Manual Vermont Castings A232

18 pages 0.3 mb
Download

Go to site of 18

Summary
  • Vermont Castings A232 - page 1

    INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER 10002734 6/00 Rev. 0 DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS: * Do not try to light any appliance. * Do not touch any electric switch * Do not use any phone in your build ...

  • Vermont Castings A232 - page 2

    - 2 - T ABLE OF CONTENTS PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Installation Instructions ............................. ...

  • Vermont Castings A232 - page 3

    - 3 - This gas fireplace should be installed by a qualified installer in accordance with local building codes and with current CAN / CGA-B149 (. 1 or .2) Installation codes for Gas Burning Fireplaces and Equipment. FOR U.S.A Installations follow local codes and/or the current National Fuel Gas Code. ANSI Z223.1. FOR SAFE INSTALLATION AND OPERATION ...

  • Vermont Castings A232 - page 4

    - 4 - A B C D E F G H J I K FIREPLACE DIMENSIONS MODEL A232 A 25" 635mm B 24 1/8" 613mm C 16" 406mm D 20" 508mm E 19" 483mm F 21" 533mm G 31 3/4" 806mm H 17 3/4" 451mm I 29 5/8" 752mm J 9" 229mm K5 1/4" 133mm L– – M– – N– – MODEL A232 ...

  • Vermont Castings A232 - page 5

    - 5 - GAS INLET & MANIFOLD PRESSURES Input Minimum Input Maximum Manifold Pressure NATURAL LP (Propane) 11" wc 13" wc 10" wc 4.5" wc 7" wc 3.5" wc 1/2" GAS SUPPLY 1/2" X 3/8" REDUCER 3/8" NIPPLE 3/8" NIPPLE 3/8" NIPPLE 3/8" X 3/8" SHUT OFF VALVE 3/8" UNION DO NOT USE THI ...

  • Vermont Castings A232 - page 6

    - 6 - INSTALLATION OF REMOTE SWITCH FOR RN/RP GAS VALVE Install on/off switch assembly on either the rear right or left side of the A232 Gas Fireplace. 1. Remove the screw at the back of the cabinet top either on the left or the right side of the fireplace. 2. Position switch assembly onto the back of the fireplace, then fasten two screws as shown ...

  • Vermont Castings A232 - page 7

    - 7 - Fig. 14 STRAIGHT B VENT CHIMNEY COMMON FLUE INSTALLATIONS In some areas it is possible to vent more than one gas fireplace into the same flue. You must ensure that the flue being shared has the proper capacity to handle both fireplaces. Check installation codes for venting capacity information. As always it is best to check with the authority ...

  • Vermont Castings A232 - page 8

    - 8 - Check Draft Here Fig. 16 Retrofitting To An Existing Brick Chimney It is strongly recommends installing an approved chimney liner in an existing brick chimney. This will maximize the potential draft of the chimney and lessen the effects of slow chimney start up. This is important because many homes (including older renovated ones) have become ...

  • Vermont Castings A232 - page 9

    - 9 - GENERAL GLASS INFORMATION Only glass approved for use in these products may be used for replacement. 1. The use of substitute glass will void all product warranties. 2. Care must be taken to avoid breakage of the glass. Under no circumstances should this fireplace be operated without the front glass or with a broken glass. Replacement of the ...

  • Vermont Castings A232 - page 10

    - 10 - KR2 KR5 KR6 KR4 KR3 KR1 Burner Lava Rock Placement GLASS CLEANING It will be necessary to clean the glass periodically. During start-up condensation, which is normal, forms on the inside of the glass and causes lint, dust and other airborne particles to cling to the glass surface. Also initial paint curing may deposit a slight film on the gl ...

  • Vermont Castings A232 - page 11

    - 11 - Fig. 20a FLAME ADJUSTMENT (RN/RP MODELS) For units equipped with Hi/Lo valves, flame adjustment is accomplished by rotating the Hi/Lo adjustment knob located near the centre of the gas control. (Fig. 20a & b) L O H I Turn counterclockwise to increase flame height. Turn clockwise to lower flame height. L O H I Turn counterclockwise to dec ...

