’ s time, withou t altering the Ma ster , is to u se NetLinx Code. Time & Date Setup Page Elements Back: Returns you to the previously active touch panel ...

  • AMX NXD-CV5 - page 74

    Firmwar e Pages a nd Descr iptions 68 5" Modero Widescreen Touch Panel Audio Setti ngs Page The Audio Settings pa ge (FIG. 60) ( acc essed by pressi ng the Audio button on th e Se tup page ) allo ws you to adjust the master v olume parameter s and def ault panel sounds on the panel. The elements of the Audio Settings page are described in the ...

  • AMX NXD-CV5 - page 75

    Firmwar e Pages a nd Descr iptions 69 5" Modero Widescreen To uch Panel Suppor ted sa mplin g rates fo r WAV The following is a listing of supported sampling rates asso c iated for W A V f iles played on a CV5 panel. Some W A V files currently played on Modero's may not work on th e se panels. The supported sampling rates for W A V files ...

  • AMX NXD-CV5 - page 76

    Firmwar e Pages a nd Descr iptions 70 5" Modero Widescreen Touch Panel The elements of the V ideo Setup page are described in the table below: Video Setup Page Elements Back: Saves the changes and returns you to the previously active touch panel page. Conn ecti on Status ic on: This visual display of the connection status a llows the user to h ...

  • AMX NXD-CV5 - page 77

    Firmwar e Pages a nd Descr iptions 71 5" Modero Widescreen To uch Panel Protected Set up Na vigatio n Buttons The Protected Setup Navigation Buttons (FIG. 62) appear on the left of the panel screen when the Protected Setup page is currently activ e. FIG. 6 2 Protected Setup Navigation Butt ons Press to access the System Setti ngs page where yo ...

  • AMX NXD-CV5 - page 78

    Firmwar e Pages a nd Descr iptions 72 5" Modero Widescreen Touch Panel Protected Setup Page The Pr otected Se tup pag e (FIG. 63) centers ar ound t he properti es used by t he panel t o prope rly communicate with the NetLinx Master . Enter the factory default passw ord ( 1988) in to the passw o rd ke yp ad to access this page. The elements of ...

  • AMX NXD-CV5 - page 79

    Firmwar e Pages a nd Descr iptions 73 5" Modero Widescreen To uch Panel Protected Setup Page Elements (Cont.) System Recovery: Allows you to either reset the touch panel to factory default settings and/ or wipe out all existing touch panel pages: • The Reset S ystem Set tings button allows a us er to wipe out all c urrent configuration param ...

  • AMX NXD-CV5 - page 80

    Firmwar e Pages a nd Descr iptions 74 5" Modero Widescreen Touch Panel System Set tings Page The System Settings page (FIG. 66) sets the Secondary DNS Address information with its co r responding IP communication parameters, NetLinx Master communication settings, and reads the device number assig ned t o the Moder o panel . The elements of the ...

  • AMX NXD-CV5 - page 81

    Firmwar e Pages a nd Descr iptions 75 5" Modero Widescreen To uch Panel System Connection Page Elements (Cont. ) IP Setting s: (Cont.) MAC Address Displays a read-only field that is factor y set by AMX for the built - in Ethernet interface. Master Connection: Sets the NetLinx M aster com munication values: Ty p e Sets the NetLinx M aster to co ...

  • AMX NXD-CV5 - page 82

    Firmwar e Pages a nd Descr iptions 76 5" Modero Widescreen Touch Panel Calibratio n Page This page (FIG. 67) allo w s you to calibrate the touch panel using the pre-selected touch dri ver .  Press and hold the grey Front Setup Access bu tton (belo w the Modero LCD) for 6 seconds to access the Calibration page.  Press the cr osshairs to c ...

  • AMX NXD-CV5 - page 83

    Firmwar e Pages a nd Descr iptions 77 5" Modero Widescreen To uch Panel G4 Web Control Pa ge The G4 W eb Control page (FIG. 68) centers aro und enabling and disabling both the display and control of your panel (via the web). An external PC r unning a VNC client ( installed durin g the initial communication to the G4 panel ) mak es this pos sib ...

  • AMX NXD-CV5 - page 84

    Firmwar e Pages a nd Descr iptions 78 5" Modero Widescreen Touch Panel Refer to the Using G4 W eb Contr ol to Interact with a G4 P anel sectio n on page 47 for more de tailed instructions on how to use the G4 W eb Control page with the new web-based NetLinx Security application. Sensor Set up The Sensor Setup page (FIG. 70) allows you to ad ju ...

