Manual Fluke Thermal Imagers Ti10

24 pages 0.41 mb
Download

Go to site of 24

Summary
  • Fluke Thermal Imagers Ti10 - page 1

    PN 28 03044 Augus t 200 7 © 2007 Fluk e C orporati on, Al l ri ghts r eserve d. Pri nted i n USA All pro duct n ames are tr adem arks of their r espectiv e c ompani es. Ti 1 0 , Ti 2 5 , Ti R a n d Ti R 1 Thermal Imagers Users Manual ...

  • Fluke Thermal Imagers Ti10 - page 2

    LIMITED WARRANTY AND LIMI TATION OF LIABILITY Each Fl uke p roduc t is w arran ted to be f ree fr om def ects in ma teri al and workm anshi p und er no rmal use an d servic e. The wa rranty perio d is two yea rs and begins on th e dat e of sh ipme nt. Part s, pro duc t repairs, and s ervi ces ar e warr anted for 90 days . Thi s war ranty e xtends o ...

  • Fluke Thermal Imagers Ti10 - page 3

    i Table of Contents Title Page Introduction ............................................................................... 1 Contacting Fluk e ....................................................................... 1 Safety Inf ormation ..................................................................... 2 Unpacking th e Imager .................. ...

  • Fluke Thermal Imagers Ti10 - page 4

    Ti10, Ti25, TiR and TiR1 Users Man ual ii Changing the SD Card ............................................................... 15 Setting the Backlight .................................................................. 15 General Specifications ............................................................... 15 Detailed Specifications .............. ...

  • Fluke Thermal Imagers Ti10 - page 5

    iii List of Tables Table Title Page 1. Symbols ..................................................................................... 2 2. Features and C ontrols ................................................................ 4 List of Figures Figure Title Page 1. Range an d Span Settings ........................................................... ...

  • Fluke Thermal Imagers Ti10 - page 6

    Ti10, Ti25, TiR and TiR1 Users Man ual iv ...

  • Fluke Thermal Imagers Ti10 - page 7

    1 Introduction The Fluke Ti10, Ti25, TiR, and TiR1 Thermal Im agers (hereafter “the Imager”) are handheld im aging cam eras used for p redictive main tenance, equipm ent troublesho oting, an d verificatio n. All fou r Imagers prod uce therm al and visual imag es on a 640 X 480 disp lay. Thermal and visual im ages are displayed on the Im ager LC ...

  • Fluke Thermal Imagers Ti10 - page 8

    Ti10, Ti25, TiR and TiR1 Users Man ual 2 Safety Informatio n Use the Imager on ly as specified in this manual. See Table 1 for a lis t of sym bols us ed on t he Imag er and in th is manu al. A Wa rning identifies haz ardous co nditio ns an d acti ons tha t could c ause bodily harm or death. A Ca ution identi fies conditions and actions that could d ...

  • Fluke Thermal Imagers Ti10 - page 9

    Thermal Imagers Unpackin g the Im ager 3 Unpacking the Imager Carefully unpack the follo wing items: • Ti1 0, Ti 25, Ti R or Ti R 1 Im ag e r • AC Power Adapt er/Ch arger • Rug ge d Car r yi ng Case • SD Memory Card • SD Card Reader • Soft Transport Bag • User Manu als (in various langu ages) • SmartVie w™ Soft ware • Warranty R ...

  • Fluke Thermal Imagers Ti10 - page 10

    Ti10, Ti25, TiR and TiR1 Users Man ual 4 Table 2. Features and Controls 8 1 4 5 6 9 2 7 3 10 11 12 14 13 exj01.eps Item Description 1 LCD Disp lay 2 Function Softkey s (F1. F2, and F3) 3 Battery Cover 4 Speaker 5 Microph one 6 Auto backlig ht sen sor 7 Hand strap 8 AC adapter/c harger in put t erminal ...

  • Fluke Thermal Imagers Ti10 - page 11

    Thermal Imagers Using the Menu 5 Table 2. Fe atures and Contr ols (cont.) Item Description 9 SD mem ory card com partm ent 10 Retractabl e Lens Cover 11 Visual camera 12 Thermal (IR) camera 13 Focus contro l 14 Trigger Using the Menu The menus , coupled with the three s oftkeys ( c , a , and d ), provide access for setting features (date, tim e, la ...

  • Fluke Thermal Imagers Ti10 - page 12

    Ti10, Ti25, TiR and TiR1 Users Man ual 6 Setting the Date To set the date: 1. Pre ss a until Date appears over the F1 sof tkey. 2. Press the soft ke y labeled Date . The date can be dis play ed in one of two f ormats: MM/DD/Y Y or DD/MM/YY . 3. Press the softke y labeled w ith the desir e d date for mat. 4. Press the soft ke y labeled Up ( c ) or D ...

  • Fluke Thermal Imagers Ti10 - page 13

    Thermal Imagers Saving Im ager D ata 7 Note Minim um focus dis tance for thermal ( IR) camera is 15 cm ( approx. 6 inches) . Mini mum focus di stance f or vis ible ( vis ual) l ight camera i s 46 cm (appr ox. 18 i nches ). Note The Imager can s ave t he image as a si mple pict ure or as a radiomet ric i mage that all ows f urther temper ature analy ...

  • Fluke Thermal Imagers Ti10 - page 14

    Ti10, Ti25, TiR and TiR1 Users Man ual 8 Selecting a P alette The palette menu provides di fferent thermal vie wing patterns. Gra yscale, Blue- Red, High C ontrast, an d Ironbow are av ailable in all four Imagers . The TiR1 and Ti25 add Amber and Hot Metal to the list. T o select a palette: 1. Pre ss a until Palette appears over c . 2. Press the so ...

