Manual White Rodgers 1F95-71

8 pages 0.08 mb
Download

Go to site of 8

Summary
  • White Rodgers 1F95-71 - page 1

    All wiring must conform to local and national electrical codes and ordinances. This control is a precision instrument, and should be handled carefully. Rough handling or distorting compo- nents could cause the control to malfunction. To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit bre ...

  • White Rodgers 1F95-71 - page 2

    2 Approximately 5 feet from floor 1 ⁄ 2 ” hole for thermostat wire Stout cord with 6” chain attached Baseboard strip moulding 1 ⁄ 4 ” guide hole for sighting Quarter round removed 3 ⁄ 4 ” hole in floor of partition Hooked wire for snagging chain Figure 1. Routing thermostat wires SPECIFICA TIONS THIS CONTROL IS DESIGNED FOR USE WHERE ...

  • White Rodgers 1F95-71 - page 3

    3 TABLE 1. TERMINAL REFERENCE LABEL NUMBER 1F95 TERMINAL DESIGNATION FUNCTION OLD THERMOSTAT TERMINAL DESIGNATION (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) G C R O B Y1 Y2 W1 W2 W3 Fan Output Transformer 24 VAC Common Transformer 24 VAC Hot Changeover Output (Cooling) Changeover Output (Heating) Stage 1 Cool Stage 2 Cool Stage 1 Heat ...

  • White Rodgers 1F95-71 - page 4

    4 C R G B O CHANGEOVER ENERGIZED IN HEAT CHANGEOVER ENERGIZED IN COOL COMPRESSOR CONTACTOR STAGE 1 FAN RELAY HEAT RELAY STAGE 1 HEAT RELAY STAGE 2 HEAT RELAY STAGE 3 THERMOSTAT CONTROL CIRCUIT COMPRESSOR CONTACTOR STAGE 2 24 VAC 120 VAC HOT NEUTRAL THERMOSTAT SYSTEM Y1 Y2 W1 W2 W3 Figure 4. Typical wiring diagram for single transformer systems To p ...

  • White Rodgers 1F95-71 - page 5

    5 CAUTION ! NOTE NOTE C R O B CHANGEOVER ENERGIZED IN HEAT CHANGEOVER ENERGIZED IN COOL G FAN RELAY HEAT RELAY STAGE 1 HEAT RELAY STAGE 2 HEAT RELAY STAGE 3 THERMOSTAT CONTROL CIRCUIT 24 VAC 120 VAC HOT NEUTRAL THERMOSTAT SYSTEM COMPRESSOR CONTACTOR STAGE 1 Y1 COMPRESSOR CONTACTOR STAGE 2 Y2 W1 W2 W3 Figure 5. Typical wiring diagram for two-transfo ...

  • White Rodgers 1F95-71 - page 6

    6 SYSTEM CONFIGURA TION ANY TIME OPTION SWITCHES #1 OR #2 ARE CHANGED, THE 9 VOLT ENERGIZER ® BATTERY MUST BE REMOVED FOR A MINIMUM OF 2 MINUTES. Set Option Switches 1. For furnaces not requiring a G terminal to energize fan (systems with fan/limit switch or automatic fan on/ off operation): 2. For systems with electric furnace, and where blower i ...

  • White Rodgers 1F95-71 - page 7

    7 CAUTION ! Cooling System Operation To prevent compressor and/or property damage, if power to the compressor has been off or interrupted for more than 1 hour and the outdoor temperature is below 50 ° F, DO NOT operate the system for at least the amount of time the compres- sor was off! This will allow the compressor heaters to warm the compressor ...

  • White Rodgers 1F95-71 - page 8

    If you need further information about this product, please write to White-Rodgers Division, Emerson Electric Co. 9797 Reavis Road St. Louis, MO 63123-5398 Attention: Technical Service Department ...

Manufacturer White Rodgers Category Thermostat

Documents that we receive from a manufacturer of a White Rodgers 1F95-71 can be divided into several groups. They are, among others:
- White Rodgers technical drawings
- 1F95-71 manuals
- White Rodgers product data sheets
- information booklets
- or energy labels White Rodgers 1F95-71
All of them are important, but the most important information from the point of view of use of the device are in the user manual White Rodgers 1F95-71.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals White Rodgers 1F95-71, service manual, brief instructions and user manuals White Rodgers 1F95-71. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product White Rodgers 1F95-71.

A complete manual for the device White Rodgers 1F95-71, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use White Rodgers 1F95-71 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of White Rodgers 1F95-71.

A complete White Rodgers manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual White Rodgers 1F95-71 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the White Rodgers 1F95-71, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the White Rodgers 1F95-71, that we can find in the current document
3. Tips how to use the basic functions of the device White Rodgers 1F95-71 - which should help us in our first steps of using White Rodgers 1F95-71
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with White Rodgers 1F95-71
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of White Rodgers 1F95-71 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning White Rodgers 1F95-71?

Use the form below

If you did not solve your problem by using a manual White Rodgers 1F95-71, ask a question using the form below. If a user had a similar problem with White Rodgers 1F95-71 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)