  • AMX NXD-CV5 - page 85

    Firmwar e Pages a nd Descr iptions 79 5" Modero Widescreen To uch Panel The elements of the Sensor Setup page are described in the table below: A light l evel value between the Minimum and Maximum D IM Mod e values de livers an aver age light level. The D IM mode Min L evel can neve r exceed the DIM Mode Max Level . Sensor Setup Page Elements ...

  • AMX NXD-CV5 - page 86

    Firmwar e Pages a nd Descr iptions 80 5" Modero Widescreen Touch Panel Making t he most of t he Automated Brigh tness Control feature ( DIM Mode) Please follow the steps below to set up Automated Brightness Control: 1. Set the lighting conditions in the room to maximum (turn On all the lights). 2. Set the Maximum Panel Brightness, from the Set ...

  • AMX NXD-CV5 - page 87

    Firmwar e Pages a nd Descr iptions 81 5" Modero Widescreen To uch Panel 7. Set the Minimum Dimmer Brightness ( Dim Mode Min Le vel ) to a comfortable lev el by sitting in front of the panel. Y ou should be able to comfortably see someone sitting behind the panel without being “bl inde d” by th e pa nel. 8. Mo ve around t he panel and b loc ...

  • AMX NXD-CV5 - page 88

    Firmwar e Pages a nd Descr iptions 82 5" Modero Widescreen Touch Panel Image Caching Page The Image Caching page (FIG. 72) configures the allocation of memory for image cachin g. The G4 graphics engine caches images to decrease load tim e of pre viously vie we d images. RAM caching is always enabled, and images (both static and dynamic) are st ...

  • AMX NXD-CV5 - page 89

    Firmwar e Pages a nd Descr iptions 83 5" Modero Widescreen To uch Panel Setting the image cache In the Pr otected Setup page: 1. Press the Cache bu tto n in the Pr otected Set up Navigation Bu ttons section. This o pens the Image Cache page . 2. Set the cache expiration in the field Flash/RAM Cache Exp ir es . Th e Up and Down arrows in cr eme ...

  • AMX NXD-CV5 - page 90

    Firmwar e Pages a nd Descr iptions 84 5" Modero Widescreen Touch Panel Clearing the image cache In the Pr otected Setup page: 1. Press the Cache bu tto n in the Pr otected Set up Navigation Bu ttons section. This o pens the Image Cache page . 2. Press Clear Cache . This clears all image cache currently stored on the panel (both Flash and RAM). ...

  • AMX NXD-CV5 - page 91

    Firmwar e Pages a nd Descr iptions 85 5" Modero Widescreen To uch Panel Password Settings P age Back: Saves all changes and returns to the previous page. Conn ecti on Status ic on: The icon in the upper-right corner of eac h Setup page shows online/off line state of the panel to the m aster . • Brig ht red - disconnect ed • Brig ht green - ...

  • AMX NXD-CV5 - page 92

    Firmwar e Pages a nd Descr iptions 86 5" Modero Widescreen Touch Panel Tools The T ools button prov ides a menu to select either the P anel Lo gs P age s ection on page 86, the Pa n e l Statistics P age s e ctio n on page 88, or the Connection Utility P age section on page 90. Se lect any of the options to access that page . Panel Logs Page Th ...

  • AMX NXD-CV5 - page 93

    Firmwar e Pages a nd Descr iptions 87 5" Modero Widescreen To uch Panel Features on this page include: Checking t he Panel Connection L ogs 1. Press the T ools b utton in the Pr otected Setup Navigation Buttons section. This opens the To o l s menu. 2. W ithin the To o l s menu, press the Panel Lo gs button. All connection data is contained in ...

  • AMX NXD-CV5 - page 94

    Firmwar e Pages a nd Descr iptions 88 5" Modero Widescreen Touch Panel Panel Stati stics Page The options on the Panel Statistics page allow you to track the connection status for the panel. Th e Pa n e l Statistics page tracks ICSP me ssages, Blink m essages, and E thernet conne ction s tatistics ( FIG. 76 ) . Features on this page include: F ...

  • AMX NXD-CV5 - page 95

    Firmwar e Pages a nd Descr iptions 89 5" Modero Widescreen To uch Panel Checking t he Panel Statisti cs 1. Press the T ools b utton in the Pr otected Setup Navigation Buttons section. This opens the To o l s menu. 2. W ithin the To o l s menu, press the P anel Statistics button. All connection statistics are contained on this page, e.g ., Rece ...

