Manual Renesas H8/3864 Series

20 pages 0.26 mb
Download

Go to site of 20

Summary
  • Renesas H8/3864 Series - page 1

    H8/3864 Series QFP-80A User System Interface Cable (HS3864ECH61H) for E6000 Emulator User’s Manual HS3864ECH61HE(D) ...

  • Renesas H8/3864 Series - page 2

    Cautions 1. Renesas neither warrants nor grants li censes of any rights of Renesas’s or any t hird party’s patent, copyright, t rademark, or other intel lect ual property rights for informat ion contained in this document. Renesas bears no responsibility fo r problem s that may arise with third party’s rights, including int ellectual property ...

  • Renesas H8/3864 Series - page 3

    i Preface Thank you for purchasing this user system interface cable (HS3864ECH61H) for the Renesas’s original mi crocomputer H8/3864 series and H8/ 3887 series. The HS3864ECH61H is a user system interface cab le that connects an H8/3864 series, H8/3887 series E6000 em ulator (HS3880EPI60H; hereinafte r referred to as the emulator) t o the IC sock ...

  • Renesas H8/3864 Series - page 4

    ii Contents Section 1 Configuration .................................................................................... 1 Section 2 Connection Procedures ...................................................................... 4 2.1 Connecting User System Interf ace Cable to Em ulat or Station ......................................... 4 2.2 Connecti ...

  • Renesas H8/3864 Series - page 5

    Section 1 Configuration 1 UTION CA Use an IC149-080-017-B5 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-80A package IC socket on the user system. Figure 1 shows the configuration of the HS3864E CH61H user system interface cable for the FP-80A package. ...

  • Renesas H8/3864 Series - page 6

    User system IC socket Cable head Screws (M2 x 12 mm) with flat washers Screws (M2 x 8 mm) with flat washers Socket cover (for fastening cable head) To emulator station Cable body Figure 1 HS3864ECH61H User System Interface Cable 2 ...

  • Renesas H8/3864 Series - page 7

    3 Table 1 lists t he HS3864ECH61H components. Please m ake sure you have all of these com ponents when unpacking. Table 1 HS3864ECH61H Components No. Component Quantity Remarks 1 Cable body 1 Includes flat cable 2 Cable head 1 3 IC socket 1 For the FP-80A package 4 Socket cover 1 For installing an FP-80A-packaged MCU 5 Screws (M2 x 12 mm) 4 For fas ...

  • Renesas H8/3864 Series - page 8

    Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so w ill damage ...

  • Renesas H8/3864 Series - page 9

    2.2 Connecting User System Interface Cable to User System W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so w ill damage the user system and the emulator pro ...

  • Renesas H8/3864 Series - page 10

    2.2.4 Fastening Cable Head 6 UTION CA 1. Use a Phillips-type screwdriver whose head matches the screw head. 2. The tightening torque must be 0.0785 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a s ...

  • Renesas H8/3864 Series - page 11

    Fasten the user system interface cable head to the IC socket fo r an FP-80A package on the user system with the four screws (M2 x 12 m m ; with four flat washers) provided. Each screw should be tightened a little at a time, alternating between scre ws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to ...

  • Renesas H8/3864 Series - page 12

    2.2.5 Connecting Cable Body to Cabl e Head Connect the cable body to the cable head. Cable body Cable head Remove jig Push the remove jig Removing User system Figure 4 Fastening Cable Body 8 ...

  • Renesas H8/3864 Series - page 13

    2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows t he recomm ended dim ensions for the mount pad (footprint) for the user system with an IC socket for an FP-80A package (IC149-080-017-B5: m anufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewh at different from those of the actual chip&ap ...

  • Renesas H8/3864 Series - page 14

    2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interf ace cable head are shown in figure 6. Unit: mm Tolerance: –0.5 mm Figure 6 Dimensions for User System Interface Cable Head 10 ...

  • Renesas H8/3864 Series - page 15

    2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after conn ecting the user system interface cab le head to the user system, are shown in figure 7. Cable head User system Unit: mm Tolerance: –0.5 mm IC socket (IC149-080-017-B5 manufactured by YAMAICHI ELECTRONICS Co. Ltd.) Figure 7 Resulting Dimensio ...

  • Renesas H8/3864 Series - page 16

    Section 3 Installing the MCU to the User System 12 UTION CA 1. Check the location of pin 1 before inserting. 2. Use a Phillips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.0785 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becom ...

  • Renesas H8/3864 Series - page 17

    MCU Pin 1 IC socket (IC149-080-017-B5 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) User system Screws (M2 x 8 mm) with flat washers Socket cover Figure 8 Installing MCU to User System 13 ...

  • Renesas H8/3864 Series - page 18

    14 Section 4 Verifying Operation 1. When using the H8/3864 series, H8/3887 series E6000 em ulator (HS3880EPI60H), turn on the emulator according to the procedures descri bed in the H8/3864 seri es, H8/3887 series E6000 Emulator User' s Manual (HS3880EPI60HE). 2. Verify the user system interface cable c onnections by accessing ports and checkin ...

  • Renesas H8/3864 Series - page 19

    Figure 9 shows the system clock oscillator on the us er system interface cable and the subclock input specifications. 15 R2 270 R1 1 M HCU04 HCU04 To E6000 emulator OSC1 OSC2 System clock oscillator Ω Ω 0.8 Vcc 55 ns max. 55 ns max. 0.8 Vcc 0.3 Vcc 0 V Vcc Vcc: User System Vcc (1.8 to 5.5 V) 0.3 Vcc Subclock input specifications Figure 9 System ...

  • Renesas H8/3864 Series - page 20

    Section 5 Notice 1. Make sure that pin 1 on the user syst em IC socket is correct ly aligned with pin 1 on t he cable head before inserting the cable head into the user system IC socket. 2. The dimensions of t he recommended m ount pad for the user system IC socket are different from those of the MCU. 3. This user system interface cable is specifi ...

Manufacturer Renesas Category Computer Hardware

Documents that we receive from a manufacturer of a Renesas H8/3864 Series can be divided into several groups. They are, among others:
- Renesas technical drawings
- H8/3864 Series manuals
- Renesas product data sheets
- information booklets
- or energy labels Renesas H8/3864 Series
All of them are important, but the most important information from the point of view of use of the device are in the user manual Renesas H8/3864 Series.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Renesas H8/3864 Series, service manual, brief instructions and user manuals Renesas H8/3864 Series. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Renesas H8/3864 Series.

A complete manual for the device Renesas H8/3864 Series, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Renesas H8/3864 Series by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Renesas H8/3864 Series.

A complete Renesas manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Renesas H8/3864 Series - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Renesas H8/3864 Series, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Renesas H8/3864 Series, that we can find in the current document
3. Tips how to use the basic functions of the device Renesas H8/3864 Series - which should help us in our first steps of using Renesas H8/3864 Series
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Renesas H8/3864 Series
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Renesas H8/3864 Series in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Renesas H8/3864 Series?

Use the form below

If you did not solve your problem by using a manual Renesas H8/3864 Series, ask a question using the form below. If a user had a similar problem with Renesas H8/3864 Series it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)