  • Fluke Thermal Imagers Ti10 - page 15

    Thermal Imagers Adjustin g the Therm al Im age 9 T otal Imager Range Span Le v el exj02.eps Figure 1. Range and Span S e ttings Setting the L evel (Manual) When put into manual ran ging, the level setti ng adjusts the ther mal span within the total temperature range o f the I mager. See Figure 1. To set th e level: 1. After en tering the manual ran ...

  • Fluke Thermal Imagers Ti10 - page 16

    Ti10, Ti25, TiR and TiR1 Users Man ual 10 2. Press the soft ke y labeled In crease to widen th e temperature span or Decreas e to narro w it. 3. Press the soft ke y labeled Done to set the I mager’s range level. Switching Between PI P and Full IR (Ti10 and TiR Onl y) The Imager can be set to display a fu ll in frared im age (Full IR) or an infrar ...

  • Fluke Thermal Imagers Ti10 - page 17

    Thermal Imagers Adding Voi ce Annot ation to S aved Data (T i25 and T iR1 Onl y) 11 4. Press the soft ke y labeled Up to display the previous image or Down to display the next s tored image. To delete a singl e Image fro m the SD card: 1. Perform t he st eps under viewing stored im ages above to brin g the des ired image to the displa y. 2. Press t ...

  • Fluke Thermal Imagers Ti10 - page 18

    Ti10, Ti25, TiR and TiR1 Users Man ual 12 Listeni ng to Voice Annot ations (Ti2 5 and TiR1 Only) To play the v oice annotation already st ored wi th an image on th e SD card: 1. Perform the st eps in the “Reviewing and Deleting Stored Imag es” s ection to bring th e desired imag e to the Imager’s dis play. 2. Press the soft ke y labeled Sele ...

  • Fluke Thermal Imagers Ti10 - page 19

    Thermal Imagers Setting Em issivity (Ti25 an d TiR1 only) 13 the object's surface. The Im ager detects the inf rared energy from an object and uses this information to esti mate the temperature of the obj ect. Mo st of the objects m easured s uch as painted m e tal, w ood, w ater, skin, and cl oth are v ery efficient at radiating en ergy and i ...

  • Fluke Thermal Imagers Ti10 - page 20

    Ti10, Ti25, TiR and TiR1 Users Man ual 14 To set the emissi vity value dir ectly: 1. Press the soft ke y labeled ε . 2. Press the soft ke y labeled Up or Down to increm e nt or decrement respectively the emissivity value displayed just above the softkey labels . 3. Press the soft ke y labeled Done to select the se t value. Setting File For mat Dat ...

  • Fluke Thermal Imagers Ti10 - page 21

    Thermal Imagers Changing t he SD Card 15 Changing the SD Card To eject an SD card from the Imag er, press in on the exposed edge of the SD card and th en releas e. The card sh ould pop parti ally out after releasin g it. Carefu lly pu ll the card ou t of the slot . Note The SD Car d can be i nsert ed and removed w hile the Imager is in operation. T ...

  • Fluke Thermal Imagers Ti10 - page 22

    Ti10, Ti25, TiR and TiR1 Users Man ual 16 Soft ware ................................................................SmartV iew™ full analysi s and reporting s oftware included Power Battery ...............................................................Rec hargeable ba ttery pack ( i ncluded) Battery Li fe ........................................ ...

  • Fluke Thermal Imagers Ti10 - page 23

    Thermal Imagers Detailed Speci ficati ons 17 Detailed Specifica tions Temperature Measurements Temperature Range (not calibrated below -10 ° C) TiR and Ti R1 ................................................. -20 ° C t o +100 ° C Ti10 ............................................................... -20 ° C to +250 ° C Ti25 ...................... ...

  • Fluke Thermal Imagers Ti10 - page 24

    Ti10, Ti25, TiR and TiR1 Users Man ual 18 Ti10 ............................................................ 5 ° C Ti25, TiR, and TiR1 ....................................2. 5 ° C Minim um span (in auto mode) Ti10 ............................................................ 10 ° C Ti25, TiR, and TiR1 ....................................5 ° C IR- ...

Manufacturer Fluke Category Digital Camera

Documents that we receive from a manufacturer of a Fluke Thermal Imagers Ti10 can be divided into several groups. They are, among others:
- Fluke technical drawings
- Thermal Imagers Ti10 manuals
- Fluke product data sheets
- information booklets
- or energy labels Fluke Thermal Imagers Ti10
All of them are important, but the most important information from the point of view of use of the device are in the user manual Fluke Thermal Imagers Ti10.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Fluke Thermal Imagers Ti10, service manual, brief instructions and user manuals Fluke Thermal Imagers Ti10. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Fluke Thermal Imagers Ti10.

Similar manuals

A complete manual for the device Fluke Thermal Imagers Ti10, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Fluke Thermal Imagers Ti10 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Fluke Thermal Imagers Ti10.

A complete Fluke manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Fluke Thermal Imagers Ti10 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Fluke Thermal Imagers Ti10, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Fluke Thermal Imagers Ti10, that we can find in the current document
3. Tips how to use the basic functions of the device Fluke Thermal Imagers Ti10 - which should help us in our first steps of using Fluke Thermal Imagers Ti10
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Fluke Thermal Imagers Ti10
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Fluke Thermal Imagers Ti10 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Fluke Thermal Imagers Ti10?

Use the form below

If you did not solve your problem by using a manual Fluke Thermal Imagers Ti10, ask a question using the form below. If a user had a similar problem with Fluke Thermal Imagers Ti10 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)