  • AMX NXD-CV5 - page 96

    Firmwar e Pages a nd Descr iptions 90 5" Modero Widescreen Touch Panel Connecti on Utility Page The options on the Connection Utility page allow you to utilize your panel as a site survey tool. While in this pa ge, move around your wir ele ss net work coverage area a nd se e if ther e are any w eak poi nts withi n the spaces between your W APs ...

  • AMX NXD-CV5 - page 97

    Firmwar e Pages a nd Descr iptions 91 5" Modero Widescreen To uch Panel Using the Connection Utili ty 1. Press the T ools b utton in the Pr otected Setup Navigation Buttons section. This opens the To o l s menu. 2. W ithin the To o l s menu, press the Connection Utility button. This launches the Connection U tility popup . 3. Move the panel wi ...

  • AMX NXD-CV5 - page 98

    Firmwar e Pages a nd Descr iptions 92 5" Modero Widescreen Touch Panel ...

  • AMX NXD-CV5 - page 99

    Progra mming 93 5" Modero Widescreen To uch Panel Programming Y ou can program the touch panel, using the commands in this section, to perform a wide v ariety of opera tions using Send_Comma nds and varia ble te xt comman ds. A device must f irst be defined in the NetLinx pr ogramming language with values f or the Device: Port: System (i n all ...

  • AMX NXD-CV5 - page 100

    Progra mming 94 5" Modero Widescreen Touch Panel Page Commands (C ont.) @DPG Delete a specifi c popup page from specified popup group if it exist s . Syntax: "'@DPG-<popup page name>;<popup group name>'" V ariable: popup page name = 1 - 50 ASCII characters. Name of the popup p age. popup group name = 1 - 50 AS C ...

  • AMX NXD-CV5 - page 101

    Progra mming 95 5" Modero Widescreen To uch Panel Page Commands (C ont.) @PP A Close all popups on a specified page. If the page name is empty , the current page is used. Same as the ’Clear Page’ command in TPDesign4. Syntax: "'@PPA-<page name>'" V ariable: page name = 1 - 50 AS CII characters. Name of the p age t ...

  • AMX NXD-CV5 - page 102

    Progra mming 96 5" Modero Widescreen Touch Panel Page Commands (C ont.) @PPM Set the modality of a specific popup page to Modal or NonModal. A Modal popup page, when active, only allows you to use the buttons and f eatures on that popup page. All ot her buttons on the panel page are i nac tivated. Syntax: "'@PPM-<popup page name&g ...

  • AMX NXD-CV5 - page 103

    Progra mming 97 5" Modero Widescreen To uch Panel Page Commands (C ont.) @PSE Set the show ef fect for the specified popup page to t he named show effect. Syntax: "'@PSE-<popup page name>;<show effect name>'" V ariable: popup page name = 1 - 50 ASCII characters. Name of the p age the popup is displayed On. show ...

  • AMX NXD-CV5 - page 104

    Progra mming 98 5" Modero Widescreen Touch Panel Page Commands (C ont.) PPOF Deactivate a specific popup page on either a specified page or the current page. If the page name is empty , the current page is used (see example 2). If the popup page is part of a group, the whole group is deact ivated. This command work s in the same way as the ’ ...

  • AMX NXD-CV5 - page 105

    Progra mming 99 5" Modero Widescreen To uch Panel Programm ing Numbers The following information provides the programming numbers for colors, fonts, and borders. Colors can be used to set the colors on b uttons, sliders, and pages. The lowest co lor number represents the lightest color- sp ecific d isplay; the highest number represents the dar ...

  • AMX NXD-CV5 - page 106

    Progra mming 100 5" Modero Widescreen Touch Panel RGB Values for a ll 88 Bas ic Colors (C ont.) Inde x No . Name Red Green Blue 36 V ery Light Cyan 0 255 255 37 Light Cyan 0 223 223 38 Cyan 0 191 191 39 Medium Cyan 0 159 159 40 Dark Cy an 0 127 127 41 V ery Dark Cyan 0 95 95 42 V ery Light Aqua 0 128 255 43 Light Aqua 0 1 12 223 44 Aqua 0 96 1 ...