  • Vermont Castings A232 - page 12

    - 12 - 4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. Close control access panel. 10. Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold the control knob in for about one (1) minute after the ...

  • Vermont Castings A232 - page 13

    - 13 - TROUBLE SHOOTING THE GAS CONTROL SYSTEM SIT NOV A 820 MILLIVOL T V AL VE Note: Before trouble shooting the gas control system, be sure external gas shut off is in the "On" position. WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE GLASS FRONT. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Spark ignitor will not light A. De ...

  • Vermont Castings A232 - page 14

    - 14 - • GAS SUPPLY ON • SUPPLY LINE HOOKED UP • SHUTOFF VALVE OPEN NO NO NO NO • LOCKOUT HAS ENGAGED. WAIT 60 SECONDS AND TRY AGAIN. • FOR SPARK AT ELECTRODE WHILE DEPRESSING PIEZO — 1/8" GAP TO PILOT HOOD NEEDED. • ALL WIRING CONNECTIONS • REPLACE PIEZO IGNITOR • FOR AIR IN THE LINES • THERMOPILE NEEDS A MINIMUM 325mV. AD ...

  • Vermont Castings A232 - page 15

    - 15 - REPLACEMENT P ARTS LIST D ESCRIPTION A232 1. Log Set Complete 10000160 1a. Log Ember Front KR1 1b. Log Front Left KR2 1c. Log Front Right KR3 1d. Log Rear KR4 1e. Log Top Left KR5 1f. Log Top Right KR6 2. Burner Lava Rock (Package) 57897 3a. Burner with Tiles Nat. 10000198 3b. Burner with Tiles Prop. 57904 4. Ceramic Tile (single) 57803 5a. ...

  • Vermont Castings A232 - page 16

    - 16 - 29 30 27 5/6a/b 19 18 13 11 17 15 28 7a/b 21a,b 44 41 42 43 31 32 36 a/b 37 39 46 45 39 43 41 42 it HI LO O F F P IL O T 25a/b 48 47 40 40 14 33 42 43 33 49 26 #1 - COMPLETE LOG SET -- A232 1b 1d 1e 1f 1a 1c 22 23 3a/b 4 2 40 8 a/b 12 17 16 L O H I PILOT ADJ PILOT ON OFF 24 a/b 20 10 a/b 9 a/b REPLACEMENT P AR TS ...

  • Vermont Castings A232 - page 17

    - 17 - OPTIONS MRC1 - On/Off Button Remote Control MRC2 - Temperature Control Remote MRC3 - Temperature Control w/digital display & 24 hour programmable clock IMT - Wall Mounted Thermostat REMOTE CONTROL For units with RN/RP valves ...

  • Vermont Castings A232 - page 18

    - 18 - 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7885 www .vermontcastings.com CFM Majestic, Inc. © Copyright CFM Majestic, Inc. 10002734 6/00 BASIC W ARRANTY : The CFM Majestic, Inc.™ (hereinafter referred to collectively as the "Company") warrants that your new V ermont Castings Gas Appliance is free from ...

Manufacturer Vermont Castings Category Indoor Fireplace

Documents that we receive from a manufacturer of a Vermont Castings A232 can be divided into several groups. They are, among others:
- Vermont Castings technical drawings
- A232 manuals
- Vermont Castings product data sheets
- information booklets
- or energy labels Vermont Castings A232
All of them are important, but the most important information from the point of view of use of the device are in the user manual Vermont Castings A232.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Vermont Castings A232, service manual, brief instructions and user manuals Vermont Castings A232. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Vermont Castings A232.

A complete manual for the device Vermont Castings A232, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Vermont Castings A232 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Vermont Castings A232.

A complete Vermont Castings manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Vermont Castings A232 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Vermont Castings A232, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Vermont Castings A232, that we can find in the current document
3. Tips how to use the basic functions of the device Vermont Castings A232 - which should help us in our first steps of using Vermont Castings A232
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Vermont Castings A232
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Vermont Castings A232 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Vermont Castings A232?

Use the form below

If you did not solve your problem by using a manual Vermont Castings A232, ask a question using the form below. If a user had a similar problem with Vermont Castings A232 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)