  • AMX NXD-CV5 - page 107

    Progra mming 101 5" Modero Widescreen To uch Panel Font sty les and ID n umbers Font styles c an be used to program the te xt fonts on b uttons, sliders, and pages. The following chart sho ws the de fault fo nt type and t heir respecti ve ID numbers gen erated by TPDesign4. RGB Values for a ll 88 Bas ic Colors (C ont.) Inde x No. Name R ed Gre ...

  • AMX NXD-CV5 - page 108

    Progra mming 102 5" Modero Widescreen Touch Panel Border styles a nd Pro grammi ng num bers Border styles can b e used t o program bo rders on b uttons, sl iders, an d popup pag e s. The TPD esign 4 T o uch Panel D esig n progra m has pr e-se t bord er style s th at are us er sele ctabl e. Y ou cannot use the following number values for progra ...

  • AMX NXD-CV5 - page 109

    Progra mming 103 5" Modero Widescreen To uch Panel TPD4 Border Styles by Name (C ont.) No. Bo rde r styl es No. Bor der style s 43 Diamond 85 85 Menu B ottom Rounded 65 44 Diamond 95 86 Menu B ottom Rounded 75 45 Diamond 105 87 Menu B ottom Rounded 85 46 Diamond 1 15 88 Menu Bottom Rounded 95 47 Diamond 125 89 Menu B ottom Rounded 105 48 Diamo ...

  • AMX NXD-CV5 - page 110

    Progra mming 104 5" Modero Widescreen Touch Panel "^" Bu tton Comm ands These Button Commands are used in NetLinx Studio and are case insensitive. All commands that begin with " ^ " hav e the capability of assigning a variable tex t ad dress range and button state range. A dev ice must first be defined in the NetLinx progra ...

  • AMX NXD-CV5 - page 111

    Progra mming 105 5" Modero Widescreen To uch Panel "^" Button Commands ^ANI Run a button animation (in 1/10 second) . Syntax: "'^ANI-<vt addr range>,<start state>,<end state>,<time>'" V ariable: variable text address range = 1 - 4000. start stat e = Beginning of button state (0= current st ...

  • AMX NXD-CV5 - page 112

    Progra mming 106 5" Modero Widescreen Touch Panel "^" Button Commands ( Cont.) ^BCB Set the bo rder colo r to the specified color . Only if the specified border co lor is not the same as the c urrent color . Note : Color can be assigned by color name ( without spaces), number or R,G ,B value (RRGGBB or RRGGBBAA). Syntax: "' ...

  • AMX NXD-CV5 - page 113

    Progra mming 107 5" Modero Widescreen To uch Panel "^" Button Commands ( Cont.) ^BCT Set the tex t color to the specified color . Only if the specified text color is not the same as the current color . Note : Color can be assigned by color name (without spaces), num ber or R ,G ,B value (RRGGBB or RRGGBBAA). Syntax: "'^BCT- ...

  • AMX NXD-CV5 - page 114

    Progra mming 108 5" Modero Widescreen Touch Panel "^" Button Commands ( Cont.) ^BIM Set the input mask for the specified address. Syntax: "'^BIM-<vt addr range>,<input mask>'" V ariable: variable text address range = 1 - 4000. inpu t ma sk = R efer to t he T ext Area Input Masking section on page 148 f ...

  • AMX NXD-CV5 - page 115

    Progra mming 109 5" Modero Widescreen To uch Panel "^" Button Commands ( Cont.) ^BMC Button copy command. Copy attributes of the source button to all the destination buttons. Note that the source is a s ingle button state. E ach state must be copied as a se parate command. The <c odes> section rep resents what attributes will b ...

  • AMX NXD-CV5 - page 116

    Progra mming 110 5" Modero Widescreen Touch Panel "^" Button Commands ( Cont.) ^BMF Set any/all button pa ramete rs by sending embedded co des and data. Syntax: "'^BMF-<vt addr range>,<button states range>,<data>'" V a riables: variable text address char array = 1 - 4000. button states range = 1 ...

  • AMX NXD-CV5 - page 117

    Progra mming 111 5" Modero Widescreen To uch Panel "^" Button Commands ( Cont.) ^BMF (Con t.) For some o f these comma nds and values, ref er to theRGB V alues f or all 88 Basic Colors table on page 99. ’%CF<on fill c olor>’ = S et Fill Color . ’%CB<on border color>’ = Set Border Color . ’%CT<on text co lor&g ...

  • AMX NXD-CV5 - page 118

    Progra mming 112 5" Modero Widescreen Touch Panel "^" Button Commands ( Cont.) ^BMI Set the button mask image. Mask image is used to crop a borderless butt on to a non-square shape. T h is is typically used with a bit map. Syntax: "'^BMI-<vt addr range>,<button states range>,<mask image>'" V aria ...

  • AMX NXD-CV5 - page 119

    Progra mming 113 5" Modero Widescreen To uch Panel "^" Button Commands ( Cont.) ^BNN Set the T akeNote network name for the specified Addresses. Syntax: "'^BNN-<vt addr range>,<network name>'" V ariable: variable text address range = 1 - 4000. network name = Use a valid IP Address. Example: SEND_COMMAN ...

  • AMX NXD-CV5 - page 120

    Progra mming 114 5" Modero Widescreen Touch Panel "^" Button Commands ( Cont.) ^BOR Set a border to a specific border style associated with a border value for those buttons with a defined address range. Refer to theBorder S tyles and Programm ing Numbers table on page 102 for more information. Syntax: "'^BOR-<vt addr ran ...

  • AMX NXD-CV5 - page 121

    Progra mming 115 5" Modero Widescreen To uch Panel "^" Button Commands ( Cont.) ^BRD Set the border of a button state/ states. Only if the specified border is not the same as the current border . The border names are available through the TPDesi gn4 border-name drop-down list. Syntax: "'^BRD-<vt addr range>,<button ...

  • AMX NXD-CV5 - page 122

    Progra mming 116 5" Modero Widescreen Touch Panel "^" Button Commands ( Cont.) ^BVL Log-On/Log-Off the computer control connection. Syntax: "'^BVL-<vt addr range>,<connection>'" V ariable: variable text address range = 1 - 4000. connection = 0 ( Log-Off connecti on) and 1 (Log-On connection). Example: ...

  • AMX NXD-CV5 - page 123

    Progra mming 117 5" Modero Widescreen To uch Panel "^" Button Commands ( Cont.) ^CPF Clear all page flips from a button. Syntax: "'^CPF-<vt addr range>'" V ariable: variable text address range = 1 - 4000. Example: SEND_COMMAND Panel,"'^CPF-500'" Clears all page f lips from the button. ^DP ...

  • AMX NXD-CV5 - page 124

    Progra mming 118 5" Modero Widescreen Touch Panel "^" Button Commands ( Cont.) ^GDI Change the bargraph drag increment. Syntax: "'^GDI-<vt addr range>,<bargraph drag increment>'" V ariable: variable text address range = 1 - 4000. bargraph drag increment = The de fault drag increm ent is 256. Example: S ...

  • AMX NXD-CV5 - page 125

    Progra mming 119 5" Modero Widescreen To uch Panel "^" Button Commands ( Cont.) ^GRD Change the bargraph ramp-down time in 1/10th of a second. Syntax: "'^GRD-<vt addr range>,<bargraph ramp down time>'" V ariable: variable text address range = 1 - 4000. bargraph ramp down time = In 1/ 10th of a second i ...

  • AMX NXD-CV5 - page 126

    Progra mming 120 5" Modero Widescreen Touch Panel "^" Button Commands ( Cont.) ^ICO Set the icon to a button. Syntax: "'^ICO-<vt addr range>,<button states range>,<icon index>'" V ariable: variable text address range = 1 - 4000. button states range = 1 - 256 for mu lti-state buttons (0 = All stat ...

  • AMX NXD-CV5 - page 127

    Progra mming 121 5" Modero Widescreen To uch Panel "^" Button Commands ( Cont.) ^JST Set text alignment using a numeric keypad layout for those buttons with a defined address range. The alignment of 0 is f ollowed by ',<left>,<to p>'. The l eft and top coordinates are relative to the upper lef t corner of the bu ...

  • AMX NXD-CV5 - page 128

    Progra mming 122 5" Modero Widescreen Touch Panel "^" Button Commands ( Cont.) ^TEC Set the tex t effect color for the specified addresses/states to the specified color . The T ext Effect is spec ified by name and ca n be found in T PD4. Y ou can also assign t he color by name or RGB v alue (RRGGBB o r RRGGBBAA ). Syntax: "&apos ...

  • AMX NXD-CV5 - page 129

    Progra mming 123 5" Modero Widescreen To uch Panel "^" Button Commands ( Cont.) ^UNI Set Unicode text . For the ^UNI command (%UN and ^BMF command), the Unicode text is sent as ASCII-HEX nibbles. Syntax: "'^UNI-<vt addr range>,<button states range>,<unicode text>'" V ariable: variable text addres ...

  • AMX NXD-CV5 - page 130

    Progra mming 124 5" Modero Widescreen Touch Panel Text Effect Names The following is a listing of tex t effects names. This list is as so ciated with the ^TEF c omman d on page 1 22. Text Effects • Glow -S • Hard Drop Shadow 6 • Glow -M • Hard Drop Shadow 7 • Glow -L • Hard Drop Shadow 8 • Glow -X • Soft Drop Shadow 1 with outl ...

  • AMX NXD-CV5 - page 131

    Progra mming 125 5" Modero Widescreen To uch Panel Button Query Commands Button Query commands reply back with a custom ev ent. The re will be one custom e vent for each button/state co m bination. Each query is assigned a unique custom ev en t type. The f ollowing example is f o r debug purposes only: NetLinx Example: CUSTOM_EVENT[device, Add ...

  • AMX NXD-CV5 - page 132

    Progra mming 126 5" Modero Widescreen Touch Panel All custom e vents hav e the followin g 6 fields: These fields are populated dif f erently for each query comma nd. The text length (String Encode) field is not used in an y command. Custom Event Fields Field Des criptio n Uint Flag 0 means text is a st andard st ring, 1 means Unicode encoded s ...

  • AMX NXD-CV5 - page 133

    Progra mming 127 5" Modero Widescreen To uch Panel Button Query Commands (Co nt.) ?BCF Get the current fill color . Syntax: "'?BCF-<vt addr range>,<button states range>'" V ariable: variable text address range = 1 - 4000. button states range = 1 - 256 for m ulti-state buttons (0 = All states, for G eneral button ...

  • AMX NXD-CV5 - page 134

    Progra mming 128 5" Modero Widescreen Touch Panel Button Query Commands (Co nt.) ?BMP Get the current bitmap name. Syntax: "'?BMP-<vt addr range>,<button states range>'" V ariable: variable text address range = 1 - 4000. button states range = 1 - 256 for mu lti-state buttons (0 = All states, for General buttons ...

  • AMX NXD-CV5 - page 135

    Progra mming 129 5" Modero Widescreen To uch Panel Button Query Commands (Co nt.) ?BRD Get the current border name. Syntax: "'?BRD-<vt addr range>,<button states range>'" V ariable: variable text address range = 1 - 4000. button states range = 1 - 256 for m ulti-state buttons (0 = All states, for G eneral button ...

  • AMX NXD-CV5 - page 136

    Progra mming 130 5" Modero Widescreen Touch Panel Button Query Commands (Co nt.) ?FON Get the current font index. Syntax: "'?FON-<vt addr range>,<button states range>'" V ariable: variable text address range = 1 - 4000. button states range = 1 - 256 for mu lti-state buttons (0 = All states, for General buttons 1 ...

  • AMX NXD-CV5 - page 137

    Progra mming 131 5" Modero Widescreen To uch Panel Button Query Commands (Co nt.) ?JSB Get the current bitmap justificat ion. Syntax: "'?JSB-<vt addr range>,<button states range>'" V ariable: variable text address range = 1 - 4000. button states range = 1 - 256 for m ulti-state buttons (0 = All states, for G ene ...

  • AMX NXD-CV5 - page 138

    Progra mming 132 5" Modero Widescreen Touch Panel Button Query Commands (Co nt.) ?JST Get the current text justific ation. Syntax: "'?JST-<vt addr range>,<button states range>'" V ariable: variable text address range = 1 - 4000. button states range = 1 - 256 for mu lti-state buttons (0 = All states, for General ...

  • AMX NXD-CV5 - page 139

    Progra mming 133 5" Modero Widescreen To uch Panel Button Query Commands (Co nt.) ?TEF Get the current text effect name. Syntax: "'?TEF-<vt addr range>,<button states range>'" V ariable: variable text address range = 1 - 4000. button states range = 1 - 256 for m ulti-state buttons (0 = All states, for G eneral b ...

  • AMX NXD-CV5 - page 140

    Progra mming 134 5" Modero Widescreen Touch Panel Panel Runtime Operations Serial Commands are used in the AxcessX T er minal Emulator mode. These commands are case insensiti ve. Panel Runtime Operation Command s ABEEP Output a single beep even if beep is Off. Syntax: "'ABEEP'" Example: SEND COMMAND Panel,"'ABEEP& ...

  • AMX NXD-CV5 - page 141

    Progra mming 135 5" Modero Widescreen To uch Panel Panel Runtime Operation Command s (Cont.) @AKP Pop up the keypad icon and initialize the text string to that specified. Keypad string is set t o null on power up and is s t ored until power is los t. The Prompt T ext is optional. Syntax: "'@AKP-<initial text>;<prompt text> ...

  • AMX NXD-CV5 - page 142

    Progra mming 136 5" Modero Widescreen Touch Panel Panel Runtime Operation Command s (Cont.) @EKP Extend the Keypad. Pops up the keypad icon and initializes the text string to that spe cified. The Prompt T ext is optional. Syntax: "'@EKP-<initial text>;<prompt text>'" V a riables: initial text = 1 - 50 ASCII char ...

  • AMX NXD-CV5 - page 143

    Progra mming 137 5" Modero Widescreen To uch Panel Panel Runtime Operation Command s (Cont.) @SOU Play a sound file. Syntax: "'@SOU-<sound name>'" V a riables: sound name = Name of the sound file. Supported sound file formats are: WAV & MP3. Example: SEND COMMAND Panel,"'@SOU-Music.wav'" Plays ...

  • AMX NXD-CV5 - page 144

    Progra mming 138 5" Modero Widescreen Touch Panel Inpu t Comm ands These Send Commands are case insensitiv e. Input Commands ^CAL Put panel in calibration mode. Syntax: "'^CAL'" Example: SEND COMMAND Panel,"'^CAL'" Puts the p anel in calibration mode. ^KPS Set the keyboard passthru. Syntax: "'^ ...

  • AMX NXD-CV5 - page 145

    Progra mming 139 5" Modero Widescreen To uch Panel Embedded cod es The following is a list of G4 compatible embedded codes: Embedded Codes Decima l numbe r s Hexidecimal v alues Vir t ual keystro ke 8 ($08) Backspace 13 ($0D) Enter 27 ($1B) ESC 128 ($80) CTRL key down 129 ($81) AL T key down 130 ($82) Shift key down 131 ($83) F1 132 ($84) F2 1 ...

  • AMX NXD-CV5 - page 146

    Progra mming 140 5" Modero Widescreen Touch Panel Panel Setup Commands These commands are case insensitiv e. Panel Setup Commands ^MUT Set the panel mute state. Syntax: "'^MUT-<mute state>'" V ariable: mute state= 0 = Mute O ff and 1 = Mute On. Example: SEND_COMMAND Panel,"'^MUT-1''" Sets the ...

  • AMX NXD-CV5 - page 147

    Progra mming 141 5" Modero Widescreen To uch Panel Dynamic Image Commands The following is a listing and descriptions of Dynamic Image Commands. Dynamic Image Commands ^BBR Set the bitmap of a button to use a particular resource. Syntax: "'^BBR-<vt addr range>,<button states range>,<resource name>'" V aria ...

  • AMX NXD-CV5 - page 148

    Progra mming 142 5" Modero Widescreen Touch Panel Dynamic Image Comma nds (Cont.) ^RAF Add new resources. Adds any and all resour ce parameters by sending embedded cod es and data. Syntax: "'^RAF-<resource name>,<data>'" V ariable: resource name = 1 - 50 AS CII characters. data = Refers to the em bedded codes, s ...

  • AMX NXD-CV5 - page 149

    Troubl eshooti ng 143 5" Modero Widescreen To uch Panel Troubleshooting This section describes the solutions to possible hardware/f irmware issues that could arise during the commo n operation of a Mode ro touch pa nel. Troubleshooting Information Symp tom Sol ution My USB drivers has a yellow exclamation point and doesn’t appear to be worki ...

  • AMX NXD-CV5 - page 150

    Troubleshooting 144 5" Modero Widescreen Touch Panel Troubleshooti ng Information ( Cont.) Symp tom Sol ution My Moder o panel isn’t appe aring in my Workspace window . • Verif y t hat the System number is the same on both the NetLinx Workspace window and the S ystem Connection page on the Modero panel. • Verif y you have entered the pro ...

  • AMX NXD-CV5 - page 151

    Troubl eshooti ng 145 5" Modero Widescreen To uch Panel Troubleshooting Information (Cont.) Symp tom Sol ution My on-screen mouse cursor doesn’t appear . • The USB connections are not detected until after the p a rticular USB connection plugged into the corresponding port on the panel and power is cyc led to the panel. Calibrat ion is not ...

  • AMX NXD-CV5 - page 152

    Troubleshooting 146 5" Modero Widescreen Touch Panel Troubleshooti ng Information ( Cont.) Symp tom Sol ution I have more that one Mo dero panel connected to my System Master and only one s hows up. Multiple NetLinx Compati ble devic es (such as Modero panels) can be associated for use with a single M aster . Ea ch Modero panel comes with a de ...

  • AMX NXD-CV5 - page 153

    Appendix A 147 5" Modero Widescreen To uch Panel Appendix A Text Format ting Codes for Barg raphs/Joyst icks T ext formatting codes for bargraphs provide a mechanism to allo w a portion of a bargraphs text to be dynamically provided information about the cu rrent status of the level (multistate and traditional). These codes w ould be e ntered ...

  • AMX NXD-CV5 - page 154

    Appendix A 148 5" Modero Widescreen Touch Panel Text Area Input Mask ing T ext Area Input Masking can be used to limit the allo wed/correct ch aracters that are entered into a text area. For e xam ple, in working with a zip code, a user could limit the entry to a max length of only 5 characters but, with input masking, you could limit them to ...

  • AMX NXD-CV5 - page 155

    Appendix A 149 5" Modero Widescreen To uch Panel Refer to the following Send Commands for more detailed information: Input m ask range s These ranges allow a user to specify the minimum and maximum numer ic v alu e for a field. Only one range is allo wed per field. Using a range implies a num eric entry ONL Y . An example from the above table: ...

  • AMX NXD-CV5 - page 156

    Appendix A 150 5" Modero Widescreen Touch Panel A keyboard entry using norm al text entry is straightforward. H o wever , once an input mask is applied, the behavior of the k eyboard needs to change to accommodate the input mask's requirement. When working with masks, an y literal characters in the mask will be "skipped" by an y ...

  • AMX NXD-CV5 - page 157

    Appendix A 151 5" Modero Widescreen To uch Panel URL Resources A URL ca n be br oken int o several part s. For exam ple: th e URL http://ww w .amx.com/ company-inf o- home.as p . This U RL indicat es that th e pr otocol in use is http (Hyp erT ext Transport Protoc ol) an d that the information resides on a host machine named www .amx.com . The ...

  • AMX NXD-CV5 - page 158

    Appendix A 152 5" Modero Widescreen Touch Panel ...

  • AMX NXD-CV5 - page 159

    Appendix A 153 5" Modero Widescreen To uch Panel ...

  • AMX NXD-CV5 - page 160

    Appendix A 154 5" Modero Widescreen Touch Panel ...

  • AMX NXD-CV5 - page 161

    Appendix A 155 5" Modero Widescreen Touch Panels ...

  • AMX NXD-CV5 - page 162

    10/2008 © 2008 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX. AMX reserves the right to a l ter specific ations without notice at any time. It’s Y ou r Wo rld - Ta ke C on trol ™ 3000 RESEARCH DR IVE, RICHARDSON, TX 75082 USA • 800.222.0193 • 469.624.8000 • 469-624-7153 fax • 800.932.6993 technical s u ...

Manufacturer AMX Category Computer Monitor

Documents that we receive from a manufacturer of a AMX NXD-CV5 can be divided into several groups. They are, among others:
- AMX technical drawings
- NXD-CV5 manuals
- AMX product data sheets
- information booklets
- or energy labels AMX NXD-CV5
All of them are important, but the most important information from the point of view of use of the device are in the user manual AMX NXD-CV5.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals AMX NXD-CV5, service manual, brief instructions and user manuals AMX NXD-CV5. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product AMX NXD-CV5.

Similar manuals

A complete manual for the device AMX NXD-CV5, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use AMX NXD-CV5 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of AMX NXD-CV5.

A complete AMX manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual AMX NXD-CV5 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the AMX NXD-CV5, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the AMX NXD-CV5, that we can find in the current document
3. Tips how to use the basic functions of the device AMX NXD-CV5 - which should help us in our first steps of using AMX NXD-CV5
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with AMX NXD-CV5
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of AMX NXD-CV5 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning AMX NXD-CV5?

Use the form below

If you did not solve your problem by using a manual AMX NXD-CV5, ask a question using the form below. If a user had a similar problem with AMX NXD-CV5 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)